Search PubMed⌕ Search

Biomedical subjects

Thomas Mang

Publications and source records attributed to Thomas Mang.

7 recordsLinked to original sources

CT colonography: techniques, indications, findings.

Computed tomographic colonography (CTC) is a minimally invasive technique for imaging the entire colon. Based on a helical thin-section CT of the cleansed and air-distended colon, two-dimensional and three-dimensional projections are used for image interpretation. Several clinical improvements in patient preparation, technical advances in CT, and new developments in evaluation software have allowed CTC to develop into a powerful diagnostic tool. It is already well established as a reliable diagnostic tool in symptomatic patients. Many experts currently consider CTC a comparable alternative to conventional colonoscopy, although there is still debate about its sensitivity for the detection of colonic polyps in a screening population. This article summarizes the main indications, the current techniques in patient preparation, data acquisition and data analysis as well as imaging features for common benign and malignant colorectal lesions.

Colonic Polyps↗

Advances in musculoskeletal radiology: multidetector computed tomography.

The clinical potential of multidetector CT is significantly increased because of the possibility of almost instantaneous isotropic reformations in all planes, increased speed and coverage, and easy interpretation. Multidetector CT has a significant role in the correct and quick diagnosis and treatment of emergency department patients. In complex anatomic regions, it is an important diagnostic aid, and it allows exact classification of the bony lesion, which is important for diagnosis, treatment, and prognosis. Multidetector CT visualizes congenital deformities and is useful in oncology. Ongoing developments comprise diagnosis and treatment, preoperative and postoperative planning, and hard-ware imaging. Relatively new but well-known applications of multidetector CT include intraoperative navigation, implant and prosthesis planning and surgery simulation, vertebroplasty, and pedicle screw installations.

Arthroplasty, Replacement, Hip↗

Management of postoperative esophageal leaks with the Polyflex self-expanding covered plastic stent.

BACKGROUND: Esophageal anastomotic leaks can lead to prolonged hospitalization. In this article we present our experience with the placement of the Polyflex self-expanding plastic stent (Willy Ruesch GMBH, Kernen, Germany) for leak occlusion. METHODS: Between April 2000 and November 2003, 24 patients were included into this prospective study and underwent Polyflex stent placement for postoperative esophageal anastomotic leaks. The primary operation was esophagectomy in 13 patients, gastrectomy in 7, cardia resection in 2, and other procedures in 2 patients. The median interval between operation and stent placement was 19 days (range, 4 to 65). The effectiveness of leak occlusion was evaluated by water-soluble contrast swallow and the clinical course. RESULTS: In 2 patients stent misplacement produced an enlarged anastomotic dehiscence that necessitated reoperation. Radiologic evaluation was impossible in 4 patients because of their generally restricted condition. Among 18 evaluable patients, leak occlusion was successful with a single stent in 16 patients (89%) based on radiologic evaluation. Immediate oral feeding was well tolerated by these patients. After a median follow-up of 220 days (range, 7 to 1221), 9 cases of late stent dislocation were observed. Stent removal in patients after esophagectomy with gastric pull-up led to dysphagia from anastomotic strictures in 2 patients. Symptomatic strictures did not develop in the 5 evaluable postgastrectomy patients after stent removal. CONCLUSIONS: The placement of self-expanding plastic stents is a highly effective treatment for esophageal anastomotic leaks. Because clinically-relevant anastomotic strictures can be expected, we do not recommend stent removal after esophagectomy with gastric pull-up reconstruction.

Adult↗

Soft-copy reading of digital chest radiographs: effect of ambient light and automatic optimization of monitor luminance.

OBJECTIVE: We sought to evaluate whether soft-copy reading of simulated pulmonary chest lesions is influenced by ambient light and automatic optimization of cathode ray tube (CRT) monitor luminance. MATERIALS AND METHODS: Four types of simulated lesions (nodules, lines, micronodules, and patchy opacities) were superimposed over an anthropomorphic chest phantom. Lesion detection with soft-copy reading was assessed using a high-contrast grayscale 2K CRT monitor under the following conditions: (1) subdued lighting (<50 lux); (2) normal lighting conditions (450 lux) without, and (3) with a sensitivity modulation to automatically adjust the CRT luminance to the increased amount of ambient light. Reading data were analyzed according to receiver operating curve. Significance of differences was tested using an analysis of variance for repeated measures. RESULTS: Ambient room light of 450 lux did not significantly influence the detection of nodules and patchy opacities. However, bright ambient light significantly decreased detection of micronodules (0.60 vs. 0.74) and lines (0.52 vs. 0.66) relative to subdued lighting conditions. Automatic luminance adjustment could compensate the effect of ambient light for the micronodules (0.77) but not for the lines (0.53). CONCLUSION: Bright ambient light significantly decreases detection of small low-contrast structures. This may be partially but not completely compensated by an automatic luminance adaptation.

Data Display↗

Three-dimensional volume rendering of multidetector-row CT data: applicable for emergency radiology.

Multidetector-row computed tomography (MD-CT) not only creates new opportunities but also challenges for medical imaging. Isotropic imaging allows in-depth views into anatomy and disease but the concomitant dramatic increase of image data requires new approaches to visualize, analyze and store CT data. The common diagnostic reviewing process slice by slice becomes more and more time consuming as the number of slice increases, while on the other hand CT volume data sets could be used for three-dimensional visualization. These techniques allow for comprehensive interpretation of extent of fracture, amount of dislocation and fragmentation in a three-dimensional highly detailed setting. Further more, using minimal invasive techniques like CT angiography, new opportunities for fast emergency room patient's work up arise. But the most common application is still trauma of the musculoskeletal system as well as face and head. The following is a brief review of recent literature on volume rendering technique and some exemplary applications for the emergency room.

Angiography↗

Single- and multi-slice spiral computed tomography of the paediatric kidney.

Single- and multi-slice computed tomography (CT) is regarded as the primary imaging tool in traumatology, both in adults and children. For complicated infectious disease and renal tumours, these techniques are recommended only as secondary diagnostic tools. Specifically, multi-slice CT (MSCT) provides excellent spatial resolution, which is a particular advantage for the evaluation of small structures as they are typical in children. However, MSCT offers more information than is required for diagnosis. Therefore, low-dose protocols are necessary for paediatric examinations. The CT dose-index (CTDI(vol)) should not exceed 2 mGy for newborns, 4 mGy for toddlers, 5 mGy for elementary school children, and 8 mGy for adolescents.

Adolescent↗

[Virtual multislice computed tomographic colonoscopy].

Virtual colonoscopy or computed tomographic (CT) colonography is a rapidly evolving technique for imaging the entire colon and detection of colorectal polyps. It uses standard helical computed tomography images of the colon and advanced imaging software to produce reformatted two- and three-dimensional views of the entire colorectum. Multi-detector row helical computed tomography has several technical advantages over single-detector row computed tomographic, including faster imaging times with the acquisition of thinner sections. The improved speed and spatial resolution of multislice computed tomography promises an increase of sensitivity and specificity, especially for the detection of colorectal lesions.

Colonic Polyps↗