Search PubMed⌕ Search

Biomedical subjects

Thomas J Balkany

Publications and source records attributed to Thomas J Balkany.

At least 19 recordsLinked to original sources

Blocking c-Jun-N-terminal kinase signaling can prevent hearing loss induced by both electrode insertion trauma and neomycin ototoxicity.

Neomycin ototoxicity and electrode insertion trauma both involve activation of the mitogen activated protein kinase (MAPK)/c-Jun-N-terminal kinase (JNK) cell death signal cascade. This article discusses mechanisms of cell death on a cell biology level (e.g. necrosis and apoptosis) and proposes the blocking of JNK signaling as a therapeutic approach for preventing the development of a permanent hearing loss that can be initiated by either neomycin ototoxicity or electrode insertion trauma. Blocking of JNK molecules incorporates the use of a peptide inhibitor (i.e. D-JNKI-1), which is specific for all three isoforms of JNK and has been demonstrated to prevent loss of hearing following either electrode insertion trauma or loss of both hearing and hair cells following exposure to an ototoxic level of neomycin. We present previously unpublished results that control for the effect of perfusate washout of aminoglycoside antibiotic by perfusion of the scala tympani with an inactive form of D-JNKI-1 peptide, i.e. JNKI-1(mut) peptide, which was not presented in the original J. Neurosci. article that tested locally delivered D-JNKI-1 peptide against both noise- and neomycin-induced hearing loss (i.e. Wang, J., Van De Water, T.R., Bonny, C., de Ribaupierre, F., Puel, J.L., Zine, A. 2003a. A peptide inhibitor of c-Jun N-terminal kinase protects against both aminoglycoside and acoustic trauma-induced auditory hair cell death and hearing loss. J. Neurosci. 23, 8596-8607). D-JNKI-1 is a cell permeable peptide that blocks JNK signaling at the level of the three JNK molecular isoforms, which when blocked prevents the increases in hearing thresholds and the loss of auditory hair cells. This unique therapeutic approach may have clinical application for preventing: (1) hearing loss caused by neomycin ototoxicity; and (2) the progressive component of electrode insertion trauma-induced hearing loss.

Animals↗

Revision cochlear implantation for facial nerve stimulation in otosclerosis.

OBJECTIVE: To find if patients experiencing postsurgical facial nerve stimulation caused by underlying disease process (ie, otosclerosis) can improve their hearing performance with their cochlear implant by reimplantation and by an optimal programming strategy. DESIGN: Retrospective analysis. SETTING: Academic tertiary referral center. PATIENTS: Two cochlear otosclerosis patients with resistant facial nerve stimulation (FNS). Both patients were initially implanted with Nucleus 22 devices (Cochlear Corporation, Englewood, Colo) and they developed FNS after a period of use. Owing to the decreasing number of active electrodes, concurrent decreases in speech understanding occurred. INTERVENTIONS: Various programming approaches were used to address the FNS. Both subjects ultimately received Nucleus 24 devices. One was reimplanted in the same ear, and the other was implanted in the opposite ear. Both have been followed up for 8 months following the reimplantation. MAIN OUTCOME MEASURES: Cochlear implant programming levels, cochlear implant performance, and facial nerve stimulation. RESULTS: The FNS was managed for more than 3 years through optimized programming. However, the FNS progressed until performance dropped below acceptable levels. Reimplantation was believed to be the only option for improvement. After reimplantation and programming, both subjects showed immediate improvement in speech discrimination. One user increased his consonant-nucleus-consonant word score from 12% preoperatively to 42%, and the other's performance increased from 0% to 86%. CONCLUSIONS: Our results suggest that having more programming options with newer devices is critical in otosclerotic or ossified users who experience FNS. Also, reimplantation may be a useful tool to improve performance.

Cochlear Implantation↗

Cochlear implants.

Cochlear implants are cost-effective auditory prostheses that safely provide a high-quality sensation of hearing to adults who are severely or profoundly deaf. In the past 5 years, progress has been made in hardware and software design, candidate selection, surgical techniques, device programming, education and rehabilitation,and, most importantly, outcomes. Cochlear implantation in the elderly is well tolerated and provides marked improvement in auditory performance and psychosocial functioning.

Aged↗

Glutathione ester protects against hydroxynonenal-induced loss of auditory hair cells.

OBJECTIVE: Test the ability of glutathione monoethyl ester (GSH(e)) to protect auditory hair cells against the ototoxic effects of 4-hydroxy-2,3-nonenal (HNE). STUDY DESIGN AND SETTING: Organ of Corti explants were either untreated or treated with one of a series of four concentrations of GSH(e) for one day, then exposed to HNE. Counts of FITC-phalloidin-labeled hair cells determined both HNE ototoxicity and GSH(e) otoprotection. RESULTS: HNE was toxic to hair cells at physiologically relevant levels, eg, 400 muM, and GSH(e) provided a significant level of protection against HNE ototoxicity (P < 0.05) at all levels tested, ie, 1.16 to 9.3 mM. CONCLUSION: GSH(e) protects auditory hair cells from damage and loss initiated by a naturally occurring ototoxic molecule, ie, HNE (a by-product of oxidative stress). SIGNIFICANCE: Treatment with GSH(e) may be an effective therapy to protect the cochlea against the adverse effects of traumas (eg, electrode insertion) that generate oxidative stress.

Aldehydes↗

Triamcinolone acetonide protects auditory hair cells from 4-hydroxy-2,3-nonenal (HNE) ototoxicity in vitro.

CONCLUSION: Triamcinolone acetonide crystalline suspension (e.g. Volon A) was not ototoxic to the auditory hair cells present within organ of Corti explants and protected them from an ototoxic molecule, i.e. 4-hydroxy-2,3-nonenal (HNE), that is produced within the organ of Corti as a result of oxidative stress-induced damage. OBJECTIVES: To test the corticosteroid, triamcinolone acetonide, for ototoxicity and otoprotective capacity in organ of Corti explants. MATERIALS AND METHODS: Organ of Corti explants excised from 4-day-old rats were the test system, HNE was the ototoxin challenge. Hair cell integrity counts were performed with fluorescent microscopy on fixed explants stained with FITC-labeled phalloidin. Statistical significance was set at p<0.05. RESULTS: Triamcinolone acetonide did not affect hair cell integrity in the organ of Corti explants and it provided a high level of protection of hair cells against the ototoxic effects of a damaging level of HNE as determined by hair cell density counts.

Aldehydes↗

D-JNKI-1 treatment prevents the progression of hearing loss in a model of cochlear implantation trauma.

HYPOTHESES: 1) Hearing loss caused by electrode insertion trauma has both acute and delayed components; and 2) the delayed component of trauma-initiated hearing loss can be prevented by a direct delivery of a peptide inhibitor of the c-Jun N-terminal kinase cell death signal cascade, that is, D-JNKI-1, immediately after the electrode insertion within the cochlea. BACKGROUND: Acute trauma to the macroscopic elements of the cochlea from electrode insertion is well known. The impact of trauma-induced oxidative stress within injured cochlear tissues and the efficacy of drugs (e.g., D-JNKI-1) to prevent apoptosis of damaged hair cells is not well defined. METHODS: Hearing function was tested by pure-tone evoked auditory brainstem responses (ABRs) and distortion products of otoacoustic emissions (DPOAEs). D-JNKI-1 in artificial perilymph (AP) or AP alone was delivered into the scala tympani immediately after electrode trauma and for 7 days. Controls were nontreated contralateral and D-JNKI-1-treated ears without electrode insertion trauma. RESULTS: There was no increase in the hearing thresholds of either the contralateral control ears or in the D-JNKI-1 without trauma animals. There was a progressive increase in ABR thresholds and decrease in DPOAE amplitudes after electrode insertion trauma in untreated and in AP-treated cochleae. Treatment with D-JNKI-1 prevented the progressive increase in ABR thresholds and decrease in DPOAE amplitudes that occur after electrode insertion trauma. CONCLUSION: Hearing loss caused by cochlear implant electrode insertion trauma in guinea pigs has both acute and delayed components. The delayed component can be prevented by treating the cochlea with D-JNKI-1.

Analysis of Variance↗

Vibrant soundbridge surgery: evaluation of transcanal surgical approaches.

UNLABELLED: Since its introduction, surgery for the placement of the Vibrant Soundbridge (VSB) device has been performed using a facial recess approach. Because of the size of the VSB device, this approach requires a large facial recess that can lead to complications, i.e., facial palsy and/or taste disturbance. The purpose of this study is to develop and compare transcanal surgical approaches for leading the VSB into the middle ear. SETTING: Cadaver temporal bones in a university temporal bone laboratory. MATERIALS AND METHODS: First, two experienced senior surgeons validated the three possible approaches in human temporal bone: 1) the classical facial recess approach; 2) a small mastoidectomy, elevation of a tympanomeatal flap, small atticotomy, 0.5-mm cutting of the bony external auditory canal (EAC) from the cortical plane on its approximately two-thirds to three-fourths and then a trough to pass the electrode array into the middle ear; and 3) similar to the second approach but with replacing the cutting of the bony EAC with a tunnel from the mastoid cavity to the EAC. Both the second and third approaches were transcanal. Next, five residents and six attending surgeons performed the three operations and evaluate these different approaches by using analog visual scales (VAS) for each procedure. They assess the following: 1) the ease of passing the electrode array and the Floating Mass Transducer (FMT) into the middle ear, 2) the ease for FMT clipping, and 3) their self-confidence using each approach. Time required for the three operations was measured. Measurements of landmarks were obtained on all temporal bones. Two patient cases illustrate the clinical application of this new surgical approach. RESULTS: The two transcanal approaches were assessed to be easier, faster, and safer methods for VSB surgery than the classic facial recess approach. CONCLUSION: VSB surgery has been performed using a facial recess approach with risk for facial nerve and taste disturbance. Transcanal approaches are good alternative for this surgery. Three major limitations are to be assessed in future patient studies: the pathologic findings of the EAC, the design of the FMT regarding the axis of the ossicular chain, the long-term evaluation of the skin of the external ear canal.

Aged↗

Conservation of residual acoustic hearing after cochlear implantation.

OBJECTIVE: This study was designed to test the hypothesis that partial hearing conservation is attainable after cochlear implantation with a long perimodiolar electrode. Surgical strategies for hearing conservation during cochlear implantation are described. STUDY DESIGN: Prospective, single-subject, repeated-measures design. SETTING: Academic tertiary care center. PATIENTS: Twenty-eight severely to profoundly hearing-impaired adult cochlear implant recipients who had some measurable hearing preoperatively. INTERVENTION: Cochlear implantation using Nucleus Freedom Contour Advance electrode. MAIN OUTCOME MEASURES: Preimplant and postimplant pure-tone thresholds and speech recognition scores were obtained to determine the incidence and degree of conserved hearing at a mean interval of 9 (+/-3.9) months. RESULTS: Thirty-two percent of subjects experienced complete conservation of hearing (0- to 10-dB loss), and 57% experienced partial conservation of hearing (>11 dB) after implantation. However, open-set speech recognition was partially conserved in only one subject. Cochlear implant performance was not better in patients with conservation of residual hearing. CONCLUSION: Conservation of pure-tone hearing was possible in 89% of implanted patients; however, residual speech perception was not conserved with this long perimodiolar electrode. A ceiling effect tends to inflate the prevalence of hearing conservation in implantation studies of severely to profoundly hearing-impaired patients.

Adult↗

Etiologic diagnosis of sensorineural hearing loss in adults.

OBJECTIVE: To determine the etiology of adult-onset sensorineural hearing loss. STUDY DESIGN AND SETTING: This is a prospective cohort study of 60 adult subjects with bilateral sensorineural hearing loss of no obvious etiology by medical history and physical examination. These patients were evaluated at an academic medical center and underwent evaluation by high-resolution computed tomography of the temporal bone, autoimmune panel, and DNA testing for mutations of both the GJB2 gene and the mitochondrial DNA (1555A>G and 7445A>G). RESULTS: An etiologic diagnosis was achieved in 6 patients: cochlear otosclerosis, 1 case; dilated vestibular aqueduct, 1 case; a mitochondrial DNA 7445A>G mutation, 3 cases; and a mitochondrial DNA 1555A>G mutation, 1 case. CONCLUSION: This result underscores the importance of a search for the etiology of a hearing deficit in adult patients. There are specific interventions now available for the management of hearing-impaired patients with cochlear otosclerosis and mitochondrial DNA mutations.

Adult↗

Cochlear temperature correlates with both temporalis muscle and rectal temperatures. Application for testing the otoprotective effect of hypothermia.

CONCLUSIONS: During systemic hypothermia, the internal temperature of the rat cochlea correlates best with the temporalis muscle and rectal temperatures. These positive correlations will be used in future studies to assess the efficacy of mild and moderate hypothermia to protect hearing against the progressive loss caused by electrode insertion in a clinically relevant model of cochlear implantation trauma. OBJECTIVE: To monitor the internal temperature of the cochlea during induced systemic hypothermia using a reference tissue instead of an internal cochlear temperature probe. MATERIAL AND METHODS: The temperatures of the cochlea, brain, temporalis muscle and rectum were determined during periods of normothermia (37 degrees C), mild (33 degrees C) and moderate (30 degrees C) hypothermia and slow rewarming in anesthetized adult Fisher rats. These values were compared using statistical analysis to establish the best correlations between the temperature of the cochlea and the temperature at the three other temperature measurement sites. RESULTS: The strongest correlations with the internal temperature of the cochlea during the induction of mild-to-moderate hypothermia were obtained for the temperatures of the ipsilateral temporalis muscle and rectum.

Animals↗

Pattern of hearing loss in a rat model of cochlear implantation trauma.

HYPOTHESIS: Trauma caused by cochlear implant electrode insertion is attributable to the combination of direct physical trauma and the delayed cell death of oxidative stress-injured auditory sensory cells. BACKGROUND: Histologic evaluation of cochlear implant electrode trauma has demonstrated that the extent of sensory cell losses is proportional to the degree of injury. However, the impact of delayed oxidative stress within injured cochlear tissues and the progressive loss of injured hair cells by way of apoptosis are at present unknown. METHODS: Laboratory rats were evaluated for hearing acuity before and after electrode insertion, before and after round window membrane incision only. Hearing was measured before trauma or incision and over the next 7 days. Objective measurements of hearing function were distortion products of otoacoustic emissions (DPOAEs) in the frequency range of 2 to 32 kHz and tone-burst (i.e., 4-32 kHz) evoked auditory brain stem responses (ABRs). RESULTS: For the experimental cochleae, there were progressive increases in ABR thresholds and decreases in ABR amplitudes. The amplitude of the DPOAEs in the experimental cochleae also showed progressive decreases. For the contralateral control and round window membrane surgical control ears, there were no significant changes in either DPOAE or ABR thresholds. CONCLUSION: These results document a progressive loss of hearing acuity postimplantation and strongly suggest that electrode insertion trauma generated oxidative stress within injured cochlear tissues.

Animals↗

Facial nerve stimulation after cochlear implantation.

OBJECTIVES: This study was designed to compare the incidence and nature of facial nerve stimulation (FNS) in patients receiving cochlear implants (CI) manufactured by Cochlear Corporation, Advanced Bionics Corporation, and MedEl. STUDY DESIGN: Retrospective chart review at a tertiary referral center. METHODS: The charts of 600 patients who received CIs from 1993 to 2003 with at least 1 year of follow-up were reviewed for significant FNS (FNS on at least 1 channel at functional stimulation levels). Data collected included age, sex, etiology of deafness, device type, electrode, FNS onset after initial stimulation, number and location of electrode contacts causing FNS, and loudness level at which FSN occurred. Nucleus straight and perimodiolar electrodes were also compared. RESULTS: Thirty-nine of 600 (6.5%) patients had FNS on at least one channel, (MedEl 3 of 43 [7.0%], Nucleus 29 of 440 [6.6%], and Clarion 7 of 117 [6.0%]). The incidence of FNS in Nucleus perimodiolar electrodes (16 of 250 [6.4%]) was similar to straight electrodes (13 of 190 (6.8%]), as was the mean number of electrodes causing FNS per patient (11 vs. 12). However, straight electrodes caused stimulation at significantly softer perceived loudness levels than perimodiolar electrodes (P < .0001). CONCLUSIONS: In this large series of CI FNS, the overall incidence of FNS is consistent with previous reports. All devices had a similar incidence of FNS, but perimodiolar electrodes produced FNS only at significantly higher loudness levels than straight electrodes, making them preferable for patients at risk for FNS receiving Nucleus devices.

Adolescent↗

Mild hypothermia protects auditory function during cochlear implant surgery.

OBJECTIVE/HYPOTHESIS: Loss of auditory function after cochlear implant (CI) electrode insertion occurs in two stages in the laboratory rat. An immediate loss is followed by a progressive loss over 7 days. Similar stages of acute and progressive neuronal loss occur after trauma in the central nervous system where hypothermia has been shown to have a protective effect. We hypothesize that hypothermia has a similar protective effect against loss of auditory function caused by CI electrode insertion trauma. METHODS: Thirty rats underwent surgery in one cochlea; the contralateral ear was an unoperated control. In the normothermia group, CI electrode insertion trauma was generated with rectal temperature maintained at 37 degrees C throughout the experiment. In the mild hypothermia group, electrode trauma was generated with rectal temperature lowered to 34 degrees C. In the surgical control group, mock surgery was performed at 37 degrees C. Multiple frequency auditory brainstem response (ABR) and distortion product otoacoustic emission (DPOAE) testing of all ears was performed before surgery, immediately afterward, and on postoperative days 3, 5, and 7. RESULTS: Both ABR and DPOAE testing demonstrated partial loss of auditory function after electrode insertion trauma. However, the hypothermia group had significantly less functional loss in the immediate stage and no significant loss in the progressive stage. CONCLUSION: Mild hypothermia protects auditory function during CI electrode insertion.

Animals↗

Evaluation of hearing and auditory nerve function by combining ABR, DPOAE and eABR tests into a single recording session.

In this article, we describe an efficient method for testing both auditory receptor and auditory nerve function in a single recording session. Auditory receptor function is tested in response to pure tone, tone burst and click acoustic stimuli (i.e. distortion products of otoacoustic emissions, DPOAE; and auditory-evoked brainstem responses, ABR). The function of the auditory neurons and nerve is measured in response to direct electric current stimulation (i.e. electrically evoked auditory brainstem responses, eABR). All measurements were obtained from anesthetized laboratory rats during single recording sessions using hardware and software stimulation and analysis programs developed by Intelligent Hearing Systems, Miami, FL.

Acoustic Stimulation↗

Changes in programming over time in postmeningitis cochlear implant users.

OBJECTIVE: Although successful cochlear implantation of patients with deafness following meningitis is expected, long-term stability of electrical current requirements has not been systematically evaluated. This study evaluated changes in programming for patients deafened by bacterial meningitis and stability of auditory performance over time. STUDY DESIGN AND SETTING: In this retrospective descriptive study, cochlear implant (CI) stimulation mode and performance of 14 patients deafened by meningitis were compared with those of an age-matched control group of patients deafened by other causes. RESULTS: There were no significant differences in mean performance between the meningitis group and control group (P > 0.05). However, the postmeningitis group required progressively higher stimulation levels and higher programming modes over time as compared to the control group. CONCLUSIONS: Even with deafness accompanied by labyrinthine ossification attributed to meningitis, neural elements were present and could be stimulated. Because increasing levels of stimulation were required over time, postmeningitic children with CIs, and those with cochlear ossification in particular, may need frequent programming adjustments to maintain performance. SIGNIFICANCE: These patients need close follow-up of stimulation levels and programming modes postoperatively in order to perform optimally with CIs. EBM RATING: B-3.

Adolescent↗

Further prospective findings with compound action potentials from Nucleus 24 cochlear implants.

The purpose of this study was to gain greater understanding of compound action potential (CAP) specific characteristics including: slope of the growth function, P1-N1 amplitude, threshold and latencies of P1 and N1 measured in cochlear implant users. Experienced adult subjects underwent behavioral threshold (T) measurement and electrically elicited stapedial reflex (eSR) recording, followed by CAP measurements on six selected electrodes. Based on the electrically elicited stapedial reflex threshold (eSRT), maximum stimulation level for each measured electrode was set. Relationships among the three thresholds of the above measures and maximum CAP P1-N1 amplitude and slope of the growth function were statistically evaluated for each measured electrode. Threshold of the CAP response showed relationships of similar strength with eSRT and T (r=0.69 and 0.61, respectively). For both slope of the growth function and CAP P1-N1 amplitude, a statistically significant relationship with cochlear place was found. Both specific characteristics of CAP measurement for the most apical electrodes were roughly double those for the most basal electrode (alpha=0.05). This may be partially explained by cochlear anatomy and is consistent with prior mammalian and human studies showing increasing density and survival of spiral ganglion cells in the regions corresponding to intracochlear electrode placement from basal to apical electrodes (90-360 degrees ).

Action Potentials↗

Vestibular effects of cochlear implantation.

OBJECTIVES/HYPOTHESIS: Cochlear implantation (CI) carries with it the potential risk for vestibular system insult or stimulation with resultant dysfunction. As candidate profiles continue to evolve and with the recent development of bilateral CI, understanding the significance of this risk takes on an increasing importance. STUDY DESIGN: Between 1997 to 2001, a prospective observational study was carried out in a tertiary care medical center to assess the effects of unilateral CI on the vestibular system. METHODS: Assessment was performed using the dizziness handicap inventory (DHI), vestibulo-ocular reflex (VOR) testing using both alternate bithermal caloric irrigations (ENG) and rotational chair-generated sinusoidal harmonic accelerations (SHA), and computerized dynamic platform posturography (CDP) at preoperative, 1-month, 4-month, 1-year and 2-year postimplantation visits. CI was carried out without respect to the preoperative vestibular function test results. RESULTS: Specifically, 86 patients were entered into the study after informed consent. For the group as a whole, pair wise comparisons revealed few significant differences between preoperative and postoperative values for VOR testing (ENG and SHA) at any of the follow-up intervals. Likewise, DHI testing was also unchanged except for significant reductions (improvements) in the emotional subcategory scores at both the 4-month and 1-year intervals. CDP results demonstrated substantial improvements in postural sway in the vestibular conditions (5 and 6) as well as composite scores with the device "off" and "on" at the 1-month, 4-month, 1-year, and 2-year intervals. Device activation appeared to improve postural stability in some conditions. Excluding those patients with preoperative areflexic or hyporeflexic responses in the implanted ear (total [warm + cool] caloric response or=21 deg/s maximum slow phase velocity) in total caloric response were observed for 8 (29%) patients at the 4-month interval. These persisted throughout the study period. These changes were accompanied by significant low frequency phase changes on SHA testing confirming a VOR insult. Of interest, no significant changes were detected in the DHI or CDP, and there were no effects of age, sex, device manufacturer, or etiology of hearing loss (HL) for these patients. CONCLUSIONS: Unilateral CI rarely results in significant adverse effects on the vestibular system as measured by the DHI, ENG, SHA, and CDP. On the contrary, patients that underwent CI experienced significant improvements in the objective measures of postural stability as measured by CDP. Device activation in music appeared to have an additional positive effect on postural stability during CDP testing. Although VOR testing demonstrated some decreases in response, patients did not suffer from disabling vestibular effects following CI. The mechanism underlying these findings remains speculative. These findings should be considered in counseling patients about CI.

Adolescent↗

Pediatric tympanoplasty: effect of contralateral ear status on outcomes.

OBJECTIVE: To assess the prognostic value of different variables on the outcome of pediatric type I tympanoplasty. DESIGN: Retrospective review of medical records. SETTING: An otolaryngology department in a large urban tertiary care medical center. PATIENTS: We reviewed 72 ears in 60 patients who had undergone a type I tympanoplasty from 1987 to 2000. Patient ages ranged from 3 to 18 years. INTERVENTIONS: Type I tympanoplasty. MAIN OUTCOME MEASURES: We identified the following 3 criteria for success: (1) healing of the neotympanic graft; (2) healing of the graft with a postoperative air-bone gap of no greater than 20 dB; and (3) healing of the graft with aeration of the middle ear space. RESULTS: Healing occurred in 59 (82%) of the 72 neotympanic grafts; 39 (83%) of the 47 healed ears for which a postoperative audiogram was available had an air-bone gap of no greater than 20 dB; and 49 (83%) of the 59 healed ears had a normally aerated middle ear space. A statistically significant difference in the rate of graft healing was identified for large perforations (76%), as well as for creation of an aerated middle ear space, when there was evidence of ongoing contralateral eustachian tube dysfunction (ie, otitis media with effusion or negative middle ear pressure, but not a perforation). CONCLUSIONS: Pediatric type I tympanoplasty can offer reasonably good chances for postoperative graft healing, serviceable hearing, and creation of an air-containing middle ear space if performed in carefully selected patients. Caution should be exercised in performing tympanoplasty in children with evidence of ongoing eustachian tube dysfunction, as evidenced by otitis media with effusion and negative middle ear pressure, but not perforations, in the contralateral ear.

Adolescent↗