Search PubMed⌕ Search

Biomedical subjects

Teruo Okano

Publications and source records attributed to Teruo Okano.

At least 55 records · Page 3Linked to original sources

Long-term survival and growth of pulsatile myocardial tissue grafts engineered by the layering of cardiomyocyte sheets.

Recently researchers have attempted to bioengineer three-dimensional (3-D) myocardial tissues using cultured cells in order to repair damaged hearts. In contrast to the conventional approach of seeding cells onto 3-D biodegradable scaffolds, we have explored a novel technology called cell sheet engineering, which layers cell sheets to construct functional tissue grafts. In this study, in vivo survival, function, and morphology of myocardial tissue grafts were examined. Neonatal rat cardiomyocytes were noninvasively harvested as contiguous cell sheets from temperature-responsive culture dishes simply by reducing the culture temperature. Cardiomyocyte sheets were then layered and transplanted into the subcutaneous tissues of athymic rats. The microvasculature of the grafts was rapidly organized within a few days with macroscopic graft beatings observed 3 days after transplantation and preserved up to one year. Size, conduction velocity, and contractile force of transplanted grafts increased in proportion to the host growth. Histological studies showed characteristic structures of heart tissue, including elongated cardiomyocytes, well-differentiated sarcomeres, and gap junctions within the grafts. In conclusion, long-term survival and growth of pulsatile myocardial tissue grafts fabricated by layering cell sheets were confirmed, demonstrating that myocardial tissue regeneration based on cell sheet engineering may prove useful for permanent myocardial tissue repair.

Animals↗

Transplantation of tissue-engineered epithelial cell sheets after excimer laser photoablation reduces postoperative corneal haze.

PURPOSE: To apply tissue-engineered cell sheet transplantation after excimer laser keratectomy as a novel approach for the reduction of postoperative corneal haze. METHODS: Limbal biopsy specimens were obtained, and epithelial cells were cultured on temperature-responsive culture inserts without the use of feeder cells. Laser keratectomy (7.0-mm ablation zone and 160-microm depth) was performed in the contralateral eye, and autologous epithelial cell sheets were transplanted to the ablated corneal stroma. Transplant and control group eyes were assessed by slit lamp biomicroscopy, and corneal haze was scored in a masked fashion, according to the Fantes grading scale. For further examination histologic and immunohistochemical analyses were performed. RESULTS: Tissue-engineered cell sheets produced stable attachment to the laser-ablated sites, resulting in epithelialization, 5 minutes after transplantation. Conversely, control corneas required 3 to 5 days for complete re-epithelialization. At both 1 and 2 months after surgery, corneal haze was significantly inhibited in the transplant group. Histologic analyses showed that the number of keratocytes undergoing apoptosis was decreased in the transplant group at 3 days after surgery. Similarly, the expression of both collagen III and alpha-smooth muscle actin, which may enhance corneal haze, were diminished in the transplant group at 2 months. CONCLUSIONS: The transplantation of tissue-engineered epithelial cell sheets can successfully prevent the development of corneal haze after excimer laser keratectomy.

Actins↗

Separation of nucleotides with an aqueous mobile phase using pH- and temperature-responsive polymer modified packing materials.

A new method for the qualitative analysis of adenosine nucleotides (AMP, ADP, and ATP) and synthetic oligonucleotides has been proposed, utilizing a pH- and temperature-responsive polymer of N-isopropylacrylamide (NIPAAm), butyl methacrylate (BMA) and N,N-dimethylaminopropylacrylamide (DMAPAAm) as the stationary phase of HPLC. In the chromatographic system using the copolymer with ionizable groups of modified packing materials, we investigated how to separate adenosine nucleotides and oligonucleotides by temperature. The properties of the surface of the copolymer-grafted stationary phase altered from hydrophilic to hydrophobic and from charged to non-charged due to changes in the temperature and in the pH, respectively. In addition, it is possible to exhibit and hide ion-exchange groups on the polymer chain surface by temperature changes. These phenomena result from changes in the charge and hydrophobicity of the pH- and temperature-responsive polymer on the stationary surface with the controlling temperature. A pH- and temperature-responsive chromatography would be greatly useful for biopolymer and nucleotide separation and purification.

Acrylamides↗

[Nanotechnology-based regenerative medicine--cell sheet engineering utilizing temperature-responsive culture dishes].

Regenerative medicine is believed to overcome shortcomings of conventional therapies including symptomatic drug therapy and surgical removal. We have utilized nanotechnology for regenerative medicine to develop temperature-responsive culture dishes, on which a temperature-responsive polymer is covalently grafted with precise control of its density and thickness in a nanometer scale. Confluent cells cultured on the dishes are intactly harvested as a single contiguous cell sheet by reducing temperature below 32 degrees C, and harvested cell sheets are subjected to tissue reconstruction, named cell sheet engineering. Here, we introduce the examples of clinical applications including corneal regeneration as well as large animal studies.

Animals↗

Tissue cardiomyoplasty using bioengineered contractile cardiomyocyte sheets to repair damaged myocardium: their integration with recipient myocardium.

BACKGROUND: We hypothesized that tissue-engineered contractile cardiomyocyte sheets without a scaffold would show histological and electrical integration with impaired myocardium, leading to the regeneration of infarcted myocardium. METHODS: Neonatal rat cardiomyocytes were cultured on Poly(N-isopropylacrylamide)-grafted polystyrene dishes and detached as a square cell sheet at 20 degrees C. Two sheets were stacked to make thicker contractile cardiac sheets. In cross-section, the stacked sheets looked like homogeneous heart-like tissue. Two weeks after rats were subjected to left anterior descending (LAD) ligation, two treatments were conducted: 1) cardiomyocyte sheet implantation (T group, n=10), and 2) fibroblast sheet implantation (F group, n=10). The control group underwent no additional treatment (C group, n=10). RESULTS: Echocardiography demonstrated that cardiac performance was significantly ameliorated in the T group 2, 4, and 8 weeks after implantation. The cardiomyocyte sheets became attached to the infarcted myocardium, showed angiogenesis, expressed connexin-43, and appeared as homogeneous tissue in the myocardium Electrophysiological experiments showed a QRS complex with one peak in the treated scar area in the T group, but two peaks, indicative of branch block, in that of the other groups. Furthermore, the threshold for pacing of the recipient heart was lower in the T group than in the other groups. CONCLUSIONS: Cardiomyocyte sheets integrated with the impaired myocardium and improved cardiac performance in a model of ischemic myocardium. Techniques using such tissue-engineered cell sheets are introducing the promising concept of tissue cardiomyoplasty to the field of regenerative medicine.

Animals↗

Functional human corneal endothelial cell sheets harvested from temperature-responsive culture surfaces.

This study reports a new method for fabricating bioengineered human corneal endothelial cell sheets suitable for ocular surgery and repair. We have initially cultured human corneal endothelial cells on type IV collagen-coated dishes and, after several passages, expanded cells were then seeded onto novel temperature-responsive culture dishes. Four weeks after reaching confluence, these cultured endothelial cells were harvested as intact monolayer cell sheets by simple temperature reduction without enzymatic treatment. Scanning electron microscopy indicated that these cells were primarily hexagonal with numerous microvilli and cilia, similar to the native corneal endothelium. The Na+, K+-ATPase pump sites were located at the cell borders as in vivo. Moreover, cell densities and numbers of pump sites were identical to those of in vivo human corneal endothelium under optimized conditions. A 3H-ouabain binding analysis demonstrated a linear proportionality for cell pump density between confluent cell densities of 575 cells/mm2 and 3070 cells/mm2. We also confirmed Na+, K+-ATPase activity in the sheets in vitro. Xenograft transplantation results showed that the fabricated sheets retain their function of maintaining proper stromal hydration in vivo. We have established a regimen to culture and proliferate human corneal endothelial cells and fabricate endothelial sheets ex vivo morphologically and functionally similar to the native corneal endothelium. Our results support the value of harvested cell sheets for clinical applications in ocular reconstructive surgery in patients with ocular endothelial decompensation.

Cell Culture Techniques↗

Rapid and highly sensitive detection of cadmium chloride induced cytotoxicity using the HSP70B' promoter in live cells.

One unique to detect cytotoxicity is to utilize reporter gene assays for promoters that respond to stress-induced effects. In the present study, we discovered that the DNA sequence from nt -287 to +110 of the heat shock protein 70B' (HSP70B') gene could be used as a functional promoter to detect cytotoxicity of cadmium chloride. We thus detected cytotoxicity induced by cadmium chloride with the luciferase assay using this functional HSP70B' promoter, as well as the cell viability test based on the quantification of intracellular ATP. The luciferase assay using the functional HSP70B' promoter resulted in nearly maximal luciferase activity after only 12 h of exposure to cadmium chloride, however, with intracellular ATP quantification, the decrease in cell viability only reached a plateau after 24 h of exposure. Cytotoxicity detection limits for cadmium chloride with the functional HSP70B' promoter assay or cell viability based on ATP quantification were 130 ng/mL and 530 ng/mL, respectively. Our results therefore suggest that the novel reporter gene assay using a functional region of the HSP70B' promoter has significant advantages for the detection of cytotoxicity in terms of both speed and sensitivity, when compared to the cell viability test based on ATP quantification.

Biological Assay↗

p57Kip2 is expressed in quiescent mouse bone marrow side population cells.

Hematopoietic stem cells can be accurately identified by the side population (SP) phenotype. It has been previously shown that hematopoietic stem cells are cell cycle arrested, but the mechanisms involved are currently poorly understood. In the present study, results from quantitative real-time RT-PCR show that while SP cells have increased expression of various cyclins and cyclin-dependent kinases, the increased expression of cyclin-dependent kinase inhibitors, in particular p57(Kip2), is responsible for the observed cell cycle arrest. In addition, gene expression analysis of c-kit(+/)/Sca-1(+)/Lineage- SP (KSL-SP) cells demonstrates that only p57(Kip2) shows both higher expression compared to both SP and non-SP cells. Furthermore, immunostaining also demonstrates significantly higher protein expression in KSL-SP cells. These results demonstrate that the maintenance of bone marrow SP cells in G0/G1 may be carefully controlled by p57(Kip2).

Animals↗

Rat limbal epithelial side population cells exhibit a distinct expression of stem cell markers that are lacking in side population cells from the central cornea.

The side population (SP) phenotype is shared by stem cells in various tissues and species. Here we demonstrate SP cells with Hoechst dye efflux were surprisingly collected from the epithelia of both the rat limbus and central cornea, unlike in human and rabbit eyes. Our results show that rat limbal SP cells have a significantly higher expression of the stem cell markers ABCG2, nestin, and notch 1, compared to central corneal SP cells. Immunohistochemistry also revealed that ABCG2 and the epithelial stem/progenitor cell marker p63 were expressed only in basal limbal epithelial cells. These results demonstrate that ABCG2 expression is closely linked to the stem cell phenotype of SP cells.

ATP Binding Cassette Transporter, Subfamily G, Mem↗

Temperature-responsive stationary phase utilizing a polymer of proline derivative for hydrophobic interaction chromatography using an aqueous mobile phase.

A new method of chromatography is proposed, utilizing a thermo-responsive polymer carrying an amino acid ester residue for the stationary phase of high-performance liquid chromatography (HPLC). We have been investigating the new concept of chromatography, a temperature-responsive chromatography, using temperature-responsive poly(N-isopropylacrylamide) (PNIPAAm)-modified surface for HPLC with a constant aqueous media as the mobile phase. In this study, we designed and synthesized thermo-responsive poly(acryloyl-L-proline methyl ester) and its copolymer with N-isopropylacrylamide (NIPAAm). Homopolymers of acryloyl-L-proline methyl ester and copolymer were prepared by the reaction of radical telomerization. These polymers underwent a reversible phase transition from water-soluble forms into aggregates by changing the temperature, similar to PNIPAAm. The surface properties and functions of stationary phases modified with poly(acryloyl-L-proline methyl ester) were controlled by the external temperature. In the chromatographic system, we separated steroids and amino acids with a variety of hydrophobicities using a sole aqueous mobile phase. In contrast to a PNIPAAm-modified surface, a poly(acryloyl-L-proline methyl ester)-modified surface showed a greater affinity for hydrophobic amino acids.

Chromatography, Liquid↗

Limbal epithelial side-population cells have stem cell-like properties, including quiescent state.

Corneal epithelial (CE) stem cells are believed to reside in the basal layer of the limbal epithelium but remain poorly understood due to the lack of an accepted in vivo reconstitution assay as well as definitive markers for epithelial stem cells. It has been reported that side-population (SP) cells with the ability to efflux the DNA-binding dye Hoechst 33342 have stem cell-like properties and that the SP phenotype accurately represents a quiescent and immature stem cell population in the adult bone marrow. In the present study, we investigated whether SP cells isolated from the limbal epithelium have stem cell-like properties. SP cells, separated by fluorescence-activated cell sorting, comprise approximately 0.4% of all limbal epithelial cells and have markedly higher expression of the stem cell markers ABCG2, Bmi-1, and nestin but no expression of markers for differentiated CE cells compared with non-SP cells. Cell-cycle and telomerase activity analyses revealed that SP cells are growth arrested and reside in the quiescent state. Moreover, limbal epithelial SP cells did not demonstrate proliferative capabilities under typical in vitro epithelial cell culture conditions using 3T3 feeder layers. These findings present the possibility that quiescent limbal epithelial SP cells may represent an extremely immature stem cell population compared with currently defined epithelial stem or progenitor cells.

Animals↗

Structural characterization of bioengineered human corneal endothelial cell sheets fabricated on temperature-responsive culture dishes.

For the purpose of corneal regenerative medicine, we fabricated human corneal endothelial cell sheets on temperature-responsive dishes, which could be non-invasively harvested as intact, transplantable sheets by simply reducing the culture temperature. Cells demonstrated hexagonal cell shape with numerous microvilli and cilia, and also exhibited abundant cytoplasmic organelles similar to these cells in vivo. Immunofluorescence for type IV collagen and fibronectin revealed that abundant extracellular matrix (ECM) was deposited on the basal surface throughout culture, and the deposited ECM was harvested along with the cell sheets by reducing culture temperature to 20 degrees C. Faint ECM remnants were observed on the dish surfaces after cell sheet detachment. Immunofluorescence for ZO-1 showed that tight junctions were established between cells, and immunoblotting indicated that intact ZO-1 was maintained during cell sheet harvest, while conventional proteolytic cell harvest methods resulted in the degradation of ZO-1. These results suggest that these transplantable corneal endothelial cell sheets can be applied to treat patients with damaged corneas.

Cell Culture Techniques↗

Analysis of the electrophysiological properties and arrhythmias in directly contacted skeletal and cardiac muscle cell sheets.

OBJECTIVE: Autologous skeletal muscle cell (SM) transplantation into the in vivo heart sometimes induces serious arrhythmias. The purpose of this study was to investigate the electrophysiology of cardiomyocyte (CM) and SM in direct contact and to study the mechanism underlying the cause of arrhythmia using the recently developed cell sheet engineering technique. METHODS: Primary cultured rat neonatal SM and CM were prepared, and cell sheets were fabricated using temperature-responsive culture dishes. The action potential was recorded by a conventional microelectrode. Intracellular calcium concentration and optical mapping image of the action potential were recorded using Fluo-3 and di-4-ANEPPS, respectively. A video motion-detecting system was used for the detection of arrhythmias. RESULTS: SM myotubes occasionally displayed automaticity. SM sheets did not display synchronized contraction, but instead groups of myotubes contracted independently. The action potential of SM, induced by artificial pacing, did not expand to the entire sheet but was limited within a restricted, small area around the electrode, and it was unfeasible to generate an electrical connection or propagate an action potential between CM and SM sheets. SM sheets, in which some of the myotubes displayed automaticity, caused fibrillation-like contraction in the co-cultured CM sheets, and this arrhythmia was specifically blocked by the stretch-activated channel blocker GsMTx-4. CONCLUSIONS: These findings show that SM sheets do not contract synchronously or generate functional syncytia with the surrounding CM sheets and that stretch-induced arrhythmias due to spontaneous contraction of SM may occur in the CM sheet.

Action Potentials↗

Cell culture and life support system for microbioreactor and bioassay.

A microchip-based cell culture system was developed and a primary culture of rat hepatocytes was realized in the system. The microchip was made of glass plates and had a microchannel and a microculture flask inside. The flask inner surface was coated using collagen solution; then FBS and DMEM were added successively. Rat hepatocytes suspended in a medium was introduced into the microchip and incubated at 37 degrees C in a humidified atmosphere with 5% CO(2). Because of the shortage of dissolved oxygen, the cultured cells in the microchip resulted in a significant decrease in viability. To overcome this, a continuous medium flow oxygen and nutrition supplying system was designed and constructed. The system realized good cell growth for at least 4 days. Liver-specific functions, such as the synthesis of albumin and urea from hepatocytes were confirmed.

Albumins↗

Influence of serum and albumins from different species on stability of camptothecin-loaded micelles.

Stability of CPT free drug and CPT-loaded polymeric micelles forming from poly (ethylene glycol)-poly (benzyl aspartate-69) block copolymer in the presence of serum and purified serum albumins were investigated by reverse-phase HPLC and GPC. The hydrolysis of CPT and CPT-loaded micelles follows pseudo-first-order kinetics. The observed hydrolysis rate constants for CPT and CPT-loaded micelles were 7.4x10(-3)min(-1) and 0.7x10(-3)h(-1), corresponding to an increase in half-life of CPT from 94 min to 990 h, respectively. The half-lives of CPT lactone hydrolysis of CPT-loaded micelles in the presence of BSA were significantly longer than the control whereas in the presence of HSA and serum was shorter than the control, and the similar results were obtained from GPC analyzed for micelles stability. This result suggested that the stability of CPT-loaded micelles was significantly decreased only in the presence of human albumin and serum. These were corresponded to the results of CPT free drug observed in the presence of albumins or serum. BSA significantly retarded the CPT lactone ring opening as compared with the control. On the other hand, HSA and serum showed rapid CPT lactone ring opening. This was probably due to preferential HSA binding to the carboxylate form resulting in a change in the lactone-carboxylate equilibrium, whereas, BSA did not bind to the lactone form, but might promote the self-aggregation of CPT and binding to the hydrophobic inner core of the micelles, resulting in enhanced stability of CPT-loaded micelles. MSA did not affect the stability of micelles.

Animals↗

Analysis of herbicides in water using temperature-responsive chromatography and an aqueous mobile phase.

A simple and rapid method has been developed for herbicides in water using temperature-responsive liquid chromatography (LC) and a column packed with poly(N-isopropylacrylamide) (PNIPAAm), a polymer anchored on the stationary-phase surface of modified silica. PNIPAAm reversibly changes its hydrophilic/hydrophobic properties in water in response to temperature. The method was used to determine five sulfonylurea and three urea herbicides. Separation was achieved with a 10 mM ammonium acetate (pH 3.0) isocratic aqueous mobile phase, and by changing the column temperature. The analytes were extracted from water by off-line solid-phase extraction (SPE) with an N-vinyl-pyrrolidone polymer cartridge. The average recoveries of the eight herbicides from spiked pure water, tap water and river water were 70-130% with relative standard deviations (RSDs) of <10%. The limits of quantitation (LOQ) of the eight herbicides were between 1 and 4 microg l(-1).

Acrylic Resins↗

Nanostructured designs of biomedical materials: applications of cell sheet engineering to functional regenerative tissues and organs.

Biomaterials surface design is critical for control of cell-materials interactions. Materials surface characteristics important to cell-materials interactions are the following: (a) nonfouling surfaces where cells cannot interact; (b) surfaces that interact with cells but do not alter cell morphology or metabolism (passive adhesion processes); and (c) surfaces that strongly interact with cells and cell-surface receptors to alter cell shape after metabolic interactions (active adhesion). In this paper, we briefly discuss the relationship between materials surface characteristics and cells for biomaterials designs in these categories. We have extensively investigated the thermoresponsive polymer, poly(N-isopropylacrylamide) (PIPAAm), as grafted surfaces allowing recovery of confluent cell monolayers as contiguous living cell sheets for tissue engineering applications. Cellular interactions with PIPAAm-grafted surfaces can be regulated vertically using the thickness of the PIPAAm-grafted layers in nanometer-scale levels, as well as laterally (spatially) using nano-patterned PIPAAm chemistry on various other surface chemistries. PIPAAm-grafted surfaces with 15-20-nm thick layers exhibit temperature-dependent cell adhesion/detachment control, while surfaces with PIPAAm layer thicknesses of more than 30 nm do not support cell adhesion. These changes in cell adhesion are explained by the limited mobility of the surface grafted polymer chains as a function of grafting, hydration, and temperature.

Animals↗

Biodistribution characteristics of all-trans retinoic acid incorporated in liposomes and polymeric micelles following intravenous administration.

The aim of this study was to investigate the biodistribution characteristics of all-trans retinoic acid (ATRA) incorporated in liposomes and polymeric micelles following intravenous administration. [3H] ATRA were incorporated in distearoylphosphatidylcholine (DSPC)/cholesterol (6:4) liposomes. Two types of block copolymers, poly (ethylene glycol)-b-poly-(aspartic acid) derivatives with benzyl (Bz-75) groups, were synthesized to prepare the polymeric micelles for [(3)H]ATRA incorporation. ATRA were dissolved in mouse serum to analyze their inherent distribution. After intravenous administration, the blood concentration of [3H] ATRA in liposomes and polymeric micelles (Bz-75) was higher than that of inherent [3H]ATRA, suggesting that liposomes and polymeric micelles (Bz-75) control the distribution of ATRA. Pharmacokinetic analysis demonstrated that [3H]ATRA incorporated in polymeric micelles (Bz-75) exhibit the largest AUC(blood) and lowest hepatic clearance of ATRA, suggesting that polymeric micelles (Bz-75) are an effective ATRA carrier system for acute promyelocytic leukemia (APL) therapy. These results have potential implications for the design of ATRA carriers for APL patients.

Animals↗