Coronary Stenting for Refractory Coronary Vasospasm of Proximal Left Anterior Descending Artery.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to U Kaul.
Explore the source record for details and available documents.
In animal models of coronary restenosis, intravascular red light therapy (IRLT) using a diode laser source has been shown to reduce neointimal hyperplasia following balloon-induced injury and coronary stenting. We studied the safety and efficacy of catheter-based IRLT for preventing restenosis after coronary stenting in 22 patients with angina pectoris. IRLT was performed using a diode laser (650 nm) at an energy level of 10 megawatts delivered through a rapid exchange balloon system containing the fiberoptics. The procedure was successful in all patients, with no procedural or in-hospital complications. Two patients with recurrence of symptoms had angiography at 3 and 4.1 months respectively. Angiographic follow-up was also done after 6 months in the 20 remaining asymptomatic patients. The mean minimal lumen diameter (MLD) for the whole group at 6 months follow-up was 2.57 +/- 0.62 mm. The calculated late lumen loss was 0.49 +/- 1.12 mm with a late loss index of 0.21 +/- 0.54. Four patients (2 symptomatic and 2 asymptomatic) in the series developed angiographic restenosis. Clinical events at follow-up of 10.9 +/- 3.5 months were repeat angioplasty in 2 patients for symptomatic restenosis with a 91% event free survival. These preliminary results demonstrate that IRLT after coronary artery stenting is safe and feasible; it is associated with low rates of angiographic indices of restenosis.
Explore the source record for details and available documents.
We performed transcatheter alcohol ablation of the septum in a case of hypertrophic obstructive cardiomyopathy. The patient showed marked reduction in LVOT gradient; however, he developed complete atrioventricular (AV) dissociation following the procedure, requiring AV sequential pacing. This important complication of this novel technique is highlighted.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
We investigated the possible association of post catheterization hypotension/bradycardia and neurocardiogenic syncope. Head up tilt test (HUTT) was performed in 12 consecutive patients (age 32Ð65 years) who developed transient hypotension (systolic blood pressure < 80 mmHg) and/or bradycardia (heart rate < 50/min) with or without syncope following a percutaneous coronary intervention. Ten patients had undergone percutaneous transluminal coronary angioplasty (PTCA) with stent implantation and one each PTCA alone and diagnostic coronary angiography. This event occurred at the time of sheath removal in 7 patients (58%). HUTT was performed with and without intravenous edrophonium (10 mg intravenous). The tilt test was negative in all patients. Post-catheterization hypotension/bradycardia responds promptly to conservative measures and it is unclear whether this is related to neurocardiogenic syncope.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The deliverable catheter length of the Palmaz-Schatz stent delivery system is significantly limited by the protective sheath and clamshell device. This limitation must be considered when planning distal stent placement, especially in bypass graft lesions. A technique for shortening the guide catheter without losing guidewire position is described.
A case of embolization of an unexpanded Wiktor stent while attempting to traverse an expanded Wiktor stent is reported. The embolized stent was subjected to longitudinal axial traction, using a balloon catheter to cause stretching and partial unraveling. This partially unraveled stent was deployed across the dissection to scaffold it. The patient had no postprocedure complications.
Ten patients (median age 36 yr, 5 male) with idiopathic IVC obstruction underwent balloon angioplasty followed by placement of a self-expanding stent due to unfavourable lesion characteristics. Six had total occlusion, 5 had restenosis (including 2 with total occlusion), and 1 had a suboptimal result after initial dilatation. Median minimum IVC diameter increased from 0 to 14.5 mm, and the median gradient across the lesion decreased from 16.5 to 1 mmHg. Follow-up venography (median interval 69 d) in six patients revealed no restenosis with further enlargement at the lesion site (median 4.5 mm) and abolition of gradients. Follow-up ultrasound in nine patients revealed no restenosis in the IVC. One patient died 6 mo after the procedure with acute Budd-Chiari syndrome due to hepatic vein occlusion. Autopsy revealed a widely patent stent with hepatic vein thrombus. Stent implantation is useful in the management of IVC obstruction with prior restenosis, total occlusion, or suboptimal result of balloon angioplasty.
Head-up tilt testing is a reliable diagnostic tool for patients with recurrent unexplained syncope. It has also been used to assess the drug efficacy for the treatment of patients with syncope. The objective of this study was to assess the efficacy of verapamil compared with metoprolol in a randomized crossover design for patients with syncope and a positive tilt test response. Twenty-eight patients with a positive head-up tilt test were randomized to receive either metoprolol or verapamil; the test was repeated after 7 days of therapy. Of the 15 patients initially given metoprolol, 2 (13.3%) did not respond; both were crossed over to verapamil, to which they remained unresponsive. Of the 13 patients who initially received verapamil, 8 (61%) did not respond; after crossing over to metoprolol therapy, 1 remained unresponsive. Overall, 20 of 23 patients receiving metoprolol had negative results on repeat tilt testing, whereas only 5 of 15 patients receiving verapamil had negative results (p < 0.001). In conclusion, the results of this study suggest that verapamil is considerably less efficacious than metoprolol in managing neurocardiogenic syncope.
We report a case of incessant ventricular tachycardia with right bundle branch block and left axis deviation morphology resulting in severe LV dysfunction and congestive heart failure. Radiofrequency ablation of the appropriate site in the region of posteroapical part of the LV septum resulted in the cure of the arrhythmia. On a 3-month follow-up, the LV size and function returned to normal.
Explore the source record for details and available documents.