Search PubMed⌕ Search

Biomedical subjects

V K Goel

Publications and source records attributed to V K Goel.

At least 19 recordsLinked to original sources

The pathomechanism of spondylolytic spondylolisthesis in immature primate lumbar spines in vitro and finite element assessments.

STUDY DESIGN: Immature Chacma baboon (Papio ursinus) spine specimens were used to determine load-displacement behavior as related to disc injury. This was accomplished through the application of A-P shear force until failure of FSUs with pars defects. Several finite element models (FEMs) of the FSU were developed to study the mechanism of slippage in immature baboon lumbar spines. OBJECTIVES: The purpose was to show that spondylolisthesis (olisthesis) always occurs through the growth plate using a model similar to immature human lumbar spines. Using FEMs, the roles of facet orientation, pars interarticularis thickness, and a weak growth-plate in producing slippage were examined. SUMMARY OF BACKGROUND DATA: Progression from spondylolysis (lysis) to olisthesis occurs, most often, during the adolescent growth spurt. The biomechanical literature dealing with the slippage mechanism in the immature lumbar spine does not provide a clear understanding and is sparse. METHODS: Several groups of FSUs were subjected to A-P shear force until failure. The results provided displacement at failure as a function of disc injury and flexion-extension fatigue. A bilateral pars defect was created in each specimen prior to application of A-P shear force using an MTS machine. Failure sites were assessed radiographically and histologically. A nonlinear 3-D FEM of the intact L4-L5 was created from CT scans. The model was modified to predict the effects of a pars fracture, a thin pars, a weak growth plate, and facet orientation on the shear load through the growth plate and stresses in the pars. RESULTS: Experimentally, failures always occurred through the growth-plate in the disc intact and disc-incised groups. In the intact FEM, the growth plate carried21% of the applied A-P shear force. The load increased when the facets were more sagittally oriented. The effect of thin pars and/or weaker growth plate was an increase in stresses in the pars. Changes in the load through the growth plate were minimal. CONCLUSIONS: The weakest link in immature baboon lumbar functional spinal units (FSUs) with lysis during an A-P shear load was the growth plate, between the cartilaginous and osseous end plates. Surgeons may assess this lesion on MRI views, thereby predicting the possible development and preventing progression of olisthesis. Finite element model results predict that more sagittally orientated facets and/or a pars fracture are prerequisites for olisthesis to occur.

Age Factors↗

Pathomechanisms of failures of the odontoid.

STUDY DESIGN: A finite element investigation to determine the causal mechanisms that lead to odontoid fracture. OBJECTIVES: To elucidate which loading scenarios, including rotational moments, compression-tension, and lateral and anteroposterior shear, can result in Type I, Type II, and Type III odontoid failures. SUMMARY OF BACKGROUND DATA: There is considerable controversy about the major loading path that causes odontoid fractures. A review of the clinical and laboratory research literature did not provide a consensus on this issue. METHODS: A three-dimensional, nonlinear finite element model of the occipito-atlantoaxial (C0-C1-C2) complex was generated from human cadaveric data. Force loads were applied at the posterior margin of the occiput and were applied as lone entities or after the model was prepositioned in flexion, extension, or lateral-bending moments through applied rotation moments. Intraosseous stresses were reported to characterize the probability of fracture due to the applied loadings. RESULTS: The data indicate that hyperextension can lead to failure of the odontoid at its superior tip (Type I). Finite element model predictions also demonstrated the propensity of loads that induce axial rotation to create relatively high maximum von Mises stress in the Type II fracture region. Flexion prepositioning reduced the stress response of the odontoid. CONCLUSIONS: Force loading that puts the head in extension coupled with lateral shear or compression leads to Type I fractures, whereas axial rotation and lateral shear can produce Type II fractures. The model failed to elucidate causal mechanisms for Type III fractures. Flexion seems to provide a protective mechanism against force application that would otherwise cause a higher risk of odontoid failure.

Atlanto-Occipital Joint↗

Impact response of the intervertebral disc in a finite-element model.

STUDY DESIGN: A three-dimensional nonlinear poroelastic finite-element model of a vertebra disc was used to analyze the biomechanical effects of impact loading on the spinal segment. OBJECTIVES: To predict changes in biomechanical parameters such as intradiscal pressure, dynamic stiffness, stresses in the endplate region, and the shock-absorbing mechanism of the spine under different impact duration/loading rates, and to investigate the relation between the rate of loading and the fracture potential of the vertebral body. SUMMARY OF BACKGROUND DATA: It is not practical to discern the role of impact duration using experimental protocols. Analytical studies are better suited to this purpose. However, previous poroelastic finite-element models of the motion segments have dealt mostly with creep phenomena. METHODS: A three-dimensional, L3-L4 motion-segment, finite-element model was modified to incorporate the poroelastic properties of the disc, endplate, and cancellous core, and thus simulate the shock-absorbing phenomena. The results were analyzed under variable impact durations for a constant maximum compressive impact load of 3 kN. RESULTS: For a shorter impact duration and a given F(max), relatively high cancellous core pressure was generated as compared with a case of long impact duration, although the amount of impulse was increased. In contrast, relatively constant pore pressures were generated in the nucleus regardless of the impact duration. The changes in spinal segment stiffness as a function of impact duration indicated that for a shorter duration of impact, high dynamic stiffness increases the stability of the spinal segment against the impact load. However, the corresponding increase in stresses within the vertebral body and endplate may produce fractures. CONCLUSIONS: The finite-element technique was used to address the role of impact duration in producing trauma to the spinal motion segment. Within the limitations of the model, the results suggest that fractures are likely to occur under shorter impact duration conditions. Depending on the strength of the region, a fracture may be initiated in the endplate region or the posterior wall of the cortical shell. The nucleus pressure is independent of the impact duration and depends only on the magnitude of the impact force.

Computer Simulation↗

Biomechanical rationale for the pathology of rheumatoid arthritis in the craniovertebral junction.

STUDY DESIGN: A finite-element model of the craniovertebral junction was developed and used to determine whether a biomechanical mechanism, in addition to inflammatory synovitis, is involved in the progression of rheumatoid arthritis in this region of the spine. OBJECTIVES: To determine specific structure involvement during the progression of rheumatoid arthritis and to evaluate these structures in terms of their effect on clinically observed erosive changes associated with the disease by assessing changes in loading patterns and degree of anterior atlantoaxial subluxation. SUMMARY OF BACKGROUND DATA: Rheumatoid arthritis involvement of the occipito-atlantoaxial (C0-C1-C2) complex is commonly seen. However, the biomechanical contribution to the development and progression of the disease is neither well understood nor quantified. Although previous cadaver studies have elucidated information on kinematic motion and fusion techniques, the modeling of progressive disease states is not easily accomplished using these methods. The finite-element method is well suited for studying progressive disease states caused by the gradual changes in material properties that can be modeled. METHODS: A ligamentous, nonlinear, sliding-contact, three-dimensional finite-element model of the C0-C1-C2 complex was generated from 0.5 mm thick serial computed tomography scans. Validation of the model was accomplished by comparing baseline kinematic predictions with experimental data. Transverse, alar, and capsular ligament stiffness were reduced sequentially by 50%, 75%, and 100% (removal) of their intact values. All models were subjected to flexion moments replicating the clinical diagnosis of rheumatoid arthritis using full flexion lateral plane radiographs. Stress profiles at the transverse ligament-odontoid process junction were monitored. Changes in loading profiles through the C0-C1 and C1-C2 lateral articulations and their associated capsular ligaments were calculated. Anterior and posterior atlantodental interval values were calculated to correlate ligamentous destruction with advancement of atlantoaxial subluxation. RESULTS: Model predictions (at 0.3 Nm) fell within one standard deviation of experimental means, and range of motion data agreed with published in vitro and in vivo values. The model predicted that stresses at the posterior base of the odontoid process were greatly reduced with transverse ligament compromise beyond 75%. Decreases through the lateral C0-C1 and C1-C2 articulations were compensated by their capsular ligaments. Anterior and posterior atlantodental interval values indicate that the transverse ligament stiffness decreases beyond 75% had the greatest effect on atlantoaxial subluxation during the early stages of the disease (no alar and capsular ligament damage). Subsequent involvement of the alar and capsular ligaments produced advanced atlantoaxial subluxation, for which surgical intervention may be warranted. CONCLUSIONS: To the best of the authors' knowledge, this is the first report of a validated, three-dimensional model of the C0-C1-C2 complex with application to rheumatoid arthritis. The data indicate that there may be a mechanical component (in addition to enzymatic degradation) associated with the osseous resorption observed during rheumatoid arthritis. Specifically, erosion of the odontoid base may involve Wolff's law of unloading considerations. Changes through the lateral aspects of the atlas suggest that this same mechanism may be partially responsible for the erosive changes seen during progressive rheumatoid arthritis. Anterior and posterior atlantodental interval values indicate that complete destruction of the transverse ligament coupled with alar and/or capsular ligament compromise is requisite if advanced levels of atlantoaxial subluxation are present.

Arthritis, Rheumatoid↗

Biomechanical studies of a dynamized anterior thoracolumbar implant.

STUDY DESIGN: An in vitro investigation into the biomechanical properties of a dynamized anterolateral compression implant that allows controlled subsidence. OBJECTIVES: To determine the extent to which both modes of the anterolateral compression implant (controlled collapsing and rigid) are able to reestablish the stability of the lumbar spine after L4 corpectomy. SUMMARY OF BACKGROUND DATA: Over time, anterior and posterior spinal implants have been associated with progressive angulation, and occasionally implant failure and breakage. To circumvent this occurrence and provide better graft loading, dynamized or collapsing devices for clinical use have been developed. METHODS: Eight fresh calf spines (L1-L6) were placed in a biomechanical testing frame. Pure moments of 6 Nm were loaded onto the intact spine in six directions: flexion, extension, right and left lateral bending, and right and left axial rotation. A total L4 corpectomy then was performed, and the defect grafted with a wooden dowel. Loading was repeated after the specimens were stabilized using the two modes of the anterolateral compression implant in succession. RESULTS: The results showed that both modes of the implant (the rigid mode in particular) restore the stiffness of the unstable spine to normal levels of flexion, extension, and right and left lateral bending, even to levels exceeding normal. These devices, however, fall short of achieving normal stability in right and left axial rotation. CONCLUSION: In the cadaveric calf spine after L4 corpectomy, restoration of stability with a dynamized anterior spinal implant is possible in flexion, extension, and right and left lateral bending, but not in axial rotation.

Animals↗

Evaluation of low back muscle surface EMG signals using wavelets.

OBJECTIVE: To compare the ability of observers to correctly detect the reaction time of erector spinae response to unexpected load by inspecting nonprocessed electromyographic signals versus inspection of wavelet transformed electromyographic signals and versus automatic detection on the same wavelet transformed signals. BACKGROUND: Traditionally, electromyographic signal analysis is performed using Fourier transform based methods. However, muscle response to transients such as unexpected load, have limitations when using these methods of electromyographic processing. DESIGN: A comparison was made of the three methods using the same signals attained during sudden loading of the trunk. METHODS: 11 chronic low back pain patients and eleven normal subjects were investigated in sudden loading. Surface electromyographic signals were obtained from the erector spine muscle at L3. The ability of observers to detect reaction time of erector spinae muscle responses of nonprocessed electromyographic signals versus inspection of wavelet transformed electromyographic signals versus an automatic peak detection program was determined. RESULTS: The results have shown that the spine muscle reaction time was easier and more accurately determined in the wavelet domain rather than in its original signal representation. CONCLUSION: Wavelet transform methods improved the analysis of electromyographic signals in the time domain by facilitating the determination of the time of muscle activity. RELEVANCE: Wavelet transform could be a valuable tool for electromyographic analysis in resolving the psychophysical problem of perception involved in the analysis of nonprocessed signals. In clinical environments, where the speed and the accuracy of the analysis of electromyographic signal is critical, the wavelet based signal processing could be very important.

Adult↗

In vitro biomechanical analysis of three anterior thoracolumbar implants.

OBJECT: The goal of this study was to evaluate the comparative efficacy of three commonly used anterior thoracolumbar implants: the anterior thoracolumbar locking plate (ATLP), the smooth-rod Kaneda (SRK), and the Z-plate. METHODS: In vitro testing was performed using the T9-L3 segments of human cadaver spines. An L-1 corpectomy was performed, and stabilization was achieved using one of three anterior devices: the ATLP in nine spines, the SRK in 10, and the Z-plate in 10. Specimens were load tested with 1.5-, 3-, 4.5-, and 6-Nm in flexion and extension, right and left lateral bending, and right and left axial rotation. Angular motion was monitored using two video cameras that tracked light-emitting diodes attached to the vertebral bodies. Testing was performed in the intact state in spines stabilized with one of the three aforementioned devices after the devices had been fatigued to 5000 cycles at +/- 3 Nm and after bilateral facetectomy. There was no difference in the stability of the intact spines with use of the three devices. There were no differences between the SRK- and Z-plate-instrumented spines in any state. In extension testing, the mean angular rotation (+/- standard deviation) of spines instrumented with the SRK (4.7 +/- 3.2 degrees) and Z-plate devices (3.3 +/- 2.3 degrees) was more rigid than that observed in the ATLP-stabilized spines (9 +/- 4.8 degrees). In flexion testing after induction of fatigue, however, only the SRK (4.2 +/- 3.2 degrees) was stiffer than the ATLP (8.9 +/- 4.9 degrees). Also, in extension postfatigue, only the SRK (2.4 +/- 3.4 degrees) provided more rigid fixation than the ATLP (6.4 +/- 2.9 degrees). All three devices were equally unstable after bilateral facetectomy. The SRK and Z-plate anterior thoracolumbar implants were both more rigid than the ATLP, and of the former two the SRK was stiffer. CONCLUSIONS: The authors' results suggest that in cases in which profile and ease of application are not of paramount importance, the SRK has an advantage over the other two tested implants in achieving rigid fixation immediately postoperatively.

Aged↗

Stability analysis of an enhanced load sharing posterior fixation device and its equivalent conventional device in a calf spine model.

STUDY DESIGN: An in vitro test of calf spine lumbar segments to compare biomechanical stabilization of a rigid versus a dynamic posterior fixation device. OBJECTIVES: To compare flexibility of a dynamic pedicle screw fixation device with an equivalent rigid device. SUMMARY OF BACKGROUND DATA: Dynamic pedicle screw device studies are not as prevalent in the literature as studies of rigid devices. These devices contain the potential to enhance load sharing and optimize fusion potential while maintaining stability similar to that of rigid systems. METHODS: Load-displacement tests were performed on intact and stabilized calf spines for the dynamic and rigid devices. Stability across a destabilized L3-L4 segment was restored by insertion of either a 6 mm x 40 mm dynamic or rigid pedicle screw fixation device across the L2-L4 segment. The screws then were removed, 7 mm x 45 mm pedicle screws of the opposite type were inserted, and the construct then was re-tested. Axial pull-out tests were performed to assess the likely effects of pedicle screw replacement on the load-displacement data. RESULTS: Results indicated a 65% reduction in motion in flexion-extension and a 90% reduction in lateral bending across the destabilized level for both devices, compared with intact spine values. Reduction in axial rotation motion was much smaller than in other modes. Axial pull-out tests showed no weakening of the bone-screw interface. CONCLUSIONS: Both devices provided significant stability of similar magnitudes in flexion, extension, and lateral bending. In axial rotation, the devices only could restore stability to levels similar to those in an intact spine. The dynamic device offers a design that may enhance load sharing without sacrificing construct stability.

Animals↗

Biomechanical studies on two anterior thoracolumbar implants in cadaveric spines.

STUDY DESIGN: A biomechanical comparison of two commonly used anterior spinal devices: the Smooth Rod Kaneda and the Synthes Anterior Thoracolumbar Spinal Plate. OBJECTIVES: To compare the stability imparted to the human cadaveric spine by the Smooth Rod Kaneda and Synthes Anterior Spinal Plate, and to assess how well these devices withstand fatigue and uni- and bilateral facetectomy. SUMMARY OF BACKGROUND DATA: Biomechanical studies on the aforementioned and similar devices have been performed using synthetic, porcine, calf, or dog spines. As of the time of this writing, studies comparing anterior spinal implants using human cadaveric spines are scarce. METHODS: An L1 corpectomy was performed on 19 spines. Stabilization was accomplished by an interbody wooden graft and the application of the Smooth Rod Kaneda in 10 spines and the Synthes Anterior Spinal Plate in the remaining 9. Biomechanical testing of the spines was performed in six degrees of freedom before and after stabilization, and after fatiguing to 5000 cycles of +/- 3 Nm of flexion and extension. Testing was repeated after uni- and bilateral facetectomy. RESULTS: After stabilization, the Smooth Rod Kaneda was significantly more rigid than the anterior thoracolumbar bar spinal plate in extension. After fatigue, the Smooth Rod Kaneda was significantly stiffer than the anterior thoracolumbar spinal plate in flexion, extension, right lateral bending, left lateral bending, and right axial rotation. A significant decrease in stiffness was noted with the Synthes device in flexion after bilateral facetectomy compared with the stabilized spine. CONCLUSIONS: The smooth Rod Kaneda device tends to be stiffer than the anterior thoracolumbar spinal plate, particularly in extension, exceeding the anterior thoracolumbar spinal plate in fatigue tolerance. The spine stabilized with the anterior thoracolumbar spinal plate is more susceptible to the destabilizing effect of bilateral facetectomy than than that stabilized with the Smooth Rod Kaneda. The additional rigidity encountered with the Smooth Rod Kaneda must be weighed against the simplicity of anterior thoracolumbar spinal plate application.

Aged↗

Cervical electromyographic activity during low-speed rear impact.

Whiplash motion of the neck is characterized by having an extension-flexion motion of the neck. It has been previously assumed that muscles do not play a role in the injury. Eight healthy males were seated in a car seat mounted on a sled. The sled was accelerated by a spring mechanism. Muscle electromyographic (EMG) activity was measured by wire electrodes in semi-spinalis capitis, splenius capitis, and levator scapulae. Surface EMG activity was measured over trapezius and sternocleidomastoideus. Wavelet analysis was used to establish the onset of muscle activity with respect to sled movement. Shorter reaction times were found to be as low as 13.2 ms from head acceleration and 65.6 ms from sled acceleration. Thus the muscles could influence the injury pattern. It is of interest that clinical symptoms are often attributed to muscle tendon injuries.

Acceleration↗

Is there a rational basis for post-surgical lifting restrictions? 2. Possible scientific approach.

Lifting restrictions postoperatively are quite common but there appears to be little scientific basis for them. Lifting restricitions are inhibitory in terms of return to work and may be a factor in chronicity. The mean changes in functional spinal motion unit (FSU) stiffness with in vitro or computer-simulated discectomies, facetectomies and laminectomies were reviewed from the literature. We modified the NIOSH lifting equation to include another multiplier related to stiffness change post surgery. The new recommended lifts were computed for different lifting conditions seen in industry. The reduction of rotational stiffness ranged from 21% to 41% for a discectomy, 1% to 59% for a facetectomy and 4% to 16% for a partial laminectomy. The recommended lifts based on our modified equation were adjusted accordingly. There is no rational basis for current lifting resctrictions. The risk to the spine is a function of many other variables as well as weight (i.e., distance of weight from body). The adjusted NIOSH guidelines provide a reasonable way to estimate weight restrictions and accomodations such as lifting aids. Such resitrictions should be as liberal as possible so as to facilitate, not prevent, return to work. Patients need more advice regarding lifting activities and clinicians should be more knowledgeable about the working conditions and constraints of a given workplace to effectively match the solution to the patient's condition.

Diskectomy↗

Active responses decrease impact forces at the hip and shoulder in falls to the side.

Active responses, such as using the arm to break the fall, may be an effective means of decreasing likelihood of injury in a fall and may help explain why only a small percentage of falls result in a fracture. We quantified the impact force at the hip and shoulder in falls to the side from a kneeling position under three conditions: (1) attempting to break the fall by using an arm; (2) falling with the body relaxed; and (3) falling with the body tensed. Subjects fell from a kneeling position onto a force platform array covered with foam padding and impact force data were recorded. The ground reaction force-time curve was generally bimodal due to sequential impacts of the hip and shoulder. Impact forces at the hip and shoulder were 12 and 16% less for the slap condition (p < 0.05) than for the tensed condition. The impact forces for the relaxed and tensed conditions were not significantly different, although impact forces tended to be less in the relaxed condition. We concluded that active responses reduce the impact forces experienced at the hip and shoulder in falls to the side. Decreased effectiveness of protective responses, due to increases in reaction time and decreases in strength with age, may help explain why so many hip fractures occur in the elderly but so few occur in younger people.

Accidental Falls↗

Pathomechanics and clinical relevance of disc degeneration and annular tear: a point-of-view review.

Annular tear is a major cause of intervertebral disc degeneration that results in disabling back pain. Many of the stresses resulting in this type of lesion are common in the workplace: compression, torsion, compression combined with flexion, and vibration. Age-related disc degeneration begins early in adulthood, and progresses thereafter, altering disc morphology and mechanical properties in ways that predispose to disc herniation, and should not be misconstrued as "old age." Acute trauma may produce disc herniation whether or not there are predisposing factors, such as age-related degeneration, but disc herniation in the absence of acute injury requires the presence of preexisting degenerative changes.

Biomechanical Phenomena↗

The pathomechanism of isthmic lumbar spondylolisthesis. A biomechanical study in immature calf spines.

STUDY DESIGN: Anterior shearing force was applied to immature calf lumbar functional spinal units until failure. OBJECTIVES: To clarify the mechanism of slippage in immature calf lumbar spines with pars defects as a first step to understand the mechanism of spondylolisthesis in pediatric human lumbar spines. SUMMARY OF BACKGROUND DATA: Progression from lysis to olisthesis occurs during the adolescent growth spurt. However, the mechanism of slippage in the immature lumbar spine has not yet been understood clearly. METHODS: Bilateral pars defects were created at the rostral vertebra. The specimens then were assigned to one of the two groups: functional spinal units with intact disc (n = 5) and with disc dissected (n = 5). In the former group, the disc was left intact, whereas in the disc dissected group, the anterior longitudinal ligament and 75% of the anterior-to-posterior depth of the disc were incised along the mid-disc plane. Using a uniaxial MTS machine (MTS System, Minneapolis, MN), anteroposterior shearing force was applied to each specimen. Failure load and displacement at failure were calculated from the load--displacement curve. Failure sites also were assessed radiographically and histologically. RESULTS: The five functional spinal units in the intact disc group failed at 973.8 +/- 78.1 N, whereas specimens in the disc dissected group failed at 986.4 +/- 124.2 N. The data showed no significant differences between the two groups. All the specimens showed displacement through the growth plates on radiographs. Histologically, failure was observed to occur between the superior growth plate and osseous endplate of caudal vertebra, indicating that this site is the weakest link. CONCLUSIONS: The results suggest that in the pediatric immature lumbar spine with pars defects, slippage may occur between the growth plate and osseous endplate.

Animals↗

Prediction of load sharing among spinal components of a C5-C6 motion segment using the finite element approach.

STUDY DESIGN: A finite element model of the ligamentous cervical spinal segment was used to compute loads in various structures in response to clinically relevant loading modes. OBJECTIVE: To predict biomechanical parameters, including intradisc pressure, tension in ligaments, and forces across facets that are not practical to quantify with an experimental approach. SUMMARY OF BACKGROUND DATA: Finite element models of the cervical spine in their present form, because of inherent assumptions and simplifications, are not entirely satisfactory for studying the biomechanics of the intact, injured, and stabilized cervical spinal segment. METHODS: A three-dimensional finite element model of a C5-C6 motion segment was developed from serial computed tomographic scans of a ligamentous cervical spinal segment. This model included nonlinear ligament definition, fully composite intervertebral disc, fluid nucleus, and Luschka's joints. The model-based displacement predictions were in agreement with the experimental data. This model was used to predict load sharing and other related parameters in spinal elements in response to various loading modalities. RESULTS: In axial compression, 88% of the applied load passed through the disc. The interspinal ligament experienced the most strain (29.5%) in flexion, and the capsular ligaments were strained the most (15.5%) in axial rotation. The maximum intradisc pressure was 0.24 MPa in the flexion with axial compression mode (1.8 Nm + 73.6 N). The anterior and posterior disc bulges increased with the increase in axial compression (up to 800 N). CONCLUSIONS: The results provide new insight into the role of various elements in transmitting loads. The model represents significant and essential advancement in comparison with previous finite element models, making it possible for such models to be used in investigating a broad spectrum of clinically relevant issues.

Biomechanical Phenomena↗

Biomechanical testing sequelae relevant to spinal fusion and instrumentation.

The increasing prevalence of spinal disorders and associated treatments has produced a dramatic increase in the number of available devices. The biomechanical evaluation leading to the design, development, and implementation of spinal instrumentation has resulted in a number of in vitro and in vivo testing methods. This article reviews some of the methods and associated results obtained by various evaluation techniques of spinal fusion hardware. Current work and future considerations also are presented.

Animals↗

Prediction of biomechanical parameters in the lumbar spine during static sagittal plane lifting.

A combined approach involving optimization and the finite element technique was used to predict biomechanical parameters in the lumbar spine during static lifting in the sagittal plane. Forces in muscle fascicles of the lumbar region were first predicted using an optimization-based force model including the entire lumbar spine. These muscle forces as well as the distributed upper body weight and the lifted load were then applied to a three-dimensional finite element model of the thoracolumbar spine and rib cage to predict deformation, the intradiskal pressure, strains, stresses, and load transfer paths in the spine. The predicted intradiskal pressures in the L3-4 disk at the most deviated from the in vivo measurements by 8.2 percent for the four lifting cases analyzed. The lumbosacral joint flexed, while the other lumbar joints extended for all of the four lifting cases studied (rotation of a joint is the relative rotation between its two vertebral bodies). High stresses were predicted in the posterolateral regions of the endplates and at the junctions of the pedicles and vertebral bodies. High interlaminar shear stresses were found in the posterolateral regions of the lumbar disks. While the facet joints of the upper two lumbar segments did not transmit any load, the facet joints of the lower two lumbar segments experienced significant loads. The ligaments of all lumbar motion segments except the lumbosacral junction provided only marginal moments. The limitations of the current model and possible improvements are discussed.

Biomechanical Phenomena↗

Influence of iron on growth and extracellular products of Acinetobacter baumannii.

Iron is an important nutrient required by bacteria for optimal growth. Acquisition of iron from the host where iron is restricted is an important mediator of bacterial pathogenesis. In iron deplete chemically defined medium (CDM-Fe) growth of Acinetobacter baumannii was restricted as compared to iron replete medium (CDM + Fe). Bacteria developed four high molecular weight outer membrane proteins (OMPs) of 88, 84, 80 and 77 kDa in CDM-Fe medium which were absent in CDM + Fe medium, and are known iron regulated outer membrane proteins (IROMPs). A. baumannii secreted siderophores extracellularly into the medium which act as iron chelators which had been demonstrated in the supernatants of CDM-Fe media. The siderophore was of catechol type. This shows that A. baumannii under iron restricted conditions express IROMPs along with production of catechol type siderophore in order to acquire iron from the external milieu.

Acinetobacter↗