Mathematical tools for spatial computations with biplane isocentric X-ray equipment.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to U Solzbach.
Explore the source record for details and available documents.
UNLABELLED: Modern biplane multidirectional isocentric X-ray equipment delivers the image information necessary for spatial computations from two simultaneous 2-dimensional coronary angiographic pictures. Using the tools of analytical geometry, the spatial position of well definable points in the fields of view of the two image-intensifiers can be calculated from their corresponding projections knowing the geometrical properties of the system stands. The method developed is independent of the angle between the projections and is applicable even if hemiaxial views are used. The mathematical formulas necessary for these spatial computations are derived. By means of calculating the radiological magnification factor, the method was validated using a wire with known diameter as reference object. 360-diameter measurements of the wire filmed in 18 different simultaneous biplane projections resulted in a mean error of 3.14%. In addition, catheter measurements of routine coronary angiograms yielded a mean diameter of 2.64 +/- 0.19 mm (mean +/- SD, real diameter 2.66 mm). CONCLUSION: Using this algorithm, a reliable determination of spatial coordinates of distinct points of interest is possible as prerequisite for absolute quantitative measurements from biplane angiograms.
In 11 open-chest dogs with a flowmeter on the left circumflex artery, L-NMMA, a selective inhibitor of nitric oxide-formation, was subselectively infused into the left circumflex artery at a rate of 2.5 mg/ml (ml/min) to avoid systemic hemodynamic effects. The coronary blood flow at normal arterial blood pressure was similar prior to and during L-NMMA infusion. However, when the arterial blood pressure was raised by inflating a balloon in the descending aorta, the nitric oxide suppression induced a dramatic increase in coronary vascular resistance by almost 40% compared to control conditions without L-NMMA infusion at identically elevated arterial blood pressure. L-NMMA induced a significant downward shift and flattening of the pressure-flow relation over a pressure range from 60-150 mmHg. Peak hyperemic coronary flow after 20-s transient coronary occlusion was similar prior to and during L-NMMA infusion, but the duration of the hyperemic flow response was significantly shortened during L-NMMA infusion indicating exaggerated constriction after hyperemic stimulus. The EDRF/nitric oxide-system plays an important role for the regulation of coronary blood flow by counteracting autoregulatory constrictor responses to increased driving pressure and shear stress in the intact canine circulation.