Search PubMed⌕ Search

Biomedical subjects

U Kramer

Publications and source records attributed to U Kramer.

At least 19 recordsLinked to original sources

[Cardiac MR tagging: optimization of sequence parameters and comparison at 1.5 T and 3.0 T in a volunteer study].

PURPOSE: The aim of this study was the optimization of a gradient echo (GRE) MR tagging sequence at 3.0 T in comparison to 1.5 T in order to obtain the best image contrast between the myocardium, tag lines and blood signal. Theoretically expected improvements of signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were also calculated. MATERIALS AND METHODS: 14 healthy volunteers (8 male, 6 female; mean age 43.4 +/- 10.3 years) were scanned using a 3.0 T as well as a 1.5 T whole-body system. A GRE flash-2 D tagging sequence was evaluated (midventricular short axis view) by varying the flip angle (8 - 16 degrees ), slice thickness (4 - 8 mm; fixed flip angle 1.5/3.0 T: 12 degrees /8 degrees , tag size 8 mm) and tag size (4 - 8 mm, fixed flip angle 1.5/3.0 T: 12 degrees /8 degrees , slice thickness 6 mm). The field of view, acquisition time and temporal resolution (45 ms) were kept constant. Qualitative and quantitative image analysis was performed by calculating the SNR, CNR (tag) as well as the relative contrast between the myocardium and tag lines (RCMT). RESULTS: Based on individual comparison, the best imaging protocol was found at a slice thickness of 6 mm, tag size of 8 mm, optimized flip angle of 8 degrees (3.0 T) and 12 degrees (1.5 T), respectively. Compared to 1.5 T, a significantly higher overall image score was determined (mean +/- sd; 3.2 +/- 0.2 vs. 2.7 +/- 0.4) and a strong correlation between the CNR (tag) and RCMT for flip angle alpha and the slice thickness was found. A higher field strength resulted in an 80 % increase in the CNR (tag) compared to 1.5 T (mean 10.7/6.1). Furthermore, the SNR was improved by 35 % (mean 20.6/15.3) and the RCMT by 35 % (mean 0.47/0.35). CONCLUSION: Myocardial tagging at 3.0 T has shown superior image quality in comparison to 1.5 T due to a higher baseline SNR and an improved CNR as well as RCMT. The suppressed fading of the tags enables the accessibility to the diastolic phase of the cardiac cycle.

Adult↗

[Cardiovascular whole-body MR imaging in patients with symptomatic peripheral arterial occlusive disease].

PURPOSE: To examine patients with peripheral-arterial-occlusive-disease (PAOD) for systemic effects associated with atherosclerosis using a comprehensive state-of-the-art whole-body MR examination protocol. The protocol comprises the assessment of the complete arterial vasculature (except coronary arteries), the brain, and the heart. MATERIALS AND METHODS: Multi-station whole-body 3D MR angiography was performed in sixty consecutive patients with clinical suspicion for PAOD at 1.5 T (Magnetom Avanto, Siemens, Erlangen, Germany). Functional and delayed enhancement cardiac images were acquired, as well as FLAIR images of the brain and TOF angiography of intracranial vessels. MR and DSA images were assessed by independent observers for atherosclerotic manifestations and other pathology. Sensitivity and specificity for the detection of vascular pathology was calculated for MR data using conventional DSA of the symptomatic region as standard-of-reference. RESULTS: Sensitivity and specificity for the detection of significant vascular stenosis (> 70 % luminal narrowing) was 94 % and 96 % (PPV 87 %, NPV 98 %). Significant microangiopathic tissue alterations (n = 7) and/or cerebral infarction (n = 18) were diagnosed in 23/60 patients. Thirty-eight of 60 patients presented with systolic left ventricular wall motion abnormalities. In 24 patients subendocardial or transmural delayed enhancement was detected in corresponding regions, indicating prior myocardial infarction. CONCLUSION: For patients with PAOD and suspected systemic atherosclerotic disease a comprehensive diagnosis of accompanying cardiovascular pathology and therefore staging of systemic atherosclerotic disease is feasible within one MR examination.

Aged↗

Is there any correlation between severity of epilepsy and cognitive abilities in patients with temporal lobe epilepsy?

Frequent refractory seizures may cause cognitive deterioration when they present at an early age, especially in infants. The findings of previous studies designed to examine the impact of repetitive seizures on cognition in adolescents and adults, however, have shown wide variation. We analyzed the data of neuropsychological evaluations of patients before they underwent temporal lobe resection because of refractory seizure disorder in our institution from 1998 to 2001. Forty-four consecutive patients aged 12-48 years underwent a comprehensive neuropsychological evaluation that included a battery of selected visual and verbal memory tests. Statistical analysis revealed no significant correlation between disease-related parameters, such as age of onset, duration of active disease, estimated cumulative number of complex partial seizures and secondarily generalized seizures, and the results of neuropsychological tests. These findings support the hypothesis that factors other than repetitive seizures are responsible for cognitive dysfunction among adolescents and adults.

Adolescent↗

[MR angiography and determination of the flow reserve after minimal invasive direct coronary artery bypass (MIDCAB) surgery of the left internal mammary artery in comparison to multirow CT].

PURPOSE: To evaluate graft patency, flow and flow reserve in patients with minimal invasive direct coronary artery bypass (MIDCAB) of internal mammary artery (IMA) grafts using a combined MR protocol with phase-contrast technique and MR angiography. MATERIAL AND METHODS: At a 1.5T Magnetom Sonata (SIEMENS), 19 symptomatic (angina CCS I-III, intermittent thoracic discomfort, scar disorders) patients (59.9 +/- 7.9 years old) with 19 left internal mammary artery (LIMA) grafts implanted in minimal invasive technique were examined 6.9 +/- 1.5 years post surgery. Contrast enhanced MR angiography (TR 2.5 ms, TE 1 ms, flip angle 20 (o), spatial resolution 1.4 x 0.9 x 1.0 mm(3), breath hold technique, no ECG-triggering, 25 ml Gd-DTPA) was performed to assess bypass patency. Phase-contrast flow measurements with retrospective gating (TR 41 msec, TE 3.2 msec, flip angle 30 degrees , spatial resolution 1.1 x 1.1 x 5 mm(3), temporal resolution 42 msec, venc 90 cm/sec) were applied in the IMA grafts at rest and after stress induction with dipyridamole (0.56 mg/kg/BW). For comparison, graft patency was evaluated by multidetector-row computed tomography (16-row CT). In 9 patients a selective catheter angiography was performed. RESULTS: MIDCAB grafts were occluded in 4/19 patients. In 4 patients the anastomosis to LAD was highly stenotic (> 70 %) at MDCT (2 experienced investigators in consensus reading). In MRA 9 grafts could be delineated completely including the distal anastomosis to LAD (47 %). In 9 patients the distal part could not be evaluated. In patients with patent grafts (MDCT), a significant improvement of graft flow (at rest 75.4 +/- 33.3 ml/min; after stress 202.7 +/- 49.6; P < 0.002) and flow reserve (patent grafts 3.0 +/- 1.1; stenotic grafts 1.5 +/- 0.2, P < 0.02; occluded grafts 0.9 +/- 0.2, P < 0.01) after stress induction was detected. Diastolic-to-systolic peak velocity ratios (D/S-PVR) at baseline were not significant between patent and stenotic grafts. Mean flow at baseline and after stress induction and flow reserve show a high sensitivity (91/92 /83 %) and specificity (86 /100/83 %) for detection of graft stenosis. MR angiography combined with flow reserve measurements could distinguish between occluded/stenotic and patent grafts in all MIDCAB grafts. CONCLUSION: MR imaging allows combined assessment of bypass patency and flow with flow reserve in patients after MIDCAB. The protocol of this study is applicable for the evaluation of graft patency in patients after revascularization.

Blood Flow Velocity↗

Aortic root remodeling: functional MRI as an accurate tool for complete follow-up.

BACKGROUND: After aortic valve-sparing procedures patients should be evaluated regularly because of the risk for further disease progression in the remaining aorta as well as recurrent aortic insufficiency. The purpose of this study was to evaluate the potential of functional MRI as a single examination for complete follow-up of these patients. METHODS: Twenty-two patients with a mean age of 54 years (range 30 - 66) were prospectively examined at 1, 12, 24, 36, and 74 months postoperatively, following a Yacoub aortic root remodeling operation, using a 1.5 T MRI. The original disease was chronic aneurysm of the ascending aorta or root in 17, chronic dissection in 3, and acute dissection in 2 patients. Transverse graft diameters, regurgitant fraction, LVEDV, and cardiac index were measured using cine MRI. Results were compared to spiral computed tomography and transthoracic color Doppler echocardiography. Mean time of follow-up was 24.9 months and ranged from 1 to 74 months. RESULTS: There were 2 re-operations, 2 years after primary surgery, due to high aortic insufficiency. CT and MRI measurements of graft diameters correlated well (p = 0.4544). Mean graft diameter (mean +/- SD) was 30 +/- 3.7, 33 +/- 3.4, 36.5 +/- 1.5, 37 +/- 2.8, and 38.3 +/- 2.8 mm at 1, 12, 24, 36, and 74 months, respectively, indicating a significant increase of graft diameter (p < 0.0001). Mean regurgitant fraction as determined by MRI was 14 +/- 7, 12 +/- 9, 13 +/- 9, 15 +/- 7, and 14 +/- 9 % at 1, 12, 24, 36, and 74 months, respectively. Flow based grading of aortic insufficiency by MR imaging correlated well with color Doppler echocardiography (p < 0.0001). CONCLUSIONS: MRI provides an excellent, noninvasive, comprehensive tool for follow-up after valve-sparing aortic root reconstruction. The determination of regurgitant fraction, ventricular dimensions and functions, and graft diameters allows standardized imaging protocols with a high reproducibility, which may lead to this technique being favored for the follow-up of patients after aortic root remodeling.

Adult↗

Perioperative monitoring of flow and patency in native and grafted internal mammary arteries using a combined MR protocol.

The objective of this study was to evaluate graft flow (f) and patency (p) in patients with internal mammary artery (f,p) and venous (p only) grafts using a combined MR protocol with phase-contrast technique and MR angiography. 42 patients with 42 left internal mammary artery (LIMA) and 63 venous grafts were examined pre and 6 months post coronary artery bypass graft (CABG) surgery. Phase-contrast flow measurements were applied to the IMA. Post-operatively, a contrast enhanced MR angiogram was performed to assess bypass patency. LIMA/venous grafts were occluded in 3/42 and 13/63, respectively. Flow in LIMA decreased from 19.4+/-10.4 ml min(-1) m(-2) pre-operatively to 13.4+/-9.7 ml min(-1) m(-2) post-operatively (p<0.002). In contrast, flow in the native right IMA increased from 17.6+/-8.7 ml min(-1) m(-2) pre-operatively to 24.8+/-9.0 ml min(-1) m(-2) post-operatively (p<0.001). MRI allows a combined assessment of bypass patency and flow. This study protocol may be applicable to perioperative follow-up studies in patients after CABG surgery.

Aged↗

The yield of laboratory investigations in children with infantile autism.

PURPOSE: To evaluate the yield of laboratory investigations in infantile autism. METHODS: We retrieved and evaluated the results of investigative procedures recorded in the medical files of autistic infants in four child developmental centers and two pediatric psychiatric outpatient clinics. RESULTS: One-hundred and thirty-two infants were included in the study of whom 47 (36%) underwent autistic regression at an average age of 20 months. The investigative procedures included electroencephalogram (n = 132), neuroimaging (n = 70), genetic studies to detect Fragile-X (n = 59) and a metabolic workup (n = 53). Except for the molecular diagnosis that revealed Fragile-X syndrome in two children (3%), all other tests were negative. The two infants with the Fragile-X syndrome belonged to the non-regressive group. CONCLUSIONS: The only investigative study that contributed to the diagnosis of autistic infants was the molecular diagnosis detecting Fragile-X. In spite of the high frequency of epilepsy and epileptiform abnormalities in the electroencephalograms of autistic children in general, the contribution of epilepsy, both clinical and subclinical, to the etiology of autism is apparently minimal.

Adolescent↗

[TrueFISP MR imaging to determine the influence of hemodialysis on the myocardial functional parameters in patients with terminal renal insufficiency].

PURPOSE: To assess the characteristic signs of uremic cardiomyopathy in patients with chronic renal failure (CRF) in comparison with healthy volunteers and to determine changes of left ventricular (LV) functional parameters in patients undergoing hemo-dialysis (HD). METHODS AND MATERIALS: Using a 1.5 T Magnetom Sonata system (Siemens, Erlangen), cardiac MR imaging was performed on 26 patients (20 men, 6 women, mean age 54.7 years) and 14 volunteers (8 men, 6 women, mean age 27.7 years). Single-slice true FISP sequences (TR 3.2 ms, TE 1.6 ms, flip angel 58 degrees, matrix 256 x 208, slice thickness 5 mm) were used to obtain contiguous short axis slices covering the whole left ventricle. Patients were examined before and immediately after HD. Cardiodynamic parameters [end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), myocardial mass (MM), cardiac output (CO)] were calculated using the modified Simpson's rule (Argus Software, Siemens). Patient data were compared to reference values taken from healthy volunteers. RESULTS: As a consequence of HD, significant differences (p < 0.01) were observed for EDV (150 + 47 ml/114 + 49 ml), ESV (71 + 46 ml/60 + 56 ml), SV (79 + 25 ml/57 + 27 ml) and CO (3.6 + 1.0 l/min*m (2)/2.6 + 1.1 l/min*m (2)). Although EF (56 + 15 %/53 + 18 %) was decreased after HD, values did not differ significantly (p > 0.05). MM (148 + 47 g/148 + 52 g) and myocardial mass index (80.7 +/- 27.4 g/m (2)/80.1 +/- 9.1 g/m (2)) did not change before and after HD. In all patients, signs of LV-hypertrophy (LVH) and increased CO were diagnosed compared to reference values. In 8 of 26 patients, additional pathology, such as valvular dysfunction or global cardiac insufficiency, was detected. CONCLUSION: Cardiac MRI is an accurate tool to identify uremic cardiomyopathy in patients with chronic renal failure undergoing HD. LV functional parameters could be monitored reliably.

Adult↗

[Clinical implication of parameter-optimized 3D-FISP MR angiography (MRA) in children with aortic coarctation: comparison with catheter angiography].

PURPOSE: To implement parameter-optimized 3D-FISP MR angiography (MRA) with interleaved double-slab excitation and to compare the result with catheter angiography in children with aortic coarctation. MATERIALS AND METHODS: Eighteen children aged 2 - 15 years (mean 9.1 years) underwent MR imaging on a 1.5T body scanner (Magnetom Vision, Siemens, Germany). All patients had undergone correlative catheter angiography. T1-weighted turbo spin echo (TSE) images (TR 600 ms, TE 17 ms, flip 160 degrees, slice thickness 2 - 4 mm) were obtained in axial and parasagittal orientation, followed by an optimized 3D-FISP MR angiography in a sagittal plane (TR 12.5 ms, TE 5.5 ms, flip 22 degrees, matrix 256 x 256, slice thickness 1.25 mm). All children were sedated but on spontaneous breathing. Image quality was graded by two experienced reviewers using a 4-point scoring system. Source images and reformatted maximum intensity projections (MIP) were analyzed for blood-tissue contrast as well as size and focal stenoses of the aortic arch. RESULTS: Aortic coarctation was found in 13 of 18 patients, using the 3D-FISP MRA. A high correlation value (r = 0.96) was found compared to catheter angiography. Image quality was high in 94 % with well defined blood-tissue contrast in all cases. The sensitivity to flow and breathing motion was low. Examination time was about 15 minutes depending on volume of interest and heart rate. Diagnostic accuracy has shown improvement using a combined analysis of source and MIP images. The mentioned technique has provided an excellent display of thoracic vasculature. CONCLUSION: MR imaging represents an excellent tool for non-invasive examination of the cardiovascular system of children. The 3D-MRA allows the recording of a large 3D data set without the use of contrast agent and within an adequate measurement period, particularly in small infants unable to hold their breath. In addition, hemodynamic significance of aortic coarctation, the existence of collateral vessels and other congenital heart diseases can be described reliably by using this technique.

Adolescent↗

Radiopaque markers in endovascular stents--benefit and potential hazards.

AIM: The primary objective of this study was to evaluate the impact of radiopaque markers on stent visibility. The secondary objective was to investigate the impact of such radiopaque markers on localized corrosion at the stent corpus-marker interfaces. MATERIAL AND METHODS: The radiopacity of the following stents was evaluated at different fluoroscopy modes (spotfilm, continuous fluoroscopy, 15 p/s, 7.5 p/s, 3 p/s): Memotherm Flexx (FX), Memotherm Luminexx (LX)(Bard), SMART (SM), SMARTeR (SMR)(Cordis). Four readers evaluated a total of 3200 images (160 per stent per fluoro mode) according to the following radiopacity score (RS): 0 = no stent visible, 1 = poor, 2 = acceptable, 3 = good, and 4 = very good stent visibility. LX and SMR stents (n = 5/group) were subjected to potentiodynamic polarization testing in de-aerated Hanks salt solution at 37 degrees C using a potentiostat. Palmaz-Schatz stents (n = 3) were used as the control group for comparative evaluation. The corrosion current density (I corr ) and the breakdown value (E bd ) were compared parameters of interest. RESULTS: At the spotfilm mode the LX, the SM and the SMR were rated well to very well visible in 99 %, 96 %, 96 %, and the FX only in 64 %. At 7.5 p/s (standard fluoro mode) the LX was considered to be well to very well visible in 77 %, followed by the SMR in 12.5 %, the SM in 1 %, and the FX in 0 %. The SMR stents exhibited the highest E bd values (802 +/- 112 mV vs SCE), while the LX stents exhibited the lowest E bd values (155 +/- 38 mV vs SCE). Also, the average E bd values for the SMR stents were better than those exhibited by the PS stents (503 +/- 107 mV vs SCE). CONCLUSION: Stent radiopacity can be increased significantly with the help of radiopaque markers (p < 0,0001 LX vs. FX). However, the surface condition of the stent corpus and the mode of attachment of the marker onto the corpus may have a significant impact on the uniformity of the final corrosion behavior. It is not feasible to determine the clinical impact of this localized corrosion behavior from this in vitro study. Further experimentation is recommended to ascertain the same.

Coated Materials, Biocompatible↗

Androgens shorten the longevity of women: sopranos last longer.

Earlier we found that longevity of castrati was identical to that of intact singers. These findings were in disagreement with the prevailing concept that testosterone might shorten life and might be responsible for the shorter life expectancy of men compared to women. We have now continued our research into the life expectancy of singers, considering them as a paradigm of nature to investigate life-long effects of sex hormones, and resulting in the finding that sopranos, being more oestrogenised, live significantly longer than altos who are more androgenised, while basses, more androgenised, show a tendency towards a longer life than tenors, who are less androgenised. These findings, supported by results of epidemiological investigations indicate that women are protected from cardiovascular diseases, diabetes and osteoporosis by higher oestrogen levels, while the same effect maybe exerted in men by testosterone.

Aged↗

[Multislice TrueFISP-MR imaging for identifying stress-induced myocardial functional disturbances in coronary heart disease].

PURPOSE: This study assesses the left ventricular function using a new multislice cine sequence and determines the diagnostic accuracy of stress-induced wall motion abnormalities in patients with coronary artery disease (CAD). MATERIALS AND METHODS: 15 patients (mean age 57.7 years) with angiographically proven CAD were examined on a 1.5 T whole body system (Magnetom Sonata, Siemens, Erlangen) at rest and during dipyridamole-induced (0.56 mg/kg body weight) stress. Left ventricular function was determined using a multislice (steady-state) sequence (TR 2.3 ms, TE 1.15 ms, slice thickness 10 mm, temporal resolution 77 ms) as well as a standard single-slice true FISP 2D sequence (TR 3.2 ms, TE 1.6 ms, slice thickness 5 mm, temporal resolution 45 ms) as reference. RESULTS: Both cine sequences provide high sensitivity and excellent correlation (r = 0.95) with angiographic findings for the detection of regional wall motion abnormalities. However, the measurement of functional parameters yielded significant differences. End-systolic left ventricular volumes (ESV) were systematically overestimated in the multislice images (mean 78 ml, + 5.8 %) compared with the reference single-slice images (mean 74 ml) (p < 0.05). This resulted in underestimation of the ejection fraction with multislice images (mean 40 %, - 11.3 %) compared with single-slice images (mean 46 %) (p < 0.05). CONCLUSION: The multislice sequence results in a substantial reduction of imaging time and breath-hold periods necessary to cover the left ventricle for functional assessment. The multislice sequence yields adequate images, especially for qualitative determination of wall motion abnormalities. Due to the reduced spatial and temporal resolution of the multi-slice sequence, however, some uncertainty concerning the functional parameters has to be taken into account.

Adult↗

Subacute myocardial infarction: assessment by STIR T2-weighted MR imaging in comparison to regional function.

PURPOSE: Increased T2 signal intensity (SI) can be regularly observed in myocardial infarction. However, there are controversial reports about the relationship of elevated T2 SI to myocardial viability and some authors propose that high T2 SI serves as a sign of irreversible myocardial injury. This study investigates increased T2 SI compared to myocardial function in patients with reperfused subacute myocardial infarction. Preserved function was used as criterion for viability. METHODS: Ten healthy volunteers and 17 patients with myocardial infarction and patent infarct related coronary artery were examined on a 1.5 T Magnetom Vision system (Siemens). For T2-weighted MR imaging a breath-hold STIR sequence with dark-blood preparation was used. Cine FLASH 2D imaging was applied to assess myocardial function. Signal-to-noise (S/N) in STIR T2 images was measured in normal and infarcted regions and subsequently identified by two independent observers. Based on a 20 segment model of the left ventricle findings were compared to regional myocardial function. RESULTS: Elevated STIR T2 SI was found in all 17 patients and observed in 27% (204/754) of segments. S/N of normal myocardium was 5.1 +/- 0.7 in volunteers and 4.9 +/- 0.8 in patients (P = NS). Infarcted myocardium presented with significantly increased S/N 12.8 +/- 1.9 (P < 0.0001). Significant transmural elevation of T2 SI was noted in 32% of segments with preserved systolic function. CONCLUSION: Increased STIR T2 SI can be observed transmurally in post-ischemic myocardial regions with preserved function. It therefore cannot be used as an exclusive marker for the non-viable region.

Aged↗

Absence seizures aggravated by valproic acid.

PURPOSE: To report on pediatric patients with absence epilepsy who experienced absence seizure aggravation while receiving valproic acid (VPA). METHODS: The charts of all children from four pediatric epilepsy clinics receiving VPA for absence epilepsy were reviewed. Patients were evaluated and followed up between 1994 and 2000. RESULTS: Eight cases (six boys) of absence seizure aggravation were detected. Mean age at seizure onset was 5.8 years (range, 3-12 years). Six patients had simple absence seizures, one had myoclonic absences, and one had absences with automatisms. The electroencephalogram in all cases depicted generalized 3-Hz spike-and-wave activities. All eight patients experienced an increase in the frequency of absence seizures within days of VPA introduction. Dose increments resulted in further seizure aggravation. Serum levels of VPA were within therapeutic range in all patients. No case was attributed to VPA-induced encephalopathy. All patients improved on VPA discontinuation. In five children, VPA was reintroduced, resulting in further seizure aggravation. CONCLUSIONS: VPA can occasionally provoke absence seizure aggravation in patients with absence epilepsy.

Acute Disease↗

Transient oromotor deficits in children with benign childhood epilepsy with central temporal spikes.

PURPOSE: To describe transient oromotor deficits in benign childhood epilepsy with centrotemporal spikes (BCECTS), an idiopathic age-specific epileptic syndrome with a benign course. METHODS: Five children with BCECTS and intermittent dysarthria and drooling not in the context of typical clinical seizures are presented. RESULTS: The periods of oromotor deficits correlated with increased seizure frequency in all children. Concomitant EEGs that were recorded during periods of dysarthria in four of the children revealed focal electrographic seizures. The reported children did not differ from other patients with BCECTS in any other respect. CONCLUSIONS: Transient oromotor dysfunction is a rare ictal phenomenon that occurs in children with BCECTS with no other unique clinical features.

Adolescent↗

[2D-phase contrast flow evaluation and contrast-enhanced MR angiography for perioperative assessment of internal mammary artery grafts].

PURPOSE: To evaluate LV functional parameters, graft flow and patency in patients with IMA grafts using a combined MR protocol with phase-contrast technique and contrast enhanced MR angiography. MATERIAL AND METHODS: Using a 1.5 T MR system 27 patients with 27 left internal mammary artery (LIMA) and 41 venous grafts were examined before and 6 months after CABG surgery. A T(1)w-TSE sequence (slice thickness 5 mm) was applied for morphological imaging. LV function (EF, CO) was evaluated on cine images (segmented FLASH 2D, TR(eff) 11 ms, TE 4.8 ms, flip angle 25 degrees ). A phase-contrast FLASH 2D (TR 24 ms, TE 5 ms, flip angle 20 degrees ) sequence was applied for aortic and IMA flow measurements. Postoperatively, a contrast enhanced FLASH 3D MR angiography (TR 3.8 ms, TE 1.4 ms, flip angle 30 degrees ) with 25 ml Gd-DTPA was performed to assess bypass patency. RESULTS: In patients with reduced LV function (ejection fraction < 50 %) an improvement of the ejection fraction from 38.4 +/- 10.3 % to 49.8 +/- 15.3 % (p < 0.05) was found postoperatively. LIMA grafts were occluded in 1/27 patients, while 6/41 venous grafts were occluded. Distal LIMA anastomoses were demonstrated in 33 % by MRA. Flow of LIMA decreased from 21.2 +/- 11 ml/min/m(2) preoperatively to 14.4 +/- 9.6 ml/min/m(2) postoperatively (p < 0.01). CONCLUSION: MR imaging allows accurate combined assessment of LV function, bypass patency and flow. The protocol of this study may be applicable for perioperative follow-up studies in patients after CABG surgery.

Aged↗

Surgical treatment of hypothalamic hamartoma and refractory seizures: a case report and review of the literature.

Refractory gelastic seizures are often associated with hypothalamic hamartoma (HH). Presurgical evaluation in such children often points to a distinct cortical region as the source of the seizures. A case of a child with HH and refractory seizures is presented. Video-EEG monitoring revealed a well-defined epileptic focus in the left frontal region. In accordance with the current understanding of the nature of hamartoma-related seizures, the hamartoma was resected. Follow-up evaluations revealed a marked improvement in seizure frequency and global functioning.

Child, Preschool↗

No evidence of epilepsy following endoscopic third ventriculostomy: a short-term follow-up.

Patients with ventriculo-peritoneal shunts are predisposed to various complications, including the appearance of seizures over time. The high rate of complications prompted an interest in alternative procedures such as endoscopic third venticulostomy (ETV) in selected patients. From 1996 to 1998, 42 patients underwent ETV in our center. Of the 27 operated children who were followed for an average of 32 months, none experienced seizures during that time. We conclude that, in addition to other benefits, ETV minimizes the risk of epilepsy following shunt insertion, probably due to the lack of direct cortical insult.

Child↗