Search PubMed⌕ Search

Biomedical subjects

Timo O Reiss

Publications and source records attributed to Timo O Reiss.

6 recordsLinked to original sources

Tailoring the optimal control cost function to a desired output: application to minimizing phase errors in short broadband excitation pulses.

The de facto standard cost function has been used heretofore to characterize the performance of pulses designed using optimal control theory. The freedom to choose new, creative quality factors designed for specific purposes is demonstrated. While the methodology has more general applicability, its utility is illustrated by comparison to a consistently chosen example--broadband excitation. The resulting pulses are limited to the same maximum RF amplitude used previously and tolerate the same variation in RF homogeneity deemed relevant for standard high-resolution NMR probes. Design criteria are unchanged: transformation of I(z)--> I(x) over resonance offsets of +/-20 kHz and RF variability of +/-5%, with a peak RF amplitude equal to 17.5 kHz. However, the new cost effectively trades a small increase in residual z magnetization for improved phase in the transverse plane. Compared to previous broadband excitation by optimized pulses (BEBOP), significantly shorter pulses are achievable, with only marginally reduced performance. Simulations transform I(z) to greater than 0.98 I(x), with phase deviations of the final magnetization less than 2 degrees, over the targeted ranges of resonance offset and RF variability. Experimental performance is in excellent agreement with the simulations.

Algorithms↗

Improving solid-state NMR dipolar recoupling by optimal control.

We present the first solid-state NMR experiments developed using optimal control theory. Taking heteronuclear dipolar recoupling in magic-angle-spinning NMR as an example, it proves possible to significantly improve the efficiency of the experiments while introducing robustness toward instrumental imperfections such as radio frequency inhomogeneity. The improvements are demonstrated by numerical simulations as well as practical experiments on a 13Calpha,15N-labeled powder of glycine. The experiments demonstrate a gain of 53% in the efficiency for 15N to 13Calpha coherence transfer relative to the typically double-cross-polarization experiments.

Carbon Isotopes↗

Reducing the duration of broadband excitation pulses using optimal control with limited RF amplitude.

Combining optimal control theory with a new RF limiting step produces pulses with significantly reduced duration and improved performance for a given maximum RF amplitude compared to previous broadband excitation by optimized pulses (BEBOP). The resulting pulses tolerate variations in RF homogeneity relevant for standard high-resolution NMR probes. Design criteria were transformation of Iz-->Ix over resonance offsets of +/-20kHz and RF variability of +/-5%, with a pulse length of 500 micros and peak RF amplitude equal to 17.5 kHz. Simulations transform Iz to greater than 0.995 Ix, with phase deviations of the final magnetization less than 2 degrees, over ranges of resonance offset and RF variability that exceed the design targets. Experimental performance of the pulse is in excellent agreement with the simulations. Performance tradeoffs for yet shorter pulses or pulses with decreased digitization are also investigated.

Algorithms↗

Application of optimal control theory to the design of broadband excitation pulses for high-resolution NMR.

Optimal control theory is considered as a methodology for pulse sequence design in NMR. It provides the flexibility for systematically imposing desirable constraints on spin system evolution and therefore has a wealth of applications. We have chosen an elementary example to illustrate the capabilities of the optimal control formalism: broadband, constant phase excitation which tolerates miscalibration of RF power and variations in RF homogeneity relevant for standard high-resolution probes. The chosen design criteria were transformation of I(z)-->I(x) over resonance offsets of +/- 20 kHz and RF variability of +/-5%, with a pulse length of 2 ms. Simulations of the resulting pulse transform I(z)-->0.995I(x) over the target ranges in resonance offset and RF variability. Acceptably uniform excitation is obtained over a much larger range of RF variability (approximately 45%) than the strict design limits. The pulse performs well in simulations that include homonuclear and heteronuclear J-couplings. Experimental spectra obtained from 100% 13C-labeled lysine show only minimal coupling effects, in excellent agreement with the simulations. By increasing pulse power and reducing pulse length, we demonstrate experimental excitation of 1H over +/-32 kHz, with phase variations in the spectra <8 degrees and peak amplitudes >93% of maximum. Further improvements in broadband excitation by optimized pulses (BEBOP) may be possible by applying more sophisticated implementations of the optimal control formalism.

Algorithms↗

Broadband geodesic pulses for three spin systems: time-optimal realization of effective trilinear coupling terms and indirect SWAP gates.

Broadband implementations of time-optimal geodesic pulse elements are introduced for the efficient creation of effective trilinear coupling terms for spin systems consisting of three weakly coupled spins 1/2. Based on these pulse elements, the time-optimal implementation of indirect SWAP operations is demonstrated experimentally. The duration of indirect SWAP gates based on broadband geodesic sequence is reduced by 42.3% compared to conventional approaches.

Acetamides↗

Time-optimal coherence-order-selective transfer of in-phase coherence in heteronuclear IS spin systems.

Based on principles of geometric optimal control theory, coherence transfer building blocks can be derived which achieve optimal sensitivity. Here, experimental pulse sequences are presented that achieve the best possible coherence-order-selective in-phase transfer (S(-)-->I(-)) for a heteronuclear 2-spin system for any given mixing time in the absence of relaxation. For short mixing times, the optimal experiment improves the sensitivity of isotropic mixing by up to 12.5%.

Journal Article↗