Search PubMed⌕ Search

Biomedical subjects

U J Schoepf

Publications and source records attributed to U J Schoepf.

At least 19 recordsLinked to original sources

A retrospectively ECG-gated multislice spiral CT scan and reconstruction technique with suppression of heart pulsation artifacts for cardio-thoracic imaging with extended volume coverage.

A method for cardio-thoracic multislice spiral CT imaging with ECG gating for suppression of heart pulsation artifacts is introduced. The proposed technique offers extended volume coverage compared with standard ECG-gated spiral scan and reconstruction approaches for cardiac applications: Thin-slice data of the entire thorax can be acquired within one breath-hold period using a four-slice CT system. The extended volume coverage is enabled by a modified approach for ECG-gated image reconstruction. For a CT system with 0.5-s gantry rotation time, images are reconstructed with 250-ms image temporal resolution. Instead of selecting scan data acquired in exactly the same phase of the cardiac cycle for each image as in standard ECG-gated reconstruction techniques, the patient's ECG signal is used to omit scan data acquired during the systolic phase of highest cardiac motion. With this approach cardiac pulsation artifacts in CT studies of the aorta, of paracardiac lung segments, and of coronary bypass grafts can be effectively reduced.

Aortic Diseases↗

[Diagnosis of lung embolism with multislice spiral CT].

In recent years CT has been established as the method of choice for the diagnosis of central pulmonary embolism to the level of the segmental arteries. The key advantage of CT over competing modalities is the reliable detection of relevant alternative or additional disease causing the patient's symptoms. Although the clinical relevance of isolated peripheral emboli remains unclear, the alleged poor sensitivity of CT for the detection of such small clots has to date prevented the acceptance of CT as the gold standard for diagnosing pulmonary embolism. With the advent of multislice CT we can now cover the entire chest of a patient with 1-mm slices within one breath-hold. In comparison with thicker sections the detection rate of subsegmental emboli can be significantly increased with 1-mm sections. In addition the interobserver correlation which can be achieved with 1-mm sections by far exceeds the reproducibility of competing modalities. Meanwhile use of multislice CT for a combined diagnosis of pulmonary embolism and deep venous thrombosis with the same modality appears to be clinically accepted. In the vast majority of patients who receive a combined thoracic and venous multislice CT examination the scan either confirms the suspected diagnosis or reveals relevant alternative or additional disease. The therapeutic regimen is usually chosen based on the functional effect of embolic vascular occlusion. With the advent of fast CT scanning techniques, also functional parameters of lung perfusion can be non-invasively assessed by CT imaging. These advantages let multislice CT appear as an attractive modality for a non-invasive, fast, accurate and comprehensive diagnosis of pulmonary embolism, its causes, effects and differential diagnoses.

Humans↗

Multislice CT imaging of pulmonary embolism.

In recent years CT has been established as the method of choice for the diagnosis of central pulmonary embolism (PE) to the level of the segmental arteries. The key advantage of CT over competing modalities is the reliable detection of relevant alternative or additional disease causing the patient's symptoms. Although the clinical relevance of isolated peripheral emboli remains unclear, the alleged poor sensitivity of CT for the detection of such small clots has to date prevented the acceptance of CT as the gold standard for diagnosing PE. With the advent of multislice CT we can now cover the entire chest of a patient with 1-mm slices within one breath-hold. In comparison with thicker sections, the detection rate of subsegmental emboli can be significantly increased with 1-mm slices. In addition, the interobserver correlation which can be achieved with 1-mm sections by far exceeds the reproducibility of competing modalities. Meanwhile use of multislice CT for a combined diagnosis of PE and deep venous thrombosis with the same modality appears to be clinically accepted. In the vast majority of patients who receive a combined thoracic and venous multislice CT examination the scan either confirms the suspected diagnosis or reveals relevant alternative or additional disease. The therapeutic regimen is usually chosen based on the functional effect of embolic vascular occlusion. With the advent of fast CT scanning techniques, also functional parameters of lung perfusion can be non-invasively assessed by CT imaging. These advantages let multislice CT appear as an attractive modality for a non-invasive, fast, accurate, and comprehensive diagnosis of PE, its causes, effects, and differential diagnoses.

Humans↗

Multi-slice computed tomography as a screening tool for colon cancer, lung cancer and coronary artery disease.

Recent promising trials that use low-dose CT for the early detection of lung cancer have reinvigorated the interest in screening approaches. At the same time the development of fast image acquisition techniques, such as multislice CT, have sparked renewed interest in cardiac imaging within the radiological community. In addition to special cardiac capabilities, multislice CT has several other features such as high acquisition speed and low-dose requirements that may make this modality a universal radiological screening tool. Non-invasive disease detection is the radiologist's domain. In this paper we identify criteria for effective screening and apply these criteria to screening approaches with multislice CT when used for detection of three disease entities: colon cancer; lung cancer; and cardiovascular disease.

Colonic Neoplasms↗

Methods for quantification of coronary artery calcifications with electron beam and conventional CT and pushing the spiral CT envelope: new cardiac applications.

Detection of coronary artery calcifications with slice by slice prospective ECG triggering is feasible with electron beam CT as well as with single and multi-row-detector CT (MDCT). The radiation exposure to the patient to obtain comparable image quality is similar for all three modalities utilizing this prospective acquisition technique. Alternatively, coronary screening can be performed by MDCT with retrospective EKG spiral gating. Radiation exposure to the patient with this technique is significantly higher than with prospective triggering. Nevertheless, acquisition of the entire volume of the heart with retrospective gating holds promise to improve reproducibility of coronary calcium measurements, especially in patients with a low amount of coronary calcium and in patients with atrial fibrillation. If retrospective gating is used for CT angiography (CTA) with MDCT this allows to use thin slices (1.25 mm) and to perform the acquisition within one breath hold period (app. 35 s). This technique is currently limited by the temporal resolution per slice (250 ms). In order to achieve diagnostic image quality the heart rate of the patient thus needs to be sufficiently low. Therefore, in cases with heart rates significantly higher than 70 beats/min betablocker have to be administered for patient preparation as long as there are no contraindications for such a regimen. Because of low image noise and high spatial resolution CTA with MDCT is able to display the entire extent of atherosclerosis allowing to visualize calcified as well as non-calcified plaques of the coronary arteries. Under clinical conditions CTA has the potential to accurately rule out or diagnose significant coronary stenoses of the proximal and mid-segments of the coronary artery tree when compared to conventional selective coronary angiography.

Artifacts↗

[Evaluation of an electromagnetic virtual target system (CT-guide) for CT-guided interventions].

PURPOSE: Evaluation of the accuracy of a new electromagnetic target system for interventional CT-guided procedures with virtual navigation in a previously acquired helical CT. MATERIAL AND METHODS: The new target system CT-Guide 1010 (Ultraguide, Tirat Hacarmel, Israel) for CT-guided interventions was adapted to the video signal of the Somatom Plus 4 and Volume Zoom (Siemens, Erlangen, Germany). A helical CT-dataset including skin-based sensor cubes was transferred to the integrated navigation system inside the scanner room. 50 image-guided interventions and biopsies were performed outside the gantry using virtual navigation to reach the lesion. The accuracy of the procedures was evaluated using documentation of the needle tip with CT-fluoroscopy, results of histology, and follow-up. RESULTS: The deviation between planned and documented needle tip was 2.2 +/- 2.1 mm in 50 procedures. Time between the end of planning-CT and needle positioning using the system was 13 minutes. There were no complications due to the use of the system. CONCLUSION: The CT-Guide allows for virtual real-time navigation with high accuracy. Advantages are the free needle angulation without gantry tilt, use of optimal CT perfusion phase for virtual navigation, and reduction of radiation exposure to the patient and interventionalist.

Adult↗

ECG-gated reconstructed multi-detector row CT coronary angiography: effect of varying trigger delay on image quality.

PURPOSE: To evaluate the effectiveness of electrocardiographically (ECG)-gated retrospective image reconstruction for multi-detector row computed tomographic (CT) coronary angiography in reducing cardiac motion artifacts and to evaluate the influence of heart rate on cardiac image quality. MATERIALS AND METHODS: Sixty-five patients with different heart rates underwent coronary CT angiography. Raw helical CT data and ECG tracings were combined to retrospectively reconstruct at the defined consecutive z position with a temporal resolution of 250 msec per section. The starting points of the reconstruction were chosen between 30% and 80% of the R-R intervals. The relationships between heart rate, trigger delay, and image quality were analyzed. RESULTS: Optimal image quality was achieved with a 50% trigger delay for the right coronary artery and 60% for the left circumflex coronary artery. Optimal image quality for the left anterior descending coronary artery was equally obtained at 50% and 60% triggering. A significant negative correlation was observed between heart rate and image quality (P <.05). The best image quality was achieved when the heart rate was less than 74.5 beats per minute. CONCLUSION: To achieve high image quality, the heart rate should be sufficiently slow. Selection of appropriate trigger delays and a decreasing heart rate are effective to reduce cardiac motion artifacts.

Adult↗

Coronary artery calcium measurement: agreement of multirow detector and electron beam CT.

OBJECTIVE: The purpose of our study was to establish the most suitable algorithm to compare coronary artery calcium measurements performed with electron beam CT and multirow detector CT for the assessment of coronary artery disease. SUBJECTS AND METHODS: Coronary artery screening was performed in 100 patients with both electron beam and multirow detector CT. The images were transferred to a dedicated workstation for determination of the calcium score, volume, mass, density, and number of lesions. In addition to the traditional threshold of 130 H, the score of multirow detector CT studies was reevaluated at a threshold of 90 H. Fifty-nine of the patients underwent conventional coronary catheterization. Receiver operating characteristic curve analysis of the different scoring algorithms for detection of significant coronary artery stenosis was performed. RESULTS: The correlation between electron beam CT and multirow detector CT was high for every quantification algorithm. Determination of the score and the number of lesions with multirow detector CT revealed a systematic error of the measurement compared with electron beam CT. The areas under the curve in the receiver operating characteristic curve analyses for electron beam and multirow detector CT were similar for the score, volume, and mass, whereas they were lower for the density. No significant difference was found for the areas under the curve between scores using a 130-H and those using a 90-H threshold. CONCLUSION: Volume and mass indexes are superior to the traditional score, density, and number of lesions for comparing the results of electron beam and multirow detector CT and for determining significant coronary artery disease.

Adult↗

Multislice helical CT of focal and diffuse lung disease: comprehensive diagnosis with reconstruction of contiguous and high-resolution CT sections from a single thin-collimation scan.

OBJECTIVE: We tested breath-held 1-mm multislice helical CT for obtaining both contiguous and high-resolution CT sections of the chest from a single set of raw data. SUBJECTS AND METHODS: Seventy patients with suspected focal and diffuse lung disease were allocated into two groups for comparison. The first group (n = 35) underwent multislice helical CT of the chest with 1-mm collimation and a pitch of 6. From the raw data, 5-mm contiguous and 1.25-mm high-resolution CT sections were reconstructed. The second group (n = 35) underwent conventional single-slice helical CT and high-resolution CT. High-resolution CT sections and 5-mm scans were rated for overall image quality, spatial resolution, subjective signal-to-noise ratio, diagnostic value, depiction of bronchi and parenchyma, and motion and streak artifacts. The 5-mm scans were also rated for contrast resolution and depiction of the heart and vessels. Radiation dose was calculated. RESULTS: We rated 5-mm multislice helical CT superior to 5-mm single-slice helical CT, having a significantly higher total score (p = 0.0001). No significant difference (p = 0.986) was found between multislice and single-slice high-resolution CT sections. Radiation dose was 5.55 mSv for multislice helical CT and 5.50 mSv for single-slice helical CT. CONCLUSION: Contiguous chest scans of superior quality and high-resolution CT sections of equal image quality compared with single-slice helical CT can be obtained using multislice helical CT. Therefore, a comprehensive diagnosis is feasible in patients with suspected focal and diffuse lung disease by obtaining a single scan.

Adult↗

[Initial experiences with multi-slice detector spiral CT in diagnosis of arteriosclerosis of coronary vessels].

PURPOSE: Multi-row-detector-spiral-CT (MSCT) allows for 250 ms effective exposure time. The purpose of this study was to demonstrate the possibilities and limitations of this CT technology for non enhanced and contrast enhanced investigation of the coronary arteries. METHODS: Investigation of the coronary arteries without contrast medium for quantification of coronary calcifications was performed in an obese patient (140 kg) with MSCT and electron beam CT (EBCT). In 56 patients contrast enhanced CT angiography of the coronary arteries was performed to determine image quality depending on the heart rate. RESULTS: In the obese patient superior image quality could be achieved with MSCT allowing for reliable quantification of coronary calcifications. With MSCT angiography of the coronary arteries good image quality was achieved in patients with a heart rate of 59 +/- 8 beats per minute. CONCLUSION: Even if there are limitations in patients with higher heart rates with an effective exposure time of 250 ms MSCT has clear advantage of image quality in the assessment of non enhanced and contrast enhanced coronary arteries.

Adult↗

Visualization and quantification of coronary calcifications with electron beam and spiral computed tomography.

This contribution reviews the pathology and morphology of coronary calcifications. It summarizes the indications for investigation of the coronary arteries. The standard protocols for scan acquisition using electron beam and conventional computed tomography are described as well as various methods for evaluation such as the traditional Agatston scoring method and the newer three-dimensional scoring algorithms. Guidelines for interpreting scores are also reviewed. Major limitations of the reproducibility of the calcium score measurement are summarized. Future aspects of multirow-detector spiral computed tomography with retrospective electrocardiographic triggering for quantifying coronary calcium are discussed.

Calcinosis↗

Current development of cardiac imaging with multidetector-row CT.

Multidector-row CT (MDCT) with retrospective ECG gating allows scanning the entire heart with 1.25 mm slice thickness and 250 ms effective exposure time within 35 s investigation time. The resulting images allow for an accurate high-resolution assessment of morphological detail of both the coronary arteries and the cardiac chambers. Performing a contrast-enhanced MDCT angiography (MD-CTA) in addition to a non-enhanced scan for the detection and quantification of coronary calcifications may be indicated in patients with atypical chest pain and in young patients with high cardiovascular risk. This group of patients may show non-calcified plaques as the first sign of their coronary artery disease. As the proximal part of the coronary arteries is well displayed by MD-CTA it also helps to delineate the course in anomalous coronary vessels. Additional information is drawn from the preoperative use of MD-CTA do determine the distance of the left internal mammarian artery to the left anterior descending coronary artery prior to minimal invasive bypass grafting. Additional indications for MD-CTA are the non-invasive follow up after venous bypass grafting, PTCA, and coronary stent interventions. MD-CTA allows following the course of the coronary vessels to the level of third generation coronary segmental arteries. A definite diagonis to rule out coronary artery disease can be reliably made in vessels with a diameter of 1.5 mm or greater. With MDCT a number of different atherosclerotic changes can be observed in diseased coronary arteries. Non-stenotic lesions may show tiny calcifications surrounded by large areas of irregularly distributed soft tissue. Calcifications in this type of atherosclerotic coronary artery wall changes appear as 'the tip of iceberg'. Heavy calcifications usually tend to be non-stenotic because of vessel remodelling resulting in a widening of the coronary vessel lumen. Therefore, heavy calcifications appear to ack like an 'internal stent' for a coronary vessel segment. Humps of soft tissue either with or without calcifications are more likely to cause significant coronary artery disease and correlate with stenoses of >50% on selective coronary catheter. These humps consist of well-defined soft tissue in the coronary artery wall. The density of this soft tissue may vary between 30-70 HU. In cases where a coronary vessel is occluded by thrombotic material, a typical sign is found with enlargement of the coronary vessel, a hypodense center and a hyperdense rim. Vessel occlusion without thrombus may also appear within a collapsed and dense lumen. In addition to the investigation of the coronary arteries, CTA with MDCT is well suited to assess the presence and morphology of myocardial scars and aneurysms, intracardial tumors and thrombi.

Calcinosis↗

Segmental and subsegmental pulmonary arteries: evaluation with electron-beam versus spiral CT.

PURPOSE: To compare contrast agent-enhanced spiral and electron-beam computed tomography (CT) for the analysis of segmental and subsegmental pulmonary arteries. MATERIALS AND METHODS: CT angiography of the pulmonary arteries was performed in 56 patients to rule out pulmonary embolism. Electron-beam CT was performed in 28 patients. The other 28 patients underwent spiral CT with comparable scanning protocols. The depiction of segmental and subsegmental arteries was analyzed by three independent readers. The contrast enhancement in the main pulmonary artery was measured in each patient. RESULTS: Analysis was performed in 1,120 segmental and 2, 240 subsegmental arteries. One segmental (RA7, P =.010) and two subsegmental (LA7b, P =.029; RA6a+b, P =.038) arteries in paracardiac and basal segments of the lung were depicted significantly better with electron-beam CT. There was no statistically significant difference between electron-beam and spiral CT in the total number of analyzable peripheral arteries depicted. The mean contrast enhancement in the main pulmonary artery was 362 HU in electron-beam CT studies versus 248 HU in spiral CT studies. CONCLUSION: Detailed visualization of peripheral pulmonary arteries is well within the scope of advanced CT techniques. Electron-beam CT has minor advantages in analyzing paracardiac arteries, probably because of reduction of motion artifacts and higher contrast enhancement. Further studies are needed to establish whether electron-beam CT allows a more confident diagnosis of emboli in these vessels.

Adult↗

Cardiac imaging by means of electrocardiographically gated multisection spiral CT: initial experience.

The authors introduce a method for cardiac investigations by using electrocardiographically gated spiral scanning with a four-section computed tomographic system. Three-dimensional images were reconstructed by means of a 250-msec temporal resolution and continuous volume coverage by using a dedicated multisection cardiac volume reconstruction algorithm. Motion-free thin-section volume images were acquired with thin sections and overlapping image increments within a single breath hold. Data segment shifts in time allowed for multiphase imaging.

Calcinosis↗

Pulmonary embolism: comprehensive diagnosis by using electron-beam CT for detection of emboli and assessment of pulmonary blood flow.

PURPOSE: To comprehensively assess thoracic anatomy and pulmonary microcirculation in pulmonary embolism by using computed tomographic (CT) angiography of the pulmonary arteries combined with functional CT imaging of blood flow. MATERIALS AND METHODS: Twenty-two patients suspected of having acute pulmonary embolism underwent contrast material-enhanced thin-section electron-beam CT angiography of the pulmonary arteries. In addition, in each patient, a dynamic multisection blood flow CT study was performed on a 7.6-cm lung volume with electrocardiographic gating. Pulmonary blood flow was calculated, and perfusion parameters were visualized on color-coded maps. The color-coded maps and CT angiograms were independently evaluated, segment by segment, by two readers for perfusion deficits and the presence of clots, respectively. The results were compared. RESULTS: Mean pulmonary blood flow was 0.63 mL/min/mL in the occluded segments versus 2.27 mL/min/mL in the nonoccluded segments (P: =.001). The sensitivity and specificity of perfusion maps for the presence of segmental pulmonary embolism compared with those of CT angiography were 75.4% and 82.3%, respectively, with positive and negative predictive values of 79.6% and 84.7%, respectively. The false-negative findings were caused mainly by partial occlusion of vessels. In eight patients, a substantial alternative or additional pathologic entity was diagnosed. CONCLUSION: By combining CT angiography and dynamic CT imaging, a comprehensive and noninvasive diagnosis of thoracic structure and function is feasible with a single modality.

Acute Disease↗

Helical and single-slice conventional CT versus electron beam CT for the quantification of coronary artery calcification.

OBJECTIVE: We compared electron beam CT with conventional CT to determine the best method for the assessment of the coronary calcium score. We used conventional CT to examine symptomatic and asymptomatic patients suspected of having coronary artery disease. SUBJECTS AND METHODS: One hundred sixty male patients underwent electron beam CT and helical CT with a pitch of 1 (n = 30) and 2 (n = 30) and using a single-slice mode with (n = 50) and without (n = 50) prospective ECG triggering. In another 50 patients, we determined reproducibility for repeated scanning using electron beam CT. For all images, we derived the calcium score according to the Agatston method. We performed regression analysis and determined mean variability. Mean variability was calculated as the ratio of the absolute difference to the mean of the corresponding calcium scores. RESULTS: The correlation coefficients for electron beam CT and all conventional CT modes were very high (range, 0.93-0.98). The mean variability was highest in the helical mode with a pitch of 2 (61.4%) and lowest for the single-slice mode with prospective ECG triggering (25.4%). For repeated electron beam CT, the correlation coefficient and mean variability were 0.99 and 22.1%, respectively. CONCLUSION: ECG-triggered single-slice conventional CT had the best agreement with electron beam CT calcium scores.

Calcinosis↗

[Computed tomography of the abdomen with multidetector-array CT].

BACKGROUND: The advent of multidetector CT (MDCT) constitutes a quantum leap creating a wealth of new opportunities in medical imaging. However, while the basic principles of spiral CT still apply, we are now challenged to rethink our strategies in planning a CT study to take full advantage of the increased capabilities of MDCT. MATERIALS AND METHODS: We report here our preliminary experiences with MDCT for abdominal CT imaging within a 5-month period. During this time, suitable protocols for investigation of the abdomen using MDCT were developed. The capabilities of MDCT allow for tailoring dedicated CT protocols for routine applications as well as for biphasic liver studies and CT angiography of the aorta and abdominal vessels. RESULTS: The speed of MDCT can either be used to reduce the time needed to cover a given volume, or to use narrower beam collimations to increase the resolution of detail along the z-axis and reduce volume averaging. Higher scan speed allows reduction of the amount of contrast material in vascular applications and suppression of motion artifacts. Higher spatial resolution with thinner collimations reduces volume averaging and improves the detection of small hepatic and pancreatic lesions. Detailed analysis of vascular structures and high-quality three-dimensional reformations become feasible. New problems arise from the large amount of data generated by MDCT. CONCLUSIONS: MDCT offers a wealth of new opportunities that help us to come to a fast and accurate diagnosis in suspected abdominal disease. Traditional indications for performing CT are reemphasized and new clinical applications can be exploited.

Abdomen↗