Comparison of IMRT optimization based on a pencil beam and a superposition algorithm.

To investigate the role of sophisticated dose calculation methods for treatment planning, we compared conventional pencil beam optimized 6 and 15 MV intensity-modulated treatment plans with optimizations based on the superposition technique. Five lung and five head and neck IMRT cases with spatial resolutions of bixels and dose voxels usually employed in clinical practice were considered for tumor volumes between 15 and 500 cm3. We investigated the systematic error of the pencil beam algorithm and the pencil beam induced error to the optimal solution of bixel weights. For the lung cases, the pencil beam overestimated the mean dose deposited inside the planning target volume (PTV) by about 8%, for small lung tumors even up to 20.6%. In the head and neck cases only a slight overestimation in mean PTV dose of 1.5% was observed. The optimization with the superposition method substantially improved the dose coverage of the considered radiation targets. Additionally, for the head and neck cases, the brainstem was significantly spared by about 4% mean PTV dose through the use of the superposition technique. Our studies showed that, in target regions with intricate tissue inhomogeneities, superposition or Monte Carlo techniques have to be used for the optimization and the final dose calculation of intensity-modulated treatment plans.

Algorithms↗

IMRT-application with an add-on MMLC.

In order to provide automatic IMRT dose delivery with an add-on MMLC a technical integration of a MMLC system with a linear accelerator was realized. The principle of this integration and the changes and enhancements of the existing hard- and software are briefly described. The system was tested by the automatic delivery of an IMRT plan designed for a head and neck phantom. A verification of dose delivery was performed with film dosimetry. The plan consisting of 78 "step and shoot" segments could be delivered within 17 minutes. A high spatial accuracy of the fluence pattern at the isocentre was reached by a resolution of 2.75x2.75 mm(2). The measured dose profiles were within 3% of the maximum dose of the calculated profiles.

Humans↗

Two-dimensional pencil beam scaling: an improved proton dose algorithm for heterogeneous media.

New dose delivery techniques with proton beams, such as beam spot scanning or raster scanning, require fast and accurate dose algorithms which can be applied for treatment plan optimization in clinically acceptable timescales. The clinically required accuracy is particularly difficult to achieve for the irradiation of complex, heterogeneous regions of the patient's anatomy. Currently applied fast pencil beam dose calculations based on the standard inhomogeneity correction of pathlength scaling often cannot provide the accuracy required for clinically acceptable dose distributions. This could be achieved with sophisticated Monte Carlo simulations which are still unacceptably time consuming for use as dose engines in optimization calculations. We therefore present a new algorithm for proton dose calculations which aims to resolve the inherent problem between calculation speed and required clinical accuracy. First, a detailed derivation of the new concept, which is based on an additional scaling of the lateral proton fluence is provided. Then, the newly devised two-dimensional (2D) scaling method is tested for various geometries of different phantom materials. These include standard biological tissues such as bone, muscle and fat as well as air. A detailed comparison of the new 2D pencil beam scaling with the current standard pencil beam approach and Monte Carlo simulations, performed with GEANT, is presented. It was found that the new concept proposed allows calculation of absorbed dose with an accuracy almost equal to that achievable with Monte Carlo simulations while requiring only modestly increased calculation times in comparison to the standard pencil beam approach. It is believed that this new proton dose algorithm has the potential to significantly improve the treatment planning outcome for many clinical cases encountered in highly conformal proton therapy.

Algorithms↗

Acceleration of intensity-modulated radiotherapy dose calculation by importance sampling of the calculation matrices.

In inverse planning for intensity-modulated radiotherapy, the dose calculation is a crucial element limiting both the maximum achievable plan quality and the speed of the optimization process. One way to integrate accurate dose calculation algorithms into inverse planning is to precalculate the dose contribution of each beam element to each voxel for unit fluence. These precalculated values are stored in a big dose calculation matrix. Then the dose calculation during the iterative optimization process consists merely of matrix look-up and multiplication with the actual fluence values. However, because the dose calculation matrix can become very large, this ansatz requires a lot of computer memory and is still very time consuming, making it not practical for clinical routine without further modifications. In this work we present a new method to significantly reduce the number of entries in the dose calculation matrix. The method utilizes the fact that a photon pencil beam has a rapid radial dose falloff, and has very small dose values for the most part. In this low-dose part of the pencil beam, the dose contribution to a voxel is only integrated into the dose calculation matrix with a certain probability. Normalization with the reciprocal of this probability preserves the total energy, even though many matrix elements are omitted. Three probability distributions were tested to find the most accurate one for a given memory size. The sampling method is compared with the use of a fully filled matrix and with the well-known method of just cutting off the pencil beam at a certain lateral distance. A clinical example of a head and neck case is presented. It turns out that a sampled dose calculation matrix with only 1/3 of the entries of the fully filled matrix does not sacrifice the quality of the resulting plans, whereby the cutoff method results in a suboptimal treatment plan.

Algorithms↗