Prevention of device-related tissue damage during percutaneous deployment of tissue-engineered heart valves.

BACKGROUND: Endovascular application of pulmonary heart valves has been recently introduced clinically. A tissue-engineering approach was pursued to overcome the current limitations of bovine jugular vein valves (degeneration and limited longevity). However, deployment of the delicate tissue-engineered valves resulted in severe tissue damage. Therefore the objective of this study was to prevent tissue damage during the folding and deployment maneuver. MATERIAL AND METHODS: Porcine pulmonary heart valves, small intestinal submucosa, and ovine carotid arteries were obtained from a slaughterhouse. After dissection and antimicrobial incubation, the valves were trimmed (removal of sinus and most of the muscular ring) to fit into the deployment catheter. The inside (in-stent group, n = 6) or outside (out-stent group, n = 6) of a nitinol stent was covered by an acellular small intestinal submucosa, and the valves were sutured into the stent. The valves were folded, tested for placement in the deployment catheter, and decellularized enzymatically. Myofibroblasts were obtained from carotid artery segments and seeded onto the scaffolds. The seeded constructs were placed in a dynamic bioreactor system and cultured for 16 consecutive days. After endothelial cell seeding, the constructs were folded, deployed, and processed for histology and surface electron microscopy. RESULTS: The valves opened and closed competently throughout the entire dynamic culture. Surface electron microscopy revealed an almost completely preserved tissue in the in-stent group. Stents covered with small intestinal submucosa on the outside, however, showed severe damage. CONCLUSION: This study demonstrates that small intestinal submucosa covering of the inside of a pulmonary valved stent can prevent stent strut-related tissue damage.

Animals↗

Deairing of the venous drainage in standard extracorporeal circulation results in a profound reduction of arterial micro bubbles.

OBJECTIVE: Standard extracorporeal circulation (ECC) remains the staple procedure for cardiac surgeons. Despite modern membrane oxygenators and arterial filters micro bubbles are regularly detected in the arterial line. We investigated whether initial deairing of the venous drainage during connection can reduce the quantity and size of micro bubbles on the arterial side. METHODS: 12 patients underwent isolated coronary artery revascularization with conventional ECC using a two-stage venous catheter and an open, passive venous return into a reservoir. In 6 patients (Control) the venous catheter was routinely connected to the venous line, thereby accepting moderate incorporation of air. In another 6 patients (deaired) the catheter was connected avoiding any visible air entrapment. A bubble counter was used to detect the number and size of any micro bubbles in the arterial line of the ECC. The total number of bubbles as well as the number of bubbles of different sizes was assessed directly after initiation of ECC and during the first 60 sec. RESULTS: All patients had an uneventful surgery with a normal postoperative course. In the Control group a considerable number of bubbles of all sizes occurred initially and after 60 sec. In contrast, very few bubbles were detected in the deaired group. CONCLUSION: Incorporated venous air inevitably reaches the arterial side of the ECC. As deairing of the venous line is a simple and effective manoeuvre to significantly reduce the amount of micro bubbles on the arterial side, we recommend and perform routine deairing in all our patients.

Cardiac Surgical Procedures↗

Multiphoton autofluorescence imaging of intratissue elastic fibers.

Multiphoton induced blue/green autofluorescence by near infrared femtosecond laser pulses has been used to selectively image intratissue elastic fibers in native and tissue engineered (TE) viable heart valves without any invasive tissue removal, embedding, fixation, and staining. Elastic fibers could be clearly distinguished from collagenous structures which emit ultraviolet/violet radiation when excited with intense ultrashort pulses due to second harmonic generation. Deep-tissue three-dimensional imaging of elastic fibers with submicron spatial resolution was performed by optical sectioning of heart valves using a multiphoton laser scanning microscope in connection with a tunable 80 MHz femtosecond laser source. The technology was used to diagnose extracellular matrix structures and cell resettlement of TE heart valves prior implantation. This novel non-invasive method opens the general possibility of high-resolution in situ imaging of elastic fibers, collagen structures and intracellular organelles in living intact tissues without staining.

Animals↗

Comparative study of cellular and extracellular matrix composition of native and tissue engineered heart valves.

Tissue engineering of heart valves utilizes biodegradable or metabolizable scaffolds for remodeling by seeded autologous cells. The aim of this study was to determine and compare extracellular matrix (ECM) formations, cellular phenotypes and cell location of native and tissue engineered (TE) valve leaflets. Ovine carotid arteries, ovine and porcine hearts were obtained from slaughterhouses. Cells were isolated from carotid arteries and dissected ovine, porcine and TE leaflets. TE constructs were fabricated from decellularized porcine pulmonary valves, seeded ovine arterial cells and subsequent 16 days dynamic in vitro culture using a pulsatile bioreactor. Native and TE valves were studied by histology (hematoxylin-eosin, resorcin-fuchsin, Movat pentachrome), NIR femtosecond multiphoton laser scanning microscopy and scanning electron microscopy (SEM). Cells of native and TE tissues were identified and localized by immunohistochemistry. Arterial, valvular and re-isolated TE-construct cells were processed for immunocytochemistry and Western blotting. ECM analysis and SEM revealed characteristical and comparable structures in native and TE leaflets. Most cells in native leaflets stained strongly positive for vimentin. Cells positive to alpha-smooth muscle actin (alpha-SMA), myosin and calponin were only found at the ventricular (inflow) side of ovine aortic and porcine pulmonary valve leaflets. Cells from TE constructs had a strong expression of vimentin, alpha-SMA, myosin, calponin and h-caldesmon throughout the entire leaflet. Comparable ECM formation and endothelial cell lining of native and TE leaflets could be demonstrated. However, immunostaining revealed significant differences between valvular cell phenotypes of native and TE leaflets. These results may be essential for further cardiovascular tissue engineering efforts.

Animals↗

Tissue engineering of ovine aortic blood vessel substitutes using applied shear stress and enzymatically derived vascular smooth muscle cells.

Compared to native blood vessels, all clinically available blood vessel substitutes perform suboptimally. Numerous approaches to tissue engineer (TE) blood vessels have been pursued using different scaffold materials, cell types, and culture conditions. Several limitations however remain to be overcome prior to the potential application in the arterial system. This study aimed at tissue engineering viable ovine blood vessels suitable for implantation into the systemic circulation of sheep. In recent studies vascular smooth muscle cells (vSMC) were derived by an explant technique. However, in this study we show that homogenous populations of differentiated vSMC were only obtained by enzymatic dispersion as characterized by immunostaining for specific vSMC marker proteins. In contrast the explant method yielded predominantly less differentiated myofibroblast-like cells. Enzymatically derived vSMC were seeded onto P-4-HB scaffolds and incubated either in a pulsatile flow bioreactor or under static conditions. Dynamically cultured TE blood vessel substitutes showed confluent layered tissue formation and were completely water resistant. They displayed significantly increased ECM synthesis, DNA, and protein content as well as vSMC marker expression. Mechanical properties of bioreactor cultured TE blood vessels approached those of native aorta. In conclusion ovine, aortic blood vessel substitutes were successfully created using enzymatically derived vSMC, bioabsorbable scaffolds, and applied shear stress.

Animals↗

Complete dynamic repopulation of decellularized heart valves by application of defined physical signals-an in vitro study.

OBJECTIVE: Cardiovascular tissue engineering is a novel concept to develop ideal heart valve substitutes. The objective of this study was to use decellularized porcine pulmonary valves, ovine cells and dynamic tissue culture to obtain viable and biomechanically stable constructs, resembling native aortic heart valves. METHODS: Endothelial cells and myofibroblasts were obtained from ovine carotid arteries. Porcine pulmonary valves were decellularized enzymatically, reseeded and cultured using a hydrodynamic bioreactor system over a time period of 9 or 16 days. Controls were grown over an equivalent time period under static conditions. Specimens of each valve were examined biochemically (cell proliferation, DNA, collagen, 4-hydroxyproline, elastin and glycosaminoglycans), histologically (hematoxylin-eosin, Movat-pentachrome and immunostains) and mechanically (radial and circumferential strength). RESULTS: Histology and biochemical assays demonstrated the removal of almost all cells after decellularization with preservation of the extracellular matrix. Recellularization under pulsatile conditions was significantly improved after 9 and 16 days compared to static conditions. Biochemical and mechanical analysis revealed a continuous increase of cell mass, collagen and elastin contents and strength under pulsatile culture conditions compared to significantly lower values in the static controls. CONCLUSION: This study demonstrated the superiority of the hydrodynamic approach of cellular reseeding to replace decellularized porcine heart valves with ovine cells with almost complete preservation of extracellular matrix integrity.

Animals↗

Impact of decellularization of xenogeneic tissue on extracellular matrix integrity for tissue engineering of heart valves.

The multidisciplinary research of tissue engineering utilizes biodegradable or decellularized scaffolds with autologous cell seeding. Objective of this study was to investigate the impact of different decellularization protocols on extracellular matrix integrity of xenogeneic tissue by means of multiphoton femtosecond laser scanning microscopy, biochemical and histological analysis. Pulmonary valves were dissected from porcine hearts and placed in a solution of trypsin-EDTA and incubated at 37 degrees C for either 5, 8, or 24 h, followed by a 24 h PBS washing. Native and decellularized valves were processed for histology, DNA, cell proliferation, matrix proteins and biomechanical testing. Multiphoton NIR laser microscopy has been applied for high-resolution 3D imaging of collagen and elastin. Distinct differences in several ECM components following decellularization time were observed. Total GAG contents decreased in a time-dependent manner, with o-sulfated GAGs being more susceptible to degradation than n-sulfated GAGs. Efficiency of insoluble collagen extraction increased proportionally with decellularization time, suggesting ECM-integrity may be compromised with prolonged incubation. Biomechanical testing revealed a gradual weakening of mechanical strength with increased decellularization time. The enzymatic decellularization process of heart valves revealed a time-dependent loss of cells, ECM components and biomechanical strength. In order to avoid any immune response a thorough decellularization of 24 h remains mandatory.

Animals↗

Efficient and stable retroviral transfection of ovine endothelial cells with green fluorescent protein for cardiovascular tissue engineering.

To determine whether cellular components of tissue-engineered cardiovascular structures are derived from cells harvested and seeded onto an acellular scaffold, or from cells originating from surrounding tissue (e.g., proximal and distal anastomosis), cellular retroviral transfection with green fluorescent protein (GFP) was used. Ovine endothelial cells (ECs) were transfected with a Moloney murine leukemia virus (Mo-MuLV)-based retroviral vector expressing GFP. Transfection was evaluated by fluorescence microscopy and fluorescence-activated cell sorting. The rate of transfection of the primary cells was 33.4% for ECs, 48 hours after transfection. Stable transfection could be observed for at least 25 subsequent passages. Retroviral transfection with GFP enables stable and reliable long-term labeling of ovine ECs. This approach might offer an attractive pathway to study tissue development, with emphasis on distinguishing between cellular components initially seeded onto a construct and those occurring as a result of cell ingrowth from surrounding tissue.

Animals↗

Tissue engineering of heart valves -- current aspects.

Tissue engineering of heart valves is an evolving research field. Driven by the shortcomings of the heart valve substitutes currently available, such as need for anticoagulation, susceptibility to infections, inability to grow and autorepair, the multidisciplinary approach for designing and growing viable heart valves identical to the native heart valves has begun. The following will give an update of the recent developments, current limitations and potential future applications of tissue-engineered heart valves.

Animals↗

Dynamics of extracellular matrix production and turnover in tissue engineered cardiovascular structures.

Appropriate matrix formation, turnover and remodeling in tissue-engineered small diameter vascular conduits are crucial requirements for their long-term patency and function. This complex process requires the deposition and accumulation of extracellular matrix molecules as well as the remodeling of this extracellular matrix (ECM) by matrix metalloproteinases (MMPs) and their endogenous inhibitors (TIMPs). In this study, we have investigated the dynamics of ECM production and the activity of MMPs and TIMPs in long-term tissue-engineered vascular conduits using quantitative ECM analysis, substrate gel electrophoresis, radiometric enzyme assays and Western blot analyses. Over a time period of 169 days in vivo, levels of elastin and proteoglycans/glycosaminoglycans in tissue-engineered constructs came to approximate those of their native tissue counter parts. The kinetics of collagen deposition and remodeling, however, apparently require a much longer time period. Through the use of substrate gel electrophoresis, proteolytic bands whose molecular weight was consistent with their identification as the active form of MMP-2 (approximately 64--66 kDa) were detected in all native and tissue-engineered samples. Additional proteolytic bands migrating at approximately 72 kDa representing the latent form of MMP-2 were detected in tissue-engineered samples at time points from 5 throughout 55 days. Radiometric assays of MMP-1 activity demonstrated no significant differences between the native and tissue-engineered samples. This study determines the dynamics of ECM production and turnover in a long-term tissue-engineered vascular tissue and highlights the importance of ECM remodeling in the development of successful tissue-engineered vascular structures.

Animals↗

Prediction of safe duration of hypothermic circulatory arrest by near-infrared spectroscopy.

OBJECTIVE: Hypothermic circulatory arrest is widely used for adults with aortic arch disease as well as for children with congenital heart disease. At present, no method exists for monitoring safe duration of circulatory arrest. Near-infrared spectroscopy is a new technique for noninvasive monitoring of cerebral oxygenation and energy state. In the current study, the relationship between near-infrared spectroscopy data and neurologic outcome was evaluated in a survival piglet model with hypothermic circulatory arrest. METHODS: Thirty-six piglets (9.36 +/- 0.16 kg) underwent circulatory arrest under varying conditions with continuous monitoring by near-infrared spectroscopy (temperature 15 degrees C or 25 degrees C, hematocrit value 20% or 30%, circulatory arrest time 60, 80, or 100 minutes). Each setting included 3 animals. Neurologic recovery was evaluated daily by neurologic deficit score and overall performance category. Brain was fixed in situ on postoperative day 4 and examined by histologic score. RESULTS: Oxygenated hemoglobin signal declined to a plateau (nadir) during circulatory arrest. Time to nadir was significantly shorter with lower hematocrit value (P <.001) and higher temperature (P <.01). Duration from reaching nadir until reperfusion ("oxygenated hemoglobin signal nadir time") was significantly related to histologic score (r (s) = 0.826), neurologic deficit score (r (s) = 0.717 on postoperative day 1; 0.716 on postoperative day 4), and overall performance category (r (s) = 0.642 on postoperative day 1; 0.702 on postoperative day 4) (P <.001). All animals in which oxygenated hemoglobin signal nadir time was less than 25 minutes were free of behavioral or histologic evidence of brain injury. CONCLUSION: Oxygenated hemoglobin signal nadir time determined by near-infrared spectroscopy monitoring is a useful predictor of safe duration of circulatory arrest. Safe duration of hypothermic circulatory arrest is strongly influenced by perfusate hematocrit value and temperature during circulatory arrest.

Analysis of Variance↗

Cardiovascular physiology during fetal development and implications for tissue engineering.

Shear stress in fluid dynamics has a well-known impact on vascular cell morphology, proliferation, orientation, and the organization and composition of extracellular matrix. There is an increasing interest in the field of tissue engineering to use defined shear stress in bioreactors for tissue conditioning and guided tissue formation. Especially for cardiovascular structures like heart valves or blood vessels, the type and appropriate amount of shear stress needed to improve tissue formation remains speculative. The authors believe that fetal-like conditions may be more optimal for new tissue formation in a bioreactor. The purpose of this review is to delineate parameters of cardiovascular physiology during embryonic and fetal development that may have a potential impact on the design and setting of bioreactors for cardiovascular tissue engineering.

Biomedical Engineering↗

Tissue engineering: current state and prospects.

Organ shortage and suboptimal prosthetic or biological materials for repair or replacement of diseased or destroyed human organs and tissues are the main motivation for increasing research in the emerging field of tissue engineering. No organ or tissue is excluded from this multidisciplinary research field, which aims to provide vital tissues with the abilities to function, grow, repair, and remodel. There are several approaches to tissue engineering, including the use of cells, scaffolds, and the combination of the two. The most common approach is biodegradable or resorbable scaffolds configured to the shape of the new tissue (e.g. a heart valve). This scaffold is seeded with cells, potentially derived from either biopsies or stem cells. The seeded cells proliferate, organize, and produce cellular and extracellular matrix. During this matrix formation, the starter matrix is degraded, resorbed, or metabolized. First clinical trials using skin or cartilage substitutes are currently under way. Both the current state of the field and future prospects are discussed.

Culture Techniques↗

Utility and limitations of near-infrared spectroscopy during cardiopulmonary bypass in a piglet model.

Near-infrared spectroscopy assessment of cytochrome oxygenation could be a valuable technique to monitor cerebral intraneuronal oxygen delivery during cardiopulmonary bypass. However, the validity of the cytochrome signal has been questioned as it could easily be overwhelmed by the Hb signal. Five- to six-week-old control piglets (n = 5) underwent cardiopulmonary bypass at 37 degrees C. Study animals (n = 10) received 100 mg/kg of sodium cyanide to uncouple cytochrome from HB: Hematocrit was then decreased in steps of 5% from 35 to 5% with crystalloid hemodilution. In study piglets, the initiation of cardiopulmonary bypass was associated with oxygenated Hb increasing from 0 to 62.9 +/- 25.6 microM times the differential path-length factor, and oxidized cytochrome a,a3 increasing to 1.9 +/- 1.8 microM times the differential path-length factor. Cyanide caused oxygenated Hb to increase further to 132.3 +/- 48.9 microM times the differential path-length factor, and oxidized cytochrome c decreased to -7.0 +/- 2.6 microM times the differential path-length factor as anticipated, confirming uncoupling of electron transport. However, hemodilution subsequently resulted in linear decreases in oxidized cytochrome a,a3 (F = 8.57, p < 0.001) suggesting important cross-talk between the Hb and cytochrome signals as cytochrome is only intracellular. In control piglets, tissue oxygenation index showed a positive correlation with pump flow (r = 0.986, p = 0.013). The cytochrome signal as presently measured by near-infrared spectroscopy is highly dependent on hematocrit.

Animals↗

Tissue engineering of cardiac valves on the basis of PGA/PLA Co-polymers.

The limitations of currently used heart valve devices are well known. For prosthetic valves they include infection risk and thrombembolic complications; biologic devices have limited durability. Particularly for pediatric cardiac patients the problem of a lack of growth potential remains a serious issue. The multidisciplinary field of tissue engineering potentially offers an attractive pathway to overcome these disadvantages. The basic concept of tissue engineering is to build a new "tissue" from individual cellular components in vitro using a scaffold to provide an architecture upon which the cells can organize and develop into the desired "tissue" prior to implantation. The scaffold provides the biomechanical profile for the replacement tissue until the cells produce their own extracellular matrix. This newly generated matrix would then ultimately provide the structural integrity and biomechanical profile for the newly developed tissue structure. This work focuses on the concept of using a synthetically produced co-polymer (polyglycolic acid/polylactid acid) as the scaffold for the development of a new generation of heart valves.

Biomechanical Phenomena↗

Tissue-engineered valved conduits in the pulmonary circulation.

OBJECTIVE: Bioprosthetic and mechanical valves and valved conduits are unable to grow, repair, or remodel. In an attempt to overcome these shortcomings, we have evaluated the feasibility of creating 3-leaflet, valved, pulmonary conduits from autologous ovine vascular cells and biodegradable polymers with tissue-engineering techniques. METHODS: Endothelial cells and vascular medial cells were harvested from ovine carotid arteries. Composite scaffolds of polyglycolic acid and polyhydroxyoctanoates were formed into a conduit, and 3 leaflets (polyhydroxyoctanoates) were sewn into the conduit. These constructs were seeded with autologous medial cells on 4 consecutive days and coated once with autologous endothelial cells. Thirty-one days (+/-3 days) after cell harvesting, 8 seeded and 1 unseeded control constructs were implanted to replace the pulmonary valve and main pulmonary artery on cardiopulmonary bypass. No postoperative anticoagulation was given. Valve function was assessed by means of echocardiography. The constructs were explanted after 1, 2, 4, 6, 8, 12, 16, and 24 weeks and evaluated macroscopically, histologically, and biochemically. RESULTS: Postoperative echocardiography of the seeded constructs demonstrated no thrombus formation with mild, nonprogressive, valvular regurgitation up to 24 weeks after implantation. Histologic examination showed organized and viable tissue without thrombus. Biochemical assays revealed increasing cellular and extracellular matrix contents. The unseeded construct developed thrombus formation on all 3 leaflets after 4 weeks. CONCLUSION: This experimental study showed that valved conduits constructed from autologous cells and biodegradable matrix can function in the pulmonary circulation. The progressive cellular and extracellular matrix formation indicates that the remodeling of the tissue-engineered structure continues for at least 6 months.

Animals↗

Patch augmentation of the pulmonary artery with bioabsorbable polymers and autologous cell seeding.

OBJECTIVE: In recent years bioabsorbable synthetic or biologic materials have been used to augment the pulmonary artery or the right ventricular outflow tract. However, each of these polymers has one or more shortcomings. None of these patch materials has been seeded with cells. Thus, we have tested a fast-absorbing biopolymer, poly-4-hydroxybutyric acid, with autologous cell seeding for patch augmentation of the pulmonary artery in a juvenile sheep model. METHODS: Vascular cells were isolated from ovine peripheral veins (n = 6). Bioabsorbable porous poly-4-hydroxybutyric acid patches (porosity > 95%) were seeded on 3 consecutive days with a mixed vascular cell suspension (21.3 +/- 1.3 x 10(6) cells). Forty-five (+/- 2) days after the vessel harvest, 1 unseeded and 6 autologously seeded control patches were implanted into the proximal pulmonary artery. The animals received no postoperative anticoagulation. Follow-up was performed with echocardiography after 1 week and before explantation after 1, 7, and 24 weeks (2 animals each) for the seeded control patches and after 20 weeks for the nonseeded control patch. RESULTS: All animals survived the procedure. Postoperative echocardiography of the seeded patches demonstrated a smooth surface without dilatation or stenosis. Macroscopic appearance showed a smooth internal surface with increasing tissue formation. Histology at 169 days demonstrated a near-complete resorption of the polymer and formation of organized and functional tissue. Biochemical assays revealed increasing cellular and extracellular matrix contents. The control patch showed a slight bulging, indicating a beginning dilatation. CONCLUSION: This experiment showed that poly-4-hydroxybutyric acid is a feasible patch material in the pulmonary circulation.

Absorbable Implants↗