Biomechanics of compression plating.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to V C Mow.
Explore the source record for details and available documents.
Surface fibrillation of articular cartilage is an early sign of degenerative changes in the development of osteoarthritis. To assess the influence of the surface zone on the viscoelastic properties of cartilage under compressive loading, we prepared osteochondral plugs from skeletally mature steers, with and without the surface zone of articular cartilage, for study in the confined compression creep experiment. The relative contributions of two viscoelastic mechanisms, i.e. a flow-independent mechanism [Hayes and Bodine, J. Biomechanics 11, 407-419 (1978)], and a flow-dependent mechanism [Mow et al. J. biomech. Engng 102, 73-84 (1980)], to the compressive creep response of these two types of specimens were determined using the biphasic poroviscoelastic theory proposed by Mak. [J. Biomechanics 20, 703-714 (1986)]. From the experimental results and the biphasic poroviscoelastic theory, we found that frictional drag associated with interstitial fluid flow and fluid pressurization are the dominant mechanisms of load support in the intact specimens, i.e. the flow-dependent mechanisms alone were sufficient to describe normal articular cartilage compressive creep behavior. For specimens with the surface removed, we found an increased creep rate which was derived from an increased tissue permeability, as well as significant changes in the flow-independent parameters of the viscoelastic solid matrix. permeability, as well as significant changes in the flow-independent parameters of the viscoelastic solid matrix. From these tissue properties and the biphasic poroviscoelastic theory, we determined that the flow-dependent mechanisms of load support, i.e. frictional drag and fluid pressurization, were greatly diminished in cartilage without the articular surface. Calculations based upon these material parameters show that for specimens with the surface zone removed, the cartilage solid matrix became more highly loaded during the early stages of creep. This suggests that an important function of the articular surface is to provide for a low fluid permeability, and thereby serve to restrict fluid exudation and increase interstitial fluid pressurization. Thus, it is likely that with increasing severity of damage to the articular surface, load support in cartilage under compression shifts from the flow-dependent modes of fluid drag and pressurization to increased solid matrix stress. This suggests that it is important to maintain the integrity of the articular surface in preserving normal compressive behavior of the tissue and normal load carriage in the joint.
In 1990, Holmes and Mow [Journal of Biomechanics 23, 1145-1156] developed a hyperelastic biphasic theory to describe finite deformation behaviors of articular cartilage. To date, however, no experimental finite deformation studies have been made to assess the ability of this constitutive model to describe its finite deformation behaviors (e.g. kinetic creep and stress-relaxation, and equilibrium responses). The objectives of this study are: (1) to investigate whether this hyperelastic biphasic theory can be used to curve-fit the finite deformation compressive stress-relaxation behavior of the tissue, and from this procedure, to calculate its material coefficients; and (2) to investigate whether the theory, together with the calculated material coefficients, can accurately predict the outcome of an independent creep experiment followed by cyclical loading of the tissue. To achieve these objectives, circular cylindrical cartilage plugs were tested in confined compression in both stress-relaxation and creep experiments. Results demonstrated that curve-fits of the stress-relaxation experiments produced nonlinear generalized correlation coefficients of r2 = 0.99 +/- 0.02 (mean +/- standard deviation); theoretical predictions of the creep test differed on average by 10.0% +/- 2.0% relative to experimental results. When curve-fitting the creep experiments as well, it was found that the permeability coefficients differed from those obtained from the stress-relaxation experiments (k0,cr = 2.2 +/- 0.8 x 10(-15) m4 N-1 s-1 and Mcr = 0.4 +/- 0.8 vs k0,sr = 2.7 +/- 1.5 x 10(-15) m4 N-1 s-1, and Msr = 2.2 +/- 1.0); these differences may be attributed to imprecisions in the curve-fitting procedure stemming from the low sensitivity of the stress-relaxation and creep behaviors to large variations of M in the permeability function. Advantages and limitations of this theoretical model are presented in the text.
The inferior glenohumeral ligament (IGHL) is an important structure for maintaining shoulder stability. This study was aimed at determining the geometric and anatomic characteristics of the IGHL and its tensile properties at a higher strain rate than previously tested. Eight fresh-frozen human cadaver shoulders (average age 69 years, age range 62 to 73 years) from four female and four male cadavers were used to harvest bone-ligament-bone specimens from the three regions of the IGHL (superior band, anterior axillary pouch, and posterior axillary pouch). Uniaxial tensile tests were performed at the moderately high strain rate of approximately 10% per second with a servo-hydraulic testing machine. This represented a strain rate that was approximately 100 to 1000 times faster than that previously reported. During tensile testing, bone-ligament-bone strains were calculated from grip-to-grip motion on the testing machine, and mid-substance strains were determined by a video dimensional analyzer. Although all regions of the IGHL had similar lengths (averaging 43.4 mm), their thickness varied by region and by proximal-to-distal location. The superior band was the thickest (2.23 +/- 0.38 mm) of the three regions. Of the remaining two regions the anterior axillary pouch (1.94 +/- 0.38 mm) was thicker than the posterior axillary pouch (1.59 +/- 0.64 mm). By proximal-to-distal location the IGHL was thicker for all three regions near the glenoid (2.30 +/- 0.57 mm) than near the humerus (1.61 +/- 0.52 mm). The superior band had a greater stiffness (62.63 +/- 9.78 MPa) than either the anterior axillary pouch (47.75 +/- 17.89 MPa) or the posterior axillary pouch (39.97 +/- 13.29 MPa). Tensile stress at failure was greater in the superior band (8.4 +/- 2.2 MPa) and the anterior axillary pouch (7.8 +/- 3.1 MPa) than the posterior axillary pouch (5.9 +/- 1.7 MPa). The anterior axillary pouch demonstrated greater bone-to-bone and mid-substance strains (30.4% +/- 4.3% and 10.8% +/- 2.4%, respectively) before failure than the other two regions (superior band: 20.8% +/- 3.8% and 9.1% +/- 2.8%, respectively; posterior axillary pouch: 25.2% +/- 5.8% and 7.8% +/- 2.6%, respectively). Bone-to-bone strain was always greater than mid-substance strain, indicating that when the IGHL is stretched, the tissue near the insertion sites will experience much greater strain than the tissue in the mid-substance. insertion failures were more likely at slower strain rates, and ligamentous failures were predominant at the fast strain rate. When compared with other tensile studies of the IGHL at slower strain rates (0.01% per second and 0.1% per second), the superior band and the anterior axillary pouch demonstrated the viscoelastic effects of increased stiffness and failure stress. This superior band and anterior axillary pouch pouch viscoelastic stiffening effect suggests that these two regions may function to restrain the humeral head from rapid abnormal anterior displacement in the clinically vulnerable position of abduction and external rotation.
The American Shoulder and Elbow Surgeons have adopted a standardized form for assessment of the elbow. This form was developed by the Research Committee of the American Shoulder and Elbow Surgeons and subsequently adopted by the membership. The patient self-evaluation section contains visual analog scales for pain and a series of questions relating to function of the extremity. The responses to the questions are scored on a 4-point ordinal scale. The physician assessment section has 4 parts: motion, stability, strength, and physical findings. It is hoped that adoption of this method of data collection will stimulate multicenter studies and improve communication between professionals who assess and treat patients with elbow disorders.
The mechanical response of the inferior glenohumeral ligament to varying subfailure cyclic strains was studied in 33 fresh frozen human cadaver shoulders. The specimens were tested as bone-ligament-bone preparations representing the 3 regions of the inferior glenohumeral ligament (superior band and anterior and posterior axillary pouches) through use of uniaxial tensile cycles. After mechanical preconditioning, each specimen was subjected to 7 test segments, consisting of a baseline strain level L1 (400 cycles) alternating with either 1 (group A, 10 shoulders), 10 (group B, 13 shoulders), or 100 (group C, 10 shoulders) cycles at increasing levels (L2, L3, L4) of subfailure strain. Cycling to higher levels of subfailure strain (L2, L3, L4) produced dramatic declines in the peak load response of the inferior glenohumeral ligament for all specimens. The group of ligaments subjected to 100 cycles of higher subfailure strains demonstrated a significantly greater decrease in load response than the other 2 groups. Ligament elongation occurred with cyclic testing at subfailure strains for all 3 groups, averaging 4.6% +/- 2.0% for group A, 6.5% +/- 2.6% for group B, and 7.1% +/- 3.2% for group C. Recovery of length after an additional time of nearly 1 hour was minimal. The results from this study demonstrate that repetitive loading of the inferior glenohumeral ligament induces laxity in the ligament, as manifested in the peak load response and measured elongations. The mechanical response of the ligament is affected by both the magnitude of the cyclic strain and the frequency of loading at the higher strain levels. The residual length increase was observed in all of the specimens and appeared to be largely unrecoverable. This length increase may result from accumulated microdamage within the ligament substance, caused by the repetitively applied subfailure strains. The clinical relevance of the study is that this mechanism may contribute to the development of acquired glenohumeral instability, which is commonly seen in the shoulders of young athletes who participate in repetitive overhead sports activities.
Stereophotogrammetry was used to investigate the functional relations between the articular surface geometry, contact patterns, and kinematics of the glenohumeral joint. Nine normal shoulder specimens were elevated in the scapular plane by using simulated muscle forces in neutral rotation (NR) and starting rotation (SR). Motion was quantified by analyzing the translations of the geometric centers of the humeral head cartilage and bone surfaces relative to the glenoid surface. In both NR and SR, the ranges of translations of the center of the humeral head cartilage surface were greatest in the inferior-superior direction (NR 2.0 +/- 0.7 mm, SR 2.9 +/- 1.2 mm). Results of this study also show that joints with less congruence of the articular surfaces exhibit larger translations, and elevation in SR yields greater translations than in NR. Kinematic analyses with the humeral head bone surface data yielded larger values of translation than analyses that used the cartilage surface data, suggesting that similar overestimations may occur in radiographic motion studies. Results of this study demonstrate that small translations of the humeral head center occurred in both SR and NR. The proximity of the origin of the helical axes to the geometric center of the humeral head articular surface confirmed that glenohumeral elevation is mainly rotation about this geometric center with small translations.
This study characterizes the donor and recipient sites involved in osteochondral autograft surgery of the knee with respect to articular cartilage contact pressure, articular surface curvature, and cartilage thickness. Five cadaveric knees were tested in an open chain activity simulation and kinematic data were obtained at incremental knee flexion angles from 0 degrees to 110 degrees. Surface curvature, cartilage thickness, and contact pressure were determined using a stereophotogrammetry method. In all knees, the medial trochlea, intercondylar notch, and lateral trochlea demonstrated nonloadbearing regions. Donor sites from the distal-medial trochlea were totally nonloadbeadng. For the intercondylar notch, lateral trochlea, and proximal-medial trochlea, however, the nonloadbearing areas were small, and typical donor sites in these areas partially encroached into adjacent loadbearing areas. The lateral trochlea (77.1 m(-1)) was more highly curved than the typical recipient sites of the central trochlea (23.3 m(-1)), medial femoral condyle (46.8 m(-1)), and lateral femoral condyles (42.9 m(-1)) (P < 0.05). Overall, the donor sites had similar cartilage thickness (average, 2.1 mm) when compared with the typical recipient sites (average, 2.5 mm). The lateral trochlea and medial trochlea curvatures were found to better match the recipient sites on the femoral condyles, while the intercondylar notch better matched the recipient sites of the central trochlea. The distal-medial trochlea was found to have the advantage of being nonloadbearing. Preoperative planning using the data presented will assist in more conforming, congruent grafts, thereby maximizing biomechanical function.
Rehabilitation of the symptomatic patellofemoral joint aims to strengthen the quadriceps muscles while limiting stresses on the articular cartilage. Some investigators have advocated closed kinetic chain exercises, such as squats, because open kinetic chain exercises, such as leg extensions, have been suspected of placing supraphysiologic stresses on patellofemoral cartilage. We performed computer simulations on geometric data from five cadaveric knees to compare three types of open kinetic chain leg extension exercises (no external load on the ankle, 25-N ankle load, and 100-N ankle load) with closed kinetic chain knee-bend exercises in the range of 20 degrees to 90 degrees of flexion. The exercises were compared in terms of the quadriceps muscle forces, patellofemoral joint contact forces and stresses, and "benefit indices" (the ratio of the quadriceps muscle force to the contact stress). The study revealed that, throughout the entire flexion range, the open kinetic chain stresses were not supraphysiologic nor significantly higher than the closed kinetic chain exercise stresses. These findings are important for patients who have undergone an operation and may feel too unstable on their feet to do closed chain kinetic chain exercises. Open kinetic chain exercises at low flexion angles are also recommended for patients whose proximal patellar lesions preclude loading the patellofemoral joint in deeper flexion.
Nine fresh-frozen, human cadaveric shoulders were elevated in the scapular plane in two different humeral rotations by applying forces along action lines of rotator cuff and deltoid muscles. Stereophotogrammetry determined possible regions of subacromial contact using a proximity criterion; radiographs measured acromiohumeral interval and position of greater tuberosity. Contact starts at the anterolateral edge of the acromion at 0 degrees of elevation; it shifts medially with arm elevation. On the humeral surface, contact shifts from proximal to distal on the supraspinatus tendon with arm elevation. When external rotation is decreased, distal and posterior shift in contact is noted. Acromial undersurface and rotator cuff tendons are in closest proximity between 60 degrees and 120 degrees of elevation; contact was consistently more pronounced for Type III acromions. Mean acromiohumeral interval was 11.1 mm at 0 degrees of elevation and decreased to 5.7 mm at 90 degrees, when greater tuberosity was closest to the acromion. Radiographs show bone-to-bone relationship; stereophotogrammetry assesses contact on soft tissues of the subacromial space. Contact centers on the supraspinatus insertion, suggesting altered excursion of the greater tuberosity may initially damage this rotator cuff region. Conditions limiting external rotation or elevation may also increase rotator cuff compression. Marked increase in contact with Type III acromions supports the role of anterior acromioplasty when clinically indicated, usually in older patients with primary impingement.
The effect of long-term exercise on canine knees was studied to determine whether an increased level of lifelong weightbearing exercise causes degeneration, or changes that may lead to degeneration, of articular cartilage. Eleven dogs were exercised on a treadmill at 3 km/hr for 75 minutes 5 days a week for 527 weeks while carrying jackets weighing 130% of their body weight. Ten control dogs were allowed unrestricted activity in cages for the 550 weeks. At the completion of the study all knee joints were inspected for evidence of joint injury and degeneration. Articular cartilage surfaces from the medial tibial plateau were examined by light microscopy, the cartilage thickness was measured, and the intrinsic material properties were determined by mechanical testing. No joints had ligament or meniscal injuries, cartilage erosions, or osteophytes. Light microscopy did not demonstrate cartilage fibrillation or differences in safranin O staining of the tibial articular cartilages between the two groups. Furthermore, the tibial articular cartilage thickness and mechanical properties did not differ between the two groups. These results show that a lifetime of regular weightbearing exercise in dogs with normal joints did not cause alterations in the structure and mechanical properties of articular cartilage that might lead to joint degeneration.
The effects of patellar tendon adhesion on the knee extensor mechanism and on the kinematics and contact areas for both the patellofemoral and tibiofemoral joints were determined for five cadaveric knees in an open kinetic chain testing configuration. Patellar tendon adhesion decreased the distance from the inferior patellar pole to the tibial tuberosity, effectively creating patella infera. When compared with the controls, knees with adhesion had medial and distal translation of the patella, as well as increased patellar flexion. Although the patellar articular contact location shifted distally, the overall contact area did not change significantly. For the tibia, adhesion resulted in significant medial, proximal, and anterior translation, and internal rotation. Adhesion also resulted in a posterior shift of the tibial contact location. For the extensor mechanism, adhesion decreased the knee extension force created by the quadriceps muscle on the tibia, indicating a decrease in the effective moment arm of the extensor mechanism. Furthermore, as a result of patellar tendon adhesion, the angle formed by the quadriceps and patellar tendons decreased, suggesting an increase in patellofemoral joint reaction force with adhesion. The increased patellofemoral joint reaction force and the altered contact location may be related to anterior knee pain after knee trauma and knee surgery. Therefore, patients should be observed for subtle patella infera, which may indicate patellar tendon adhesion.