Search PubMed⌕ Search

Biomedical subjects

Udo Hoffmann

Publications and source records attributed to Udo Hoffmann.

56 records · Page 4Linked to original sources

Comparative study with a moving heart phantom of the impact of temporal resolution on image quality with two multidetector electrocardiography-gated computed tomography units.

OBJECTIVE: The objective of this study was to compare the temporal resolution-related image quality of electrocardiography-gated images acquired with two multidetector computed tomography (CT) units with a moving heart phantom, at similar fixed heart rates, using half-scan and multisector acquisition modes. METHODS: An adjustable moving heart phantom (Limbsandthings, Horfield, Bristol, UK) was used. Specific heart rates (47, 55, 64, 66, 69, and 73 beats per minute [bpm]) were chosen. On a General Electric CT unit (LightSpeed Plus; General Electric Medical Systems, Milwaukee, WI), retrospective half-scan and multisector mode protocols were performed. On a Siemens CT unit (Somatom Volume Zoom; Siemens, Forchheim, Germany), a retrospective half-scan mode was performed at 47, 55, and 64 bpm, and a two-sector mode was performed at 66, 69, and 73 bpm. Reformatted maximum intensity projection images were qualitatively compared and related to their temporal resolution. RESULTS: Half-scan mode protocols provided similar good results with both CT units up to 55 bpm. The two-sector mode improved image quality compared with the half-scan mode. High temporal resolution with the multisector mode provided the best results. CONCLUSION: For coronary artery imaging, acquisition protocols that provide the highest temporal resolution are mandatory. The multisector mode is one technique that allows high temporal resolution but may be clinically inappropriate at heart rates below 65 bpm or when heart rate variation is observed during scan time.

Coronary Angiography↗

Cardiac CT in emergency department patients with acute chest pain.

Current strategies for the triage of patients who have chest pain but normal initial cardiac enzyme levels and nondiagnostic electrocardiograms do not permit efficient risk stratification. The potentially fatal consequences and high malpractice costs of missed acute coronary syndromes lead every year to the unnecessary hospital admission of about 2.8 million patients who present with acute chest pain in emergency departments in the United States. Most of these patients are at very low risk for an acute coronary syndrome. However, the standard clinical work-up does not provide information about the presence and extent of coronary artery disease. In most patients (80%-94%) with an acute coronary syndrome, a significant coronary artery stenosis can be detected with selective coronary angiography. High levels of diagnostic accuracy also have been established for the detection of significant coronary artery stenosis with the use of 16- and 64-section multidetector computed tomography (CT) in patients with stable angina. Preliminary data indicate that multidetector CT also can help quantify and characterize coronary atherosclerotic plaque and that the CT findings are in good agreement with those at intravascular ultrasonography. Although multidetector CT provides accurate information about the presence of coronary artery disease, large blinded observational studies are warranted to identify CT characteristics with high accuracy for diagnosis of acute coronary syndromes. Such information would enable the conduct of randomized controlled trials to determine whether the detection of coronary stenosis and plaque with multidetector CT improves triage and reduces the costs or increases the cost-effectiveness of management of acute chest pain.

Acute Disease↗