Search PubMed⌕ Search

Biomedical subjects

Tapio Kotiaho

Publications and source records attributed to Tapio Kotiaho.

27 records · Page 2Linked to original sources

Feasibility of a liquid-phase microextraction sample clean-up and liquid chromatographic/mass spectrometric screening method for selected anabolic steroid glucuronides in biological samples.

Anabolic androgenic steroids (AAS) are metabolized extensively in the human body, resulting mainly in the formation of glucuronide conjugates. Current detection methods for AAS are based on gas chromatographic/mass spectrometric (GC/MS) analysis of the hydrolyzed steroid aglycones. These analyses require laborious sample preparation steps and are therefore time consuming. Our interest was to develop a rapid and straightforward method for intact steroid glucuronides in biological samples, using liquid-phase microextraction (LPME) sample clean-up and concentration method combined with liquid chromatographic/tandem mass spectrometric (LC/MS/MS) analysis. The applicability of LPME was optimized for 13 steroid glucuronides, and compared with conventional liquid-liquid extraction (LLE) and solid-phase extraction (SPE) procedures. An LC/MS/MS method was developed for the quantitative detection of AAS glucuronides, using a deuterium-labeled steroid glucuronide as the internal standard. LPME, owing to its high specificity, was shown to be better suited than conventional LLE and SPE for the clean-up of urinary AAS glucuronides. The LPME/LC/MS/MS method was fast and reliable, offering acceptable reproducibility and linearity with detection limits in the range 2-20 ng ml(-1) for most of the selected AAS glucuronides. The method was successfully applied to in vitro metabolic studies, and also tested with an authentic forensic urine sample. For a urine matrix the method still has some unsolved problems with specificity, which should be overcome before the method can be reliably used for doping analysis, but still offering additional and complementary data for current GC/MS analyses.

Anabolic Agents↗

Introduction to micro-analytical systems: bioanalytical and pharmaceutical applications.

This review presents a brief overview of recent developments in miniaturization of analytical instruments utilizing microfabrication technology. The concept 'Micro-Total Analysis Systems micro-TAS)', also termed 'Lab-on-a-chip', and the latest progresses in the development of microfabricated separation devices and on-chip detection techniques are discussed. Applications of micro-analytical methods to bioanalytical and pharmaceutical studies are also described, including chemical reactions, assays, and analytical separations of biomolecules in micro-scale.

Animals↗

N-in-one permeability studies of heterogeneous sets of compounds across Caco-2 cell monolayers.

PURPOSE: The purpose of the study was to evaluate several n-in-one cocktails of heterogeneous compounds to increase the throughput of permeability studies across Caco-2 monolayers, to investigate the reliability and applicability of the method, and to develop fast and sensitive analysis for the compounds. Compounds with potential interactions in efflux and/or active transport were chosen. METHODS: Permeability experiments with verapamil, propranolol, midazolam, hydroxyzine, timolol, buspirone, procaine, naproxen, ketoprofen, and antipyrine as single compounds and in cocktails of 5-10 compounds were performed at 50 microM concentration both in the apical-to-basolateral and basolateral-to-apical direction. The compounds were quantified by liquid chromatography-electrospray tandem mass spectrometry (LC-ESI/MS/MS). Toxicity tests were performed to determine cellular damage. RESULTS: The analytical method was sensitive, accurate, and rapid. The individual permeabilities of compounds in cocktails correlated well with permeabilities as single compounds. No significant interactions between the compounds within the mixtures were observed, except for acidic compounds. The studied mixtures did not show any toxicity. CONCLUSIONS: The use of n-in-one cocktails is a suitable method to improve the capacity in routine permeability experiments and higher throughput screening of drug candidates, although potential interactions should always be borne in mind. The use of LC-ESI/MS/MS technology provides an excellent tool in fast and accurate analysis of small amounts of heterogeneous compounds.

Biological Transport↗

Analysis of catecholamines by capillary electrophoresis and capillary electrophoresis-nanospray mass spectrometry. Use of aqueous and non-aqueous solutions compared with physical parameters.

Catecholamines were analysed in aqueous and alcoholic non-aqueous solutions by capillary electrophoresis and capillary electrophoresis-mass spectrometry using sheathless nanospray coupling. Decreases in the electrophoretic mobilities of the catecholamines and in the electroosmotic mobilities were observed from water to 1-propanol. Separations were more efficient in all non-aqueous media than in water. The diffusion coefficients of the catecholamines in the different media were determined. The solvent had little effect on the sensitivity of the UV or MS detection. Both methods were successfully applied to the analysis of urine samples.

Catecholamines↗

Atmospheric pressure photoionization mass spectrometry. Ionization mechanism and the effect of solvent on the ionization of naphthalenes.

The ionization mechanism in dopant-assisted atmospheric pressure photoionization and the effect of solvent on the ionization efficiency was studied using 7 naphthalenes and 13 different solvent systems. The ionization efficiency was 1-2 orders of magnitude higher with dopant than without, indicating that the photoionization of the dopant initiates the ionization process. In positive ion mode, the analytes were ionized either by charge exchange or by proton transfer. Charge exchange was favored for low proton affinity solvents (water, hexane, chloroform), whereas the addition of methanol or acetonitrile to the solvent initiated proton transfer. In negative ion mode, the compounds with high electron affinity were ionized by electron capture or by charge exchange and the compounds with high gas-phase acidity were ionized by proton transfer. In addition, some oxidation reactions were observed. All the reactions leading to ionization of analytes in negative ion mode are initiated by thermal electrons formed in photoionization of toluene. The testing of different solvents showed that addition of buffers such as ammonium acetate, ammonium hydroxide, or acetic acid may suppress ionization in APPI. The reactions are discussed in detail in light of thermodynamic data.

Atmospheric Pressure↗

Electrospray ionization mass spectrometry and tandem mass spectrometry of clodronate and related bisphosphonate and phosphonate compounds.

The bisphosphonate family with a P-C-P structure is a broad class of drugs, widely investigated as potential inhibitors in bone diseases and calcium metabolic disorders. In this study, the mass spectrometric (MS) behavior and fragmentation of clodronate and related bisphosphonate and phosphonate compounds was studied by using negative ion electrospray ionization (ESI) with triple quadrupole and ion trap instruments. The effect of pH on the degree of deprotonation of the polyprotic bisphosphonic and phosphonic acids in negative ion ESI-MS was investigated, and the degree of deprotonation in the ESI mass spectra and the dissociation in the liquid phase were compared. The results provide evidence that the measured ESI mass spectra do not correlate with the chemistry in the liquid phase owing to the decrease in the pH of the solvent droplets during the ion evaporation process and the charge state neutralization in the gas phase. Ion trap MS(n) provided useful information on the fragmentation study of clodronate and related bisphosphonate and phosphonate compounds, in which interesting fragmentation pathways including the direct elimination of carbon monoxide from deprotonated bisphosphonates and formation of a P-P bond were observed. Reactions between the product ions with a -PO(2) group and residual water in the ion trap or in the high-pressure region of the triple quadrupole instrument formed other unexpected fragmentation paths for all the bisphosphonates studied.

Antimetabolites↗

Environmental applications of membrane introduction mass spectrometry.

The purpose of this review is to highlight the versatility of membrane introduction mass spectrometry (MIMS) in environmental applications, summarize the measurements of environmental volatile organic compounds (VOCs) accomplished using MIMS, present developments in the detection of semi-volatile organic compounds (SVOCs) and forecast possible future directions of MIMS in environmental applications.

Air Pollutants↗

Effects of nebulizing and drying gas flow on capillary electrophoresis/mass spectrometry.

This study was focused on examining the influence of gas flow parameters on capillary electrophoresis/mass spectrometry (CE /MS) performance using sheath-liquid CE /MS interfaces. The effects of nebulizing and drying gas velocity and drying gas temperature on CE separation and MS detection sensitivity were systematically determined. Nebulizing gas velocity was observed to be a critical parameter in the optimization of CE /MS method, since it affected both MS detection sensitivity, and also CE separation efficiency for one interface design tested. Better detection sensitivity was obtained when the nebulizing gas velocity was increased. However, high velocity of the nebulizing gas flow can cause a hydrodynamic bulk flow inside the CE capillary, thus clearly increasing the apparent mobility and decreasing the resolution obtained for the compounds studied. Increasing the drying gas velocity or temperature did not affect the apparent mobility or the separation efficiency and the temperature could be increased to achieve the optimal detection sensitivity in the CE /MS analysis. For comparison, the effects of nebulizing gas flow were studied using a different design of the coaxial sheath-liquid CE /MS interface, and in this case better detection sensitivity but no effect on CE separation efficiency was observed with increased nebulizing gas velocity. These different effects of nebulizing gas flow on the CE bulk flow were concluded to result from pressure differences at the tip of the CE capillaries for the different CE /MS interface arrangements. It is therefore recommended that the cross-sectional dimensions of the fused-silica and steel capillaries, and the gas streamlines, should be optimized when CE /MS interfaces are built. Moreover, the effect of gas flow on CE separation should be studied when optimizing the CE /MS operation parameters.

Buprenorphine↗