Search PubMed⌕ Search

Biomedical subjects

V Honrubia

Publications and source records attributed to V Honrubia.

At least 145 records · Page 8Linked to original sources

Linear model for visual-vestibular interaction.

The results of experiments are evaluated in terms of a simple model for the interaction of eye movement responses to simultaneous optokinetic and vestibular stimuli. The model predictions agree with the results of these experiments and explain many clinical observations concerning the effect of vision on nystagmus. The model accounts for the dominance of the visual system's response over the vestibular system's response at low frequencies. It also accounts for the inability of patients with decreased smooth pursuit system response to suppress the vestibulo-ocular reflex during simultaneous optokinetic and vestibular stimulations. The model provides useful information for the design of combined optokinetic and vestibular stimuli for test vestibulo-ocular reflexes.

Eye Movements↗

Vestibular-optokinetic interactions in normal subjects and in patients with peripheral vestibular dysfunction.

The vestibulo-ocular reflex (VOR) during rotation, optokinetic nystagmus (OKN), and interactions between the vestibulo-ocular and optokinetic systems were studied quantitatively in 10 normal human subjects, 15 patients with unilateral horizontal semicircular canal paralysis (UP), and 11 patients with bilateral horizontal semicircular canal paralysis (BP). The OKN gain (eye velocity/drum velocity) was not significantly different between the normal subjects and the patient groups. During tests in which rotatory and visual stimuli were presented simultaneously, the contribution to the observed eye movements by the VOR was only one-fourth to one-third of its gain during rotation in the dark in the normal subjects and UP patients. These interactive tests did not differentiate UP patients from normal subjects but did separate BP patients from normal subjects.

Adult↗

Cerebellar-pontine angle tumors. Results of quantitative vestibulo-ocular testing.

A new quantitative vestibulo-ocular test battery was evaluated in 12 patients with surgically confirmed cerebellar-pontine angle tumors. The battery consisted of precise vestibular and visual stimuli and digital computer analyses of responses. Eleven of 12 patients, including all patients with acoustic neurolemmomas, had significant vestibular deficits on the tumor side (P less than .01). Contrary to previous reports, rotatory tests (impulse and sinusoidal acceleration) reliably identified the side and magnitude of vestibular deficit. Eight of nine patients with surgically confirmed brain stem compression had significantly impaired smooth pursuit (P less than .05). Optokinetic nystagmus was impaired in five of nine patients with brain stem compression (P less than .05). By combining the results of the entire test battery with standard clinical evaluation, a good prediction of tumor size, location, and type was possible.

Adolescent↗

Rapid eye movements in myasthenia gravis. II. Electro-oculographic analysis.

Voluntary saccades were studied by electro-oculography in ten patients with myasthenia gravis (MG) and in eight patients with other types of ophthalmoplegia. Despite limited range of eye movements, maximum velocities of 20 degree and 40 degree saccades in patients with MG were not significantly different from those in normal individuals, whereas maximum velocities in patients with other types of ophthalmoplegia were significantly decreased. In some myasthenic patients, small amplitude saccades were hypermetric and had high velocities, appearing clinically as "quiver" movements characteristic of MG. In MG the preservation of saccades with high initial velocities, even in the presence of severe ophthalmoplegia, suggests that muscle fibers generating rapid movements during saccades (twitch fibers) can be relatively spared when muscle fibers responsible for maintenance of excentric gaze (tonic fibers) are severely affected.

Adolescent↗

Effective stimulus for the Xenopus laevis lateral-line hair-cell system.

An in vitro preparation of the lateral-line organ of the African clawed toad Xenopus laevis was used to evaluate the properties of the physiological stimuli which are most effective in evoking neural responses in this simple hair-cell system. Changes in the mean firing rate and the amount of modulation of the neural activity in the fibers innervating the hair cells were determined during the presentation of well-controlled pressure or water-movement stimuli in a specially designed chamber that prevented movement and deformation of the organ during stimulation. It was shown that the most effective stimulus for the preparation was a varying flow of fluid past the organ. Sinusoidally varying water movements over a frequency range of 1 to 100 Hz were effective in evoking neural responses at stimulus amplitudes less than 10 mu peak-to-peak; in addition, a small response to a constant-velocity flow was found. Since no movement or deformation of the organ was present during the water-movement stimuli, it was concluded that these aspects of normal physiological stimuli were not necessary to evoke neural responses. Finally, it was demonstrated that the preparation was sensitive to neither constant nor varying-pressure stimuli.

Action Potentials↗

Periodic alternating nystagmus.

Three patients with periodic alternating nystagmus (PAN) are described in detail. Digital computer methods were used to quantify their disordered eye movement in an attempt to understand the pathophysiology. One of the patients was unusual in showing rebound nystagmus with fixation and PAN without fixation. Each patient had hyperactive vestibular responses and the phase and gain of the PAN cycles were altered in a predictable fashion by vestibular stimuli. It is postulated that PAN represents cyclical firing between reciprocally connected groups of inhibitory neurons within the vestibular and oculomotor nuclei. The cyclical firing is initiated by a critical imbalance of tonic input to either group of normally functioning neurons.

Adult↗

Analysis of afferent responses from isolated semicircular canal of the guitarfish using rotational acceleration white-noise inputs. II. Estimation of linear system parameters and gain and phase spectra.

Quantitative estimates were computed for exponential coefficients and rate constants contributing to afferent unit impulse responses obtained from bundles innervating specific regions of the semicircular canal. The grouping of these estimates into specific response classes provided quantitative correlations with specific anatomical regions of innervation of the crista. Linear system gain and phase spectra were computed also, by applying Fourier transformations to unit impulse responses, for purposes of comparison with previous studies employing frequency domain analyses. Responses fitted by third-order linear system equations were specific to afferents innervating the crest and transition regions of the crista; whereas those fitted by overdamped, second-order equations were specific to afferents innervating the slopes and transition crista regions. It was concluded that strictly mechanical models of the transduction process are inadequate to account for the diverse and spatially distributed classes of observed responses and, moreover, structural features such as different hair cell types or efferent innervation effects could be excluded as inoperative in this preparation. The alternative hypothesis was suggested that certain of the observed subcomponents could be direct reflections of the initial mechanical stimulus, but that other subcomponents were reflections of more complex filtering mechanisms operating at the cellular or synaptic levels.

Animals↗

A study of congenital nystagmus: waveforms.

Eighteen patients with congenital nystagmus were studied with the techniques of electronystagmography and computer analysis. We found several complex wave forms of congenital nystagmus in the primary position of gaze above those of jerk and pendular nystagmus as defined clinically. An etiologic classification of motor fixation defect and sensory fixation defect nystagmus based on waveforms is not justified. Ocular tracking studies demonstrate that the smooth pursuit system is operational in congenital nystagmus and substantiate the belief that the fast component of jerk nystagmus is a corrective movement generated by the saccadic system. Patients with congenital nystagmus are able to produce voluntary saccades with normal velocity-amplitude relationships.

Adolescent↗

Algorithm for analyses of saccadic eye movements using a digital computer.

An algorithm for digital computer analyses of electro-oculographically recorded saccardic eye movements is presented. From a brief, 4-min recording session detailed statistical information about saccade velocity, accuracy, and delay time can be obtained. Since this data is not significantly altered by practice of motivational factors, it provides a sensitive functional test of the extra-ocular muscles and their brain control system.

Animals↗

On-line identification of sensory systems using pseudorandom binary noise perturbations.

A technique of on-line identification of linear system characteristics from sensory systems with spike train or analog voltage outputs was developed and applied to the semicircular canal. A pseudorandom binary white noise input was cross-correlated with the system's output to produce estimates of linear system unit impulse responses (UIRs), which were then corrected for response errors of the input transducers. The effects of variability in the system response characteristics and sensitivity were studied by employing the technique with known linear analog circuits. First-order unit afferent responses from the guitarfish horizontal semicircular canal were cross-correlated with white noise rotational acceleration inputs to produce non-parametric UIR models. In addition, the UIRs were fitted by nonlinear regression to truncated exponential series to produce parametric models in the form of low-order linear system equations. The experimental responses to the white noise input were then compared with those predicted from the UIR models linear convolution, and the differences were expressed as a percent mean-square-error (%MSE). The average difference found from a population of 62 semicircular canal afferents was relatively low mean and standard deviation of 10.2 +/- 5.9 SD%MSE, respectively. This suggests that relatively accurate inferences can be made concerning the physiology of the semicircular canal from the linear characteristics of afferent responses.

Animals↗

Quantitative measurement of saccade amplitude, duration, and velocity.

A method for rapid, accurate measurement of saccade amplitude, duration, and velocity (average and maximum) was developed as a functional test of the extraocular motor system. Recordings were made with a direct-current electro-oculographic system, and data analysis was performed on a laboratory digital computer. Saccade amplitude and duration were found to be linearly correlated in 25 normal subjects, with a mean slope of 2.7 msec per degree over a large amplitude range. In the same subjects, saccade amplitude and velocity (maximum or average) had a nonlinear relationship that was best fit by an exponential equation. The two constants of this equation adequately characterized the relationship between saccade amplitude and velocity and permitted rapid statistical comparison between normal and abnormal subjects.

Electrooculography↗

The saccade velocity test.

Scatter plots showing the amplitude versus velocity (maximum and average) relationship of horizontal saccades in 25 normal subjects and four groups of patients were statistically compared. Three patients with "subclinical" medial longitudinal fasciculus syndromes had significant slowing of adducting saccades, and two of these patients had unsuspected slowing of abducting saccades (although to a lesser degree). Five patients with olivopontocerebellar degeneration and three patients with myotonic dystrophy had significant slowing of saccades in both directions. Five patients with surgically documented acoustic neuromas did not have significant slowing despite brain-stem compression in three. It is concluded that the saccade velocity test can be a useful clinical tool in addition to its potential in clinical research.

Adult↗

Vestibulo-ocular function in patients with cerebellar atrophy.

Eye movement abnormalities were quantiatively assessed in four patients with clinically pure cerebellar atrophy (group A), six patients with brainstem plus cerebellar atrophy (group B), and five patients with Friedreich's ataxia (group C). Twelve patients had one or more types of spontaneous nystagmus; eight gaze nystagmus, three rebound nystagmus, wo positional nystagmus, and one vestibular nystagmus. Catoric-induced and rotatory-induced nystagmus was hyperactive in group A and diminished in group C. Group B had mixed responses. All patients demonstrated significant fixation instability and impaired smooth pursuit. There was dysmetria of voluntary saccades, with flutter and "rebound" saccades. Nine of 15 patients had significant slowing of induced saccades, including two patients in group A. It is concluded that quantitative vestibulocular tests can be useful in classifying the cerebellar atrophy syndromes.

Cerebellar Ataxia↗

Algorithm for the multi-parameter analysis of nystagmus using a digital computer.

A computer program for analyzing nystagmus has been developed and can be used on a small laboratory digital computer. The algorithm accepts digitized data and looks for the minimum and maximum (minmax) points of the nystagmus waveform. These points in turn are used to define seven descriptive parameters of nystagmus, including the amplitude, duration, and velocity of the slow and fast phases, and the frequency. The algorithm uses three user-adjusted criteria for accepting or rejecting minmax points. The treatment of noisy or irregular data can be improved by adjusting the values of these criteria.

Computers↗