Search PubMed⌕ Search

Biomedical subjects

V A Umans

Publications and source records attributed to V A Umans.

34 records · Page 2Linked to original sources

Mechanisms of luminal enlargement and quantification of vessel wall trauma following balloon coronary angioplasty and directional atherectomy.

OBJECTIVES: The purpose of this study was to assess the dual action of lumen enlargement and vessel wall damage following either balloon angioplasty or directional atherectomy, using intracoronary ultrasound, and angioscopy. BACKGROUND: Differences in the mechanisms of action of balloon angioplasty and directional atherectomy may have a significant bearing on the immediate outcome and the restenosis rate at 6 months. METHODS: A total of 36 patients were studied before and after either balloon angioplasty (n = 18) or directional atherectomy (n = 18). Ultrasound measurements included changes in lumen area, external elastic membrane area and plaque burden. In addition, the presence and extent of dissections were assessed to derive a damage score. Angioscopic assessment of the dilated or atherectomized stenotic lesions was translated into semi-quantitative dissection, thrombus and haemorrhage scores. RESULTS: Atherectomy patients had a larger angiographic vessel size compared with the angioplasty group (3.55 +/- 0.46 mm vs 3.00 +/- 0.64 mm, P < 0.05); however, minimal lumen diameter (1.18 +/- 0.96 mm vs 0.85 +/- 0.49 mm) and plaque burden (17.04 +/- 3.69 vs 15.23 +/- 4.92 mm2) measurements did not differ significantly. As a result of plaque reduction, atherectomy produced a larger increase in luminal area than the angioplasty group (5.80 +/- 1.78 mm2 vs 2.44 +/- 1.36 mm2, P < 0.0001). Lumen increase after angioplasty was the result of 'plaque compression' (50%) and wall stretching (50%). Additionally, in both groups there was indirect angioscopic evidence of thrombus 'microembolization' as an adjunctive mechanism of lumen enlargement. Angioscopy identified big flaps in six and small intimal flaps in 11 of the atherectomized patients as compared with five and 12 patients in the angioplasty group. Changes in thrombus score following both coronary interventions were identical (0.72 +/- 3.42 points atherectomy vs -0.38 +/- 3.27 points balloon angioplasty, ns). CONCLUSIONS: Lumen enlargement after directional atherectomy is mainly achieved by plaque removal (87%), whereas balloon dilation is the result of vessel wall stretching (50%) and plaque reduction (50%). Despite the fact that the luminal gain achieved by directional atherectomy is twice that achieved with balloon angioplasty, the extent of trauma induced by both techniques seems to be similar.

Aged↗

Acute and long-term outcome of directional coronary atherectomy for stable and unstable angina.

The clinical efficacy and safety of directional coronary atherectomy for the treatment of stable and unstable angina were assessed in 82 patients with stable and 68 patients with unstable angina. Therefore, clinical and angiographic follow-up was obtained in a prospectively collected consecutive series of 150 atherectomy procedures. Restenosis was assessed clinically and by quantitative angiography. The overall clinical success rate of atherectomy for patients with unstable and stable angina was 88% and 91%, respectively. No significant differences were found for in-hospital event rates between the unstable and stable angina groups: death (1.5% vs 0%), myocardial infarction (10% vs 6%), and emergency bypass operation (3% vs 2%). These clinical events were related to the occurrence of abrupt occlusions (8.8% in patients with stable and 6.1% in those with unstable angina; p = NS). Clinical follow-up was achieved in 100% of the patients with stable and unstable angina at a mean interval of 923 and 903 days, respectively. Two-year survival rates were 96% and 97% in the populations with unstable and stable angina, respectively. There were no significant differences with respect to bypass surgery and angioplasty, but event-free survival at 2 years was significantly lower in the unstable (54%) than the stable (69%) angina group. Quantitative coronary angiography did not detect any difference in luminal renarrowing during the 6-month angiographic follow-up period. Although directional coronary atherectomy can be performed effectively in patients with unstable and stable angina, the long-term clinical outcome was less favorable in the unstable angina group.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

Optimal use of directional coronary atherectomy is required to ensure long-term angiographic benefit: a study with matched procedural outcome after atherectomy and angioplasty.

OBJECTIVES: This study was designed to examine whether restenosis is related to the extent or mechanism of lumen improvement and to explore angiographic determinants of optimal atherectomy. BACKGROUND: Directional atherectomy induces a greater extent of immediate gain and late loss but has not been found to yield a better late angiographic lumen than angioplasty in randomized trials. The difference in lumen renarrowing may be related to either the extent or the mechanism of immediate gain. The design of previous studies has precluded the detection of a device-specific effect on restenosis. METHODS: A retrospective analysis was based on matching a prospectively collected series of 80 native coronary arteries successfully treated with atherectomy with a prospectively collected series of 80 native coronary arteries successfully treated with balloon angioplasty. Angiographic analysis was performed in 160 lesions to explore whether a specific device-related effect exists. Multivariate analyses were performed to determine the correlates of minimal lumen diameter at follow-up and late lumen loss and to identify the procedural characteristics for optimal atherectomy. RESULTS: Matching resulted in two comparable groups with equivalent baseline clinical and stenosis characteristics. By study design, atherectomy and angioplasty resulted in similar mean (+/- SD) immediate lumen gain (1.15 +/- 0.44 vs. 1.10 +/- 0.40 mm, p = 0.50). However, lumen loss was more pronounced after atherectomy, and, thus, the minimal lumen diameter at follow-up differed significantly between the two groups (1.78 +/- 0.57 vs. 2.00 +/- 0.56 mm, p = 0.001). Device type was retained in the multivariate analysis as an independent predictor of late minimal lumen diameter and lumen loss. Multivariate analysis identified vessel size and immediate gain as determinants of optimal atherectomy. CONCLUSIONS: Restenosis is a consequence not only of the extent of lumen improvement but also of the mechanism of vessel wall injury (debulking vs. dilating). While performing atherectomy, the operator should strive for an optimal procedural result to accommodate an increased intimal hyperplastic response.

Angioplasty, Balloon↗

Clinical, histologic and quantitative angiographic predictors of restenosis after directional coronary atherectomy: a multivariate analysis of the renarrowing process and late outcome.

OBJECTIVES: To characterize predictors of restenosis after successful directional atherectomy, we reviewed the clinical, angiographic and procedural data obtained during 132 consecutive procedures. METHODS: Clinical and angiographic follow-up data were obtained in a prospectively collected and consecutive series of 125 patients who underwent 132 atherectomy procedures for de novo (89%) or restenotic (11%) lesions in native coronary arteries. Restenosis was assessed clinically and by quantitative coronary angiography. A dual approach to data analysis was taken to gain insight into factors affecting the clinical outcome and vessel wall healing response. Therefore, multivariate analysis was performed to 1) determine the correlates of residual lumen diameter at follow-up (angiographic outcome), and 2) characterize the determinants of the late lumen loss (renarrowing process). RESULTS: Clinical and angiographic follow-up data after successful atherectomy were obtained in 100% and 95%, respectively. Atherectomy achieved an acute lumen gain of 1.28 +/- 0.48 mm (mean +/- SD), resulting in a minimal lumen diameter of 2.44 +/- 0.47 mm. At follow-up, the minimal lumen diameter decreased to 1.78 +/- 0.64 mm. The angiographic restenosis rate was 28% if the traditional 50% stenosis cutoff criterion was applied. Larger vessel size and postatherectomy minimal lumen diameter and right coronary or left circumflex artery lesions were independent predictors of a larger minimal lumen diameter (angiographic outcome). Lumen loss during follow-up (renarrowing process) was independently predicted by relative lumen gain and preprocedural minimal lumen diameter. CONCLUSIONS: In analyzing the long-term results of new interventional techniques such as directional atherectomy, the late lumen loss during follow-up (renarrowing process), which is characterized by the vessel wall healing response after an intervention, should be considered together with the residual lumen diameter at follow-up (clinical outcome). It is clear that whereas improved clinical outcome is associated with larger vessel size and postprocedural lumen diameter and non-left anterior descending artery location, greater relative gain at intervention is predictive of more extensive lumen renarrowing.

Aged↗

Proliferation and extracellular matrix synthesis of smooth muscle cells cultured from human coronary atherosclerotic and restenotic lesions.

OBJECTIVES: The purpose of this study was to examine the proliferative capacity and extracellular matrix synthesis of human coronary plaque cells in vitro. BACKGROUND: Common to both primary atherosclerosis and restenosis are vascular smooth muscle cell proliferation and production of extracellular matrix proteins. The applicability to humans of experimental animal models of these processes has been questioned. METHODS: Primary atherosclerotic and restenotic lesions were excised by percutaneous directional coronary atherectomy in 93 patients. Smooth muscle cells were cultivated by an explant technique and identified by their morphology in culture, ultrastructural features under electron microscopy and immunostaining using monoclonal antibodies to smooth muscle cell alpha-actin. Proliferation in secondary culture was assessed with growth curves and the synthesis of collagen and sulfated glycosaminoglycans by the incorporation of 3H-proline and 35S-sulfate, respectively. These studies were also performed in cells derived from human umbilical artery media. RESULTS: Success rates for primary (45%) and secondary (12%) culture of coronary cells were not influenced by clinical variables or lesion category. Primary culture success was improved by the presence of organized thrombus in the plaque and in relation to increased maximal cell density of the atherectomy specimen. Restenotic cells displayed more rapid growth than did cells of primary atherosclerotic origin, which grew in a manner similar to that of umbilical artery cells. Mean calculated population-doubling times for the three cell groups were 52 h (95% confidence interval [CI] 48 to 58 h), 71 h (95% CI 62 to 83 h) and 74 h (95% CI 65 to 84 h), respectively. Restenotic and primary atherosclerotic cells did not differ in the synthesis of collagen ([mean +/- SEM] 0.034 +/- 0.004 vs. 0.033 +/- 0.004 nmol isotope.microgram protein-1, p = NS) or sulfated glycosaminoglycans (11.47 +/- 1.07 vs. 15.37 +/- 3.10 nmol isotope.microgram protein-1, p = NS), but the coronary cells synthesized significantly more collagen and sulfated glycosaminoglycans than did umbilical artery cells (0.019 +/- 0.004 and 5.43 +/- 1.00 nmol isotope.microgram protein-1, respectively, both p < 0.05). CONCLUSIONS: These data indicate that increased smooth muscle cell proliferation contributes to coronary restenosis in humans and support the concept that the extracellular matrix synthesis of adult smooth muscle cells is important to lesion formation.

Cell Division↗

Restenosis after directional coronary atherectomy and balloon angioplasty: comparative analysis based on matched lesions.

OBJECTIVES: Late lumen narrowing after directional coronary atherectomy was assessed by quantitative coronary angiography and compared with that after balloon angioplasty. BACKGROUND: Directional coronary atherectomy has been introduced as an alternative technique for balloon angioplasty and may reduce the incidence of restenosis. METHODS: A prospectively collected consecutive series of 87 native coronary artery lesions successfully treated with atherectomy were matched with 87 coronary artery lesions selected from a consecutive series of lesions that had been successfully dilated by balloon angioplasty. Late angiographic analysis was performed in 158 lesions. The net gain index represents the ultimate gain in minimal lumen diameter at follow-up study, normalized for the vessel size. This index is the result of the relative gain attained during the procedure (the ratio of the change in minimal lumen diameter and reference diameter) and the relative loss observed during the follow-up period (the ratio of the change in minimal lumen diameter during the follow-up period and the reference diameter). RESULTS: Matching for clinical and angiographic variables resulted in two comparable groups with similar baseline stenosis characteristics. Atherectomy resulted in a more pronounced increase in minimal lumen diameter than did balloon angioplasty (mean +/- SD 1.17 +/- 0.29 to 2.44 +/- 0.42 mm vs. 1.21 +/- 0.38 to 2.00 +/- 0.36 mm, p < 0.001). However, this favorable immediate result was subsequently lost during late angiographic follow-up, so that the minimal lumen diameter at follow-up and the net gain index did not differ significantly between the two groups (1.76 +/- 0.62 vs. 1.77 +/- 0.59 mm, p = 0.93, and 0.18 +/- 0.19 vs. 0.17 +/- 0.17, p = 0.70). Consequently, the relative gain and relative loss were higher in the atherectomy group. For both techniques, the relative gain was linearly related to the relative loss but the slope of the regression line was steeper for atherectomy, suggesting that the relative loss in the atherectomy group is proportionally even larger for a given relative gain compared with that in the angioplasty group. CONCLUSIONS: In matched groups of patients, atherectomy induces a greater initial gain in minimal lumen diameter than does balloon angioplasty. However, the vascular wall injury induced by the device is of a different nature (debulking vs. dilating) that leads to more relative loss over the follow-up period in the atherectomy group.

Aged↗

The mechanism of directional coronary atherectomy.

An attempt was made to assess the mechanism of directional coronary atherectomy using different methods of analysis. Quantitative coronary angiography was used as the gold standard to assess the immediate results of atherectomy, and a comparative quantitative analysis of atherectomy and balloon angioplasty was made. To determine whether the post-atherectomy cross-sectional area is close to a circle, we compared the area measurements obtained by edge detection with those obtained by videodensitometry. Finally, the extent of a 'Dotter' effect was established by quantitative angiography following crossing the stenosis with the atherectomy device. For the purpose of this study, the results of the first 113 successful atherectomy procedures were reviewed. In matched lesions, directional atherectomy induced a greater increase in minimal luminal diameter than balloon angioplasty (1.6 mm vs 0.8 mm; P < 0.0001). However, this luminal improvement is due to a substantial 'Dotter' effect induced by the bulky atherectomy device. Following atherectomy, only a slight difference in cross-sectional area measurements between edge detection and videodensitometry (mean difference: 0.28 mm2) was found. Histologic examination of an atherectomized coronary artery showed a near-circular postatherectomy area geometry. In conclusion, directional atherectomy is a very effective device with a substantially better initial result than balloon angioplasty. However, insertion of this bulky device itself causes an important 'Dotter' effect.

Angioplasty, Balloon, Coronary↗

Clinical and histological determinants of smooth-muscle cell outgrowth in cultured atherectomy specimens: importance of thrombus organization.

BACKGROUND: Coronary atherectomy provides a unique opportunity to obtain plaque tissue from a wide variety of clinical syndromes. We investigated the relation between the clinical status and histopathological substrate of tissue retrieved during directional coronary atherectomy and the proliferative and migratory potential of smooth-muscle cells judged from successful outgrowth during cell culture. METHODS: After directional coronary atherectomy, tissue samples were examined macroscopically, divided into two equal pieces, and separately subjected to cell culture and histopathological study. Cell culture was performed using an explant technique. In-vitro smooth-muscle cell outgrowth was related to clinical and histological variables. RESULTS: Atherosclerotic tissue was obtained from 98 consecutive atherectomy procedures. Histological examination revealed a broad spectrum of appearances, ranging from complex atheroma containing dense fibrous tissue, calcium deposits, macrophages, and necrotic debris to neointimal proliferation and organized thrombi. Smooth-muscle cell outgrowth was observed in 43 of the 98 samples (44%). Although not affected by any of the clinical variables, cell outgrowth was influenced by histological variables, in particular the presence of organizing thrombi. Outgrowth was successful in eight out of 10 samples with thrombus (80%) and in only 35 out of 88 (40%) without (P = 0.03). CONCLUSION: The presence of organizing thrombi in the retrieved tissue facilitates smooth-muscle cell outgrowth and suggests an enhanced proliferative and migratory potential. These findings may be relevant to the understanding of neointimal proliferation in coronary syndromes where mural thrombosis is likely to occur.

Angina Pectoris↗

Directional atherectomy for treatment of restenosis within coronary stents: clinical, angiographic and histologic results.

OBJECTIVES: The safety and long-term results of directional coronary atherectomy in stented coronary arteries were determined. In addition, tissue studies were performed to characterize the development of restenosis. METHODS: Directional coronary atherectomy was performed in restenosed stents in nine patients (10 procedures) 82 to 1,179 days after stenting. The tissue was assessed for histologic features of restenosis, smooth muscle cell phenotype, markers of cell proliferation and cell density. A control (no stenting) group consisted of 13 patients treated with directional coronary atherectomy for restenosis 14 to 597 days after coronary angioplasty, directional coronary atherectomy or laser intervention. RESULTS: Directional coronary atherectomy procedures within the stent were technically successful with results similar to those of the initial stenting procedure (2.31 +/- 0.38 vs. 2.44 +/- 0.35 mm). Of five patients with angiographic follow-up, three had restenosis requiring reintervention (surgery in two and repeat atherectomy followed by laser angioplasty in one). Intimal hyperplasia was identified in 80% of specimens after stenting and in 77% after coronary angioplasty or atherectomy. In three patients with stenting, 70% to 76% of the intimal cells showed morphologic features of a contractile phenotype by electron microscopy 47 to 185 days after coronary intervention. Evidence of ongoing proliferation (proliferating cell nuclear antigen antibody studies) was absent in all specimens studied. Although wide individual variability was present in the maximal cell density of the intimal hyperplasia, there was a trend toward a reduction in cell density over time. CONCLUSIONS: Although atherectomy is feasible for the treatment of restenosis in stented coronary arteries and initial results are excellent, recurrence of restenosis is common. Intimal hyperplasia is a nonspecific response to injury regardless of the device used and accounts for about 80% of cases of restenosis. Smooth muscle cell proliferation and phenotypic modulation toward a contractile phenotype are early events and largely completed by the time of clinical presentation of restenosis. Restenotic lesions may be predominantly cellular, matrix or a combination at a particular time after a coronary procedure.

Actins↗

Comparative quantitative angiographic analysis of directional coronary atherectomy and balloon coronary angioplasty.

An attempt to assess the "utility" of directional atherectomy was made using a new quantitative angiographic index. This index can be subdivided into an initial gain component and a restenosis component. The initial gain index is the ratio between the gain in diameter during intervention and the theoretically achievable gain (i.e., reference diameter). The restenosis index is the ratio between the decrease at follow-up and the initial gain during the procedure. The net result at long-term follow-up is characterized by the utility index, which is the ratio between the final gain in diameter at follow-up and what theoretically could have been achieved. For this purpose, 30 coronary artery lesions were selected from a consecutive series of successfully dilated primary angioplasty lesions and were matched with the initial 30 successfully treated primary atherectomy lesions. Matching by location of stenosis and reference diameter resulted in 2 comparable groups with identical preprocedural stenosis characteristics. Atherectomy resulted in an increase in minimal luminal diameter 2 times larger than angioplasty (1.53 vs 0.77 mm; p less than 0.0001). However, at follow-up there was a significant decrease in minimal luminal diameter and a significant increase in percent diameter stenosis in the groups with atherectomy and angioplasty (1.69 +/- 0.58 vs 1.57 +/- 0.58 mm, p = not significant [NS], and 37 +/- 18 vs 47 +/- 18%, p = NS, respectively). The decrease in minimal luminal gain was more pronounced in the group with atherectomy than in that with angioplasty (0.92 +/- 0.69 vs 0.35 +/- 0.51 mm; p = 0.0005).(ABSTRACT TRUNCATED AT 250 WORDS)

Angioplasty, Balloon, Coronary↗

Comparative angiographic quantitative analysis of the immediate efficacy of coronary atherectomy with balloon angioplasty, stenting, and rotational ablation.

Interventional cardiology has branched in two directions: devices that primarily dilate coronary stenoses and those that debulk coronary tissue. Presently the optimum coronary intervention has not been found. While patients are awaiting randomized trials, a comparison based on matched quantitative coronary analysis may be useful to evaluate results of new interventional techniques. Therefore we compared 51 patients undergoing atherectomy with individually matched patients who were undergoing balloon angioplasty and stenting. The lesions were matched according to location of stenosis and reference diameter. Atherectomy and stenting resulted in larger gains in minimal luminal diameter compared with conventional balloon angioplasty. The minimal luminal diameter was increased from 1.2 +/- 0.4 mm to 2.6 +/- 0.4 mm in the atherectomy group and from 1.2 +/- 0.3 mm to 1.9 +/- 0.4 mm in the angioplasty group (p less than 0.00001). Atherectomy and stenting resulted in similar gains in minimum luminal diameter (1.4 mm vs 1.3 mm, p = NS). In addition, atherectomy and stenting appear to be more effective in resisting elastic recoil because of tissue removal and an intrinsic dilating effect, respectively. In matched populations directional atherectomy and stenting appear to be more effective intracoronary interventional devices than balloon angioplasty based on the immediate results. However, atherectomy is limited in smaller coronary vessels because of its larger size.

Angioplasty, Laser↗

Quantitative angiography after directional coronary atherectomy.

OBJECTIVE: To assess by quantitative analysis the immediate angiographic results of directional coronary atherectomy. To compare the effects of successful atherectomy with those of successful balloon dilatation in a series of patients with matched lesions. DESIGN: Case series. SETTING: Tertiary referral centre. PATIENTS: 62 patients in whom directional coronary atherectomy was attempted between 7 September 1989 and 31 December 1990. INTERVENTIONS: Directional coronary atherectomy. MAIN OUTCOME MEASURES: Increase in minimal luminal diameter of coronary artery segment. RESULTS: Angiographic success on the basis of intention to treat was obtained in 54 patients (87%). In four patients the lesion could not be crossed by the atherectomy device; all four had an uneventful conventional balloon angioplasty. Four of the 58 patients who underwent atherectomy were subsequently referred for coronary bypass surgery because of failure or complications; three of them sustained a transmural infarction. In the successful cases, coronary atherectomy resulted in an increase in the minimal luminal diameter from 1.1 mm to 2.5 mm with a concomitant decrease of the diameter stenosis from 62% to 22%. In the subset of 37 patients in which the changes induced were compared with conventional balloon angioplasty atherectomy increased the minimal luminal diameter more than balloon angioplasty (1.6 v 0.8 mm; p less than 0.0001). Conventional histology showed media or adventitia in 26% of the atherectomy specimens. In hospital complications occurred in six patients who had undergone a successful procedure: two transmural infarctions, two subendocardial infarctions, one transient ischaemia attack, and one death due to delayed rupture of the atherectomised vessel. All patients were clinically evaluated at one and six months. One patient had persisting angina (New York Heart Association class II), one patient sustained a myocardial infarction, one patient underwent a percutaneous transluminal coronary angioplasty for early restenosis, and one patient underwent coronary bypass surgery because of a coronary aneurysm formation. At six months 80% (36/47) of the patients were symptom free. CONCLUSIONS: Coronary atherectomy achieved a better immediate angiographic result than balloon angioplasty; however, in view of the complication rate in this preliminary series, which may be related to a learning curve, a randomised study is needed to show whether this procedure is as safe as a conventional balloon angioplasty.

Angioplasty, Balloon, Coronary↗

Desensitization of aortic smooth muscle contraction in rats harboring pheochromocytoma.

Desensitization of smooth muscle contraction was studied in aortic ring segments obtained from New England Deaconness Hospital rats harboring pheochromocytomas, a norepinephrine-secreting tumor. Rats were studied 5 to 6 weeks after implantation of the pheochromocytoma, by which time severe hypertension had developed. Aortic ring segments from the pheochromocytoma rats were significantly less sensitive to the alpha-1 adrenergic agonist phenylephrine [log10 (ED50) = -7.21 +/- 0.09 vs. -7.63 +/- 0.11 in controls). In addition, the maximal force of contraction induced by phenylephrine was decreased in the aortas from pheochromocytoma rats (1.31 +/- 0.15 g) compared to controls (2.17 +/- 0.23 g). The potency of the thromboxane A2 receptor agonist U-46,619 was decreased in the aortic ring segments from pheochromocytoma rats compared to controls, although it elicited a similar maximal force of contraction. Desensitization of alpha receptor-mediated contraction was prevented by treating the pheochromocytoma-bearing rats with the reversible alpha adrenergic antagonist phentolamine (200 micrograms/kg/hr) via osmotic minipumps for 2 weeks. However, phentolamine did not decrease the hypertension in these rats. Also, large doses of the irreversible alpha adrenergic antagonist phenoxybenzamine (4 mg/kg/day i.p.) did not decrease blood pressure in rats harboring pheochromocytoma or did the drug completely block aortic alpha receptors in these rats as it did in controls. The results indicate that pheochromocytoma induces heterologous desensitization of smooth muscle contraction in rat aorta. The desensitization is due to direct effects of catecholamines unrelated to hypertension. The New England Deaconess Hospital rat harboring pheochromocytoma is an interesting model to study the effects of high concentrations of plasma catecholamines on smooth muscle contraction.

15-Hydroxy-11 alpha,9 alpha-(epoxymethano)prosta-5↗