Search PubMed⌕ Search

Biomedical subjects

Ulf Ekelund

Publications and source records attributed to Ulf Ekelund.

47 records · Page 3Linked to original sources

International physical activity questionnaire: 12-country reliability and validity.

BACKGROUND: Physical inactivity is a global concern, but diverse physical activity measures in use prevent international comparisons. The International Physical Activity Questionnaire (IPAQ) was developed as an instrument for cross-national monitoring of physical activity and inactivity. METHODS: Between 1997 and 1998, an International Consensus Group developed four long and four short forms of the IPAQ instruments (administered by telephone interview or self-administration, with two alternate reference periods, either the "last 7 d" or a "usual week" of recalled physical activity). During 2000, 14 centers from 12 countries collected reliability and/or validity data on at least two of the eight IPAQ instruments. Test-retest repeatability was assessed within the same week. Concurrent (inter-method) validity was assessed at the same administration, and criterion IPAQ validity was assessed against the CSA (now MTI) accelerometer. Spearman's correlation coefficients are reported, based on the total reported physical activity. RESULTS: Overall, the IPAQ questionnaires produced repeatable data (Spearman's rho clustered around 0.8), with comparable data from short and long forms. Criterion validity had a median rho of about 0.30, which was comparable to most other self-report validation studies. The "usual week" and "last 7 d" reference periods performed similarly, and the reliability of telephone administration was similar to the self-administered mode. CONCLUSIONS: The IPAQ instruments have acceptable measurement properties, at least as good as other established self-reports. Considering the diverse samples in this study, IPAQ has reasonable measurement properties for monitoring population levels of physical activity among 18- to 65-yr-old adults in diverse settings. The short IPAQ form "last 7 d recall" is recommended for national monitoring and the long form for research requiring more detailed assessment.

Adolescent↗

PGC-1alpha genotype modifies the association of volitional energy expenditure with [OV0312]O2max.

UNLABELLED: Sedentary lifestyles are increasingly common and result in low cardiorespiratory fitness ([OV0312]O2max), a well-established predictor of early mortality and coronary heart disease (CHD). Adaptation in [OV0312]O2max after exercise training varies considerably between people. Because there are hereditary components to fitness, it is likely that genetic factors explain some of this variability. PPARGC1 (PGC-1alpha) coactivates genes involved in energy transduction and mitochondrial biogenesis. Transgenic mouse data demonstrate that overexpression of PGC-1alpha mRNA increases endurance capacity by transformation of nonoxidative to oxidative skeletal muscle tissue. Other murine studies demonstrate that exercise increases PGC-1alpha mRNA expression. PURPOSE: To explore whether a candidate polymorphism in the PGC-1alpha gene modifies the association between physical activity energy expenditure (PAEE) and predicted [OV0312]O2max ([OV0312]O2max.pred). METHOD: We examined whether the Gly482Ser polymorphism of PGC-1alpha modified the relationship between objectively measured PAEE and [OV0312]O2max.pred in a population-based sample of 599 healthy middle-aged people. PAEE was assessed using individual calibration with 4 d of heart rate monitoring. [OV0312]O2max.pred was measured during a submaximal exercise stress test on a bicycle ergometer. RESULTS: Homozygosity at the Ser482 allele was found in 12.7% of the cohort, whereas 38.9% and 48.4% carried the Gly482Gly and Gly482Ser genotypes, respectively. The association between PAEE and [OV0312]O2max.pred (mL x kg(-1) x min(-1)) was strongest in people homozygous for the Ser482 allele (beta = 12.03; P < 0.00001) compared with carriers of the Gly allele (beta = 5.61; P < 0.00001). In a recessive model for the Ser482 allele, the interaction between PAEE and genotype on [OV0312]O2max.pred (L x min(-1)) was highly significant (P = 0.009). CONCLUSION: Our results indicate that Ser482 homozygotes may be most capable of improving cardiorespiratory fitness when physically active, and that Gly482Ser may explain some of the between-person variance previously reported in cardiorespiratory adaptation after exercise training.

Adult↗

Patients with suspected acute coronary syndrome in a university hospital emergency department: an observational study.

BACKGROUND: Improved diagnostics in suspected acute coronary syndrome (ACS) are considered to be needed. To help clarify the current situation and the improvement potential, judged risk in the emergency department (ED) and outcome were analyzed among patients with suspected ACS at a university hospital. METHODS: 157 consecutive patients with symptoms of ACS were included at the ED during 10 days. Risk of ACS was estimated in the ED for each patient based on history, physical examination and ECG by assigning them to one of four risk categories; I (obvious myocardial infarction, MI), II (strong suspicion of ACS), III (vague suspicion of ACS), and IV (no suspicion of ACS). RESULTS: 4, 17, 29 and 50% of the patients were allocated to risk categories I-IV respectively. 74 patients (47%) were hospitalized but only 19 (26%) had ACS as the discharge diagnose. In risk categories I-IV, ACS rates were 100, 37, 12 and 0%, respectively. Of those admitted without ACS, at least 37% could probably, given perfect ED diagnostics, have been immediately discharged. 83 patients were discharged from the ED, and among them there were no hospitalizations for ACS or cardiac mortality at 6 months. Only about three patients per 24 h were considered eligible for a potential ED chest pain unit. CONCLUSIONS: Almost 75% of the patients hospitalized with suspected ACS did not have it, and some 40% of these patients could probably, given perfect immediate diagnostics, have been managed as outpatients. The potential for diagnostic improvement in the ED seems large.

Journal Article↗

The validity of the Computer Science and Applications activity monitor for use in coronary artery disease patients during level walking.

The principal aim of the present study was to examine the validity of the Computer Science and Applications (CSA) activity monitor during level walking in coronary artery disease (CAD) patients. As a secondary aim, we evaluated the usefulness of two previously published energy expenditure (EE) prediction equations. Thirty-four subjects (29 men and five women), all with diagnosed CAD, volunteered to participate. Oxygen uptake (VO2) was measured by indirect calorimetry during walking on a motorized treadmill at three different speeds (3.2, 4.8 and 6.4 km h-1). Physical activity was measured simultaneously using the CSA activity monitor, secured directly to the skin on the lower back (i.e. lumbar vertebrae 4-5) with an elastic belt. The mean (+/- SD) activity counts were 1208 +/- 429, 3258 +/- 753 and 5351 +/- 876 counts min-1, at the three speeds, respectively (P < 0.001). Activity counts were significantly correlated to speed (r = 0.92; P < 0.001), VO2 (ml kg-1 min-1; r = 0.87; P < 0.001) and EE (kcal min-1; r = 0.85, P < 0.001). A stepwise linear regression analysis showed that activity counts and body weight together explained 75% of the variation in EE. Predicted EE from previously published equations differed significantly when used in this group of CAD patients. In conclusion, the CSA activity monitor is a valid instrument for assessing the intensity of physical activity during treadmill walking in CAD patients. Energy expenditure can be predicted from body weight and activity counts.

Acceleration↗

Physical activity but not energy expenditure is reduced in obese adolescents: a case-control study.

BACKGROUND: The influence of physical activity on body weight in children and adolescents is controversial. OBJECTIVE: The objective was to test the hypothesis that the intensity and duration of physical activity differ between obese and normal-weight adolescents, with no difference in estimated energy expenditure. DESIGN: We compared physical activity in 18 (8 males, 10 females) obese [body mass index (in kg/m(2)) > 30] adolescents (14-19 y) with that in a matched, normal-weight (BMI < 27) control group. Total energy expenditure (TEE) was measured with the doubly labeled water method, and physical activity was measured simultaneously by accelerometry. The physical activity level was determined as the ratio of TEE to the resting metabolic rate (RMR) and activity energy expenditure as 0.9 TEE minus RMR. Accelerometry data included total physical activity (counts x min(-1) x d(-1)), accumulated and continuous duration of activity, and continuous 10-min periods of physical activity of moderate intensity. RESULTS: There was no significant difference in adjusted (analysis of covariance) TEE, RMR, or AEE between groups. The physical activity level was significantly lower (P < 0.05) in the obese group. No sex x group interaction was observed. Differences in total physical activity (P < 0.001), accumulated time (P < 0.05), continuous time (P < 0.01), and continuous 10-min periods of physical activity of moderate intensity (P < 0.01) were observed between groups. CONCLUSIONS: Obese adolescents are less physically active than are normal-weight adolescents, but physical activity-related energy expenditure is not significantly different between groups. The data suggest that physical activity is not necessarily equivalent to the energy costs of activity.

Adolescent↗

Energy expenditure assessed by heart rate and doubly labeled water in young athletes.

PURPOSE: To compare total energy expenditure (TEE) estimated by the FLEX heart rate (HR) method with that measured by the doubly labeled water (DLW) technique in young speed skaters. We hypothesized that the accuracy of FLEX HR-estimated TEE would be affected by a) the definition of the FLEX HR and b) the type of training regimen. METHODS: Eight young athletes (mean age 18.2 +/- 1.3 yr) underwent measurements during two 10-d training periods: an off-season period with voluntary training (predominantly running) and a preseason period mainly focused on skating technique training. TEE was measured simultaneously by the DLW and FLEX HR methods. FLEX HR1 was defined as the mean of the HRs during all resting calibration activities and the lowest HR during exercising calibration activities. FLEX HR2 was defined as the mean of the highest HR during resting activities and the lowest HR during exercising. RESULTS: ANOVA showed that FLEX HR1 was significantly lower than FLEX HR2 (mean of both periods; 77 +/- 5 vs 84 +/- 6 beats.min(-1); P = 0.004). TEE values obtained by DLW were 16.8 +/- 3.8 and 16.9 +/- 2.9 MJ.d(-1) in the two periods, respectively. TEE values calculated from FLEX HR1 were 17.8 +/- 3.6 and 17.4 +/- 2.6 MJ.d(-1), and those from FLEX HR2 17.1 +/- 3.1 and 17.0 +/- 2.7 MJ.d-1, respectively. No significant period (P = 0.83) or method (P = 0.44) effect on TEE was observed. CONCLUSION: FLEX HR-estimated TEE was not affected by the definition of the FLEX HR or by the type of training regimen as compared with TEE measured by the DLW method in young athletes.

Adolescent↗

Effects of a problem-based learning rehabilitation program on physical activity in patients with coronary artery disease.

PURPOSE: To evaluate the effects of a problem-based learning (PBL) rehabilitation program on physical activity. METHODS: We randomized 207 consecutive patients younger than 70 years, with a recent event of coronary artery disease (CAD), to a PBL group (n = 104) or a control group (n = 103). In addition to standard treatment, the PBL patients participated in a 1-year program with 13 sessions in small groups, where learning needs and behavior change were focused upon. Physical activity was assessed by means of interviews with all patients and by an activity monitor in 69 patients at pretest and in 175 after 1 year. RESULTS: Only small differences between groups were found at posttest. Interview data revealed significantly less activity at low-intensity level in the control group, whereas the activity monitor showed no significant differences. No changes were found in total physical activity during the year within the 2 groups. The self-reported physical activity indicating a level of brisk walking was markedly higher than that measured by the activity monitor, the latter indicating that only 35% of the patients achieved a 10-minute period of continued physical activity per day on an adequate level. CONCLUSIONS: Our PBL program had no important impact on the physical activity pattern of patients with CAD. The activity monitor is a feasible way of measuring physical activity in these patients, indicating a lower level of physical activity than interview data.

Aged↗

[More efficient investigation in suspected acute coronary syndrome possible. New diagnostic methods can improve the quality of care and save resources].

The immediate evaluation of patients with suspected acute coronary syndrome (ACS) in the emergency department (ED) has remained almost unchanged for decades. At the same time, therapy for established ACS has undergone a remarkable and successful change towards early active intervention. Studies show that 7 out of 10 patients admitted with a suspicion of ACS do not have it, and that 2-5% of the patients with ACS are incorrectly sent home from the ED. With new diagnostic strategies, including e.g. risk prediction algorithms, new blood samples for plaque instability, special investigations like echocardiography, myocardial perfusion imaging and magnetic resonance imaging, as well as the Chest Pain Unit concept, improvements should definitely be possible. With the structured and evidence-based use of such strategies, it is our belief that more patients can be managed as outpatients, that length of stay can be shortened for those admitted, and that some patients with ACS can get an earlier adequate intervention.

Acute Disease↗