Search PubMed⌕ Search

Biomedical subjects

U S Swarna

Publications and source records attributed to U S Swarna.

3 recordsLinked to original sources

Simultaneous assessment of myocardial perfusion and left ventricular function during transient coronary occlusion.

OBJECTIVES: We used technetium-99m sestamibi imaging to evaluate the magnitude of changes in left ventricular function and perfusion and to investigate their interdependence during transient coronary occlusion. BACKGROUND: Transient coronary occlusion during coronary angioplasty provides a unique opportunity for examining the effects of acute myocardial ischemia on left ventricular function and perfusion. METHODS: Thirty-five patients with normal left ventricular function underwent first-pass radionuclide angiography with technetium-99m sestamibi using a multicrystal gamma camera during balloon occlusion of a coronary artery. Single-photon tomography was performed 2.1 +/- 1.7 h later. Subsequently, all scans were repeated at rest. RESULTS: The mean size +/- SD of the perfusion defect during coronary occlusion was 23 +/- 18%, with significantly larger defects observed for occlusions of the left anterior descending coronary artery (39 +/- 20%) than for occlusions of the left circumflex (15 +/- 11%) or right (15 +/- 9%) coronary artery (p < 0.05). The mean change in ejection fraction from recovery to occlusion was -17 +/- 17% and was significantly larger for left anterior descending (-26 +/- 21%) and left circumflex (-15 +/- 11%) than for right (-8 +/- 10%) coronary artery occlusions (p < 0.05). For the entire group, ejection fraction during occlusion correlated significantly with perfusion defect size (r = 0.63, p = 0.0004), whereas the extent of ischemic myocardium correlated with the decrease in ejection fraction (r = 0.69, p = 0.0001). The defects present during occlusion reversed within a few hours. CONCLUSIONS: Changes in left ventricular function and perfusion develop pari passu during coronary occlusion and are more severe when the left anterior descending artery is occluded. Although a significant correlation exists between the extent of the perfusion defect and the severity of the decrease in ejection fraction, there is a substantial individual variation with respect to changes in both myocardial perfusion and ventricular function during acute coronary occlusion.

Angina Pectoris↗

Postshock sensing performance in transvenous defibrillation lead systems: analysis of detection and redetection of ventricular fibrillation.

INTRODUCTION: The sensing performance of transvenous lead systems may be adversely affected by the delivery of high-energy shocks. This may be due to the proximity of the sensing and energy-delivery electrodes on transvenous leads. METHODS AND RESULTS: The time required for detection of ventricular fibrillation and redetection after a failed first shock was compared in 93 patients with five different lead system-pulse generator combinations: Cadence--Endotak 60 series, Ventak P--Endotak 60 series, Jewel--Transvene, Cadence--TVL, and Cadence--Transvene. A total of 418 successful and 204 failed first shocks were delivered during induced ventricular fibrillation. Redetection times (RED) were consistently shorter than detection times (DET) in the Jewel-Transvene (RED minus DET: -1.9 +/- 0.8 sec, P < 0.0001), the Cadence-TVL (-1.6 +/- 1.0 sec, P < 0.0001), and the Cadence-Transvene combinations (-2.0 +/- 0.9 sec, P < 0.0004). Redetection times were not significantly different than detection times in the Cadence-Endotak combination (0.9 +/- 3.1 sec; P = 0.09). Redetection times were significantly longer than detection times in the Ventak-Endotak combination (1.2 +/- 2.3 sec; P = 0.034). Prolonged individual redetection episodes (> 8.2 sec) were observed in the Cadence-Endotak (7 [10%] of 73 episodes) and the Ventak-Endotak (4 [10%] of 39 episodes), but not in the Jewel-Transvene, the Cadence-TVL, and the Cadence-Transvene combinations. CONCLUSIONS: Redetection of ventricular fibrillation may be delayed in some transvenous lead-pulse generator combinations. Successful redetection of ventricular fibrillation following a failed first shock should be demonstrated prior to hospital discharge of patients with implantable defibrillators.

Adolescent↗