Monitoring stiffness changes in lesions after radiofrequency ablation at different temperatures and durations of ablation.

The variations in the stiffness or stiffness contrast of lesions resulting from radiofrequency (RF) ablation of canine liver tissue at different temperatures and for different ablation durations at a specified temperature are analyzed. Tissue stiffness, in general, increases with temperature; however, an anomaly exists around 80 degrees C, where the stiffness of the lesion is lower than that of the lesion ablated at 70 degrees C. On the other hand, the stiffness increases monotonically with the duration of ablation. Plots illustrating the ratio of mean strains in normal canine liver tissue to mean strains in ablated thermal lesions demonstrate the variation in the stiffness contrast of the thermal lesions. The contrast-to-noise ratio (CNRe) of the lesions, which serves as an indicator of the detectability of the lesions under the different experimental imaging conditions described above, is also presented. The results presented in this paper show that the elastographic depiction of stiffer thermal lesions is better, in terms of the CNRe parameter. An important criterion in the elastographic depiction of RF-ablated regions of tissue is the trade-off between ablation temperature and duration of ablation. Tissue necrosis can occur either by ablating tissue to high temperatures for short durations or to lower temperatures for longer durations. In this paper, we attempt to characterize the elastographic depiction of thermal lesions under these different experimental conditions. This paper provides results that may be utilized by practitioners of RF ablation to decide the ablation temperature and duration, on the basis of the strain images of normal liver tissue and ablated thermal lesions discussed in this paper.

Animals↗

Improvements in elastographic contrast-to-noise ratio using spatial-angular compounding.

Spatial-angular compounding is a new technique developed for improving the signal-to-noise ratio (SNR) in elastography. Under this method, elastograms of a region-of-interest (ROI) are obtained from a spatially weighted average of local strain estimated along different insonification angles. In this article, we investigate the improvements in the strain contrast and contrast-to-noise ratio (CNR) of the spatially compounded elastograms. Spatial angular compounding is also applied and evaluated in conjunction with global temporal stretching. Quantitative experimental results obtained using a single-inclusion tissue-mimicking phantom demonstrate that the strain contrast reduces slightly but the CNR improves by around 8 to 13 dB. We also present experimental spatial angular compounding results obtained from an in vitro thermal lesion in canine liver tissue embedded in a gelatin phantom that demonstrate the improved visual characteristics (due to the improved CNR) of the compound elastogram. The experimental results provide guidelines for the practical range of maximum insonification angles and estimates of the optimum angular increment.

Animals↗

Correlation of RF signals during angular compounding.

A theoretical analysis of the correlation between radio-frequency (RF) echo signal data acquired from the same location but at different angles is presented. The accuracy of the theoretical results is verified with computer simulations. Refinements to previous analyses of the correlation of RF signals originating from the same spatial location at different angular positions are made. We extend the analysis to study correlation of RF signals coming from different spatial locations and eventually correlation of RF signal segments that intersect at the same spatial location. The theory predicts a faster decorrelation with a change in the insonification angle for longer RF echo signal segments. As the RF signal segment becomes shorter, the decorrelation rate with angle is slower and approaches the limit corresponding to the correlation of RF signals originating from the same spatial location. Theoretical results provide a clear understanding of angular compounding techniques used to improve the signal-to-noise ratio in ultrasonic parametric imaging and in elastography.

Algorithms↗

Viscoelastic characterization of in vitro canine tissue.

Mechanical properties of biological tissues are of interest for assessing the performance of elastographic methods that evaluate the stiffness characteristics of tissue. The mechanical properties of interest include the frequency-dependent complex moduli, storage and loss moduli of tissues. Determination of the mechanical properties of biological tissues is often limited by proper geometry of the sample, as well as homogeneity of the stress-strain relationship. Measurements were performed on in vitro canine liver tissue specimens, over a frequency range from 0.1 to 400 Hz. Tests were conducted using an EnduraTEC ELF 3200, a dynamic testing system for determining the mechanical properties of materials. Both normal tissues and thermal lesions prepared by radio frequency ablation were tested. Experiments were conducted by uniaxially compressing tissue samples using Plexiglas platens larger than the specimens and measuring the load response. The resulting moduli spectra were then fit to a modified Kelvin-Voigt model, called the Kelvin-Voigt fractional derivative model. The data agree well with the model and in comparing the results from the normal tissue with that of the thermal lesions, the concept of a complex modulus contrast is introduced and its applications to elastography are discussed.

Animals↗

Wavelet denoising of displacement estimates in elastography.

Wavelet shrinkage denoising of the displacement estimates to reduce noise artefacts, especially at high overlaps in elastography, is presented in this paper. Correlated errors in the displacement estimates increase dramatically with an increase in the overlap between the data segments. These increased correlated errors (due to the increased correlation or similarity between consecutive displacement estimates) generate the so-called "worm" artefact in elastography. However, increases in overlap on the order of 90% or higher are essential to improve axial resolution in elastography. The use of wavelet denoising significantly reduces errors in the displacement estimates, thereby reducing the worm artefacts, without compromising on edge (high-frequency or detail) information in the elastogram. Wavelet denoising is a term used to characterize noise rejection by thresholding the wavelet coefficients. Worm artefacts can also be reduced using a low-pass filter; however, low-pass filtering of the displacement estimates does not preserve local information such as abrupt change in slopes, causing the smoothing of edges in the elastograms. Simulation results using the analytic 2-D model of a single inclusion phantom illustrate that wavelet denoising produces elastograms with the closest correspondence to the ideal mechanical strain image. Wavelet denoising applied to experimental data obtained from an in vitro thermal lesion phantom generated using radiofrequency (RF) ablation also illustrates the improvement in the elastogram noise characteristics.

Algorithms↗

Elastographic versus x-ray CT imaging of radio frequency ablation coagulations: an in vitro study.

Techniques to image elasticity parameters (i.e., elastography) have recently become of great interest to researchers. In this paper we use conventional ultrasound elastography and x-ray CT to image radio frequency (RF) ablation sites of excised canine liver enclosed in gelatin. Thermal coagulations of different sizes were produced by applying the RF procedure for various times and end point temperatures. Dimensions, areas and volumes computed from CT and elastography were compared with those on whole mount pathology specimens. Ultrasound elastography exhibited high contrast for the thermal coagulations and performed better than CT. The correlation between pathology and elastography for this sample set of 40 thermal coagulations (r = 0.94 for volume estimation, r = 0.87 for area estimation) is better than the correlation between pathology and CT (r = 0.89 for volume estimation, r = 0.82 for area estimation).

Animals↗

Correlation of ultrasonic scatterer size estimates for the statistical analysis and optimization of angular compounding.

Ultrasonic scatterer size estimates generally have large variances due to the inherent noise of spectral estimates used to calculate size. Compounding partially correlated size estimates associated with the same tissue, but produced with data acquired from different angles of incidence, is an effective way to reduce the variance without making dramatic sacrifices in spatial resolution. This work derives theoretical approximations for the correlation between these size estimates, and the coherence between their associated spectral estimates, as functions of ultrasonic system parameters. A Gaussian spatial autocorrelation function is assumed to adequately model scatterer shape. Both approximations compare favorably with simulation results, which consider validation near the focus. Utilization of the correlation/coherence expressions for statistical analysis and optimization is discussed. Approximations, such as the invariance of phase and amplitude terms with angle, are made to obtain closed-form solutions to the derived spectral coherence near the focus and permit analytical optimization analysis. Results indicate that recommended parameter adjustments for performance improvement generally depend upon whether, for the system under consideration, the primary source of change in total coherence with rotation is phase term variation due to the change in the relative position of scattering sites, or field amplitude term variation due to beam movement.

Analysis of Variance↗

Elastographic imaging of thermal lesions in liver in-vivo using diaphragmatic stimuli.

Radiofrequency or microwave ablations are interstitial focal ablative therapies that can be used in a percutaneous fashion for treating tumors in the liver, kidney, and prostate. These modalities provide in situ destruction of tumors. We present a method for in-vivo elastographic visualization of the ablated regions in the liver during and after thermal therapy. In-vivo elastographic imaging uses compressions of the liver due to movement of the diaphragm during the respiratory cycle. Elastography of the liver and other abdominal organs has not been attempted previously due to the difficulty in providing controlled compressions. Gating of the data acquisition to the respiratory waveform would provide access to data where the compression increments are similar in both magnitude and direction, thereby enabling reproducible imaging of the thermal lesion or tumor. Comparison of elastograms with gross-pathology of ablated tissue illustrates the correspondence between elastographic image features and pathology. Ultrasound is routinely used to guide the rf ablation procedure, so the same imaging system could be used for elastographic imaging. Since the technique utilizes physiological motion of the diaphragm due to respiration, it may also be employed in the visualization of cancerous tumors in the liver.

Animals↗

Adaptive spectral strain estimators for elastography.

In conventional elastography, internal tissue deformations, induced by external compression applied to the tissue surface, are estimated by cross-correlation analysis of echo signals obtained before and after compression. Conventionally, strains are estimated by computing the gradient of estimated displacement. However, gradient-based algorithms are highly susceptible to noise and decorrelation, which could limit their utility. We previously developed strain estimators based on a frequency-domain (spectral) formulation that were shown to be more robust but less precise compared to conventional strain estimators, In this paper, we introduce a novel spectral strain estimator that estimates local strain by maximizing the correlation between the spectra of pre- and postcompression echo signals using iterative frequency-scaling of the latter; we also discuss a variation of this algorithm that may be computationally more efficient but less precise. The adaptive spectral strain estimator combines the advantages of time- and frequency-domain methods and has outperformed conventional estimators in experiments and 2-D finite-element simulations.

Algorithms↗

Impact of gas bubbles generated during interstitial ablation on elastographic depiction of in vitro thermal lesions.

OBJECTIVE: Artifacts from gas bubble formation during radio frequency ablation along with the poor intrinsic contrast between normal and treated regions (zone of necrosis) are considerable problems for the visualization of the necrotic region on conventional sonography. Sonographic elastography is very effective for visualizing the zone of necrosis, but it uses the same echo signals to estimate strain as those used to form gray scale images. Thus, the impact of gas bubbles on strain images or elastograms must be investigated. METHODS: Radio frequency ablation was performed in vitro on liver tissue samples, approximately 40 x 40 x 20 mm, encased in 80-mm cubed gelatin phantoms. Elastograms generated at different instants during the ablation procedures were obtained on a real-time scanner with a 5-MHz linear array. Sequences of elastograms illustrate the growth of the thermal lesion. RESULTS: Degradation of the distal boundary of the thermal lesion was observed. The degradation was confined to the lower-fifth quadrant of the thermal lesion. However, accurate estimates of lesion areas could still be obtained by extrapolation of the thermal lesion boundary. CONCLUSIONS: Elastograms of thermal lesions in vitro can be obtained during radio frequency ablation. Some loss of thermal lesion boundary information on strain images was observed in regions where attenuation due to gas bubbles reduced the signal-noise ratio of the echo signals.

Animals↗

Noise reduction using spatial-angular compounding for elastography.

Ultrasound elastography has developed into an imaging modality suitable for detection and diagnosis of cancers in the breast, prostate, and thyroid and for monitoring ablative therapies in the liver, kidneys, and other sites. In this article, a new approach is described that enables the reduction of noise artifacts in elastography without a significant reduction in either the contrast or spatial resolution. The technique uses angular-weighted compounding of local angular strains estimated from echo signals scanned at different insonification angles. Strain estimated along angular insonification directions can be separated into strain tensor components along the axial (direction of compression) and lateral directions. The mechanical stimulus is applied only along one direction. Angular-weighting factors are derived from the relationship between the axial and lateral strains under the assumption of tissue incompressibility. Experimental results using a uniformly elastic, tissue-mimicking phantom demonstrate the improvement in the signal-to-noise ratio obtained with angular-weighted compounding. Variation in the signal-to-noise ratio obtained using different angular increments also is investigated. Elastograms obtained from an inclusion phantom also demonstrate the improvement in contrast detail resolution obtained using spatial-angular compounding.

Algorithms↗

Improved parametric imaging of scatterer size estimates using angular compounding.

The feasibility of estimating and imaging scatterer size using backscattered ultrasound signals and spectral analysis techniques was demonstrated previously. In many cases, size estimation, although computationally intensive, has proven to be useful for monitoring, diagnosing, and studying disease. However, a difficulty that is encountered in imaging scatterer size is the large estimator variance caused by statistical fluctuations in echo signals from random media. This paper presents an approach for reducing these statistical uncertainties. Multiple scatterer size estimates are generated for each image pixel using data acquired from several different directions. These estimates are subsequently compounded to yield a single estimate that has a reduced variance. In this feasibility study, compounding was achieved by translating a sectored-array transducer in a direction parallel to the acquired image plane. Angular compounding improved the signal-to-noise ratio (SNR) in scatterer size images. The improvement is proportional to the square root of the effective number of statistically independent views available for each image pixel.

Algorithms↗

Statistics of ultrasonic scatterer size estimation with a reference phantom.

A theoretical expression for the variance of scatterer size estimates is derived for a modified least squares size estimator used in conjunction with a reference phantom method for backscatter coefficient measurement. A Gaussian spatial autocorrelation function is assumed. Simulations and phantom experiments were performed to verify the results for backscatter and size variances. The dependence of size estimate errors upon free experimental parameters is explored. Implications of the findings for the optimization of scatterer size estimation are discussed. The utility of scatterer size parametric imaging is examined through the signal to noise ratio comparison with standard ultrasonic B-mode imaging.

Analysis of Variance↗

Ultrasonic imaging of myocardial strain using cardiac elastography.

Clinical assessment of myocardial ischemia based on visually-assessed wall motion scoring from echocardiography is semiquantitative, operator dependent, and heavily weighted by operator experience and expertise. Cardiac motion estimation methods such as tissue Doppler imaging, used to assess myocardial muscle velocity, provides quantitative parameters such as the strain-rate and strain derived from Doppler velocity. However, tissue Doppler imaging does not differentiate between active contraction and simple rotation or translation of the heart wall, nor does it differentiate tethering (passively following) tissue from active contraction. In this paper, we present a strain imaging modality called cardiac elastography that provides two-dimensional strain information. A method for obtaining and displaying both directional and magnitude cardiac elastograms and displaying strain over the entire cross-section of the heart is described. Elastograms from a patient with coronary artery disease are compared with those from a healthy volunteer. Though observational, the differences suggest that cardiac elastography may be a useful tool for assessment of myocardial function. The method is two-dimensional, real time and avoids the disadvantage of observer-dependent judgment of myocardial contraction and relaxation estimated from conventional echocardiography.

Aged↗

Ultrasound attenuation imaging using compound acquisition and processing.

A method that combines both spatial and frequency compounding is described for measuring attenuation in tissue. The technique applies a reference phantom to account for imaging system dependencies of echo signals. Emphasis is given to local attenuation estimates, to reduce the variance of the attenuation measurements over small regions of interest (ROI) and to enable coarse attenuation imaging. Experiments using a uniform phantom show that the standard deviation of local attenuation estimates within a ROI drops when greater degrees of compounding are applied. Attenuation images of a specially designed phantom containing inclusions with attenuation contrast illustrate the accuracy and precision of the technique.

Phantoms, Imaging↗

Elastographic measurement of the area and volume of thermal lesions resulting from radiofrequency ablation: pathologic correlation.

OBJECTIVE: Elastography is a promising tool for visualizing the zone of necrosis in liver tissue resulting from radiofrequency tumor ablation. Because heat-ablated tissues are stiffer than normal untreated tissue, elastography may prove useful for following up patients who undergo radiofrequency ablative therapy. We sought to report the initial evaluations of the reliability of elastography for delineating thermal lesion boundaries in liver tissue by comparing lesion dimensions determined by elastography with the findings at whole-mount pathology. MATERIALS AND METHODS: Radiofrequency ablation was performed in vitro on liver tissue specimens encased in gelatin phantoms. The imaging plane for elastography was perpendicular to the axis of the radiofrequency electrode so that the ablated region was around the center of the plane. To obtain three-dimensional visualization of thermal lesions, we reconstructed the lesions from multiple elastograms by linearly translating the elastographic scanning plane. Pathology photographs were obtained in the same image plane used for elastography by slicing through the gelatin and tissue phantom using external markers. We used digitized gross pathology photographs obtained at a specified slice thickness to compute the areas and volumes of the lesions. These measurements were then compared to the measurements obtained from the elastograms. RESULTS: In a sample of 40 thermal lesions, we obtained a correlation between in vitro elastographic and pathologic measurements of r = 0.9371 (p < 0.00001) for area estimates and r = 0.979 (p < 0.00001) for volume estimates. CONCLUSION: We found excellent correlation between the measurements of the dimensions, areas, and volumes of thermal lesions that were based on elastographic images and the measurements that were based on digitized pathologic images. When compared with digitized pathologic measurements, elastographic measurements showed a tendency to slightly underestimate both the areas and volumes of lesions. Nevertheless, elastography is a reliable technique for delineating thermal lesions resulting from radiofrequency ablation.

Animals↗