Combined time-resolved and high-spatial-resolution 3D MRA using an extended adaptive acquisition.

PURPOSE: To combine the benefits of time-resolved dynamic imaging and single elliptical centric acquisitions in a reasonable scan time. MATERIALS AND METHODS: A time series of images with moderate spatial resolution was acquired using the 3D Time-Resolved Imaging of Contrast KineticS (3D TRICKS) technique with elliptical centric encoding during contrast arrival. Following venous opacification, a complete large centrically encoded k-space volume was acquired. The high-spatial-frequency portions of this volume were combined with a 3D TRICKS time frame to form a high-resolution image. An additional single image is formed by suppressing background and signal averaging all acquired data, including post-venous low-spatial-frequency data. For this image, 2D temporal correlation analysis is used to suppress low-spatial-frequency vein contributions. Arrival time and spatial correlations are used to suppress background. RESULTS: The 3D TRICKS time frame may be selected to ensure a combined high-resolution image that has optimal central k-space sampling for any vascular region. The single image formed by signal averaging all acquired data has increased contrast-to-noise (CNR) and signal-to-noise (SNR) ratios. CONCLUSION: The advantages of time-resolved and high-spatial-resolution imaging were combined using an extended dual-phase acquisition. Some SNR and CNR gain was achieved by signal averaging. This process is facilitated by background and vein suppression.

Animals↗

Time-resolved contrast-enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory.

Time-resolved contrast-enhanced 3D MR angiography (MRA) methods have gained in popularity but are still limited by the tradeoff between spatial and temporal resolution. A method is presented that greatly reduces this tradeoff by employing undersampled 3D projection reconstruction trajectories. The variable density k-space sampling intrinsic to this sequence is combined with temporal k-space interpolation to provide time frames as short as 4 s. This time resolution reduces the need for exact contrast timing while also providing dynamic information. Spatial resolution is determined primarily by the projection readout resolution and is thus isotropic across the FOV, which is also isotropic. Although undersampling the outer regions of k-space introduces aliased energy into the image, which may compromise resolution, this is not a limiting factor in high-contrast applications such as MRA. Results from phantom and volunteer studies are presented demonstrating isotropic resolution, broad coverage with an isotropic field of view (FOV), minimal projection reconstruction artifacts, and temporal information. In one application, a single breath-hold exam covering the entire pulmonary vasculature generates high-resolution, isotropic imaging volumes depicting the bolus passage.

Abdomen↗

Technical developments in MR angiography.

CE MRA has evolved rapidly since the early studies by Prince et al [3]. Whereas many of the procedures in clinical use today rely heavily on the use of gadolinium contrast agents and standard. Fourier transform acquisition techniques, advances will have a significant impact on MRA by shortening the acquisition time, improving the reproducibility of the image-acquisition techniques, and improving spatial resolution or SNR. From a technical basis, shorter acquisition times associated with fast gradients are likely to improve spatial resolution and allow for acquisition of MR images over large FOVs. In addition, alternative k-space sampling techniques, such as parallel imaging and PR, are expected to further reduce acquisition time, while maintaining or improving spatial resolution. The approval and subsequent use of new contrast agents will also have a beneficial impact on the image quality of contrast-enhanced MRA applications. It is likely that these contrast agents will be coupled with advanced acquisition techniques to improve spatial resolution and technical success rates of MRA examinations.

Biophysical Phenomena↗

Validation of injection parameters for catheter-directed intraarterial gadolinium-enhanced MR angiography.

RATIONALE AND OBJECTIVES: Catheter-directed intraarterial (IA) injections of gadolinium contrast agents may be used during endovascular interventions with magnetic resonance (MR) imaging guidance. Injection protocols require further validation. Using a flow phantom and swine, the authors aimed to (a) measure the optimal arterial gadolinium concentration ([Gd]) required for MR angiography and (b) validate a proposed IA injection protocol for gadolinium-enhanced MR angiography. MATERIALS AND METHODS: For in vitro experiments, the authors placed a catheter in the aorta of an aorto-renal-iliac flow phantom. Injected [Gd], injection rates, and aortic blood flow rates were varied independently for 36 separate IA gadolinium injections. The authors performed 2D and 3D MR angiography with a fast spoiled gradient-recalled echo sequence. For subsequent in vivo experiments, they selectively placed catheters within the aorta, renal artery, or common iliac artery of three pigs. Injection rate and injected [Gd] were varied. The authors performed 32 separate IA gadolinium injections for 2D MR angiography. Signal-to-noise ratios (SNRs) were compared for the various combinations of injection rate and injected [Gd]. RESULTS: In vitro, an arterial [Gd] of 2%-4% produced an optimal SNR for 2D MR angiography, and 3%-5% was best for 3D MR angiography. In swine, an arterial [Gd] of 1%-4% produced an optimal SNR. In the phantom and swine experiments, SNR was maintained at higher injection rates by inversely varying the injected [Gd]. CONCLUSION: Dilute arterial [Gd] is required for optimal IA gadolinium-enhanced MR angiography. To maintain an optimal SNR, injection rates and injected [Gd] should be varied inversely. The postulated injection protocol was validated.

Animals↗

Time-resolved three-dimensional contrast-enhanced MR angiography of the peripheral vessels.

PURPOSE: To compare the diagnostic accuracy of time-resolved three-dimensional contrast material-enhanced magnetic resonance (MR) angiography with that of conventional angiography for imaging the lower extremity vasculature. MATERIALS AND METHODS: Sixty-nine patients who were evaluated for possible surgical intervention underwent conventional angiography (ie, digital subtraction angiography [DSA]) and contrast-enhanced MR angiography (ie, time-resolved imaging of contrast kinetics [TRICKS]). Two independent, blinded readers evaluated vessel stenosis and occlusion at DSA and MR angiographic image readings. Sensitivity, specificity, positive and negative predictive values, and area under the receiver operating characteristic curve were analyzed with repeated-measures analysis of variance. The Cohen kappa test was performed to examine interreader variability. RESULTS: At pooled readings, contrast-enhanced MR angiography had a sensitivity of 78% and a specificity of 98% for detection of occlusion. For detection of significant stenosis (at least one > or = 50% stenosis), sensitivity and specificity were 77% and 91%, respectively. Interreader agreement was high for detection of both occlusion (kappa = 0.76) and significant stenosis (kappa = 0.68). Sensitivity increased as MR angiographic technical parameters were optimized. When improvements resulting from coil type and injection protocol were considered, the sensitivity and specificity of TRICKS MR angiography were 89% and 97%, respectively, for occlusion detection and 87% and 90%, respectively, for significant stenosis detection. CONCLUSION: Contrast-enhanced TRICKS MR angiography is a feasible and minimally invasive means of acquiring angiograms of the peripheral vasculature with high sensitivity and specificity.

Adult↗

Comparison of intraarterial and IV gadolinium-enhanced MR angiography with digital subtraction angiography for the detection of renal artery stenosis in pigs.

OBJECTIVE: Catheter-based intraarterial injections of gadolinium are useful during MR imaging-guided endovascular procedures to generate rapid vascular road maps. Using an animal model of renal artery stenosis, we tested the hypothesis that intraarterial gadolinium-enhanced MR angiography is as accurate as IV gadolinium-enhanced MR angiography and digital subtraction angiography (DSA). We also tested the hypothesis that intraarterial MR angiography uses less gadolinium than IV MR angiography. MATERIALS AND METHODS: We induced bilateral renal artery stenosis in five pigs. All pigs underwent comparative imaging with DSA, IV MR angiography, and aortic catheter-directed intraarterial MR angiography. For IV and intraarterial MR angiography, we used the same three-dimensional acquisition. We assessed differences in quantitative stenosis measurements among DSA, IV MR angiography, and intraarterial MR angiography using the Wilcoxon's signed rank test. RESULTS: Mean stenosis measurements (+/-SD) were as follows: DSA, 58% +/- 12%; IV MR angiography, 63% +/- 9.3%; and intraarterial MR angiography, 64% +/- 11%. There were no statistically significant differences in accuracy between DSA and IV MR angiography (p = 0.06), DSA and intraarterial MR angiography (p = 0.16), or IV and intraarterial MR angiography (p = 0.70). Intraarterial MR angiography used a mean gadolinium dose of 5.6 mL, compared with 9 mL for IV MR angiography. CONCLUSION: In swine, IV and intraarterial MR angiography have a similar accuracy for detecting renal artery stenosis. Intraarterial MR angiography uses smaller doses of injected gadolinium.

Angiography, Digital Subtraction↗