Search PubMed⌕ Search

Biomedical subjects

U Baum

Publications and source records attributed to U Baum.

At least 19 recordsLinked to original sources

Evaluation of carotid artery stenosis with multisection CT and MR imaging: influence of imaging modality and postprocessing.

BACKGROUND AND PURPOSE: We prospectively evaluated the influence of different imaging techniques (time-of-flight MR angiography [TOF-MRA], contrast-enhanced MR angiography [CE-MRA], multisection CT angiography [CTA]) and postprocessing methods (maximum intensity projection [MIP], multiplanar reformation [MPR]) on carotid artery stenosis grading. MATERIALS AND METHODS: Fifty patients (34 men, 16 women) with symptomatic stenosis of the internal carotid artery were examined with a 16-section spiral CT and a 1.5T MR unit. Two MRA techniques were applied: 3D-TOF and CE-MRA. MPR was used for postprocessing with all modalities; MIP was used only with MRA. Four readers measured and calculated the percentage diameter stenosis independently according to NASCET criteria. The Wilcoxon test was used to measure interobserver variability, and the Friedman test was used to test the null-hypothesis of equality of the modalities. RESULTS: The hypothesis for global equality was rejected (P < .001). TOF-MRA and CTA assessed with MPR showed the highest concordance (difference, 0.6%; confidence interval [CI], -3.0, 4.3%), and CE-MRA with MIP and CTA showed the lowest concordance in stenosis grading (difference, 7.0%; CI, 3.4, 10.6%). MPR resulted in lower degrees of stenosis than MIP for both MRA sequences, although not statistically significant (CE, -3.0%; CI, -6.6, 0.6%; TOF, -2.2%; CI, -5.8, 1.4%). When only studies with good or excellent image quality were considered, the differences decreased, but the trends remained. CONCLUSION: Stenosis grading is dependent on the examination method and postprocessing technique. CTA and TOF-MRA evaluated with MPR revealed highest concordance.

Aged↗

[On the way to isotopic spatial resolution: technical principles and applications of 16-slice CT].

The broad introduction of multi-slice CT by all major vendors in 1998 was a milestone with regard to extended volume coverage, improved axial resolution and better utilization of the tube output. New clinical applications such as CT-examinations of the heart and the coronary arteries became possible. Despite all promising advances, some limitations remain for 4-slice CT systems. They come close to isotropic resolution, but do not fully reach it in routine clinical applications. Cardiac CT-examinations require careful patient selection. The new generation of multi-slice CT-systems offer simultaneous acquisition of up to 16 sub-millimeter slices and improved temporal resolution for cardiac examinations by means of reduced gantry rotation time (0.4 s). In this overview article we present the basic technical principles and potential applications of 16-slice technology for the example of a 16-slice CT-system (SOMATOM Sensation 16, Siemens AG, Forchheim). We discuss detector design and dose efficiency as well as spiral scan- and reconstruction techniques. At comparable slice thickness, 16-slice CT-systems have a better dose efficiency than 4-slice CT-systems. The cone-beam geometry of the measurement rays requires new reconstruction approaches, an example is the adaptive multiple plane reconstruction, AMPR. First clinical experience indicates that sub-millimeter slice width in combination with reduced gantry rotation-time improves the clinical stability of cardiac examinations and expands the spectrum of patients accessible to cardiac CT. 16-slice CT-systems have the potential to cover even large scan ranges with sub-millimeter slices at considerably reduced examination times, thus approaching the goal of routine isotropic imaging.

Cardiovascular Diseases↗

[Automatic exposure control to reduce the dose in subsecond multislice spiral CT: phantom measurements and clinical results].

PURPOSE: To investigate the potential of dose reduction in multislice spiral CT (MSCT) with automatic exposure control. MATERIALS AND METHODS: The study was performed on a Sensation 4 multislice scanner. This prototype implementation analyzed the distribution of the attenuation along the z-axis in the lateral and sagittal directions of the digital radiogram. Depending on this distribution of the attenuation, the tube current (mA) is defined for every tube rotation. In addition, the tube current was modulated during each tube rotation. First, a three step oval water phantom was measured to evaluate the potential of this method with respect to dose reduction and image quality. In a patient study (n = 26), four different scan regions (shoulder, thorax, abdomen, pelvis) were examined and dose (mAs) and image quality evaluated in comparison to examinations with a standard protocol for these regions in adults and a weight-adjusted standard protocol in children. The image quality was classified in consensus as good, sufficient and poor image quality. RESULTS: By adapting and modulating the tube current, we substantially reduced the variation of noise in one spiral scan and in one scan region of our patient collective. The dose (average mAs) was reduced by 31 % to 66 % in children (mean 44 %) and between 35 % and 64 % in adults (mean 53 %), depending on the scan region. The image quality was substantially improved in regions with high attenuation and did not suffer in low attenuation regions. CONCLUSION: The dose can be reduced substantially by an automatic exposure control including angular tube current modulation with the same or improved image quality.

Abdomen↗

Complete remission with long-term survival in a patient with esophageal carcinoma and a tracheoesophageal fistula after treatment with the AIO regimen and bi-weekly cisplatin.

INTRODUCTION: To date, only few reports are available on patients with esophageal carcinoma containing a tracheoesophageal fistula under chemotherapy. CASE REPORT: A 56-year-old patient presented to the hospital with a stenosing squamous cell carcinoma of the esophagus containing a tracheoesophageal fistula 3 cm above the carina. After placement of a Port-a-Cath and adequate hydration he received weekly 500 mg/m (2) i. v. folinic acid (FA) as a 1 - 2-hour infusion and 2000 mg/m (2) 5-fluorouracil (5-FU) as a 24-hour infusion (24-h inf.) (AIO regimen) with prior application of bi-weekly 50 mg/m (2) i. v. cisplatin. A tracheal Y-Dumont metallic stent was inserted prior to initiating systemic treatment. The patient's alimentation was completely parenteral. After three cycles of chemotherapy (six months) the patient revealed complete remission (CR) with closure of the tracheoesophageal fistula. The tracheal Y-Dumont stent could be removed and the patient had oral alimentation restored. 29 months after initiating treatment he is without evidence of disease. CONCLUSION: Patients with esophageal carcinoma containing a tracheoesophageal fistula might benefit from chemotherapy and should not be generally excluded from systemic treatment.

Antineoplastic Agents↗

[Improvement of the image quality of MSCT of the pelvis with a raw data-based, multidimensional filter].

PURPOSE: To evaluate the potential of raw data-based multidimensional adaptive filtering (MAF) by determining its effects on image noise and image quality in multi-slice spiral CT (MSCT) of the pelvis. MATERIALS AND METHODS: Fifty patients with rectal and bladder cancer were examined with MSCT using a high-resolution protocol. Reconstructions were performed with dedicated reconstruction software and a standard algorithm, both without and with MAF, with four different modification fractions selected from 5 % to 20 %. The noise was measured at six anatomic sites of the pelvis. Image quality and image noise were rated on a 5-point-scale. RESULTS: Modification fractions of 15 % (15 % MAF) and 20 % (20 % MAF) significantly reduced the noise level at all measurement points in comparison with lower modification fractions (p < 0.05). Overall quality of the reconstructed images was rated better with 15 % MAF and 20 % MAF than with other modification fractions (p < 0.05). No further improvement of the image quality was observed by changing from 15 % MAF to 20 % MAF (p > 0.05). 15 % MAF achieved a mean noise reduction of 33 %. All examinations showed an improved visualization of the rectal wall and perirectal lymph nodes. CONCLUSIONS: MAF improves the image quality by reducing the noise level and by removing noise structures. This technique offers new perspectives to radiation dose reduction in CT.

Humans↗

Neoadjuvant treatment with weekly high-dose 5-Fluorouracil as 24-hour infusion, folinic acid and oxaliplatin in patients with primary resectable liver metastases of colorectal cancer.

PURPOSE: To evaluate the efficacy and safety of neoadjuvant treatment comprising weekly high-dose 5-fluorouracil (5-FU) as a 24-hour infusion, folinic acid (FA) and biweekly oxaliplatin (L-OHP), followed by metastatic resection in patients with primarily resectable liver metastases of colorectal cancer (CRC). PATIENTS AND METHODS: 20 patients with primarily resectable liver metastases of CRC were enrolled in a prospective phase II study. On an outpatient basis, the patients received a treatment regimen comprising biweekly 85 mg/m(2) L-OHP in the form of a 2-hour intravenous infusion and 500 mg/m(2) FA as a 1- to 2-hour intravenous infusion, followed by 2,600 mg/m(2 ) 5-FU administered as a 24-hour intravenous infusion once weekly. A single treatment cycle comprised one infusion per week during a period of 6 weeks followed by a 2-week rest. Two cycles were administered, with a third being added when the treatment was well tolerated. Thereafter, curative resection of the liver metastases was attempted, and the patients were followed up. RESULTS: After neoadjuvant therapy, 2 of the original 20 patients showed complete remission (CR; 10%) and 18 patients partial remission (PR; 90%). As the main symptom of toxicity, diarrhea (CTC toxicity grade 3-4) was observed in 6 patients (30%), followed by vomiting in 3 patients (15%). The curative resectability rate was 80% (16 of 20). In 9 of 18 patients (50%) undergoing surgical intervention, mild postoperative complications, mainly wound healing disturbances (n = 5), occurred. No postoperative mortality was observed. Over a median follow-up of 23 months (12-38) 6 of 16 curatively resected patients developed distant metastases and 1 patient a local pelvic recurrence. The 2-year disease-free survival rate was 52% and the 2-year cancer-related survival rate 80%. CONCLUSION: The neoadjuvant treatment with weekly high-dose 5-FU in the form of a 24-hour infusion combined with FA and L-OHP is very effective and well tolerated. Surgical morbidity does not appear to be increased by the neoadjuvant treatment.

Aged↗

[CT and MRI of the petrous bone].

Diseases of the petrous bone should now be diagnosed by means of high-resolution multislice spiral computed tomography (MSCT) and/or magnetic resonance imaging (MRI). The first step in the process of diagnosis, however, must be conventional X-ray photographs (according to Schüller, Mayer, Stenvers) for screening purposes, because of the high cost of the other procedures mentioned. Because of the excellent imaging of bone structures with MSCT, this technique is especially suitable for the diagnosis both of acquired pathologies and of congenital abnormalities of the external auditory meatus, the middle ear and the mastoid, of trauma-induced pathologies of the entire petrous bone, and of osteogenic diseases. MRI is the method of choice for examination of the labyrinthine system, the interior auditory meatus and the cerebellopontine angle because it gives much the best depiction of soft tissue. Sometimes when questions remain unsolved after computed tomography (CT) examination of the middle ear MRI can be applied to complement CT, and it can yield additional information. Lesions affecting the apex of the petrous pyramid should be examined by MRI. High-resolution CT through the bone window and thin-layer MRI are both components of the presurgical diagnosis before cochlear implant (CI) surgery. For postoperative monitoring a conventional transorbital X-ray of the petrous bone is sufficient; CT is indicated only in complicated cases, and MRI is absolutely contraindicated after CI.

Artifacts↗

[Visualization of coronary arteries in CT as assessed by a new 16 slice technology and reduced gantry rotation time: first experiences].

PURPOSE: First evaluation of image quality of a new 16-slice multidetector-row computed tomography (MDCT) for the assessment of coronary artery disease and lesion detection of the coronary arteries. MATERIALS AND METHODS: On a newly developed 16-slice CT scanner (SOMATOM Sensation 16, Siemens, Forchheim, Germany) a calcium score as well as a contrast-enhanced CT angiography (CTA) were performed on 4 patients with retrospective ECG-gating and a gantry rotation time of 420 ms to exclude or follow-up coronary heart disease. CTA was performed after injecting 120 ml contrast media intravenously. After medication with a ss-Blocker, the heart rate was between 55 and 67 bpm. RESULTS: The scan time for calcium score was 12 s, for CTA 18 s (scan range 15 and 12 cm, respectively). Volume score was between 0 and 256.4. In the CT angiography the entire coronary tree could be visualized in all patients up to the very distal subsegmental branches. In two patients a complete occlusion of the RCA and the LAD were depicted, respectively. In one of these patients, a large aneurysm of the left anterior ventricular wall was also delineated. CONCLUSION: Considering our first experiences with the new 16-slice technology, an excellent visualization of the entire coronary tree including the very distal and side branches due to substantially increased spatial resolution seems to be achievable. In these patients the acquired image quality raises the hope for improved, non-invasive cardiac diagnostics. In larger studies, the clinical impact of this new technology needs to be further investigated.

Aged↗

[MR imaging of pancreatic lesions with Mn-DPDP. A histopathologic correlation].

PURPOSE: To examine the diagnostic accuracy of pancreatic lesions using mangafodipir-trisodium (Mn-DPDP) enhanced MR imaging. The imaging results were correlated with the histopathological results. MATERIAL AND METHODS: 40 patients with suspicion of pancreatic carcinoma were examined with MRI before and after i. v. administration of Mn-DPDP (Philips Gyroscan ACS NT 1.5 T, phased array body-coil: TSE T 2 with and without SPIR, TR 2000 ms, TE 120ms; FFE T 1 breathhold, TR 115 ms, TE 4.6 ms; MRCP, TR 6000 ms, TE 1200 ms; Teslascan i. v. 5 micromol Mn/kg; FFE T 1 breathhold SPIR, TR 140 ms, TE 4,6 ms). Two observers evaluated in consensus the number and characteristics of focal pancreatic lesions. The MR findings were correlated with histopathological findings retrospectively. RESULTS: The following lesions were found: adenocarcinoma (19), pancreatitis (8), adenocarcinoma within pancreatitis (3), insulinoma (2), hematoma (1), papillitis stenosans (1), signet ring cell carcinoma (1), metastasis of rectal carcinoma (1), papillary mesothelioma (1). In three patients there was no pathological finding. Mn-DPDP enhanced MRI showed a sensitivity of 100 % and a specificity of 56 %. CONCLUSION: Mn-DPDP enhanced MRI in conjunction with MRCP showed a high sensitivity for the detection of pancreatic lesions. However, the specificity is low, thus recommending Mn-DPDP enhanced MRI only as a complementary imaging method.

Ampulla of Vater↗

[CT-angiography of the carotid artery: First results with a novel 16-slice-spiral-CT scanner].

PURPOSE: To evaluate a novel multislice CT system (16-slice-spiral-CT scanner) for the diagnosis of carotid artery stenosis. MATERIAL AND METHODS: Five patients with symptomatic atherosclerotic disease of the carotid arteries were examined with a 16- slice-spiral-CT scanner. Collimation was 16 x 0.75 mm, table speed 36 mm/s (pitch of 1.5), rotation time 0.5 s, tube current was 160 eff.mAs at 120 kV. 60 ml of contrast material were injected with a power injector followed by a saline flush. The start delay was measured with test bolus method (20 ml CM). Interactive multiplanar reformation (iMPR) and thin slab MIP as well as volume rendering were used for image evaluation and presentation. RESULTS: Scan time was 9 s for a range of 300 mm. This allowed imaging the whole length of the carotid artery (aortic arch to circle of Willis) in a true arterial phase. Pulsation artefacts did not impair the evaluation of the vessels at the level of the aortic arch. Overall image quality of both "source images" and 3D-reconstructions was excellent, due to a reduced voxel size of 0.03 mm (3). Image evaluation and postprocessing (iMPR, MIP) was done within 15 min. iMPR was highly accurate for demonstrating plaque morphology and determining the percentage of the stenosis. CONCLUSION: For the first time, true arterial phase images of the entire carotid artery with high spatial resolution could be acquired using a 16-slice-spiral-CT scanner. This method offers the potential to replace catheter angiography in the evaluation of carotid artery stenosis.

Blood Flow Velocity↗

[Influence of heart rate on image quality and detection of coronary stenoses with multislice spiral CT].

Multi-slice spiral CT (MSCT) permits the detection of coronary stenoses. We investigated the influence of the patient's heart rate (HR) during the scan on stenosis detection and the presence of motion artifacts. In 100 patients MSCT was performed and retrospectively ECG-gated cross-sectional images were reconstructed. 115 of 400 coronary arteries (29%) were unevaluable due to motion artifacts (84/115) or other reasons (31/115). In evaluable arteries, sensitivity was 91% (51/56 high grade stenoses detected), specificity was 89%. With increasing HR, the number of unevaluable arteries increased and overall sensitivity for stenosis detection decreased from 62% (HR < or = 70 bpm) to 33% (HR > 70 bpm). MSCT permits detection of coronary stenoses, but evaluability and accuracy decrease with increasing HR.

Aged↗

Detection of coronary artery stenoses by contrast-enhanced, retrospectively electrocardiographically-gated, multislice spiral computed tomography.

BACKGROUND: Multislice spiral computed tomography (MSCT) with retrospectively ECG-gated image reconstruction permits coronary artery visualization. We investigated the method's ability to identify high-grade coronary artery stenoses and occlusions. METHODS AND RESULTS: A total of 64 consecutive patients were studied by MSCT (4x1 mm cross-sections, 500-ms rotation, table feed 1.5 mm/rotation, intravenous contrast agent, retrospectively ECG-gated image reconstruction). All coronary arteries and side branches with a luminal diameter >/=2.0 mm were assessed concerning evaluability and the presence of high-grade stenoses (>70% diameter stenosis) or occlusions. Results were compared with quantitative coronary angiography. Of 256 coronary arteries (left main, left anterior descending, left circumflex and right coronary artery, including their respective side branches), 174 could be evaluated (68%). In 19 patients (30%), all arteries were evaluable. Artifacts caused by coronary motion were the most frequent reason for unevaluable arteries. Overall, 32 of 58 high-grade stenoses and occlusions were detected by MSCT (58%). In evaluable arteries, 32 of 35 lesions were detected, and the absence of stenosis was correctly identified in 117 of 139 arteries (sensitivity, 91%; specificity, 84%). If analysis was extended to all stenoses with >50% diameter reduction, sensitivity was 85% (40 of 47) and specificity was 76% (96 of 127). CONCLUSIONS: MSCT with retrospective ECG gating permits the detection of coronary artery stenoses with high accuracy if image quality is sufficient, but its clinical use may presently be limited due to degraded image quality in a substantial number of cases, mainly due to rapid coronary motion.

Aged↗

Impact of surgery on survival in palliative patients with metastatic colorectal cancer after first line treatment with weekly 24-hour infusion of high-dose 5-fluorouracil and folinic acid.

BACKGROUND: In palliative first-line treatment of colorectal cancer, the secondary resection of distant metastases after downstaging has constantly gained in importance. The objective of this prospective study was to examine the tumor response rate, the toxicity, the median survival time and the prognostic impact of metastatic resection after downstaging of consecutively enrolled patients with primary nonresectable colorectal cancer treated with once weekly 24-hour (24-h) infusion of high-dose 5-fluorouracil (5-FU) and folinic acid. PATIENTS AND METHODS: Between January 1995 and July 1997, 53 consecutive patients with primary nonresectable metastases were recruited for a prospective phase II study. The patients received in out-patient care 500 mg/m2 folinic acid in the form of a 1-2-hour infusion followed by 2600 mg/m2 5-FU administered as a 24-h infusion once weekly. One treatment cycle comprised six weekly infusions followed by a two week rest. Three cycles were administered, and in the event of complete remission (CR) or partial remission (PR) and good tolerability, a fourth cycle was undertaken. Thereafter, the possibility of performing a curative metastatic resection was investigated. RESULTS: Of the 53 patients treated, 7 showed a CR (13%), 15 patients a PR (28%), 26 patients stable disease (SD) (49%), and 5 patients progressive disease (PD) (10%). As the main symptom of toxicity, diarrhea (CTC grade 3 + 4) was observed in 11 patients (21%), followed by leucocytopenia (CTC grade 3 + 4) in 2 patients (4%), and the hand-foot syndrome in 1 patient (2%). The median survival time was 17 months with a median follow-up of 41 months (range: 28-59 months). In 9 patients (17%), a secondary metastatic resection was considered; in 6 patients (11%) curative resection was performed, and 4 patients (8%) showed no evidence of disease for at least three years. CONCLUSION: In this phase II study, we have been able to show prospectively that, after downstaging by palliative treatment using a weekly 24-h infusion of high-dose 5-FU and folinic acid, secondary curative metastatic resection was technically feasible in 11% of the patients. For some of these patients, long-term survival is therefore possible. Secondary metastatic resection should be carried out in close interdisciplinary cooperation, and should be further investigated in prospective phase III studies.

Aged↗

[Dose reduction in spiral-CT: detection of pulmonary coin lesions with and without anatomically adjusted modulation of tube current].

PURPOSE: To investigate the potential of projection angle-dependent anatomical adaptation of tube current to reduce dose in spiral CT examinations of the thorax without loss in detectability of pulmonary nodules and image quality. PATIENTS AND METHODS: Dose can be reduced for non-circular patient cross-sections without an increase in noise if the tube current is reduced at those angular positions where the patient diameter and, consequently, attenuation are small. The examinations were dose with SOMATOM Plus 4 (Siemens AG). CT projection data were analysed to determine the optimum tube current for each projection angle in real time. We compared image quality, done, and detection rates of pulmonary nodules for thoracic spiral CT examinations with and without online anatomically adapted tube current control in a group of 38 patients. Three radiologists counted all intrapulmonary nodules in consensus separated in three different groups (< 5 mm, 5-10 mm, > 10 mm). Image quality was evaluated in a scale from 1-3 (1 = very good, 2 = good, 3 = worse). RESULTS: On average, the dose was reduced by 21% (15-34%). With a constant tube current, 704 pulmonary nodules were detected, with tube current modulation 707 pulmonary nodules. For three patients we saw more pulmonary nodules (five) with tube current modulation, for two patients we saw less pulmonary nodules (two). In a direct comparison, the missed intrapulmonary nodules were also detected in the respective method. Thus, the detection rate of intrapulmonary nodules was uninfluenced. In general, no deterioration of image quality was observed. CONCLUSION: On average, 21% dose reduction was achieved by an anatomically adapted tube current modulation in spiral CT examinations of the thorax without a loss in detectability of pulmonary nodules and image quality. This method is an important contribution to dose reduction in spiral CT.

Diagnosis, Differential↗

[Neuritis of the optic nerve after vaccinations against hepatitis A, hepatitis B and yellow fever].

BACKGROUND: Vaccinations are preventive measures against serious infections. In relation to the number of vaccinations per year, the incidence of severe complications is extremely low. PATIENT: Two weeks after vaccinations against hepatitis A, hepatitis B and yellow fever in preparation for a trip to Africa a 21-year-old woman experienced an acute and irreversible loss of vision to 0,05 and nasal visual field defect in the left eye. Whereas vision acuity did not recover the scotoma disappeared within 6 weeks. Cerebrospinal fluid showed a lymphocytic pleocytosis. Oligoglonale bands were absent. Pathological parameters were not presented in the serum. The MRI showed a hyperintense thickening of optic nerve,as well as a hyperintense focus in right temporal side using the T(2)W-Sequence. CONCLUSION: Only few cases have been reported with neurological complications, such as encephalitis, following vaccinations each of the above mentioned. As no other causes for the inflammation were found, the optic nerve involvement must have been caused by the vaccination. Which of the three vaccinations caused encephalitis can not be classified.

Adult↗