Ovarian and adnexal torsion: spectrum of sonographic findings with pathologic correlation.

OBJECTIVE: To determine the spectrum of sonographic findings on gray scale and color Doppler sonography in a series of pathologically proven cases of ovarian and adnexal torsion. METHODS: The study population included 15 patients with surgical confirmation of ovarian or adnexal torsion, or both, who underwent sonographic examination before surgery. All sonograms were reviewed retrospectively. RESULTS: Gray scale abnormalities included the following: complex masses in 11 (73%) of 15 patients, cystic masses in 3 (20%), and a solid mass in 1 (7%). Cul-de-sac fluid was present in 13 (87%) of 15 patients. Adnexal neoplasms were present in 4 (27%) of 15 (1 granulosa cell tumor and 3 dermoid cysts) on pathologic examination. Doppler findings were abnormal in 14 (93%) of 15 patients and normal in 1 (7%). Abnormal Doppler findings included no arterial and no venous flow in 6 (40%) of 15, decreased venous flow with no arterial flow in 5 (33%), decreased venous flow and decreased arterial flow in 2 (13%), and decreased arterial flow with no venous flow in 1 (7%). Small amounts of cul-de-sac fluid were present in 13 (87%) of 15 patients. CONCLUSIONS: The diagnosis of ovarian and adnexal torsion remains challenging. It cannot be based solely on the absence or presence of flow on color Doppler sonography, because the presence of arterial or venous flow does not exclude the diagnosis of adnexal torsion. Comparison with the morphologic appearance and flow patterns of the contralateral ovary will aid in diagnosis.

Adnexa Uteri↗

Prevalence of cerebral microemboli in systemic lupus erythematosus: transcranial Doppler.

OBJECTIVE: To determine the prevalence and predictors of microemboli on transcranial Doppler (TCD) in patients with systemic lupus erythematosus (SLE). METHODS: One hundred sixty-seven patients with SLE underwent TCD testing. RESULTS. Fifteen of 153 patients (9.8%) who successfully underwent TCD testing had microembolic events. Predictors of TCD microemboli included valve repair or replacement (p < 0.0001) and higher SLE Disease Activity Index (p = 0.07). Antiphospholipid antibodies and atherosclerotic plaque on carotid duplex were not associated with TCD microemboli. CONCLUSION: TCD microemboli may represent a noninvasive method to ascertain risk of stroke in SLE. TCD microemboli are not associated with traditional stroke risk factors. Longitudinal studies are needed to determine if TCD microemboli are predictive of future stroke in SLE.

Adult↗

Metastatic meningioma in fine-needle aspiration (FNA) of the lung: cytomorphologic finding.

Pulmonary metastasis of intracranial meningioma is rare. We present the cytomorphologic features of such a tumor in a 71 yr-old woman who was found to have multiple lung nodules 13 years following the resection of an atypical intracranial meningioma. Cytomorphologic features were quite distinct and included hypercellularity with large syncytial groups of monomorphic cells with epithelioid morphologic features, often in perivascular arrangements. Occasional intranuclear cytoplasmic inclusions as well as binucleated cells with wispy cytoplasmic extensions were also noted. Immunoperoxidase studies showed focal positivity for epithelial membrane antigen. The differential diagnosis includes primary or metastatic adenocarcinoma, malignant mesothelioma, and melanoma.

Aged↗

Imaging spectrum of extracapsular silicone: correlation of US, MR imaging, mammographic, and histopathologic findings.

The appearance of free silicone at mammography, ultrasonography (US), and magnetic resonance (MR) imaging is variable. The classic appearance is dense areas of opacity on mammograms, a highly echogenic pattern with or without hypoechoic masses on US images, and foci of low signal intensity on fat-suppressed T1-weighted MR images or high signal intensity on water-suppressed T2-weighted MR images. Mammography is a reliable, cost-effective, and readily available means of demonstrating silicone. The major disadvantage of US is that its accuracy depends on the capability of the operator to recognize the abnormality. Although MR imaging outperforms US or mammography in detection of implant rupture, it is not clear that MR imaging is superior in detection of free or residual silicone. The sequelae of noncontained silicone include granuloma formation, fibrosis, and migration. After extrusion from an implant, silicone migrates primarily to local sites, such as the ipsilateral chest wall and axillary nodes. Migration of silicone into the axilla can involve the brachial plexus, resulting in neuropathy. Silicone can also migrate into more distal regions, including the arm and subcutaneous tissues of the abdominal wall. Whatever the source, silicone in breast tissue interferes with the interpretation of mammographic findings.

Adult↗

US guidance for thoracic biopsy: a valuable alternative to CT.

PURPOSE: To determine the role, accuracy, and selection criteria of ultrasonographic (US) guidance for biopsy for thoracic lesions. MATERIALS AND METHODS: Imaging-guided thoracic biopsies (n = 86) were performed in 84 consecutive patients. US guidance was used for lesions abutting the chest wall; computed tomographic (CT) guidance was used for all masses surrounded by aerated lung. Mass location and size, guidance modality, histologic results, procedure time, and complications were recorded. RESULTS: Thirty-four lesions (19 parenchymal, six pleural, six chest wall, three mediastinal) were amenable to US-guided biopsy. The mean mass diameter was 4.3 cm, the mean number of passes was 3.2, and the mean procedure time was 31.4 minutes. A histologic diagnosis was achieved in 31 (91%) patients, including all with small (< 2-cm) masses (n = 9). There was one case of pneumothorax. CT guidance was used in 52 (60%) of 86 cases. Lesions were parenchymal (n = 41), pleural (n = 1), and mediastinal and hilar (n = 10). The mean diameter was 2.9 cm, the mean number of passes was 2.3, and the mean procedure time was 45.2 minutes. A histologic diagnosis was achieved in 37 (71%) patients, including 18 of 27 with a small mass. Complications included pneumothorax (n = 21) and parenchymal hemorrhage (n = 2). CONCLUSION: US is an effective and safe alternative to CT for guidance at biopsy of masses abutting the chest wall. Real-time US visualization allows accurate needle placement, shorter procedure time, and performance in debilitated and less cooperative patients.

Adolescent↗

Diagnosis and staging of ovarian cancer: comparative values of Doppler and conventional US, CT, and MR imaging correlated with surgery and histopathologic analysis--report of the Radiology Diagnostic Oncology Group.

PURPOSE: To determine the optimal imaging modality for diagnosis and staging of ovarian cancer. MATERIALS AND METHODS: Two hundred eighty women suspected to have ovarian cancer were enrolled in a prospective study before surgery. Doppler ultrasonography (US), computed tomography (CT), and magnetic resonance (MR) imaging were used to evaluate the mass; conventional US, CT, and MR imaging were used to stage spread. RESULTS: All three modalities had high accuracy (0.91) for the overall diagnosis of malignancy. In the ovaries, the accuracy of MR imaging (0.91) was higher than that of CT and significantly higher than that of Doppler US (0.78). In the extraovarian pelvis and in the abdomen, conventional US, CT, and MR imaging had similar accuracies (0.87-0.95). In differentiation of disease confined to the pelvis from abdominal spread, the specificity of conventional US (96%) was higher than that of CT and significantly higher than that of MR imaging (88%), whereas the sensitivities of MR imaging (98%) and CT (92%) were significantly higher than that of conventional US (75%). CONCLUSION: MR imaging is superior to Doppler US and CT in diagnosis of malignant ovarian masses. There is little variation among conventional US, CT, and MR imaging as regards staging.

Adult↗

Three-dimensional US of the prostate: early experience.

PURPOSE: To assess the feasibility of using a three-dimensional (3D) endorectal transducer at ultrasonography (US) in the prostate gland in a clinical setting. MATERIALS AND METHODS: Sixteen patients underwent 3D imaging of the prostate gland with a 3D endorectal probe following conventional two-dimensional (2D) US and prior to prostatic biopsy. Image acquisition was performed as a volume of data with nearly immediate reconstruction and simultaneous display of sectional anatomy in three orthogonal planes--sagittal plane, transverse or coronal plane, or any arbitrary oblique plane. Images were evaluated for presence of focal lesions, glandular volume, visualization of lateral and anterior portions of the gland, and extraglandular extension of tumor. RESULTS: Three-dimensional US allowed better visualization of the gland and focal lesions, especially on the coronally reconstructed images, which were judged superior to the sagittally or transversely reconstructed images for interpretation in 50% of the patients. Prostatic volumes obtained from 3D US were consistently smaller than volumes obtained from 2D US (20% difference, P = .006). Three-dimensional US was superior to 2D US in depicting tumor presence (nine of 10 right hemispheres, three of eight left hemispheres) and extraglandular extent of disease (three of five hemispheres). CONCLUSION: Three-dimensional endorectal prostatic US appears to be clinically feasible and easy to perform. Added anatomic information from the coronal plane may allow better depiction of tumors and extraglandular spread than is possible with current 2D techniques.

Endosonography↗

Serum CA-125 screening for ovarian cancer in patients with dermatomyositis.

Ovarian cancer is the most overrepresented malignancy diagnosed in women with dermatomyositis. Unfortunately, screening with pelvic examination rarely detects this cancer prior to the development of metastatic disease. Our objective was to examine the use of serum CA-125 antigen levels in screening patients with dermatomyositis for ovarian cancer. A single blinded, case-control study was conducted in our institution of CA-125 levels in 14 women diagnosed with dermatomyositis between 1986 and 1993, 4 of whom subsequently developed ovarian cancer. In the 4 patients who developed ovarian cancer ("cases"), CA-125 determinations were performed on serum stored 5 to 19 months prior to the diagnosis of ovarian cancer. In the remaining 10 patients ("controls"), serum was drawn for CA-125 level determination at the time of the study, and simultaneous gynecologic and endovaginal ultrasound examinations were performed to exclude clinical evidence of ovarian cancer. All CA-125 serum measurements were performed simultaneously by a technician blinded to disease status using one diagnostic kit. CA-125 was found to be elevated in 2 patients with ovarian cancer (on serum obtained 5 and 13 months prior to the date of diagnosis of ovarian cancer) and in none of the control patients without clinical or ultrasound evidence of ovarian cancer (relative risk = 20, 95% confidence interval = [0.64, 666]). In these 14 patients, the sensitivity of CA-125 elevation for detection of ovarian cancer was 50%, and specificity was 100%. Serum CA-125 screening for ovarian cancer in patients having dermatomyositis may be useful; however, prospective studies are needed to confirm this and to determine the effect of screening on cancer stage at diagnosis and long-term survival.

Aged↗

Incidence of high-grade prostatic intraepithelial neoplasia in sextant needle biopsy specimens.

OBJECTIVES: There is scant literature on the frequency of high-grade prostatic intraepithelial neoplasia (PIN) in needle biopsy specimens. These data have implications as to how often pathologists should be expected to diagnose these lesions on needle biopsy and impact on the feasibility of cancer chemoprevention trials for prostate cancer. METHODS: We reviewed 439 consecutive 18-gauge sextant needle biopsy specimens from the Johns Hopkins Hospital. RESULTS: Based on the pathology reports, high-grade PIN was recorded in 12 (2.7%) of the cases and was confirmed upon review. Following review of the slides, unequivocal high-grade PIN was found in an additional 6 cases. There were 6 other cases where the findings were borderline between high- and low-grade PIN, but which were believed to be more consistent with high-grade PIN. Considering these latter cases in conjunction with the unequivocal cases of high-grade PIN, the incidence of high-grade PIN was 5.5% (24 of 439). CONCLUSIONS: Recognizing that approximately 50% of men with high-grade PIN on needle biopsy will be found to have carcinoma on repeat biopsy, the management of high-grade PIN on biopsy will only apply to 50% of the men initially discovered with this finding. If only 2.75% of men who are biopsied eventually need therapy for high-grade PIN on needle biopsy, the number of cases needed to study the decrease of high-grade PIN following chemoprevention might be prohibitively high. If the incidence of high-grade PIN on needle biopsy requiring therapy is only 2.75%, it may also not be worthwhile developing large trials to investigate various treatment regimens for high-grade PIN found on biopsy.

Adult↗

Endometrial blood flow analysis in postmenopausal women: can it help differentiate benign from malignant causes of endometrial thickening?

PURPOSE: To determine if prominent vascularity and low pulsatility index (PI) and resistive index (RI) in endometrial arteries help differentiate carcinoma from benign lesions. MATERIALS AND METHODS: Forty-five postmenopausal women with at least 8-mm-thick endometrium at endovaginal ultrasound (US) underwent color duplex Doppler endovaginal US of the endometrium. PI and RI values were recorded from arterial waveforms generated in areas of increased vascularity. RESULTS: At color duplex Doppler endovaginal US, endometrial arterial flow was seen in 23 of 36 (64%) proved benign endometrial lesions. The range of PIs for benign lesions was 0.31-1.77 (mean, 0.72 +/- 0.33 [standard deviation]) and for RIs was 0.27-0.84 (mean, 0.48 +/- 0.13). Arterial vessels were seen in five of nine proved endometrial cancers (56%); the range of PIs was 0.42-1.17 (mean, 0.71 +/- 0.32) and for RIs was 0.34-0.69 (mean, 0.48 +/- 0.15). Differences in mean PI and RI for benign and malignant lesions were not significant. CONCLUSION: Low-impedance arterial flow is observed in various diseases of the endometrium, and there is an overlap between the PI and RI of benign and malignant lesions.

Aged↗

Single- and double- lumen silicone breast implant integrity: prospective evaluation of MR and US criteria.

PURPOSE: To evaluate the accuracy of magnetic resonance (MR) and ultrasound (US) criteria for breast implant integrity. MATERIALS AND METHODS: One hundred twenty-two single-lumen silicone breast implants and 22 bilumen implants were evaluated with surface coil MR imaging and US and surgically removed. MR criteria for implant failure were a collapsed implant shell ("linguine sign"), foci of silicone outside the shell ("noose sign"), and extracapsular gel, US criteria were collapsed shell, low-level echoes within the gel, and "snowstorm" echoes of extracapsular silicone. RESULTS: Among single-lumen implants, MR imaging depicted 39 of 40 ruptures, 14 of 28 with minimal leakage; 49 of 54 intact implants were correctly interpreted. US depicted 26 of 40 ruptured implants, four of 28 with minimal leakage, and 30 of 54 intact implants. Among bilumen implants, MR imaging depicted four of five implants with rupture of both lumina and nine of 10 as intact; US depicted one rupture and helped identify two of 10 as intact. Mammography accurately depicted the status of 29 of 30 bilumen implants with MR imaging correlation. CONCLUSION: MR imaging depicts implant integrity more accurately than US; neither method reliably depicts minimal leakage with shell collapse. Mammography is useful in screening bilumen implant integrity.

Breast Implants↗

Breast implant rupture: diagnosis with US.

PURPOSE: To characterize sonographic criteria for the detection of implant rupture. MATERIALS AND METHODS: One hundred nineteen symptomatic women (221 silicone implants) were evaluated with ultrasound (US) over 11 months to detect implant rupture. Fifty-nine breast prostheses in 31 women were surgically removed. RESULTS: Five sonographic findings associated with rupture were identified: echogenic noise, low-level homogeneous echoes within the implant, echogenic lines coursing within the implant, a contour bulge of the implant, and peri-implant fluid accumulations. The most useful finding in the detection of implant rupture was low-level homogeneous echoes, which were associated with 55% of ruptured implants and 16% of intact implants. This was statistically significant, achieving a 55% sensitivity and 84% specificity for the detection of implant rupture. Nine of 22 ruptured implants (41%) displayed none of the described criteria. CONCLUSION: US may be useful to detect implant rupture; however, a larger prospective study is necessary for adequate evaluation.