Search PubMed⌕ Search

Biomedical subjects

Tsuyoshi Matsuda

Publications and source records attributed to Tsuyoshi Matsuda.

At least 19 recordsLinked to original sources

[Optimization of three-dimensional triple IR fast spoiled gradient recalled acquisition in the steady state (FSPGR) to decrease vascular artifact at 3.0 Tesla].

The purpose of this study was to decrease vascular artifacts caused by the in-flow effect in three-dimensional inversion recovery prepared fast spoiled gradient recalled acquisition in the steady state (3D IR FSPGR) at 3.0 Tesla. We developed 3D triple IR (3IR) FSPGR and examined the signal characteristics of the new sequence. We have optimized scan parameters based on simulation, phantom, and in-vivo studies. As a result, optimized parameters (1st TI=600 ms, 3rd TI=500 ms) successfully have produced the vessel signal at more than 40% reduction, while gray-white matter contrast was preserved. Moreover, the reduced artifact was also confirmed by visual inspection of the in-vivo images for which this condition was used. Thus, 3D 3IR FSPGR was a useful sequence for the acquisition of T1-weighted images at 3.0 Tesla.

Adult↗

Direct observation of rectified motion of vortices in a niobium superconductor.

Using Lorentz microscopy to directly image vortices, we investigate vortex motion control and rectification in a niobium superconductor. We directly observe a net motion of vortices along microfabricated channels with a spatially asymmetric potential, even though the vortices were driven by an oscillatory field. By observing the individual motion of vortices, we clarify elementary processes involved in this rectification. To further demonstrate the ability to control the motion of vortices, we created a tiny vortex "racetrack" to monitor the motion of vortices in a closed circuit channel.

Journal Article↗

Optical system for double-biprism electron holography.

A novel system of electron interferometry and holography using two electron biprisms has been developed. The first biprism is installed in the image plane of the objective lens and the second one is set behind the first magnifying lens, inside the shadow area of the first biprism. The system can independently control two important parameters for interferograms and holograms, the fringe spacing and interference width. Thus, it gives us more flexibility on performing electron interferometry and holography. The good performance of the system was demonstrated using a 1MV field-emission electron microscope. We introduce a variety of optical set-ups for the system and explain the advantages of each set-up in detail, with experimental results.

Journal Article↗

Cerebral hyperperfusion in a patient with eclampsia with perfusion-weighted magnetic resonance imaging.

The patient was a 25-year-old Japanese woman with postpartum eclampsia, in whom magnetic resonance imaging (MRI) was performed ten hours after convulsion. The patient improved within three days. Diffusion-weighted images showed a high apparent diffusion coefficient (ADC), and perfusion-weighted images obtained by the multi-slice flow-sensitive alternating inversion recovery (FAIR) method showed hyperperfusion, which was suggestive of vasogenic edema, on the parietal and occipital subcortical white matter, corresponding with transient hyperintensities on T2-weighted images. MR angiography (MRA) revealed no signs of vasospasm. These findings suggested hyperperfusion-induced vasogenic edema without cerebrovascular spastic change in the early stage of eclampsia. The FAIR method is considered a useful technique for perfusion-weighted MRI, especially useful to evaluate the cerebral perfusion of emergency patients such as those with eclampsia.

Adult↗

Assessment of the specific absorption rate and calibration of decoupling parameters for proton decoupled carbon-13 MR spectroscopy at 3.0 T.

A strategy for proton decoupled carbon-13 MR spectroscopy ((1H)-13C MRS) with a strong static magnetic field (3.0 T) in vivo was investigated. The proton decoupling improves the signal-to-noise ratio, however, the effect of the decoupling power on the human body, especially in strong magnetic fields, should be considered. In order to establish a technique for monitoring the metabolism of glucose in the liver using (1H)-13C MRS at 3.0 T, two phantom experiments were performed. To assess whether the decoupling energy conformed to SAR limits defined by the IEC, temperature rises inside an agar gel phantom were monitored during a (1H)-13C MRS experiment. Then, the decoupling conditions of a glucose solution phantom were systematically optimized with combinations of decoupling bandwidth and power. The reliability of this procedure was discussed in conjunction with IEC guidelines.

Absorption↗

Correlation between flow-sensitive alternating inversion recovery perfusion imaging with different inversion times and cerebral flow reserve evaluated by single-photon-emission computed tomography.

The purpose of this study was to evaluate the effect of different inversion times (TIs) on flow-sensitive alternating inversion recovery (FAIR) perfusion imaging and compare them with the cerebral blood flow reserve evaluated by acetazolamide challenge using single-photon-emission computed tomography (SPECT). The subjects were nine patients with unilateral obstruction of the internal carotid artery. The signal ratio (SR16/8) of two images with different TIs (1,600 ms and 800 ms) was calculated, and the cerebral blood flow reserve (CFR) was evaluated by the increase in the ratio of cerebral perfusion after administration of acetazolamide in the SPECT study. A reversed linear correlation ( r=0.75) was found between SR and CFR, indicating that differences of FAIR images with changes of TI will be affected by cerebral flow reserve.

Acetazolamide↗

[Fundamental study of magnetization transfer contrast (MTC) effect: optimization of MT pulse condition using experimental phantom].

Magnetization transfer contrast (MTC) was evaluated by changing the off-set frequency and pulse intensity of MTC with the spoiled gradient echo (SPGR) sequence (T2*-weighted image) using an experimental phantom that included olive oil, protein, fiber, collagen, and pure water. The intensity of pure water reached a constant level just above the off-set frequency (1200 Hz) regardless of MT pulse power. The contrast-to-noise ratio (CNR) in each of the phantom materials was maximal at the MT pulse power of 2500 degrees (equivalent flip angle). The CNR and image noise obtained by body coil were inferior to those obtained with an extremity coil. In clinical application, the MTC effect on chondrosarcoma was higher (MT ratio, ROI-1:0.448, ROI-2:0.382) than those of other cases in this study. Since the image contrast was improved between the malignant fibrous histiocytoma (MFH, MT ratio, ROI-1:0.282, ROI-2:0.289) and peripheral tissues, extraskeletal extension could be observed more easily than without MTC imaging. In conclusion, the effects of MTC might be in providing useful information, in presuming composed tissues, differential diagnoses, and extent to the surrounding structures because of changing the image contrast to surrounding tissues corresponding to the rate of included bound water.

Bone Neoplasms↗

Dynamic T1 estimation of brain tumors using double-echo dynamic MR imaging.

PURPOSE: To assess the clinical utility of a new method for real-time estimation of T1 during the first pass of contrast agent by using this method to examine brain tumors. MATERIALS AND METHODS: The multi-phase spoiled gradient-echo pulse sequence using the double-echo magnetic resonance (MR) technique was modified. In the first half of the pulse sequence, the flip angle was varied systematically. Then, static T1 values were calculated using differences in MR signal intensities between different flip angles. In the latter half of this sequence, changes in absolute T1 were calculated using differences in signal intensities before and after injection of contrast agent. The double-echo MR data were used to minimize the T2* effect. Five cases of neurinoma and seven cases of meningioma were examined. Changes in T1 during the first pass of contrast agent were compared between neurinoma and meningioma. RESULTS: Changes in absolute T1 were clearly demonstrated on the parametric map. Although the changes in absolute T1 during the first pass of contrast agent did not allow differentiation between the two types of tumors, the mean gradient after the first pass was statistically higher for neurinoma than for meningioma (P < 0.05; meningioma, 0.011 +/- 0.012 second(-1)/second; neurinoma, 0.034 +/- 0.020 second(-1)/second). CONCLUSION: The present method appears to be useful for estimation of dynamic T1 changes in brain tumors in clinical settings.

Adult↗

Centrally fat-saturated three-dimensional magnetic resonance angiography of the abdomen using selective central fat-saturation of k-space.

PURPOSE: To assess the usefulness of centrally fat-saturated three-dimensional magnetic resonance (MR) angiography of the abdomen using an elliptical centric view order and selective placement of fat-saturation pulses in the central 30% portion of the k-space in terms of fat signal reduction, image contrast of post-contrast images, and breath-holding time. METHODS: Fat signal in abdomen and breath-holding time were compared between centrally fat-saturated three-dimensional sequence and partially fat-saturated three-dimensional sequence or conventional fat-saturated three-dimensional sequence. Abdominal contrast-enhanced centrally fat-saturated three-dimensional MR angiography was obtained at arterial and equilibrium phases, and image quality was quantitatively and visually evaluated. RESULTS: Centrally fat-saturated three-dimensional sequence suppressed fat signal, as did the conventional fat-saturated three-dimensional sequence, and the breath-hold was prolonged only by 1.5 seconds compared to the partially fat-saturated three-dimensional sequence. Contrast-enhanced centrally fat-saturated three-dimensional MR angiography provided abdominal MR arteriography with large signal difference between vessels and fat, while venous signal was insufficient at equilibrium phase. CONCLUSION: Abdominal contrast-enhanced centrally fat-saturated three-dimensional MR angiography using an elliptical centric view order and selective central fat-saturation of k-space reduced fat signal comparable to conventional fat-saturated three-dimensional sequence, and provided contrast-enhanced MR arteriography with high vascular contrast and minimum prolongation of breath-hold.

Abdomen↗

Comparison of FAIR technique with different inversion times and post contrast dynamic perfusion MRI in chronic occlusive cerebrovascular disease.

The purpose of this study was to examine the signal change occurring with different inversion times (TIs) of the flow-sensitive alternating inversion recovery (FAIR) technique and to compare with the perfusion image obtained with Gd-DTPA injection. The subjects were 11 patients with unilateral occlusive cerebrovascular disease. Two FAIR images with different TIs (800 ms and 1600 ms) were measured for each patient and dynamic perfusion MRI was performed to produce four kinds of parameter maps: mean transit time (MTT), time to peak (TTP), relative cerebral blood flow (rCBF) and relative cerebral blood volume (rCBV) maps. Asymmetry ratios (ARs) between the affected and contra-lateral vascular sides were measured in both FAIR images and the four dynamic parameter maps. The AR of the MTT map of the four parameters showed the highest correlation with that of the FAIR images, especially with that of TI = 1600 ms (r = 0.829), and the AR of the rCBV map revealed the worst correlation with the FAIR images. The AR of the FAIR image with TI = 800 ms was less correlated with that of MTT than that with TI = 1600 ms. These results suggested that the signal intensity of the FAIR image was influenced by flow transition time and the change in TI could be used to select the flow with a different transition time. Our study suggested that a longer TI in the FAIR technique might be more useful than a shorter TI for evaluating chronic occlusive cerebrovascular disease in the clinical setting.

Brain↗

Profile structure of magnetic flux lines in type-II superconductor from a rectangular electron hologram.

Profile magnetic configuration of a quantized flux line and flux-line lattice penetrating a type-II superconductor thin foil, niobium, was observed by electron holography and Lorentz microscopy using a 300 kV field-emission electron microscope. Each single flux line was distributed periodically as lattice structure in the mixed state just below its critical temperature of 8.5 K, while at low temperature of 5 K the flux lines were weakly bound as bundles. In order to observe the flux-line distribution over a wide area, discrete Fourier transform reconstruction in the holography was extended for a rectangular area without loss of information and data precision.

Journal Article↗

[Dynamic contrast-enhanced T(1) measuring MRI using variable flip angle SPGR].

We modified the multi-phase spoiled gradient recalled echo (SPGR) pulse sequence using the double-echo MR technique for estimation of T(1) during the first pass of contrast agent, and examined its precision. In the first half of the pulse sequence, the flip angle was varied systematically to calculate static T(1) values. It was necessary to choose optimal flip angles to minimize the calculation error of static T(1) values. In the latter half of this sequence, changes in absolute T(1) were calculated using differences in signal intensities before and after the injection of contrast agent. The optimal flip angle was 20 degrees for precise conversion to T(1) values under the short TR (33.3 ms) condition. Double echo MR data were used to minimize the T(2)* effect. The present method appears to be useful for quantitative estimation of dynamic contrast-enhanced MRI.

Brain Neoplasms↗

[Study of elliptical centric view ordering technique with spectrally selected inversion recovery pulse (spec-IR pulse)].

Among several techniques for contrast-enhanced MRA, the elliptical centric view ordering method, originally developed at the Mayo Clinic, is a promising one. It has been difficult to apply a fat-suppression prepulse, mainly because the conventional fat suppression method requires a longer acquisition time during sampling of the low-frequency domain in k-space, and it causes severe image distortion due to the great change in longitudinal magnetization derived from fat tissue. We developed a novel method to append fat saturation to the elliptical centric view ordering technique, and assessed the feasibility of its use. Our method is to apply fat-saturation pulses only at selected sampling points when any gradient is applied in the slice-encoding direction. In this way, we achieved efficient suppression of fat-derived signal within a relatively short time, comparable to that of the conventional fat-saturation method, and succeeded in minimizing artifacts.

Artifacts↗

Evaluation of efficacy of an automated single-voxel proton MRS algorithm on a 3T system.

PURPOSE: To evaluate the efficacy of a fully automatic, single-voxel, proton MR spectroscopy algorithm on a 3.0T MR system. METHODS: The PROBE/SVQ algorithm (GE Medical Systems) was evaluated on a General Electric (GE) Signa LX-3T system. Ten normal volunteers (female, 21.1+/-2.0 years old) participated in the study. Nine representative regions of interest were examined, namely, right and left frontal white matter; right and left parietal white matter; right and left basal ganglia; right and left dentate nucleus; and pons. RESULTS: The mean coefficients of variation in all regions for the N-acetyl-aspartate to creatine ratio (NAA/Cr), choline to creatine ratio (Cho/Cr), and choline to N-acetyl-aspartate ratio (Cho/NAA) were 10.2+/-2.4%, 11.4+/-3.2% and 12.6+/-1.4%, respectively. CONCLUSION: A fully automated spectroscopic examination under clinical setting utilizing the PROBE/SVQ algorithm appears to be a reliable method, extending the window of routine clinical assessment of brain metabolism.

Adult↗

Fat-suppressed three-dimensional MR angiography technique with elliptical centric view order and no prolonged breath-holding time.

PURPOSE: To determine the appropriate rate of fat-suppression pulses (using spec IR-spectral selective inversion recovery) for fat-suppressed 3D magnetic resonance angiography (MRA) with an elliptical centric view order. MATERIALS AND METHODS: In abdominal 3D fast spoiled gradient echo (fast SPGR) with an elliptical centric view order, the spec IR pulse rate was changed from zero to one every 15 repetitions (in nine steps) in eight volunteers. In the equilibrium phase, abdominal contrast-enhanced 3D MRA was obtained by 3D fast SPGR using an elliptical centric view order without fat-suppression and with two spec IR, and by fat-suppressed 3D fast SPGR with a sequential-centric view order (efgre3D) in 18 cases. Fat and vascular signals were estimated. RESULTS: Although 3D fast SPGR using an elliptical centric view order with spec IR placed every 15 TR and efgre3D effectively decreased fat signals, these sequences lengthened the breath-hold by 4-6 seconds compared with non-fat-suppressed sequence. 3D fast SPGR using an elliptical centric view order and two spec IR reduced the fat signal by 30% and provided good 3D MR angiography without substantial prolongation of breath-hold. CONCLUSION: Two spec IR can be used for generation of partially fat-suppressed abdominal 3D MRA without prolongation of the breath-hold when performing 3D fast SPGR using an elliptical centric view order.

Abdomen↗

Diffusion-weighted in vivo localized proton MR spectroscopy of human cerebral ischemia and tumor.

The apparent diffusion coefficients (ADCs) of water and brain metabolites were determined by proton MR spectroscopy on a clinical MR scanner for healthy volunteers and for pathological changes in cases of acute cerebral infarction and brain tumor. The ADCs of N-acetyl aspartate (NAA) and creatines in tissue involved in acute infarction were decreased compared to normal control values, while in tumors they showed increased values. Since NAA is a neuronal marker, these findings suggest that neuronal cell viscosity changes according to the pathological status of the tissue. The lactate ADC was significantly larger than the values for other major metabolites in cases of ischemia and tumor, suggesting that lactate is present in a different compartment. These results indicate that metabolite diffusion data can be used to reveal changes in the intracellular environment depending on the pathological status.

Adult↗