Search PubMed⌕ Search

Biomedical subjects

U Deligonul

Publications and source records attributed to U Deligonul.

103 records · Page 6Linked to original sources

Restenosis after multilesion percutaneous transluminal coronary angioplasty.

Experience and new technical advances have resulted in an increasing number of patients with multivessel coronary disease who can be considered for percutaneous transluminal coronary angioplasty (PTCA). In selected patients with multivessel coronary disease, PTCA is a safe and effective procedure for the immediate relief of anginal symptoms. However, many questions remain regarding the long-term therapeutic benefit of the procedure. Few data are available on the incidence and clinical significance of restenosis after multilesion PTCA. Clearly, there is the potential for a higher rate of restenosis in patients who undergo dilatation of more than 1 lesion. Determination of restenosis rates after multilesion PTCA is important in the definition of expanded indications for this procedure. Because of the variations in definitions of restenosis and in patient selection factors, reported recurrence rates after multilesion PTCA are not easily compared between patient series. After multilesion dilatation the risk of developing at least 1 recurrent lesion ranges from 26% to 53% and appears to be greater than that reported for single lesion PTCA. Multilesion restenosis occurs in 7% to 21% of patients who undergo multilesion PTCA and is frequently observed in patients with recurrent symptoms. "Silent" multilesion restenosis (i.e., multiple lesion restenosis without symptoms) is rare. A higher risk of restenosis at one of several dilatation sites in a patient with extensive coronary disease should not be a deterrent in recommending multilesion PTCA to selected patients with multivessel coronary disease because the procedure provides important symptomatic relief to most. Further, recurrent narrowings are usually amenable to a second dilatation attempt if clinically indicated.

Angioplasty, Balloon↗

Multilesion coronary angioplasty: clinical and angiographic follow-up.

Determination of the restenosis rate after multilesion percutaneous transluminal coronary angioplasty is an important consideration in defining expanded indications for the procedure. Of 209 patients who underwent successful multilesion coronary angioplasty, 55 symptomatic and 74 asymptomatic patients were restudied an average of 7 +/- 4 months after dilation. The restenosis rate was 82% (45 of 55) in the symptomatic patients and 30% (22 of 74) in the asymptomatic patients (p less than 0.001). Only 4% of the asymptomatic patients had restenosis at more than one dilation site. When only patients who developed a restenosis were considered, the restenosis occurred at more than one dilation site in 47% (21 of 45) of the symptomatic group versus 14% (3 of 22) of the asymptomatic group (p less than 0.05). When all recurrent stenoses were examined, the severity of the luminal narrowing was greater than or equal to 70% in 64% (45 of 70) of the stenotic lesions in the symptomatic patients versus 31% (8 of 26) of the stenotic lesions in the asymptomatic patients (p less than 0.05). Proximal left anterior descending coronary artery disease, increased length of the stenotic narrowing, male gender and diabetes were associated with an increased incidence of restenosis by multivariate analysis. Patient-related variables were not predictive of multilesion restenosis. In conclusion, the majority of patients are clinically improved after multilesion coronary angioplasty. Recurrent symptoms after multilesion coronary angioplasty are frequently associated with multilesion restenosis and a more severe degree of restenotic narrowing. Restenosis at more than one dilation site is uncommon in the asymptomatic patient.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Development and experimental application of contact probe catheter for laser angioplasty.

A sapphire contact probe laser catheter was developed to increase the dimensions of tunnels created by laser angioplasty. The device consisted of a round sapphire probe (2.2 mm diameter) attached to an 8F catheter into which a 0.2 mm optical fiber was inserted with a tip maintained at 3 mm from the sapphire. The fiber was connected to a continuous wave neodymium yttrium aluminum garnet (Nd-YAG) laser. A saline perfusate was circulated through the catheter during laser emissions to prevent excessive heating of the fiber tip. The system was used in vitro on 16 sections of atherosclerotic calcified human cadaver aortic walls, using diluted blood as a medium, at powers ranging from 10 to 40 W and exposure times from 1 to 4 seconds. Six craters were created at each energy level. The system was also used on six human cadaver, agar-embedded, obstructed iliac and femoral arteries, using 40 W and 2 second laser emissions. Dimensions of probe-created craters were compared with those obtained using bare fibers. The shape of the probe craters was that of a truncated cone with the entry hole wider than the exit, as opposed to the cylindrical shape created with unmodified bare fibers. At 120 J (seconds X watts), areas of entry and exit probe-formed holes were greater than those created with the bare fibers (6.7 +/- 0.5 and 3.4 +/- 0.6 versus 0.2 +/- 0.01 mm2, respectively, p less than 0.001).(ABSTRACT TRUNCATED AT 250 WORDS)

Angioplasty, Balloon↗

Efficiency and safety of optically modified fiber tips for laser angioplasty.

To evaluate the safety and efficiency of optically modified fiber tips, craters were created in human cadaver atherosclerotic arterial walls using sapphire contact probes and lensed fibers connected to a continuous wave neodymium yttrium aluminum garnet (Nd-YAG) laser. Laser energy was emitted at a constant level of 50 J. The sapphire contact probe catheter consisted of a round 2.2 mm diameter synthetic sapphire attached to an 8F catheter into which a 0.2 mm diameter optical fiber was inserted with the distal tip maintained at 3 mm from the sapphire. The lensed fiber catheter consisted of a 0.2 mm optical fiber at the end of which a 1 mm diameter lens was made. The fiber was inserted into a 5F low profile balloon catheter with the lens maintained 3 mm beyond the catheter tip. During laser emissions the catheter tips were maintained in a stationary position in contact with tissue targets immersed in blood at an angle of 90 degrees. The diameter of holes at the entry and exit of craters, the depth of craters and thermal injury to adjacent tissue (rim of carbonization and vacuolization) were measured with microscopy. The volume of tissue removed was derived from these values. Controlled effect index was determined as the ratio of diameter of holes and the extent of thermal injury. Efficiency was determined as the ratio of volume of tissue removed and the energy required to vaporize tissue.(ABSTRACT TRUNCATED AT 250 WORDS)

Angioplasty, Balloon↗

Immediate and short-term benefit of multilesion coronary angioplasty: influence of degree of revascularization.

The safety and short-term therapeutic benefit of multilesion percutaneous transluminal coronary angioplasty was assessed in 135 patients, 66 of whom had a minimum of 6 months of follow-up study. Primary success, defined as successful dilation of the most critical lesion or all lesions attempted without major in-hospital complications was obtained in 117 (87%) of the 135 patients. Cardiac complications associated with the procedure were uncommon; prolonged angina occurred in 5% and myocardial infarction in 3%; emergency coronary bypass surgery was performed in 4% of the patients. There were no deaths. Complete revascularization was achieved in 46% of the 117 patients with a primary success. Of the 66 patients eligible for 6 month follow-up, 80% had an uncomplicated course and required no further procedures. Clinical improvement by at least one angina functional class was observed in 90% of the patients. Cardiac events such as the need for a second revascularization procedure were significantly more common in patients who had incomplete versus complete revascularization (35 versus 9%; p = 0.018). Repeat coronary angiography performed an average of 5 months after angioplasty revealed restenosis in 18 of 22 symptomatic patients and 3 of 9 asymptomatic patients. Restenosis occurred at the site of a single dilation in 12 patients, at two sites in 8 patients and at three sites in 1 patient. Thus, multilesion coronary angioplasty is an important therapeutic option for selected patients with multivessel disease and can be performed with relatively low risk. Improvement in angina status can be expected even in patients who have incomplete revascularization.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Reduction in left ventricular cavitary attenuation and improvement in posterior myocardial contrast with higher molecular weight intravenous perfluorocarbon-exposed sonicated dextrose albumin microbubbles.

Although intravenous perfluoropropane-exposed sonicated dextrose albumin (C3SDA) produces myocardial contrast, the posterior myocardium cannot be visualized with epicardial or transthoracic imaging because of excessive left ventricular cavitary contrast. We hypothesized that higher molecular weight, less diffusible gases such as perfluoropentane-exposed sonicated dextrose albumin (C5SDA) would produce equivalent anterior myocardial contrast at lower intravenous doses with less cavitary attenuation. To test this hypothesis, we compared the anterior and posterior peak myocardial videointensity after 0.06 ml/kg intravenous injections of C3SDA and 0.015 to 0.030 ml/kg intravenous injections of C5SDA in seven open-chest dogs. The ability of C5SDA to detect posterior myocardial perfusion abnormalities was also tested. Despite the lower dose, intravenous C5SDA produced equivalent anterior myocardial contrast but significantly higher posterior myocardial contrast (2.6 +/- 1.9 units peak myocardial videointensity C5SDA versus 0.6 +/- 0.9 units C3SDA; p < 0.0001) because of less acoustic shadowing. The visual detection of posterior ischemia with intravenous C5SDA was also significantly improved. We conclude that increasing the molecular weight of the perfluorocarbon gas in sonicated dextrose albumin will significantly improve the detection of posterior perfusion abnormalities.

Animals↗

Detection of myocardial perfusion abnormalities during dobutamine and adenosine stress echocardiography with transient myocardial contrast imaging after minute quantities of intravenous perfluorocarbon-exposed sonicated dextrose albumin.

We have recently discovered that if ultrasound transmission is briefly suspended (triggered to just one frame per cardiac cycle) after very small doses of intravenous perfluorocarbon-exposed sonicated dextrose albumin, the myocardial contrast produced is significantly enhanced. The objective of this study was to test whether this technique (termed transient response imaging) could identify myocardial perfusion abnormalities during adenosine and dobutamine stress echocardiography. In 10 open-chest dogs with a significant (> 50%) coronary stenosis determined by quantitative angiography, intravenous perfluorocarbon-exposed sonicated dextrose albumin (0.005 to 0.01 ml/kg) was given at rest during peak dobutamine stress (20 to 30 micrograms/kg/min). Adenosine stress (100 to 140 micrograms/kg/min) was also given in seven of these dogs. The peak myocardial videointensity and spatial extent of contrast defect with transient response imaging (TRI) were compared with conventional 30 Hz frame rates, as well as wall thickening and coronary flow responses. In all 10 dogs there was visually evident myocardial contrast with TRI. In comparison, myocardial contrast was visually evident in only one of these dogs with conventional imaging. The peak myocardial videointensity ration in the stenosed perfusion bed divided by the normally perfused bed when TRI was used decreased in all dogs during dobutamine stress and correlated with minimal coronary lumen diameter (r = 0.70; p = 0.02). Visually evident myocardial contrast defects were detectable in nine of 10 dogs at peak dobutamine stress but only in one of the dogs with conventional imaging. All seven dogs that received adenosine demonstrated contrast defects with TRI, whereas none demonstrated contrast defects with conventional imaging. We conclude that the myocardial contrast produced with transient response imaging can be used to detect functionally significant coronary stenoses.

Adenosine↗

Experience with an emergency resuscitation system.

The need for a portable extracorporeal support system that can be rapidly initiated for various types of cardiopulmonary failure is well known. The authors report on a system consisting of 3/8 inch tubing, a Sci-Med membrane oxygenator, Omnitherm heat exchanger, Biomedicus or Sarns centrifugal pump, portable battery, and oxygen tanks. The system is mounted on a cart for easy mobility and can be primed in 5-10 min. USCI, DLP, or Axiom cannulas can be inserted femorally. Over 30 months, 29 patients, aged 19-78 years, underwent extracorporeal membrane oxygenation (ECMO) support for cardiac arrest during catheterization (10 patients), shock secondary to acute myocardial infarction (MI) (10 patients), elective percutaneous transluminal coronary angioplasty (PTCA) support (four patients), postcardiotomy failure (four patients), and exposure hypothermia (one patient). Adequate support was achieved in all but one patient. Device flows ranged from 0.2 to 6.0 l/min. There were six survivors (elective PTCA support, three patients; cardiac arrest during catheterization, three patients). Complications included bleeding (15 patients), deep venous thrombosis (three patients), and pump failure (one patient). A portable ECMO system has been developed that allows rapid institution of circulatory support.

Angioplasty, Balloon, Coronary↗