A discussion on the threshold limit for hemolysis related to Reynolds shear stress.

Turbulence-related damage to blood is a major problem with the use of prosthetic devices, such as mechanical heart valves. An often-cited paper by Sallam and Hwang (1984). Biorheology 21, 783-797) quantified the threshold for hemolysis to be about 400 N m(-2), a value that has hitherto contributed to the evaluation of the potential dangerousness of a medical implantable device. We propose a discussion of the mentioned experiment, based on the application of stress analysis concepts to the original measurements: this is necessary to assess the peak turbulence shear stress value that could have been found in Sallam and Hwangs experiment, with a suitable orientation of the measurement axes. The result of our theoretical discussion is that the threshold value of 400 N m(-2) could probably be considerably underestimated: following this point of view, a 3-D stress analysis shows that the peak turbulence shear stress at the inception of hemolysis should be at least 600 N m(-2). This result, obtained on the basis of the study of RBCs' response to a turbulent environment, indicates that blood particles are probably more resistant to short-time shear stresses than it was thought.

Blood Physiological Phenomena

Electromagnetic interference of digital and analog cellular telephones with implantable cardioverter defibrillators: in vitro and in vivo studies.

The present study examines the potential electromagnetic interference effects induced by cellular telephones on ICDs. We developed ad hoc protocols to conduct both in vitro and in vivo trials on most of the implantable cardioverter defibrillators available on the international market. Trials were conducted with three cellular telephones: two GSM (Global System for Mobile Communication) and one TACS (Total Access Communication System). A human trunk simulator was used to carry out in vitro observations on six ICDs from five manufacturers. In vivo tests were conducted on 13 informed patients with eight different ICD models. During the trials in air, GSM telephones induced interference effects on 4 out of the 6 cardioverter defibrillators tested. Specifically, pulse inhibition, reprogramming, false ventricular fibrillation, and ventricular tachycardia detections occurred, which would have entailed inappropriate therapy delivery had this been activated. Effects were circumscribed to the area closely surrounding the connectors. When the ICD was immersed in saline solution, no effects were observed. Three cases of just ventricular triggering with the interfering signal were observed in vivo.

Aged

Principal stress analysis in LDA measurement of the flow field downstream of 19-mm Sorin Bicarbon heart valve.

Heart valve replacement has become, since many years, a common surgical practice. Along with the improvement that the patients' health has derived from it, however, a certain amount of risk could not be avoided, bound to the inevitable hemodynamic disturbances that an artificial device generates. A major shortcoming, often reported, is the formation of thrombus on the edge of the prosthetic valve, with a possible obstruction of the orifices through which blood should normally flow undisturbed. Hemolysis is another possible consequence of the implantation of a mechanical heart valve, generally correlated to turbulence downstream of prosthetic heart valves (PHV). As it is agreed upon by many researchers, the risk of thrombogenicity or hemolysis is higher in those valves that are more subject to promote turbulence and flow separation in the flow through them. In the following paper, we present a study of the turbulence-related shear stress downstream of a bileaflet valve of minimum size (19 mm external diameter) Sorin Bicarbon. This size was chosen, accordingly to the Food & Drug Administration (FDA) draft guidance suggestion to investigate the worst case in turbulence promoted by PHVs, in order to have the highest velocity gradients and shear stresses for the FDA-stated cardiac output (6 1/min), related to maximum Reynolds number conditions. Velocity data were collected with the two-dimensional laser Doppler anemometry (LDA) technique; whereas this approach does not investigate directly all three components of the flow field, in the present case (bileaflet valves) it is not a limitation to the assessment of the maximum turbulence shear stress (TSS), thanks to the two-dimensional flow nature downstream of bileaflet models. Data taken in coincident mode were elaborated in order to determine the maximum shear stress in the measured points in the flow field, using the 2D Principal Stress Analysis (PSA). The consequences of a variable principal normal stress direction all along the measured profile will be illustrated in terms of differences between measured and maximum shear stresses. Results show the need to estimate the maximum values for the TSS and the direction along which it is obtained to correctly define the turbulent flow field downstream of PHVs.

Blood Flow Velocity

A portable unit for remote monitoring of pacemaker patients.

The number of people with pacemakers has been steadily increasing over the past 20 years. At present there are about 2,500,000 in the world. All these patients must have a checkup twice a year in hospital, which involves the allocation of significant resources by the national health systems, not to speak of the inconvenience it entails for elderly subjects. Telemedicine can provide a partial solution to these problems. The present work describes a prototype system that transmits the patient's electrocardiograms and the main characteristics of the pacemaker to a monitoring centre. This remote monitoring system will be beneficial to patients and health-care organizations in terms of quality of life for the former, and costs and efficiency for the latter.

Electrocardiography, Ambulatory

A statistical approach to the quantitative comparison of pulsatile flow in vitro data of prosthetic heart valve testing.

BACKGROUND AND AIMS OF THE STUDY: In vitro evaluation and animal testing are fundamental steps in the assessment of prosthetic heart valves before their use in clinical practice. Valve testing under pulsatile conditions is the best in vitro simulation of cardiac valve function, and the ensuing results should support the surgeon's decision concerning the time of valve replacement. However, limits in hydraulic reproduction of cardiac function and differences in protocol implementation of in vitro testing lead to difficulties in obtaining reliable and comparable results. Debate among researchers and standardizing bodies about discrepancies in results becomes critical in light of the European CE certification of implantable medical devices. An interlaboratory environment has been created at the Biomedical Engineering unit of the Istituto Superiore di Sanita in Rome, which uses differing test apparatus to evaluate prosthetic heart valves in vitro, in order to define significant measurement parameters and procedures that produce comparative data. METHODS: Two prosthetic valves-a tilting disc and a bileaflet valve-each sized 29 mm, were tested in the aortic position on two different pulse duplicators (PDs), namely the Dynatek MP1 and a system developed at the University of Sheffield. The common protocol adopted was the FDA Interlaboratory Comparison Testing Protocol. Original software was used to manage all test phases, thus minimizing operator-dependent variability in both systems and imposing strict control of experimental conditions. Statistical analysis performed on the data followed two approaches: (i) separate fitting of the two regression equations of pressure drop-flow rate relationship obtained for each valve on both PDs, and (ii) application of a multiple regression model, to fit a single regression equation of pressure drop-flow rate relationship, using data obtained from both PDs for each valve. In addition, an additional independent (dummy) variable was introduced. RESULTS AND CONCLUSIONS: Using this approach, the valve parameter range was obtained and, by imposing strict control of the experimental set-up, the coincidence of the two valve power laws, estimated by each of the two PDs, was studied.

Heart Valve Prosthesis

19 mm sized bileaflet valve prostheses' flow field investigated by bidimensional laser Doppler anemometry (part I: velocity profiles).

The investigation of the flow field downstream of a cardiac valve prosthesis is a well established task. In particular turbulence generation is of interest if damage to blood constituents is to be assessed. Several prosthetic valve flow studies are available in literature but they generally concern large-sized prostheses. The FDA draft guidance requires the study of the maximum Reynolds number conditions for a cardiac valve model to assess the worst case in turbulence by choosing both the minimum valve diameter and a high cardiac output value as protocol set up. Within the framework of a national research project regarding the characterization of cardiovascular endoprostheses, the Laboratory of Biomedical Engineering is currently conducting an in-depth study of turbulence generated downstream of bileaflet cardiac valves. Four models of 19 mm sized bileaflet valve prostheses, namely St Jude Medical HP Edwards Tekna, Sorin Bicarbon, and CarboMedics, were studied in aortic position. The prostheses were selected for the nominal annulus diameter reported by the manufacturers without any assessment of the valve sizing method. The hemodynamic function was investigated using a bidimensional LDA system. Results concern velocity profiles during the peak flow systolic phase, at high cardiac output regime, highlighting the different flow field features downstream of the four small-sized cardiac valves.

Aortic Valve

19 mm sized bileaflet valve prostheses' flow field investigated by bidimensional laser Doppler anemometry (part II: maximum turbulent shear stresses)

The investigation of the flow field generated by cardiac valve prostheses is a necessary task to gain knowledge on the possible relationship between turbulence-derived stresses and the hemolytic and thrombogenic complications in patients after valve replacement. The study of turbulence flows downstream of cardiac prostheses, in literature, especially concerns large-sized prostheses with a variable flow regime from very low up to 6 L/min. The Food and Drug Administration draft guidance requires the study of the minimum prosthetic size at a high cardiac output to reach the maximum Reynolds number conditions. Within the framework of a national research project regarding the characterization of cardiovascular endoprostheses, an in-depth study of turbulence generated downstream of bileaflet cardiac valves is currently under way at the Laboratory of Biomedical Engineering of the Istituto Superiore di Sanita. Four models of 19 mm bileaflet valve prostheses were used: St Jude Medical HP, Edwards Tekna, Sorin Bicarbon, and CarboMedics. The prostheses were selected for the nominal Tissue Annulus Diameter as reported by manufacturers without any assessment of valve sizing method, and were mounted in aortic position. The aortic geometry was scaled for 19 mm prostheses using angiographic data. The turbulence-derived shear stresses were investigated very close to the valve (0.35 D0), using a bidimensional Laser Doppler anemometry system and applying the Principal Stress Analysis. Results concern typical turbulence quantities during a 50 ms window at peak flow in the systolic phase. Conclusions are drawn regarding the turbulence associated to valve design features, as well as the possible damage to blood constituents.

Aortic Valve

Electromagnetic interference of analog cellular telephones with pacemakers.

The aim of this study was to verify whether there is a public health risk from the interference of analog cellular telephones with pacemakers. We used a human trunk simulator to reproduce an actual implant, and two cellular telephones working with the TACS (Total Access Communication System) standard. Results showed that the electromagnetic field radiated from the analog cellular telephones interfered with a large number of the pacemakers tested (10/25). When the telephone antenna was in close proximity to the pacemaker head, pacemaker desensitizing and sensitizing and pulse inhibition was detected at the moment of an incoming call and throughout ringing. In the worst case of pulse inhibition, the pacemaker skipped three nonconsecutive beats and then resumed its normal pacing, while the desensitizing and sensitizing phenomena persisted as long as the interfering signal was on. Pulse inhibition was also observed when the connection did not succeed. Maximum sensing threshold variation was about 186% (increase) and 62% (decrease) for desensitizing and sensitizing phenomena, respectively. It was also demonstrated that the signal emitted by analog cellular telephones during the crossing of contiguous cells could induce pacemaker pulse inhibition, but under our experimental conditions this event did not seem to pose a risk for the pacemaker patient.

Electromagnetic Fields

A simplified system to develop precision master models.

Master model construction using a plexiglass base is a procedure used in many dental laboratories. The following technique uses the Compact System to create a precision master model. This system is functionally superior to pour and base techniques because of its improved precision, better placement and improved cleanliness of the holes that receive the dowel pins.

Dental Casting Technique

Evaluation of tilting disc valves after fatigue life testing: preliminary results within a comparison program.

A fatigue life test, by accelerating the beat rate, simulates several years of virtual life of a prosthetic heart valve in a short period of time. The correlation between the in vivo life of a valve and in vitro testing expectations is as yet not well established, but reproducible test conditions yield precious information about wear and failure. The paper reports a qualitative analysis of mechanical valve wear as part of a comparison program designed to investigate the significance of fatigue testing with the ultimate aim of defining standard guidelines for these type of tests. Two tilting disc valves (29 mm) were subjected to 16 years of fatigue life simulated by means of a Rowan Ash fatigue tester (accelerated rate of 1,200 bpm). Fatigue-induced effects on valve disc and ring surfaces were observed under a monitor microscope to identify wear sites and patterns. A high speed cinematographic system was used to investigate the mechanisms responsible for the wear (wear modes). Valve closure was inspected at a 6,000 frame/s rate. Because of disc rotation during the tilting movement, the points of contact between disc and ring are distributed all around the disc edge but focally on the ring. On both sides of the disc, the surfaces present ring-like concentric grooves. After 16 years of fatigue life the valves showed neither severe wear nor alteration of their fluidodynamic behavior in the pulsatile flow test.

Biomechanical Phenomena

Do European GSM mobile cellular phones pose a potential risk to pacemaker patients?

A series of in vivo trials were carried out in order to verify whether the electromagnetic field radiated by GSM (Groupe Systemes Mobiles) mobile cellular phones might affect implanted pacemakers. Two European GSM phones of 2-watt power were tested and trials conducted on 101 pacemaker implanted outpatients attending day hospital for routine check-up, who volunteered for trials. Forty-three pacemaker models from 11 manufacturers were tested in all. When the sensing threshold of the pacemakers was set at a minimum and the antenna of the phone was in direct contact with the patient's chest, interference was detected for 26 implanted pacemakers. Specifically, pulse inhibition in 10 of 101 cases, ventricular triggering in 9 of 46 DDD-VDD pacemakers, and asynchronous pacing in 4 of 52 devices. Pulse inhibition was also observed combined with asynchronous pacing in 1 of 52 cases and with ventricular triggering in 2 of 46 cases. Minimum effect duration was ca. 3 seconds but in 6 cases effects continued as long as the interfering GSM signal was on. No permanent malfunctioning or changes in the programmed parameters were detected. Whenever interference was detected, trials were repeated to determine the maximum sensing threshold at which interference persisted (with the antenna in contact with the skin over the pacemaker). Then maximum distance between antenna and pacemaker at which interference occurred was determined at pacemaker maximum and minimum sensing threshold. Under our experimental conditions electromagnetic interference effects were detected at a maximum distance of 10 cm with the pacemaker programmed at its minimum sensing threshold.(ABSTRACT TRUNCATED AT 250 WORDS)

Electricity

New algorithm for the detection of the ECG fiducial point in the averaging technique.

The use of the coherent averaging technique applied to the electrocardiographic signal implies the location of a fiducial point as a synchronisation reference. An algorithm easily adaptable to a personal computer, operable in real time, insensitive to mains and to ECG-baseline fluctuations, with a low jitter value and the capacity to trigger any ECG signal wave or complex, has been developed. The algorithm detects those waveforms which, within certain confidence intervals, are morphologically equal to a reference wave. This wave is chosen by the user as the repetitive waveform within which the fiducial point is to be located. A two-window template and differential parameters are used. The possibility of building the template permits the user to adapt the algorithm to each patient's ECG. To evaluate its accuracy objectively, a software simulation was built of a generator capable of producing test signals as the sum of the 'useful' signal plus 'noise'. A jitter standard deviation of 1.65 ms was obtained in the worst test (SNR = 10 dB; noiseband = 0-50 Hz), which shows the excellent recognition accuracy of the algorithm.

Algorithms

Prosthetic heart valve evaluation in vitro: critical aspects of data comparability.

The technology of heart valve substitution has considerably improved in the last few years, but its reliability after implantation is still not good enough, hence the need to study new valve design and improve quality testing. Different pulse duplicators are used for heart valve testing, but the results depend very much on the system adopted and the measurement protocol. Tests on two pulse duplicators currently used at the Biomedical Engineering Laboratory at the Istituto Superiore di Sanità, Rome, are reported here. The most significant parameters for valve evaluation were measured following each system's own protocol. Attention was focused on vascular load tuning when setting up the system and on the relationship between drive unit flow waveform and valve regurgitation and energy loss measurements. Standardization criteria must be defined in order to ensure the reliable comparability of in vitro testing results.

Coronary Circulation

Pacemaker registration electronic-card. A proposal for a computerised system of storing of the pacemaker registration card.

This paper describes an example of a computerised system dedicated to store an Emergency Health Card into a compact and portable memory support such as the CMOS RAM CARD. Details are given from the system used and of the program developed for this task. In particular, patient, pacemaker and lead data are stored by the prototype system. The acquisition layout is similar to that of the European pacemaker registration card but some other sections are added. The possibilities of an introduction of a card system like this on E.E.C. countries is discussed.

Computer Systems

Implant effects on polyurethane and silicone cardiac pacing leads in humans: insulation measurements and SEM observations.

Recently, polyurethane cardiac pacing leads have been under discussion because of some failures, probably due to modification of surface insulating properties. In order to verify the reliability of polyurethane versus silicone rubber as coating material, the authors, starting from previous clinical research, have carried out a study of electrical insulation related to implant time. At the same time the outer and inner lead surfaces have been submitted to scanning electron microscope (SEM) analysis. The results show, for the polyurethane leads, a significant increase in the leakage or currents in explanted samples, and a significant degradation (cracking) of the outer surfaces.

Electric Conductivity