Oxidized titanium screws coated with calcium ions and their performance in rabbit bone.

PURPOSE: The aim was to answer a fundamental question: Do the chemical properties of titanium implants influence osseointegration? MATERIALS AND METHODS: Screw-type implants produced of turned commercially pure (grade 1) titanium (controls) and electrochemically calcium-deposited titanium implants (Ca test implants) were placed in the tibiae and femora of a total of 10 mature New Zealand white rabbits. The macro arc oxidation method was applied for Ca implants. Surface oxides were characterized with different analytic techniques, including x-ray photoelectron spectroscopy, auger electron spectroscopy, scanning electron microscopy, thin-film x-ray diffractometry, and TopScan 3D. The bone response was evaluated by biomechanical tests, histology, and histomorphometry. RESULTS: After a follow-up period of 6 weeks, test Ca implants showed a significant increase in mean peak removal torque (P = .0001) and in the histomorphometric measurement of bone-to-metal contact around the implants (P = .028) in comparison to controls. In addition, more mature mineralized bone was observed adjacent to test Ca implants compared to controls, as evaluated on 10-microm undecalcified, toluidine blue-stained, cut, and ground sections. DISCUSSION: The potential role of surface Ca chemistry to a superior bone response is discussed with specific reference to interaction with Ca(+)-binding proteins and function as binding sites of calcium phosphate mineral. CONCLUSION: The present results suggest that the surface chemical composition of titanium implants is of great importance for the bone response. Ca ion-deposited titanium implants showed fast and strong osseointegration in the rabbit bone model.

Animals↗

Oral implant surfaces: Part 1--review focusing on topographic and chemical properties of different surfaces and in vivo responses to them.

PURPOSE: This article reviews the topographic and chemical properties of different oral implant surfaces and in vivo responses to them. MATERIALS AND METHODS: The article considers detailed mechanical, topographic, and physical characteristics of implant surfaces. Anchorage mechanisms such as biomechanical and biochemical bonding are examined. Osteoattraction and doped surfaces are discussed. RESULTS: Surface quality of an oral implant may be subdivided into mechanical, topographic, and physicochemical properties. Topographic properties are evaluated at the micrometer level of resolution. Moderately rough surfaces (Sa between 1.0 and 2.0 microm) show stronger bone responses than smoother or rougher surfaces. The majority of currently marketed implants are moderately rough. Oral implants permit bone ingrowth into minor surface irregularities-biomechanical bonding or osseointegration. Additional biochemical bonding seems possible with certain surfaces. Osteoattraction is a commercial term without precise biologic correspondence. Surfaces doped with biochemical agents such as bone growth factors have been developed. CONCLUSION: Moderately roughened surfaces seem to have some clinical advantages over smoother or rougher surfaces, but the differences are small and often not statistically significant. Bioactive implants may offer some promise.

Calcium Phosphates↗

Oral implant surfaces: Part 2--review focusing on clinical knowledge of different surfaces.

PURPOSE: This article reviews clinical knowledge of selected oral implant surfaces. MATERIALS AND METHODS: The surfaces most commonly used in clinical practice, marketed by the five largest oral implant companies, are identified; their clinical documentation was scrutinized following a strict protocol. Experimental knowledge of the surfaces is briefly summarized. Retrospective, prospective, and comparative clinical studies were analyzed separately, as were studies of implants in conjunction with bone grafts. RESULTS: TiUnite anodized surfaces are clinically documented in 1- to 2-year follow-up studies at best, with failures at about 3%. Sandblasted and acid-etched SLA surfaces are documented with good clinical results for up to 3 years. Osseotite dual acid-etched implants are documented with good clinical results for up to 5 years. Frialit-2 sandblasted and etched implants are positively documented for about 3 years in one study only. The Tioblast implant is the only design documented for survival over 10 years of follow-up and success over 7 years of follow-up. CONCLUSION: Generally, oral implants are introduced clinically without adequate clinical documentation. Implant companies initiate clinical documentation after product launch. The standards of clinical reporting have improved over the years. Proper long-term reports have been published for only one surface, Tioblast.

Bone Transplantation↗

Optimum surface properties of oxidized implants for reinforcement of osseointegration: surface chemistry, oxide thickness, porosity, roughness, and crystal structure.

PURPOSE: To investigate detailed surface characterization of oxidized implants in a newly invented electrolyte system and to determine optimal surface oxide properties to enhance the bone response in rabbits. MATERIALS AND METHODS: A total of 100 screw-type titanium implants were prepared and divided into 1 control group (machine-turned implants) and 4 test groups (magnesium ion-incorporated oxidized implants). Forty implants were used for surface analyses. A total of 60 implants, 12 implants from each group, were placed in the tibiae of 10 New Zealand white rabbits and measured with a removal torque test after a healing period of 6 weeks. RESULTS: For the test groups, the oxide thicknesses ranged from about 1,000 to 5,800 nm; for the control group, mean oxide thickness was about 17 nm. The surface morphology showed porous structures for test groups and nonporous barrier film for the control group. Pore diameter ranged from < or = 0.5 microm to < or = 3.0 microm. In regard to surface roughness, arithmetic average height deviation (Sa) values varied from 0.68 to 0.98 microm for test implants and 0.55 microm for control implants; developed surface ratio (Sdr) values ranged from 10.6% to 46% for the test groups and were about 10.6% for the control group. A mixture of anatase and rutile-type crystals were observed in the test groups; amorphous-type crystals were observed in the control group. After a healing period of 6 weeks, removal torque measurements in all 4 test groups demonstrated significantly greater implant integration as compared to machine-turned control implants (P < or = .033). DISCUSSION: Determinant oxide properties of oxidized implants are discussed in association with bone responses. Of all surface properties, RTVs were linearly increased as relative atomic concentrations of magnesium ion increase. CONCLUSIONS: Surface properties of the oxidized implants in the present study, especially surface chemistry, influenced bone responses. The surface chemistry of the optimal oxidized implant should be composed of approximately 9% magnesium at relative atomic concentration in titanium oxide matrix and have an oxide thickness of approximately 1,000 to 5,000 nm, a porosity of about 24%, and a surface roughness of about 0.8 microm in Sa and 27% to 46% in Sdr; its oxide crystal structure should be a mixture of anatase- and rutile-phase crystals.

Animals↗

Which surface properties enhance bone response to implants? Comparison of oxidized magnesium, TiUnite, and Osseotite implant surfaces.

PURPOSE: This study compared the speed and strength of osseointegration and osteoconductivity between an oxidized experimental magnesium (Mg) implant, an oxidized commercially available TiUnite implant, and a dual acid-etched surface Osseotite implant. The aim was to investigate which surface properties enhance bone response to implants, and thereby to test a biochemical bonding theory. MATERIALS AND METHODS: A total of 60 screw implants (20 of each design) were inserted through 1 cortex into the tibiae of 10 rabbits. Surface chemistry, oxide thickness, morphology, crystal structure, and surface roughness were evaluated. After healing times of 3 and 6 weeks, all bone implants were unscrewed with removal torque (RTQ) devices, and the bone specimens were subjected to histomorphometry. RESULTS: RTQ values for Mg, TiUnite, and Osseotite implants were 27.1, 21.3, and 15.4 Ncm, with new bone formation values of 29%, 18%, and 15%, respectively, at 3 weeks. At 6 weeks the RTQ values were 37.5, 36.4, and 21.5 Ncm, with new bone formation values of 39%, 31%, and 26%, respectively. DISCUSSION: Mg implants demonstrated significantly greater RTQ values (P = .008 and P = .0001) and more new bone formation (P = .031 and P = .030) than Osseotite at 3 and 6 weeks, respectively. Mg implants also showed higher RTQ values at 3 weeks and new bone formation at 6 weeks than TiUnite, but neither were significant (P > .05). TiUnite showed significantly higher RTQ values than Osseotite at 6 weeks (P = .001), but was not significant at 3 weeks (P > .05). Osseointegration rate (deltaRTQ/deltaweeks) was significantly faster for Mg (P = .011) and TiUnite (P = .001) implants between 3 and 6 weeks of healing time, but was not significant for Osseotite. CONCLUSIONS: The results indicate that surface chemistry facilitated more rapid and stronger osseointegration of the Mg implants despite their minimal roughness compared to the moderately roughened TiUnite. This suggests potential advantages of Mg implants for reducing high implant failure rates in the early postimplantation stage and in compromised bone, making it possible to shorten bone healing time from surgery to functional loading, and enhancing the possibility of immediate/early loading.