Search PubMed⌕ Search

Biomedical subjects

Tyler C Wind

Publications and source records attributed to Tyler C Wind.

12 recordsLinked to original sources

A new method of selecting Schwann cells from adult mouse sciatic nerve.

We describe a method of using laminin for the selection and purification of Schwann cells in vitro. We also studied the viability of the selected cells suspended in alginate beads both in vitro and in vivo. We observed that the homogeneity of the Schwann cell culture increased with each round of laminin selection and reached 85-90% after five passages. The viability of cells after incubation within an alginate bead in vivo was between 73 and 76% compared with greater than 90% viability for cells that were maintained in monolayer culture. This new method of serial selection using laminin-coated surfaces has optimized the purification of a Schwann cell culture expanded from cells harvested from the adult sciatic nerve of a mouse. This method has the advantage of being technically easier than other methods described and results in a Schwann cell culture that is 80-90% homogenous.

Animals↗

Reducing accidental injuries during surgery.

Extensive clinical investigations have demonstrated that double-gloves and blunt-tipped surgical needles dramatically reduced the risk of accidental injuries during surgery. During the last decade, double-glove hole puncture indication systems have been developed that reduce the clinical risk of accidental needlestick injuries as well as detect the presence of glove hole puncture in the presence of fluids. When the outer glove is punctured, the colored underglove becomes apparent through the translucent outer glove, necessitating glove removal, hand washing, and donning of another double-glove hole puncture Indicator system. This article presents the first biomechanical performance study that documents the puncture resistance of blunt surgical needles in latex and nonlatex single gloves and double-glove hole puncture indication systems. The technique for measuring glove puncture resistance simulates the standard test for material resistance to puncture outlined by the American Society for Testing and Materials. The maximum puncture resistance force was measured by the compression load cell and recorded in grams with a strip chart recorder. Ten puncture resistance measurements for the taper point needle, blunt taper point needle, and blunt needle were taken from five samples of the Biogel Indicator underglove, Biogel Super-Sensitive glove, Biogel glove, Biogel Skinsense N Universal underglove, and Biogel Skinsense Polyisoprene glove; and the Biogel, Biogel Super-Sensitive, and Biogel Skinsense Polyisoprene double-glove hole puncture indication systems. The magnitude of puncture resistance forces recorded was influenced by several factors: glove material, number of glove layers, and type of surgical needle. For each type of curved surgical needle,the resistance to needle penetration by the nonlatex gloves was significantly greater than those encountered by the latex glove materials. The resistance to needle puncture of all three double-glove systems was significantly greater than that of either the nonlatex or latex underglove or outer glove. The taper point needle encountered the lowest puncture resistance forces in the five single gloves and the three double-glove systems. Blunting the sharp end of the taper point needle markedly increased its resistance to glove puncture in the five single gloves and five double-glove systems. The blunt-point surgical needle elicited the greatest needle penetration force in all of the single and double-glove systems.

Accidents, Occupational↗

Reliability and performance of innovative surgical double-glove hole puncture indication systems.

During operative procedures, operating room personnel wear sterile surgical gloves designed to protect them and their patients against transmissible infections. The Food and Drug Administration (FDA) has set compliance policy guides for manufacturers of gloves. The FDA allows surgeons' gloves whose leakage defect rates do not exceed 1.5 acceptable quality level (AQL) to be used in operating rooms. The implications of this policy are potentially enormous to operating room personnel and patients. This unacceptable risk to the personnel and patient could be significantly reduced by the use of sterile double surgical gloves. Because double-gloves are also susceptible to needle puncture, a double-glove hole indication system is urgently needed to immediately detect surgical needle glove punctures. This warning would allow surgeons to remove the double-gloves, wash their hands, and then don a sterile set of double-gloves with an indication system. During the last decade, Regent Medical has devised non-latex and latex double-glove hole puncture indication systems. The purpose of this comprehensive study is to detect the accuracy of the non-latex and latex double-glove hole puncture indication systems using five commonly used sterile surgical needles: the taper point surgical needle, tapercut surgical needle, reverse cutting edge surgical needle, taper cardiopoint surgical needle, and spatula surgical needle. After subjecting both the non-latex and latex double-glove hole puncture indication systems to surgical needle puncture in each glove fingertip, these double-glove systems were immersed in a sterile basin of saline, after which the double-gloved hands manipulated surgical instruments. Within two minutes, both the non-latex and latex hole puncture indication systems accurately detected needle punctures in all of the surgical gloves, regardless of the dimensions of the surgical needles. In addition, the size of the color change visualized through the translucent outer glove did not correlate with needle diameter. On the basis of this extensive experimental evaluation, both the non-latex and latex double-glove hole puncture indication systems should be used in all operative procedures by all operating room personnel.

Equipment Design↗

Resistance of double-glove hole puncture indication systems to surgical needle puncture.

Double-gloving has been shown to reduce conclusively the risk of operating room personnel's exposure to blood. Limiting risk of exposure to blood by double-gloving provides protection against the transmission of bloodborne diseases. Realizing the importance of double-gloving, a double-glove hole puncture indication system exists that accurately detects the presence of glove hole puncture in the presence of fluid. Once a glove puncture is recognized by this double-glove hole puncture indication system, it provides a warning to the surgeon to remove the punctured gloves, wash hands, and don a new, sterile double-glove hole puncture indication system. While accurately identifying the presence of glove hole puncture in the presence of fluid, this double-glove hole puncture indication system also has resistance to needle puncture superior to that of single gloves. It is the purpose of this study to document the resistance to needle puncture of latex and non-latex double-glove hole puncture indication systems using a reproducible experimental model. The resistance to needle puncture of the double-glove systems was significantly greater than that of the undergloves or outer gloves alone. The resistance to glove puncture of the non-latex and latex single and double-glove systems was significantly greater than those encountered by the latex single and double-glove systems, respectively. On the basis of their accuracy in detecting glove hole puncture, combined with their demonstrated superior resistance to surgical needle puncture as compared to single gloves, these latex and non-latex double-glove hole puncture indication systems are recommended for all surgical procedures.

Equipment Design↗

Ease of donning of new powder-free non-latex and latex double-glove hole puncture indication systems.

Cornstarch on surgical gloves is often used as a detackifying agent and a lubricant to facilitate glove donning. During the last century, scientific studies have demonstrated that cornstarch produces tissue injury in literally every part of the body. Because this glove lubricant cannot be removed from the glove, Dr. David Podell, an ophthalmologic surgeon, and his cousin, Howard Podell, a chemical engineer, devised the first powder-free surgical glove that could be donned easily. They coated the inner surface of the surgical glove with a methacrylate polymer lining that was bonded to the natural rubber latex. This special coating acts as a lubricant to facilitate donning with damp, wet, or dry hands. In our earlier experimental studies, we confirmed that these polymer-lined latex gloves could be donned with either wet or dry hands. More recently, the polymer-coated latex gloves were incorporated into a double-glove hole puncture indication system that accurately detected glove holes in the presence of fluid. Because this discovery has been expanded into the development of a non-latex double-glove hole puncture indication system, we have expanded our biomechanical performance studies to examine the glove donning forces of the latex and non-latex glove hole puncture indication systems. The maximum donning forces recorded for the non-latex undergloves were significantly lower than those encountered by the same respective sizes of the latex underglove. The donning forces of the thin Biogel Super-Sensitive outer gloves were remarkably similar to the donning forces of the Biogel Indicator undergloves. The thicker Biogel outer gloves encountered greater donning forces than that noted for the Biogel Super-Sensitive outer gloves. The donning forces recorded for the non-latex outer gloves were remarkably similar to those noted for the latex Biogel outer gloves. Because the results of this biomechanical performance study demonstrated that the latex and non-latex double-glove hole puncture indication systems can be easily donned by surgeons using relatively low donning forces, this study provides convincing evidence that these double-glove hole puncture indication systems can be used in all surgical procedures.

Biomechanical Phenomena↗

Creating another barrier to the transmission of bloodborne operative infections with a new glove gauntlet.

While disposable surgical gowns are designed to be either liquid-resistant or liquid-proof apparel, the woven cuffs of surgical gowns are easily permeable to water, an invitation to the transmission of bloodborne infections. Regent Medical has redesigned the diameter of some of its surgical glove gauntlets to enhance the security of the glove/surgical cuff interface. The purpose of this biomechanical performance study was to evaluate the benefit of a narrow glove gauntlet in enhancing the security of the gown and cuff interface. Using three types of disposable gown, the narrow glove gauntlet significantly increased the security of the gown-glove interface. On the basis of this biomechanical performance study, Regent Medical has announced that it will be using this narrow glove gauntlet design on more of their glove products to further reduce the transmission of bloodborne operative infections.

Biomechanical Phenomena↗

Recommendations for postexposure prophylaxis of operating room personnel and patients exposed to bloodborne diseases.

The purpose of this collective review is to discuss management of operating room personnel who have had occupational exposure to blood and other body fluids that might contain hepatitis B virus (HBV), hepatitis C virus (HCV), human immunodeficiency virus (HIV), and human T-cell lymphotropic virus type I (HTLV-I). HBV postexposure prophylaxis includes starting hepatitis B vaccine series in any susceptible unvaccinated operating room personnel who sustain an exposure to blood or body fluid during surgery. Postexposure prophylaxis with hepatitis B immune globulin (HBIG) is an important consideration after determining the hepatitis B antigen status of the patient. Ideally, all operating room personnel should be vaccinated with hepatitis B vaccine before they pursue their career in surgery. Immune globulin and antiviral agents (e.g., interferon with or without ribavirin) should not be used for postexposure prophylaxis of operating room personnel exposed to patients with HCV; rather, follow-up HCV testing should be initiated to determine if infection develops. Postexposure prophylaxis for HIV involves a basic four-week regimen of two drugs (zidovudine and lamivudine; lamivudine and stavudine; or didanosine and stavudine) for most exposures. An expanded regimen that includes a third drug must be considered for HIV exposures that pose an increased risk for transmission. When developing a postexposure prophylaxis regimen, it is helpful to contact the National Clinicians' Postexposure Prophylaxis Hotline (1-888-448-4911).

Blood-Borne Pathogens↗

Functional electrical stimulation for a dropped foot.

The purpose of this collective review is to study the techniques, usage, methods, and clinical results of functional electrical stimulation applied to the peroneal nerve in the treatment of dropped foot. When stimulation is applied through surface electrodes, clinical reports have documented the therapeutic and orthotic benefits of functional electrical stimulation. Clinical trials are now being undertaken in which implantable electrodes are being used to stimulate the peroneal nerve in patients with dropped foot.

Aged↗

Functional electrical stimulation cycle ergometer exercise for spinal cord injured patients.

The purpose of this collective review on functional electrical stimulation (FES) cycle ergometer training is to describe the pathologic effects of spinal cord injury (SCI) and the structure and function of the FES cycle ergometers, which reverse the devastating systemic and life-threatening effects of SCI. The pathophysiologic consequences of SCI include diminished cardiopulmonary and circulatory function as well as lower extremity muscle atrophy and bone mass reduction. Clinical studies have demonstrated that the two FES cycle ergometers offer promise in reversing these devastating consequences of SCI, which can shorten patients' lives. On the basis of this collective review, it is recommended that all patients with SCI have the benefits of this potentially life-sustaining clinical modality.

Cardiovascular Diseases↗

Functional electrical stimulation in tetraplegic patients to restore hand function.

The purpose of this collective review is to describe a new form of functional electrical stimulation called neuroprosthesis. This unique technology has been devised to produce lateral pinch and palmar grasp in persons with C5 and C6 motor level spinal cord injuries. This neuroprosthesis includes external as well as implanted components. First, a receiver is surgically implanted into the patient's chest above a pectoralis major muscle. The receiver stimulator is then connected to 8 surgically implanted epimysial or intramuscular electrodes. Restoration of upper extremity function can greatly improve the lives of people affected with tetraplegia. When contralateral shoulder movements trigger an external transmitting coil, it sends a radio wave impulse to the stimulator inducing contraction of the muscles. Many tetraplegics are regaining hand function using implanted functional electrical stimulation. One major limitation is that the key muscles to be stimulated may have lower motor neuron damage, but this obstacle has been successfully overcome using surgical modifications of the biomechanics of the hand.

Activities of Daily Living↗

Functional electrical stimulation of bladder and bowel in spinal cord injury.

The purpose of this collective review is to examine the use of functional electrical stimulation for incontinence. The Finetech-Brindley bladder system enhances voiding through stimulation via electrodes implanted around the ventral sacral roots. Detrusor hyperreflexia is eliminated through complete dorsal rhizotomy, which results in loss of reflex defecation and reflex erection/reflex lubrication. Consequently, a new system is being devised in which functional electrical stimulation for incontinence in spinal cord injury can be achieved without dorsal rhizotomy.

Electric Stimulation Therapy↗

Functional electrical stimulation for ejaculation.

The purpose of this collective review is to discuss the technique and effectiveness of rectal probe electroejaculation in conjunction with various assistive reproductive modalities. The electroejaculation probe is positioned inside the anal ring with the electrodes placed against the prostate gland and seminal vesicles, after which electrostimulation is begun. Rectal probe electroejaculation must be always employed in a hospital setting to detect and prevent autonomic dysreflexia. This technology is considered the best approach in patients with spinal cord injury levels below T10 or in other patients in which penile vibratory stimulation fails.

Clinical Trials as Topic↗