[Mammography screening in Germany: how, when and why?].

It is well-known from several large randomized trials that regular mammography screening can reduce breast cancer mortality. While in many countries mammography screening programs have been in existence for quite some time, an organized population-based screening program is only now being implemented in Germany. In this review article, the different elements of a mammography screening program and their effect on the cost-benefit ratio are discussed and the planned German screening program is compared to the international programs.

Breast Neoplasms↗

Near monochromatic X-rays for digital slot-scan mammography: initial findings.

X-ray spectra are composed of a broad bremsspectrum and anode-characteristic emission lines. In mammography typically molybdenum (Mo), rhodium (Rh) or tungsten (W) anodes are used in combination with Mo, Rh or aluminium filters. Only the photons with energies between 17 and 22 keV of the resulting spectrum are suitable for the soft tissue imaging needed for mammography. The aim of this article is to present first results obtained with a monochromator module mounted at the exit of the X-ray tube of a conventional clinical mammography unit. The experimental setup consists of a Siemens Mammomat 300, an X-ray monochromator module and a linear array detector for image acquisition. The technique is similar to the slot-scan technique known from digital mammography. The experimental machine allows to obtain images both with polychromatic and monochromatic X-rays. Initial evaluation of the system was performed by examination of a contrast-detail phantom (CD-MAM-phantom, Nijmegen, The Netherlands). Images done with the new monochromatic technique were compared to images of the phantom done with polychromatic spectra, with film-screen mammography as well as with digital mammography. The new technique with monochromatic slot-scan mammography resulted in correct identification of 93% of the phantom. Digital slot-scan mammography with polychromatic beam resulted in correct identification of 87%, digital full-field mammography in 83% and conventional film-screen mammography in 70% of the phantom. The results suggest that monochromatization has a potential for improving image quality or decreasing dose in X-ray mammography.

Equipment Design↗

[Preoperative MRT of the breast in invasive lobular carcinoma in comparison with invasive ductal carcinoma].

PURPOSE: To evaluate the role of preoperative MRI of the breast in invasive lobular carcinoma (ILC) compared to invasive ductal carcinoma (IDC). MATERIALS AND METHODS: For one year, all patients transferred by the hospital's gynecologic outpatient service for suspicious findings in routine mammography and/or ultrasound (conventional modalities = CM) underwent preoperative MRI of the breast. Retrospective analysis of the histologic findings identified 17 patients with ILC. These were compared with 30 proven IDC patients, chosen by random. The MRI findings of these 2 patient groups were compared with regard to the detection of additional lesions. The average number of additional lesions detected by MRI was compared for significant differences between both groups using the T-test for paired samples. RESULTS: In the 17 patients with ILC, conventional modalities (CM) identified 21malignant lesions whereas MRI detected a total of 30 lesions. At least one additional lesion was detected by MRI in 7 of the 17 patients with ILC. In the 30 patients with IDC, on the other hand, MRI detected an additional lesion in three instances only. In one patient of the ILC group, MRI identified an additional lesion in the contralateral breast that had escaped detection by CM. No additional contralateral lesion was detected by MRI in any of the IDC patients. Benefit of MRI in ILC-Group: The mean numbers of detected malignant lesions differed significantly between diagnosis by MRI and CM in the ILC group (1.77 carcinomas per patient with MRI versus 1.24 with conventional modalities, T-test, p = 0.0078). Benefit of MRI in IDC-Group: although it was possible to find 1.27 carcinomas vs. 1.17 carcinomas per patient in the IDC-Group, this benefit was not statistical significant (T-test, p = 0.0831). CONCLUSION: Preoperative MRI detects multiple additional lesions compared to the ones already known by CM. The higher incidence of multiple lesions in ILC compared to IDC and the difficult diagnosis of ILC in CM might be the reason for the fact that preoperative MRI is particularly useful in patients with ILC.

Breast↗

Use of iodine-based contrast media in digital full-field mammography--initial experience.

AIM: To investigate the use of iodine-based contrast media in digital full-field mammography. METHODS: After performing initial phantom studies, seven patients underwent digital mammography (Senographe 2000D, GE Medical Systems, Milwaukee, USA) using a specially filtered beam before as well as 60, 120, and 180 seconds after injection of 80 ml of iodine contrast medium (Ultravist 370, Schering AG, Germany). The precontrast mammograms were then subtracted from the postcontrast mammograms and the resulting images compared with a contrast-enhanced dynamic MRI study, performed on all women. RESULTS: Contrast medium accumulation within the tumors was visualized with a good quality in all cases. The conditions under which successful contrast-enhanced digital mammography can be performed were determined in phantom studies. CONCLUSIONS: Contrast-enhanced digital mammography has a potential for improving the visualization of breast tumors in mammography using special beam filtering, adjusted x-ray parameters, proper timing, and suitable subtraction software.

Breast Neoplasms↗

[Dose reduction through gridless technique in digital full-field mammography].

PURPOSE: To determine the role of the scatter grid in digital full-field mammography with respect to image quality and dose and to compare the experimental results with initial clinical experience. MATERIALS AND METHODS: A phantom consisting of 205 fields that enclose gold dots of different thickness and size (CD-Mam phantom, Medical Department, Nijmegen, Netherlands) was used for digital full-field mammography with the conventional grid module and a special gridless module. Four different breast thicknesses were simulated using Plexiglas as scatter material. First, the phantom was exposed at the parameter and dose settings automatically selected in each experimental setup (with and without grid). Subsequently, the phantom was exposed at the different simulated breast thicknesses using the gridless module in combination with the parameters automatically selected for the grid module. This was followed by a series of phantom mammograms obtained with the experimental setup reversed. The 16 mammograms were evaluated by 3 readers and the results compared considering breast thickness, radiation dose, and quality. The gridless module was used for preoperative labeling in 16 patients for comparison of mammograms obtained with and without a grid. RESULTS: For the same entrance dose used in routine mammography, digital mammography without grid is superior to digital mammography with grid when performed on simulated thin breasts (Plexiglas less than 3 cm), with no difference found when performed on simulated large breasts. The advantages of gridless mammography are more pronounced at a markedly reduced entrance dose (identical parenchymal dose without and with grid using the dose automatically selected for the gridless module). This tendency is confirmed by the initial clinical comparison. CONCLUSION: Gridless digital full-field mammography has the potential to reduce the dose further, in addition to already known mechanisms of dose reduction. However, the gridless system must be adjusted (markedly higher "switch-off dose" at the detector) to achieve an overall dose reduction since gridless mammography is inferior to grid mammography for identical doses at the detector plane.

Artifacts↗

[Visualization of microcalcifications on mammographies obtained by digital full-field mammography in comparison to conventional film-screen mammography].

PURPOSE: To evaluate the visualization of microcalcifications on mammographies obtained by full-field digital mammography (FFDM) in comparison to conventional film-screen mammography (FSM). MATERIAL AND METHODS: Forty-seven digital and film-screen mammographies depicting histologically proven lesions (27 benign, 20 malignant) were assessed by 4 readers. The images obtained with the different systems were comparable in terms of positioning. Maximum time interval between film-screen mammography and digital mammography was three months. Using a questionnaire, the readers evaluated the number of microcalcifications and their subjective conspicuity for FFDM (Senographe 2000D, GE Medical Systems, Milwaukee, USA) and FSM. A 7-point scale based on the BIRADS classification was used to characterize the calcifications by means of ROC analysis. RESULTS: No statistically significant differences were seen between the two types of mammography among the readers in assessing the number of microcalcifications. The subjective conspicuity of microcalcifications was found to be significantly better for digital mammographies. The diagnosis assigned by the readers did not show significant differences between the two systems. CONCLUSION: Although the subjective conspicuity of microcalcifications was found to be significantly better on digital mammography compared to film-screen mammography, there was no significant advantage of digital mammography resulting from the higher contrast resolution nor a disadvantage in terms of characterization of microcalcifications resulting from the lower spacial resolution. The advantages of digital mammography (e. g. CAD-systems, archiving, dose reduction) can be used without a loss of diagnostic quality.

Breast Diseases↗

[Comparing the visualization of microcalcifications with direct magnification in digital full-field mammography vs. film-screen mammography].

PURPOSE: To evaluate the conspicuity of microcalcifications in magnified mammographic views of preparations obtained with full field digital mammography (FFDM), film-screen mammography (FSM), and the DIMA technique. MATERIAL AND METHODS: Twelve preparations were examined by FFDM and FSM using 1.8 x magnification and DIMA using 7 x magnification. Parameter settings were identical for all three techniques. The number of visible microcalcifications was then determined for each modality by three radiologists. As far as possible, all preparations were X-rayed at 22 kV and 10 mAS. RESULTS: Altogether 9705 calcifications were counted (DIMA: 1609/1542/1534; FFDM: 1020/753/881; FSM: 901/643/822). The total number of microcalcifications identified with the DIMA technique was 4685 as compared to 2654 with FFDM and 2366 with FSM. The calcifications counted with FFDM and FSM thus corresponded to 56.6 % and 50.5 %, respectively, of those identified with DIMA. The differences between the groups were statistically significant (F-Test, p < 0.05). CONCLUSION: Significantly more calcifications are identified when magnified mammographic views of preparations containing microcalcifications are obtained with the DIMA technique compared to FFDM or FSM. FFDM depicts markedly more calcifications than FSM. This means one should increase spatial resolution. Digital mammography offers the potential for improved visualization of microcalcifications with advanced applications.

Breast Neoplasms↗

International investigation of breast MRI: results of a multicentre study (11 sites) concerning diagnostic parameters for contrast-enhanced MRI based on 519 histopathologically correlated lesions.

A multicentre study was undertaken to provide fundamentals for improved standardization and optimized interpretation guidelines of dynamic contrast-enhanced MRI. Only patients scheduled for biopsy of a clinical or imaging abnormality were included. They underwent standardized dynamic MRI on Siemens 1.0 (163 valid lesions > or = 5 mm) or 1.5 T (395 valid lesions > or = 5 mm) using 3D fast low-angle shot (FLASH; 87 s) before and five times after standardized bolus of 0.2 mmol Gd-DTPA/kg. One-Tesla and 1.5 T data were analysed separately using a discriminant analysis. Only histologically correlated lesions entered the statistical evaluation. Histopathology and imaging were correlated in retrospect and in open. The best results were achieved by combining up to five wash-in or wash-out parameters. Different weighting of false-negative vs false-positive calls allowed formulation of a statistically based interpretation scheme yielding optimized rules for the highest possible sensitivity (specificity 30%), for moderate (50%) or high (64-71%) specificity. The sensitivities obtained at the above specificity levels were better at 1.0 T (98, 97, or 96%) than at 1.5 T (96, 93, 86%). Using a widely available standardized MR technique definition of statistically founded interpretation rules is possible. Choice of an optimum interpretation rule may vary with the clinical question. Prospective testing remains necessary. Differences of 1.0 and 1.5 T are not statistically significant but may be due to pulse sequences.

Adult↗

Differentiation between benign and malignant findings on MR-mammography: usefulness of morphological criteria.

The purpose of this study was to evaluate the usefulness of morphological criteria in differentiating between benign and malignant lesions on MR-mammography. Fifty-three women (18-82 years) with 62 lesions scheduled for excisional biopsy underwent dynamic contrast-enhanced MR-mammography using fast 3D Gradient-Echo sequences in coronal orientation (axial orientation in seven patients). Histology revealed 44 malignant and 18 benign lesions. For each lesion, five radiologists evaluated four morphological features: lesion shape, irregularity of contour, homogeneity of contrast enhancement and presence of ring enhancement. For each feature a receiver operating characteristic (ROC) curve was generated with calculation of the area under the curve (AUC). Interobserver variability was evaluated by the kappa-coefficient. The most reliable morphological feature indicating malignancy was an irregular lesion contour with a sensitivity/specificity/AUC of 83%/76%/0.9 followed by inhomogeneous contrast enhancement (85%/42%/0.7) and the presence of ring enhancement (71%/53%/0.64). The average interobserver agreement for the different features ranged between 0.35 and 0.4. Morphological criteria are useful features in MR-mammography for differentiating between benign and malignant lesions. However, due to the relatively high interobserver variability, standardization of terminology is important.

Adolescent↗

[Improved diagnosis through digital mammography with the assistance of computer algorithms].

OBJECTIVE: The aim of this survey was to determine improved diagnostics through digital mammography with assistance of computer algorithms and new investigation techniques. MATERIAL AND METHODS: In general, the presented procedures are practicable with all digital mammography procedures. In our clinic the largest clinical experience exists with the only FDA certified full field mammography device Senograph 2000D (GE Medical Systems). RESULTS: First results from initial studies are shown, which are to evaluate the new procedures. The so-called post processing with visualization of microcalcifications, computer-assisted diagnosis, tomosynthesis, energy subtraction, contrast media in mammography and teleradiology are considered in particular. CONCLUSION: Digital mammography represents a promising procedure, opening new possibilities for improved diagnostic in mammography.

Algorithms↗

Tissue transition projection (TTP) of the intestines.

Tissue transition projection (TTP) represents a three-dimensional reconstruction technique for volumetric image data sets. To demonstrate the principle characteristics of TTP, a simple phantom consisting of two pipes with a simulated, wall-adherent polyp was scanned with spiral CT, and images were reconstructed by means of volume rendering for both opaque surface reconstructions and TTP. Tissue transition projection was used in 7 patients for reconstruction of the small intestine or the colon. Unlike three-dimensional reconstructions with opaque surfaces, TTP enhances surface transitions while suppressing homogeneous areas, allowing delineation of the bowel wall similar to conventional double-contrast studies.

Adenocarcinoma↗

[Initial clinical experiences with digital full-field mammography].

OBJECTIVE: Digital full-field mammography has been used at the Department of Radiology of Charité Medical Center in Berlin since June 1999. This study compares the new digital technique with conventional mammography including a survey of its value in breast imaging and an outline of future prospects. MATERIAL AND METHODS: More than 1,000 of a total of over 5,000 mammographies performed between June 1999 and April 2000 have been obtained using the digital full-field mammography system Senographe 2000D (GE Medical Systems). The digital mammograms were compared with previous conventional films and conventional mammographies performed during the same period (Philips UC Diagnost, Senographe DMRplus). RESULTS: Digital mammographies were equal to conventional ones in all cases and seemed to be superior in detecting microcalcifications in dense glandular tissue. Adequate assessment was possible despite the lower spatial resolution compared to conventional mammography. Additional magnified images were obtained with both techniques for differentiating microcalcifications. CONCLUSIONS: Digital full-field mammography appears to be at least equal to the conventional technique and even superior in some respects. In our experience, the lower spatial resolution of digital mammography has no major disadvantages. The digital system provides new options for electronic storage of mammograms, telemammography, and computer-aided diagnosis.

Breast Neoplasms↗

[Typical and unusual findings in MR mammography].

In recent years, MR mammography has gained increasing importance in breast diagnostics. The main advantage of this technique is its high sensitivity for invasive breast cancer. The two main indications for MR mammography are preoperative staging of breast cancer and the differentiation between postoperative changes and recurrent tumor. In addition, MR mammography is increasingly used for problem solving in cases of questionable clinical, mammographic or sonographic findings. At this it is important to know not only the different manifestations of breast cancer, but also important benign and malignant diagnostic alternatives. Furthermore, it is necessary to be familiar with therapy-related changes. The most important criterion to differentiate between benign and malignant lesions in MR mammography is the extent and temporal course of contrast enhancement. In addition, the lesion morphology and the signal intensity on T2-weighted images can be used to distinguish between different disease entities. The following review article will discuss typical and unusual findings in breast MRI, including rare entities as well as changes after breast conserving therapy and chemotherapy.

Breast↗

[Full-field digital mammography].

Due to the extremely high image quality requirements in mammography, there has for a long time been no adequate digital alternative to conventional film-screen mammography. The longest experience so far exists with digital mammography on the basis of storage phosphor (CR) systems. However, at normal dose this technique has a relatively poor signal-to-noise ratio and has not found general acceptance. Recently three novel systems for digital mammography by the companies Fischer (slot-scan detector), Trex (CCD-array), and GE (amorphous silicon detector) have been introduced and are currently under clinical investigation. The main advantage of digital mammography is the linear relationship between dose and detector signal with the possibility of a tailored optimization of image contrast. Other advantages include digital image storage, telemammography, and computer-assisted diagnosis.

Breast Neoplasms↗

[Intraoperative digital radiography for diagnosis of nonpalpable breast lesions].

PURPOSE: A procedure for performing intraoperative digital radiography of diagnostic breast specimens directly in the operating suite with teleradiologic assessment by a radiologist is presented. The efficiency of this procedure is compared with that of conventional magnification mammography performed in the radiology department. MATERIAL AND METHODS: Thirty-six specimen radiographs obtained by conventional magnification mammography were compared with 38 intraoperative digital magnification radiographs (DIMA Soft P42 prototype, Feinfocus Inc., Garbsen). The radiographs were assessed for lesion conspicuity and time savings for the surgeon, anesthesiologist, and radiologist. RESULTS: The new procedure identified all 38 labeled pathological lesions, and the conventional technique likewise had a detection rate of 100% (36/36). The new technique resulted in considerable time savings for the surgeon and the radiologist. The duration of surgery was shorter and the time interval from removal of the specimen to reporting of the results was reduced from about 23 min to about 13 min. A single radiograph was sufficient for complete visualization of the specimen in all cases. CONCLUSION: Digital intraoperative specimen radiography considerably reduces the time of surgery depending on the local conditions and is highly accurate in locating a suspicious area within the tissue.

Breast Neoplasms↗

PACS: the silent revolution.

More than 15 years ago the idea of a Picture Archiving and Communication System (PACS) and a filmless hospital was created. In a PACS environment images are acquired, read, communicated and stored digitally. After many years of unsuccessful attempts and prototype installations, the necessary hardware components for a successful PACS installation are now readily available. However, software development is still lagging behind. Only very recently, software developers have realized that it is not sufficient for PACS software to store, communicate and display images, but that PACS software should effectively support the radiologist in the task of interpreting and communicating imaging findings through context-dependent default display arrangements, work-flow management, radiological and hospital information systems integration, and computer-assisted diagnosis. This review examines hard- and software requirements for efficient PACS operation, analyses costs and benefits, and discusses future developments.

Cost-Benefit Analysis↗

Experimental study of X-ray mammography in a fluid bath: reduced radiation dose and improved detail resolution.

OBJECTIVE: To determine the effects on x-ray mammography of embedding the breast in a fluid bath. METHODS: A plexiglass phantom in the shape of a compressed breast was x-rayed in air and water with a mammography unit, and the radiation dose was measured by 20 thermoluminescence dosimeters placed in 20 representative positions on the surface of the phantom. Udders from slaughtered sheep as an animal model and phantoms were examined by mammography in identical positions surrounded by air and different fluids. The images were evaluated for detail resolution subjectively (animal model) and objectively (phantom containing quantifiable structures) by 6 and 15 blinded readers, respectively. The readers' results were analyzed and compared for visualization of the objects in air versus fluid. RESULTS: Mammographic examination in the fluid bath reduced the radiation dose and improved detail resolution in the rounded margin of the breast. Also, viewing conditions in the central region were improved as a result of the uniform optical density across the entire film area. CONCLUSIONS: Performing x-ray mammography in a fluid bath has advantages that make the technical realization of this method desirable.

Air↗