Search PubMedSearch

Biomedical subjects

V Legrand

Publications and source records attributed to V Legrand.

At least 19 recordsLinked to original sources

Clinical value of digital radiographic coronary quantification: comparison with visual assessment and coronary flow reserve.

The value of quantitative assessment of coronary artery dimensions at the site of the most critical coronary stenosis was assessed by comparison with the correspondent reactive hyperaemia as measured by digital subtraction angiography and with the functional results. Thirty-two coronary lesions were analysed and flow reserve data were obtained in an additional 11 vascular distributions without coronary obstruction in 19 patients. Minimal diameter less than 1.25 mm and minimal area less than 1.5 mm2 at the site of the stenosis best separated vascular distributions with inadequate hyperaemic response from those with sufficient reactive hyperaemia (chi 2 = 19.57; P less than 0.0001). Identification of lesion severity based on videodensitometric percentage area stenosis greater than 70% or percentage diameter stenosis greater than 50% yielded similar but poorer results (respectively chi 2 = 14.53; P less than 0.001 and chi 2 = 10.29; P less than 0.005). Additionally, when visually determined percentage stenosis was compared to the quantitatively assessed value, only a fair correlation was observed (r = 0.74), with visual overestimation of lesion severity by an average of 11.1 +/- 9.8% (mean +/- SD). Reactive hyperaemia in vessels with coronary obstruction could be described from minimal coronary dimensions by a quadratic equation but did not correlate closely in this patient population (r = 0.54 with minimal diameter and r = 0.58 with minimal area).(ABSTRACT TRUNCATED AT 250 WORDS)

Angiography, Digital Subtraction

Long-term follow-up of elderly patients with severe aortic stenosis treated by balloon aortic valvuloplasty. Importance of haemodynamic parameters before and after dilatation.

Early and late prognosis after percutaneous balloon aortic valvuloplasty (PBAV) was assessed in 38 consecutive elderly patients (mean age, 78.5 +/- 6.1 years). Significant valve opening was achieved in 35 patients. The hospital mortality was 8% (three patients); two other patients died within the first month and three underwent aortic valve replacement. At 2 years follow-up, there were 10 additional deaths (seven cardiac deaths) and five patients had symptom recurrence managed by aortic valve replacement (3) or repeat PBAV (2). Overall, six patients underwent surgery without untoward events and six had repeat PBAV. Only two out of six patients with repeat PBAV had sustained improvement; one was referred to surgery and the remaining three died soon after the second PBAV. One- and 2-year survival were respectively 72 and 62% and percentage of survivors with persistent improvement 68 and 41%. Although aortic valve area after PBAV was associated with outcome, predictors of poor long-term prognosis were primarily related to the pre-operative haemodynamic status. Patients with pulmonary resistances greater than 400 dynes cm-1 s-5 had the poorest outcome (chi 2 = 18.4-P less than 0.0001). Overall, signs of heart failure were predictors of poor long term follow-up. These data indicate that long-term success of PBAV is mainly related to the left ventricular dysfunction noted prior to intervention.

Aged

99mTc-MIBI (RP-30) to define the extent of myocardial ischemia and evaluate ventricular function.

99mTc-MIBI, a new myocardial perfusion agent, is a technetium labeled isonitrile derivative. We have taken advantage of the physical characteristics of 99mTc to combine at rest, post infarction, ventricular function studies with analysis of perfusion. We have studied at rest and at stress, 22 patients with coronary artery disease selected on the basis of an abnormal coronary angiogram or on the basis of a positive exercise ECG stress test for symptomatic angina. We have also studied, at rest only, 20 patients with a previous myocardial infarction. A comparative thallium planar scintigraphy was obtained for all patients. The sensitivity of 99mTc-MIBI scintigraphy for detecting individual vessel lesions at stress was 88% as compared with 83% for 201Tl. Sensitivity was higher in patients with previous myocardial infarction (93% for the 2 isotopes) than in patients without (85% for 99mTc-MIBI versus 81% for 201Tl). Segmental myocardial correspondence between 99mTc-MIBI and 201Tl was very close (92%). The overall sensitivity for the detection of acute myocardial infarction reached respectively 91% for 99mTc MIBI and 87% for 201Tl. The specificity in the regions corresponding to arteries not involved was excellent for both tracers as we did not observe any false positive result. This is important information but it does not correspond to the specificity to detect coronary artery disease in the overall patient population. The correlation between first pass left ventricular ejection fraction obtained with 99mTc-MIBI and equilibrium left ventricular ejection fraction obtained with 99mTc red cells was excellent (r = 0.96). It was not as good but was still satisfactory for the right ventricle (r = 0.75).(ABSTRACT TRUNCATED AT 250 WORDS)

Contrast Media

Short- and long-term prognostic importance of complete bundle-branch block complicating acute myocardial infarction.

Among 1013 consecutive patients with acute myocardial infarction (AMI), 104 (10%) developed complete bundle-branch block (BBB). The clinical characteristics and the short- and long-term prognosis were similar in the 53 patients with right and the 51 patients with left BBB. Compared to the 909 patients without this conduction disturbance, these 104 patients were older (64 +/- 9 vs. 58 +/- 10 years, p less than 0.001), more frequently women (26 vs. 17%, p less than 0.05), had a larger infarct (peak CK 1672 +/- 1124 vs. 1356 +/- 1089 IU/l, p less than 0.001), more frequently anterior (60 vs. 37%, p less than 0.001). They had a higher incidence of Killip class greater than 1 (63 vs. 38%, p less than 0.001), pericarditis (40 vs. 23%, p less than 0.001), atrial fibrillation or flutter (22 vs. 12%, p less than 0.01), ventricular fibrillation (15 vs. 9%, p less than 0.05), and atrioventricular block (23 vs. 11%, p less than 0.001). Both hospital mortality (32 vs 10%, p less than 0.001) and 3-year posthospital mortality (37 vs. 18%, p less than 0.001) were much higher among patients with complete BBB. Transient BBB had the same deleterious prognosis as BBB persistent at discharge (mortality 33 vs. 39%, NS). The prognostic importance of BBB was more prominent during the first 6 months after infarction (mortality between 6 and 36 months: 18% with BBB vs. 11% without BBB, NS).

Bundle-Branch Block

Left main coronary dissection after mild chest trauma. Favorable evolution with fibrinolytic and surgical therapies.

A 32-year-old woman had acute anterior myocardial infarction after a mild chest trauma (automobile accident). Unstable angina recurred shortly after admission, and extensive dissection of the left coronary artery was demonstrated. Medical therapy including systemic fibrinolysis was started but clinical stabilization and good long-term result was achieved only by aortocoronary bypass grafting.

Accidents, Traffic

Value of exercise radionuclide ventriculography and thallium-201 scintigraphy in evaluating successful coronary angioplasty: comparison with coronary flow reserve, translesional gradient and percent diameter stenosis.

Assessment of percutaneous transluminal coronary angioplasty (PTCA) by early radionuclide exercise test was evaluated for 11 arteries undergoing a successful procedure. Exercise thallium-201 (Tl-201) and radionuclide ventriculography (RNV) were performed within 3 days before and after PTCA and compared to % diameter stenosis, % translesional gradient and regional coronary flow reserve (CFR) determined by digital coronary angiography. Primary success of the procedure was gauged by reduction in % stenosis from 80 +/- 12% to 31 +/- 12% (residual stenosis less than 50% in all cases) and reduction in % gradient less than 25% in all cases). Before PTCA, Tl-201 and/or RNV were abnormal in all cases. After PTCA, radionuclide exercise tests improved but remained abnormal in 4 instances. No relationship was found between residual % gradient or stenosis and pathological Tl-201 or RNV following PTCA, but abnormal tests were observed among 4 out of the 5 vessels with the lowest CFR (less than 1.69). In one case CFR remained depressed despite good angiographic, hemodynamic and scintigraphic results, this patient had unstable angina before the procedure. Among patients with stable symptoms, CFR of arterial distributions with positive Tl-201 or RNV after PTCA was significantly lower than that with negative tests (1.58 +/- 0.05 as compared to 1.90 +/- 0.25, P less than 0.02). Early radionuclide stress tests results thus reflect the physiologic improvement of coronary circulation. They may reflect the persistence of coronary flow abnormalities despite the relief of the epicardial stenosis.

Angioplasty, Balloon

Comparative study of coronary flow reserve, coronary anatomy and results of radionuclide exercise tests in patients with coronary artery disease.

A comparative assessment of regional coronary flow reserve, quantitative percent diameter coronary stenosis and exercise-induced perfusion and wall motion abnormalities was performed in 39 patients with coronary artery disease. Coronary flow reserve was determined by a digital angiographic technique utilizing contrast medium as the hyperemic agent. Percent diameter stenosis was calculated by an automated quantification program applied to orthogonal cineangiograms. Thallium-201 scintigraphy and radionuclide ventriculography were used to assess regional perfusion and wall motion abnormalities, respectively, at rest and during exercise. In Group A, 19 patients without transmural infarction or collateral vessels, coronary flow reserve was inversely related to percent diameter stenosis (r = -0.61, p less than 0.0001), and scintigraphic abnormalities occurred only in vascular distributions with a coronary flow reserve of less than 2.00. There was a strong relation among abnormal regional exercise results, stenoses greater than 50% and reactive hyperemia of less than 2.00. Patients with multivessel disease, however, often had normal exercise scintigrams in regions associated with greater than 50% stenosis and low coronary flow reserve when other regions had a lower coronary flow reserve or higher grade stenosis, or both. In Group B, 20 patients with angiographically visible collateral vessels, 12 of whom had prior myocardial infarction, coronary flow reserve correlated less well with percent diameter stenosis than in Group A (r = -0.47, p less than 0.004). As in Group A patients, there was a significant relation between abnormal exercise test results and stenoses greater than 50%. However, reactive hyperemia values were generally lower than in Group A, and positive exercise stress results were strongly correlated only with highly impaired flow reserves of 1.3 or less. In Group B patients, the coronary flow reserve of vessels with less than 50% stenosis was significantly lower than that of similar vessels in Group A patients (2.40 +/- 0.79 versus 1.56 +/- 0.43; p less than 0.0002). It is concluded that: there is a general relation between quantitative percent diameter stenosis and reactive hyperemia that is not of sufficient precision to allow accurate prediction of coronary flow reserve in individual cases; exercise scintigraphic abnormalities are usually associated with low coronary flow reserve, and the relation between these two functional tests is stronger than the relation between exercise test results and quantitative percent diameter stenosis.(ABSTRACT TRUNCATED AT 400 WORDS)

Aged

Complementary role of thallium-201 scintigraphy to predischarge exercise electrocardiography for patients stratification after a first myocardial infarction.

The value of a predischarge exercise test combined with thallium-201 myocardial scintigraphy in detecting patients with severe multivessel disease (MVD) was studied in 58 consecutive patients discharged after a first acute myocardial infarction. Twelve electrocardiographic, clinical and scintigraphic variables were analysed. Angiography at one month revealed MVD (greater than 70% narrowing in vessels unrelated to infarction) in 26 patients (45%). ST segment depression of 1mm or greater, thallium defects in multiple vascular distributions (MVTL), and reversible thallium defects in a vascular distribution different from the infarct related vessel predicted patients at risk for MVD (predictive value respectively of 68%, 65% and 75%). The other variables were not significantly associated with the presence of MVD. Only ST segment depression and thallium defects in multiple vascular distributions emerged as independent predictors of MVD. Their combination yielded a 77% sensitivity and a 59% specificity for MVD. Combination of thallium imaging with the predischarge exercise ECG significantly improved the stratification provided by the exercise test alone (P less than 0.05). A positive thallium scan (MVTl defects) associated with a positive ECG (ST depression) carried a risk for MVD of 80% in the population studied. When both tests were negative, MVD was infrequent (risk 22%). Because improvement in the stratification of patients is not as clear as expected from studies performed at a later stage, it appears that exercise thallium scintigraphy at a submaximal level one or two weeks after infarction does not provide optimal information. Predischarge exercise thallium-201 scintigraphy, however, is superior to an exercise tolerance test alone in separating patients into those with high and low risk of MVD.

Electrocardiography

Left ventricular potentiation at a reduced exercise level: a cause of false-negative radionuclide ventriculograms.

During exercise radionuclide ventriculography (RVG), many patients cannot maintain peak workload for acquisition of more than a left anterior oblique view. To acquire further views, the workload may have to be reduced. In this study of 16 normals and 20 patients with coronary disease, the workload at peak exercise was reduced by approximately 40%. By paired t-test analysis, there was a rise in the left ventricular ejection fraction (LVEF) in patients with coronary disease from the peak exercise workload to the reduced workload level (postpeak) (52.4 +/- 15.3 to 59.3 +/- 13.7, P = .0001). There was also improvement in LVEF in the normals at the postpeak workload (71.3 +/- 11.7 to 75.1 +/- 13.7, P = .05). Of five coronary disease patients with exercise-induced wall motion abnormalities, four returned to baseline motion at the reduced exercise levels. Partial workload reduction can lead to an increase in LVEF and improvement in wall motion and thus, may result in false-negative studies.

Adult

Abnormal coronary flow reserve and abnormal radionuclide exercise test results in patients with normal coronary angiograms.

Coronary flow reserve, exercise thallium-201 scintigraphy and exercise radionuclide ventriculography were compared in 18 patients with chest pain and angiographically normal coronary arteries. Regional exercise thallium-201 perfusion was abnormal in three patients, regional exercise wall motion was abnormal in three other patients and results of both tests were abnormal in one additional patient. Left ventricular ejection fraction responses were abnormal in five of these seven patients. The coronary flow reserve of arterial distributions with abnormal perfusion or regional dysfunction was significantly lower than that of distributions associated with normal radionuclide results (1.42 +/- 0.23 versus 2.58 +/- 0.83, p less than 0.001). All patients with abnormal scintigraphic results had low coronary flow reserve (less than 1.95) in at least one distribution. Perfusion abnormalities appeared to be more localized in the arterial distributions with the lowest flow reserve. Only two patients had low flow reserve (less than 1.95) with normal scintigraphic results; both were hypertensive. These data suggest that abnormal exercise scintigraphic findings in patients with angiographically normal coronary arteries and chest pain are indicative of true blood flow or perfusion abnormalities.

Adult

Comparative haemodynamic effects of intravenous flecainide in patients with and without heart failure and with and without beta-blocker therapy.

The haemodynamic effects of flecainide were compared in three different subsets of patients with documented coronary disease. Ten patients (A) had no heart failure, 5 patients were on beta blockers (B) and 5 patients had overt heart failure (C). Flecainide was associated with negative inotropic effects that were relatively more pronounced in patients with left ventricular dysfunction: pulmonary wedge pressure increased by 27% in A, by 31% in B and by 42% in C; left ventricular stroke volume and stroke work decreased respectively by 10 and 12% in A, 21 and 19% in B, 26 and 28% in C. Ejection fraction decreased by 9% in A, 13% in B and 20% in C, in relation with an increase in end systolic volume (+9% in A, +10% in B and +5% in C). Absolute changes, however, were not significantly different from one group to another except for the increase of systemic vascular resistance which was more pronounced in C as compared with the other groups. The myocardial depression was also confirmed by the fall in dP/dt that was maximal at the end of injection; dP/dt remained depressed 15 min later despite some improvement. Flecainide thus exerts negative inotropic effects that are maximal at the end of infusion and may be of importance in patients with established left ventricular dysfunction.

Adult

Comparative long-term effects of coronary artery bypass graft surgery and percutaneous transluminal coronary angioplasty on regional coronary flow reserve.

To evaluate the relative long-term improvement in coronary artery hemodynamics after revascularization by coronary artery bypass graft surgery (CABG) or percutaneous transluminal coronary angioplasty (PTCA), regional coronary flow reserve (CFR) was measured, by digital computer analysis of 35 mm cine film, in 50 men undergoing cardiac catheterization. CFR (mean +/- SEM) in 12 atherosclerotic arteries before revascularization was 1.02 +/- 0.05. Mean CFR in 29 normal arteries of men with normal coronary arteriograms was significantly higher (2.59 +/- 0.11) than that in 16 atherosclerotic arteries of patients revascularized by CABG (2.02 +/- 0.17, p less than .01) or in 14 atherosclerotic arteries of those revascularized by PTCA (1.97 +/- 0.12, p less than .01). No difference in CFR between the CABG and PTCA groups was found and variables known to influence CFR were similar between groups. Equivalent and significant long-term improvement in coronary artery hemodynamics is provided by CABG or PTCA. We postulate that the difference in CFR in the men with normal arteries and those who underwent revascularization was related to the effects of the general atherosclerotic process, which remain despite successful treatment by these techniques.

Angiography

Quantitative assessment of global and regional left ventricular function with low-contrast dose digital subtraction ventriculography.

Few studies have compared the use of low-contrast dose digital subtraction ventriculography with conventional ventriculography for quantitative assessment of both global and regional left ventricular function. Accordingly, 34 patients underwent conventional ventriculography using 36 ml of ionic contrast material and digital ventriculography (mask-mode) using 10 ml of contrast diluted in 10 ml of saline and injected over two seconds. Data from two patients were excluded because of ectopy during cineventriculography and from one because of ectopy during both studies. End-diastolic and end-systolic volumes were calculated from both studies by an area-length method and used to calculate ejection fractions. Regional wall motion was quantitated by the centerline method. Results of linear regression analysis demonstrated high correlations for all parameters (end-diastolic volume, r = 0.85; end-systolic volume, r = 0.93; ejection fraction, r = 0.92; quantitative regional wall motion, r = 0.90). Thus, low-contrast dose digital subtraction ventriculography provides an accurate assessment of both global and regional ventricular function and minimizes the required dose and inherent risks of contrast media.

Adult