Search PubMed⌕ Search

Biomedical subjects

U Zimmermann

Publications and source records attributed to U Zimmermann.

At least 289 records · Page 16Linked to original sources

Dielectric breakdown in the membranes of Valonia utricularis. The role of energy dissipation.

The electrical properties of the membranes of Valonia utricularis were investigated using intracellular electrodes. Using short (0.5-1.0 ms) current pulses it was found that at a critical membrane potential difference of 0.85 V there was a large and discontinuous decrease in the membrane impedance and the slope resistance beyond this potential was virtually zero. The electrical breakdown of the membranes did not lead to global damage of the cells and after a resealing time of approx. 5 s could be repeated with identical results. Experiments with long current pulses and long bursts of pulses repeated at 1 kHz are described which show that the electrical breakdown is not due to thermal damage arising from localized heating in the membrane. Thus a dissipation of some 10-3-10-5 times the energy normally dissipated during the onset of breakdown did not lead to breakdown itself unless the critical membrane potential was exceeded. The results also show that punch-through and avalanche ionization are not likely to be important in the breakdown mechanism. The results are consistent, however, with there being a critical instability in the electro-mechanical stresses set up in the membrane at large electric field strengths.

Cell Membrane↗

Preparation of erythrocyte ghosts by dielectric breakdown of the cell membrane.

Dielectric breakdown of membranes of red blood cells was observed in high electric fields (approx. 10-3-10-4 V/cm) using an improved Coulter Counter with hydrodynamic focussing. In making measurements of the size distributions of red blood cells as a function of increasing electric field strength it was found that a sharp discontinuity occurred in the otherwise linear relation between the pulse heights in the Coulter Counter and the electric field strength due to dielectric breakdown of the membranes. Solution of Laplace's equation for the electric field generated at breakdown in the cell membranes yeilds a mean value of about 1.6 V. for the membrane potential of red blood cells. Due to the dielectric break-down, release of hemoglobin occurred. Mechanical rupture of the red blood cells by the hydrodynamic forces in the orifice of the Coulter Counter or thermal rupture could be excluded as hemolysing mechanisms. The leaky ghost cells resealed at 37 degrees C. as shown by incorporation of 131I-labeled albumin and repeated dielctric breakdown.

Animals↗

Dielectric breakdown of cell membranes.

With human and bovine red blood cells and Escherichia coli B, dielectric breakdown of cell membranes could be demonstrated using a Coulter Counter (AEG-Telefunken, Ulm, West Germany) with a hydrodynamic focusing orifice. In making measurements of the size distributions of red blood cells and bacteria versus increasing electric field strength and plotting the pulse heights versus the electric field strength, a sharp bend in the otherwise linear curve is observed due to the dielectric breakdown of the membranes. Solution of Laplace's equation for the electric field generated yields a value of about 1.6 V for the membrane potential at which dielectric breakdown occurs with modal volumes of red blood cells and bacteria. The same value is also calculated for red blood cells by applying the capacitor spring model of Crowley (1973. Biophys. J. 13:711). The corresponding electric field strength generated in the membrane at breakdown is of the order of 4 . 10(6) V/cm and, therefore, comparable with the breakdown voltages for bilayers of most oils. The critical detector voltage for breakdown depends on the volume of the cells. The volume-dependence predicted by Laplace theory with the assumption that the potential generated across the membrane is independent of volume, could be verified experimentally. Due to dielectric breakdown the red blood cells lose hemoglobin completely. This phenomenon was used to study dielectric breakdown of red blood cells in a homogeneous electric field between two flat platinum electrodes. The electric field was applied by discharging a high voltage storage capacitor via a spark gap. The calculated value of the membrane potential generated to produce dielectric breakdown in the homogeneous field is of the same order as found by means of the Coulter Counter. This indicates that mechanical rupture of the red blood cells by the hydrodynamic forces in the orifice of the Coulter Counter could also be excluded as a hemolysing mechanism. The detector voltage (or the electric field strength in the orifice) depends on the membrane composition (or the intrinsic membrane potential) as revealed by measuring the critical voltage in E. coli B harvested from the logarithmic and stationary growth phases. The critical detector voltage increased by about 30% for a given volume on reaching the stationary growth phase.

Animals↗

Transcellular ion flow in Escherichia coli B and electrical sizing of bacterias.

Dielectric breakdown of cell membranes and, in response, transcellular ion flows were measured in Escherichia coli B 163 and B 525 using a Coulter counter as the detector with a hydrodynamic jet focusing close to the orifice of the counter. Plotting the relative pulse height for compensated amplification of a certain size of the cells against increasing detector current, a rather sharp bend within the linear function was found, which did not occur when measuring fixed cells or polystyrene latex. The start current for transcellular ion flow causing the change of the slope is different for the potassium-deficient mutant B 525 in comparison with the wild-type B 163, indicating a change in the membrane structure of B 525 by mutation and demonstrating the sensitivity of the method for studying slight changes in membrane structure in general. The theoretical size distributions for two current values in the range of transcellular ion flow were constructed from the true size distribution at low detector currents, assuming an idealized sharp changeover of the bacterial conductivity from zero to one-third of the electrolyte conductivity.

Cell Biology↗