Search PubMed⌕ Search

Biomedical subjects

Ulrich Kertzscher

Publications and source records attributed to Ulrich Kertzscher.

4 recordsLinked to original sources

In-vivo coronary flow profiling based on biplane angiograms: influence of geometric simplifications on the three-dimensional reconstruction and wall shear stress calculation.

BACKGROUND: Clinical studies suggest that local wall shear stress (WSS) patterns modulate the site and the progression of atherosclerotic lesions. Computational fluid dynamics (CFD) methods based on in-vivo three-dimensional vessel reconstructions have recently been shown to provide prognostically relevant WSS data. This approach is, however, complex and time-consuming. Methodological simplifications are desirable in porting this approach from bench to bedside. The impact of such simplifications on the accuracy of geometry and wall shear stress calculations has to be investigated. METHODS: We investigated the influence of two methods of lumen reconstruction, assuming circular versus elliptical cross-sections and using different resolutions for the cross-section reconstructions along the vessel axis. Three right coronary arteries were used, of which one represented a normal coronary artery, one with "obstructive", and one with "dilated" coronary atherosclerosis. The vessel volume reconstruction was performed with three-dimensional (3D) data from a previously validated 3D angiographic reconstruction of vessel cross-sections and vessel axis. RESULTS: The difference between the two vessel volumes calculated using the two evaluated methods is less than 1 %. The difference, of the calculated pressure loss, was between 2.5% and 8.5% for the evaluated methods. The distributions of the WSS histograms were nearly identical and strongly cross-correlated (0.91-0.95). The good agreement of the results was confirmed by a Chi-square test. CONCLUSION: A simplified approach to the reconstruction of coronary vessel lumina, using circular cross-sections and a reduced axial resolution of about 0.8 mm along the vessel axis, yields sufficiently accurate calculations of WSS.

Blood Flow Velocity↗

Innovative developments of the heart valves designed for use in ventricular assist devices.

Prosthetic heart valves are routinely used for replacing diseased natural heart valves. Even today, after five decades of prosthetic heart valve development, in the authors opinion the main problem associated with these valves is the risk of thromboembolic complications caused by unnatural hemodynamics. Further growing application of prosthetic heart valves is their use in the pulsatile ventricular assist devices (VADs). VADs may provide life-saving solutions to patients with severe cardiovascular diseases and are superior to drug therapy for patients with severe heart failure. However, the clinical applications of VADs still suffer from thromboembolic complications due to thrombus formations in the vicinity of the valves. Wherever the flow is stagnant or flow separation occurs, a thrombus is likely to form. The design of the heart valves with flow avoiding the formation of stagnant zones is one of the main goals in the development of new valves. This article reviews some innovative design approaches of the valves specially designed for use in VADs. Three design concepts are presented; one is based on the tilting disk valve, the second on the natural valve geometry and the third on the ball valve principle. However, these three different concepts have one common basic idea; the use of the freedom of the valve-housing design. This additional design freedom, which is available in VADs, is a key factor in the development of new valves with optimal hemodynamic performance.

Computer Simulation↗

Investigation of transport phenomena inside a microcapsule.

Mass transfer within a microcapsule is enhanced by convection, achieved by introducing a movable body inside the microcapsule. This body has a different density from the fluid within the microcapsule and can be moved relative to the microcapsule by application of an external force, such as a magnetic field or acceleration/deceleration. The effect of the transport improvement was investigated as a function of the Peclet number (Pe) by using computational fluid dynamics and particle image velocimetry. The results show that the period to achieve 80% saturation in the microcapsule was reduced by 60% with a movable body with half of the diameter of the microcapsule and Pe = 600, compared to the mass transport in the microcapsule with a non-movable body.

Capsules↗

X-ray-based flow visualization and measurement: application in multiphase flows.

Information concerning continuous or discreet phase flow in multiphase systems is desired for various practical and analytical applications. The potential of X-ray-based flow visualization and measurement of multiphase flow is demonstrated here by two non-intrusive methods: (1) Measurement of the three-dimensional (3D) velocity field of the continuous liquid phase in a bubble column by X-ray-based particle tracking velocimetry (PTV) of seeded particles. (2) Liquid flow visualization in a bubble column by injecting an X-ray absorbing liquid into the bubble column. X-rays have the advantage that they are not affected by the various refraction indices of the multiphase system and penetrate the multiphase flow in undistorted straight lines. Hence, in contrast to optical methods, both of these X-ray-based methods are independent of the void fraction and are applicable to opaque liquids.

Biotechnology↗