Repair of osteochondral defects with grafts of cultured chondrocytes. Comparison of allografts and isografts.

Isogeneic and allogeneic chondrocytes cultured in collagen gel were transplanted into osteochondral defects in knee joints of inbred strains of rats. At 12 weeks, all eight isografted defects had healed successfully, compared with only four of eight allografted defects (p < 0.05). At 26 and 52 weeks, all defects except one had healed successfully and there was no significant difference in the success rate between the isografted and allografted groups. Control defects that had been implanted with only collagen gel did not heal successfully.

Animals↗

[Postlaminectomy kyphosis of the cervical spine complicating spinal cord tumor in the foramen magnum].

Postlaminectomy kyphosis is rarely encountered as a sequela of decompression of the upper cervical spine, especially in adults. We present a case of disabling cervical kyphosis which developed after laminectomy for excision of a foramen magnum tumor and was treated successfully by occipito-vertebral fusion. A sixty-one-year old female was treated by laminectomy of the first through to the third cervical spine for a foramen magnum meningioma. One year later, the laminectomy was extended downward to include the fourth through to the seventh cervical spine because of neurological deterioration. Seven years after the first laminectomy, she was referred to our spinal service because of severe neck pain, numbness and muscle weakness of both upper extremities. Lateral X-ray of her cervical spine presented a severe kyphosis. Roentgenogram two months after the first laminectomy already showed slight deformity and, timewise, it corresponded with the time when the patient experienced neurological deterioration. Subsequent X-rays showed progression of kyphosis. After we confirmed a lessening of the pain and improvement of the neurological symptoms during an axial traction using a halo-vest, posterior occipito-cervico-thoracic fusion was performed using Luque segmental spinal instrumentation and autogenous bone graft. After surgery the pain decreased and neurological symptoms improved. It is important to be aware of the complication of kyphotic deformity after laminectomy and once it has developed, it is recommended to stabilize the progression by early spinal fusion.

Cervical Vertebrae↗

Ovariectomy decreases the mRNA levels of transforming growth factor-beta 1 and increases the mRNA levels of osteocalcin in rat bone in vivo.

Estrogen depletion causes postmenopausal osteoporosis. Here we report that steady state mRNA levels of transforming growth factor-beta 1 (TGF-beta 1) and osteocalcin in bone persistently decreased and increased, respectively, in vivo in estrogen-depleted rats after ovariectomy (OVX). 21 female Wistar rats (7-month-old) were randomized and underwent OVX or sham-operation, total RNA was extracted from tibiae and assessed by Northern blot analysis. OVX induced 70-80% decrease in TGF-beta 1 mRNA levels and 2- to 3-fold increase in mRNA levels of osteocalcin compared with controls three weeks after surgery. These changes persisted up to twelve weeks post-operation. OVX caused 15% reduction in femoral bone mineral density and 2-fold elevation in serum osteocalcin levels as early as two weeks post-operation. Moreover, estrogen depletion resulted in marked decrease and increase, respectively, in steady state mRNA levels of TGF-beta 1 and osteocalcin in vitro in osteoblastic rat osteosarcoma cells, ROS 17/2.8. Our results provide the first in vivo evidence that expression of TGF-beta and osteocalcin in bone is reciprocally regulated at the transcriptional level in estrogen deficient OVX rats and suggests that TGF-beta 1 may play a role in estrogen-dependent maintenance of normal bone density.

Amino Acid Isomerases↗

A study of the bioactive bone cement--bone interface: quantitative and histological evaluation.

The interface between bone and a bioactive glass cement--a mixture of bioactive glass powder and ammonium phosphate solution, previously reported on by the authors--was evaluated quantitatively and histologically. The materials tested were (1) the original bioactive glass cement (BCI cement); (2) an improved type of bioactive glass cement (BCII cement); (3) polymethylmethacrylate (PMMA) bone cement; and (4) a bioactive, apatite-wollastonite-containing, glass ceramic (A-WGC). Hardened cylindrical specimens of each cement were inserted loosely into canine femora and the interfacial shear strengths were measured using a push-out test. The interfacial strength values of the bioactive glass cements increased with prolonged implantation time. At each postimplantation time studied (8, 12, and 24 weeks), the interfacial strength value of BCI cement did not differ significantly from that of A-WGC. BCII cement interfacial strength was greater than that of BCI cement, whereas the interfacial strength of PMMA bone cement remained at a very low level throughout the study. Histological examinations revealed that direct bonding of both bioactive glass cements to bone had occurred without pathologic degradation. After 24 weeks, the defects between the bone and the bioactive glass cements had been filled with mature lamellar bone. Because the bioactive glass cement system developed by the authors, especially BCII cement, shows excellent osteoconductivity and bonds to bone tightly, we consider it to be a promising material for fixing prostheses into bone.

Animals↗

A new bioactive bone cement consisting of BIS-GMA resin and bioactive glass powder.

We have developed a bioactive bone cement consisting of silane-treated CaO-SiO 2-P 2O 5-CaF 2 glass powder as the filling particles and bisphenol-a-glycidyl methacrylate (BIS-GMA) diluted with triethylene-glycol dimethacrylate (TEGDMA) as the organic matrix. Histological examination demonstrated direct bonding between the cement and bone along the circumference of the cement at 4 weeks after implantation in rat tibia. The compressive strength and toughness of the cement were two and four times greater than those of polymethylmethacrylate (PMMA) cement, respectively. The inflammatory reaction of the skin caused by the new cement was not as intense as that for PMMA 3 days after subcutaneous implantation. This new cement may be applicable as a bioactive bone cement with high mechanical strength.

Animals↗

Effects of ions in aqueous media on hydroxyapatite induction by silica gel and its relevance to bioactivity of bioactive glasses and glass-ceramics.

Hydroxyapatite induction by a synthesized pure silica hydrogel was examined in various simulated body fluids (SBFs) having different magnesium, calcium, and phosphate ion concentrations as well as pH values. The silica hydrogel generated biologically active apatite on its surface by taking up calcium and phosphorous ionic groups from a surrounding SBF that was prepared to emulate the human plasma in inorganic composition. The induction period for apatite nucleation on the surface of the silica was largely decreased with the addition of a small amount of the calcium or phosphate ions to the SBF and with an increase in pH, but increased with the addition of magnesium ion. Bioactivity of bioactive materials like Bioglass and glass-ceramic A-W was well interpreted in terms of the rate of apatite formation reflected in these results. Moreover, the results provide the basic knowledge for designing new bioactive materials.

Biocompatible Materials↗

A new bioactive glass--ceramic as a coating material on titanium alloy.

Apatite--wollastonite-containing glass--ceramic (A--W . GC) has a strong ability to bond to bone and relatively high mechanical strength. Therefore, as a bulk material it has recently been applied clinically even in load-bearing sites. In this study, we modified A--W . GC by altering its composition ratio with the removal of CaF 2 and the addition of B 2O 3, and examined the potential use of the resulting new glass--ceramic as a material for coating on a titanium (Ti) alloy. The bioactivity of this new coating (NC) material and its bonding ability to bone were investigated mechanically and histologically. After implantation of the Ti alloy plate coated with this material into the tibiae of rabbits for 2, 3, 4, 8, and 25 weeks, a detaching test was performed. The detaching failure load of the NC plates was compared with those of A--W . GC plates, hydroxyapatite (HA) plates, and uncoated Ti alloy plates implanted in the same way. The failure load of NC was as high as that of A--W . GC for all periods, whereas it was significantly higher at 3 and 4 weeks than that of HA. Uncoated Ti alloy showed lower failure loads for all periods, differing significantly from the other materials. There was no breakage or detachment of the coating layer observed after the detaching test. Histological examinations by CMR, Giemsa surface staining, and SEM-EPMA showed that NC bonded directly to bone without any intervening soft tissue layer. A calcium--phosphorus-rich layer (apatite layer) was observed within the coating layer, as is the case in A--W . GC. These results indicate that this new glass--ceramic has earlier bone-bonding ability and high mechanical strength, making it a promising coating material.

Animals↗

Time-dependent changes in the mechanical properties of zirconia ceramic.

Zirconia has received special attention, mainly because of its high strength and toughness. However, there is some controversy about the time-dependent deterioration of its mechanical properties. To examine the change in mechanical properties of zirconia ceramics in vivo and in vitro, tetragonal zirconia polycrystal pieces were introduced into the medullary cavity of the tibia in Japanese rabbits and animals were sacrificed after 2, 4 and 6 weeks and 6, 12, and 30 mo, respectively. Alumina ceramic and hydroxyapatite (HAP) pieces were used as controls to investigate the differences in biocompatibility. Zirconia showed a bending strength of over 1000 MPa initially, and little time-dependent change in strength was found in both in vivo and in vitro environments. x-Ray analysis showed little change in the transformation rate, i.e., less than 5 mol % in vivo and in vitro over a period of 3 years. To estimate time-dependent changes in zirconia over a longer period, zirconia pieces were placed in 95 degrees C saline solution for over 3 years and their mechanical properties examined at chosen intervals. No serious decrease of bending strength was found over the 3-year period under these conditions. It is concluded that zirconia can be used clinically because it retains a bending strength of over 700 MPa under any experimental conditions for over 3 years.

Animals↗

Apatite formation on three kinds of bioactive material at an early stage in vivo: a comparative study by transmission electron microscopy.

Apatite formation on the surface of three kinds of bioactive material at an early stage after implantation in bone was studied using transmission electron microscopy (TEM). The materials were apatite- and wollastonite-containing glass-ceramic (A-W GC) as a surface-active glass-ceramic, dense sintered hydroxyapatite (HA) as a surface-active ceramic, and dense sintered beta-tricalcium phosphate (beta-TCP) as a resorbable ceramic. Particles of these materials, ranging from 100-300 microns in diameter, were implanted into rat tibiae, and specimens were prepared at 3, 7, 10, and 14 days after implantation. For A-W GC, dissolution of the glassy and probably wollastonite phase was observed in the surface region on and after the third day, and a collagen-free thin apatite layer on the surface of the material was evident on and after the seventh day. This apatite layer was observed before the mineralization of the surrounding bone matrix and was sometimes evident even where the material bordered on the bone marrow. On and after the tenth day, the surrounding bone matrix calcified and A-W GC-bone bonding through an apatite layer was completed. For HA, a mineralized collagen-free layer was observed on the surface of the ceramic on and after the tenth day. This layer was always present near calcifying bone and it was difficult to distinguish from immature bone. For beta-TCP, such a surface mineralized layer was rarely evident, even just before bone-ceramic contact, and finally the bone bonded to beta-TCP directly. Cell-mediated degradation of beta-TCP was frequently observed.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Localized hyperthermic treatment of experimental bone tumors with ferromagnetic ceramics.

Localized hyperthermic treatment was carried out with use of a metastatic bone tumor model in rabbits. The experimental bone tumor was created by transplantation of pieces of tumor line VX2 into the medullary canal of rabbit tibiae. Two weeks after the transplantation, a ferromagnetic ceramic pin was inserted in the medullary canal. Then, hyperthermia (HT) of the tumor was accomplished with use of an alternating magnetic field for 50 min. All the rabbits were killed 5 weeks after tumor transplantation, and the therapeutic effect was evaluated histologically and roentgenographically. Almost all the tumor cells within the bone marrow were killed by this procedure. The area of tumor necrosis in the HT group was significantly larger than in the control group. The pathological fracture rate and displacement rate were reduced significantly by this treatment (38.5 and 0%) compared with the controls (92.3 and 92.3%). Therefore, HT with the use of ferromagnetic ceramics was effective for local control of malignant bone tumors and seems to be a promising new method of treatment.

Animals↗

Influence of disodium (1-hydroxythylidene) diphosphonate on bonding between glass-ceramics containing apatite and wollastonite and mature male rabbit bone.

It has been reported that bioactive glass-ceramics containing crystalline oxy- and fluoroapatite [Ca10(PO4)6(O,F2) and wollastonite (CaSiO3), chemical composition: MgO 4.6, CaO 44.9, SiO2 34.2, P2O5 16.3, CaF2 0.5 in weight ratio] bond to bone tissue through the formation of an apatite (a calcium and phosphorus-rich layer) on the ceramic surface. In this study, the influence of disodium (1-hydroxythylidene) diphosphonate (DHTD) on the bonding between bone and glass-ceramics containing apatite and wollastonite was investigated. Rectangular ceramic plates (15 mm x 10 mm x 2 mm, abraded with #2000 alumina powder) were implanted into the tibial bone of mature male rabbits. DHTD was administered daily by subcutaneous injection to groups 1-5: group 1-4 at doses of 20, 5.0, 1.0, and 0.1 mg/kg body wt/day for 8 weeks; and group 5 at a dose of 5 mg/kg body wt/day for 4 weeks. Group 6 was given injections of saline as a control. At 8 weeks after implantation, the rabbits were killed. The tibiae containing the ceramics were dissected out and used for a detachment test. The failure load, when an implant became detached from the bone, or when the bone itself broke, was measured. The failure loads for groups 1-6 were 0 kg, 0 kg, 8.08 +/- 2.43 kg, 7.28 +/- 2.07 kg, 5.56 +/- 1.63 kg, and 6.38 +/- 1.30 kg, respectively. Ceramic bonding to bone tissue was inhibited by a higher dose of DHTD (groups 1 and 2).(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Electron microscopy of calcification during high-density suspension culture of chondrocytes.

Chondrocyte cultures grown in centrifuge tubes with intermittent centrifugation differentiate into hypertrophic chondrocytes and form calcification. We examined chondrocytes cultured in this system electron microscopically. Rat growth-plate chondrocytes were seeded in a plastic centrifuge tube and cultured in the presence of Eagle's minimum essential medium supplemented with 10% fetal bovine serum and 50 micrograms of ascorbic acid per ml. Specimens were examined by using electron microscopy and selected-area electron-diffraction techniques. In the early stage of culture, a few chondrocytes were scattered and extracellular matrices were not observed. In the middle stage of the cultures, the chondrocytes resembled proliferative cells. Matrix vesicles appeared to be budding from the cell surfaces of chondrocytes and were observed sparsely in the extracellular matrices, which were well formed around the chondrocytes. Matrix vesicles increased substantially during the following cultures. In the mature stage of the cultures, crystal formation related to matrix vesicles was observed. In the 33-day cultures, several masses of calcified matrix were formed and it was confirmed to be apatite by selected-area electron diffraction analysis. The chondrocytes appeared hypertrophic during this same stage. The 56-day culture was similar to the 33-day culture. It was concluded that this culture system provides an extracellular-matrix mineralization which is produced by chondrocytes per se.

Aging↗

Effects of a highly selective plasma kallikrein inhibitor on collagen-induced arthritis in mice.

A study was conducted to evaluate the effects of a new, highly selective plasma kallikrein inhibitor, PKSI-527, on collagen-induced arthritis (CIA) in mice. PKSI-527 or indomethacin was administered daily intraperitoneally from day 20 postimmunization. Clinical evaluation was performed, and two of the components of the kallikrein-kinin system, high-molecular-weight (HMW) kininogen and plasma prekallikrein, were assayed. PKSI-527, as well as indomethacin, reduced the severity of arthritis significantly. PKSI-527, but not indomethacin, restored consumed components of the kallikrein-kinin system. These results suggest that PKSI-527 suppresses CIA by modifying the kallikrein-kinin system and PKSI-527 as a synthetic plasma kallikrein inhibitor would be a valuable tool to study the mechanism of inflammation of arthritic diseases.

Animals↗

Four calcium phosphate ceramics as bone substitutes for non-weight-bearing.

Calcium phosphate ceramics, beta-calcium pyrophosphate (Ca2P2O7), beta-tricalcium phosphate (Ca3(PO4)2), hydroxyapatite (Ca10(PO4)6(OH)2) and tetracalcium phosphate (Ca4(PO4)2O), were prepared. The calcium:phosphorus ratios and microporosities were 1 (31.6%), 1.5 (1.6%), 1.66 (1%) and 2 (34.6%) respectively. Samples (15 mm x 10 mm x 2 mm), abraded with No. 2000 alumina powder, were implanted into the tibial metaphysis of mature male rabbits. Failure load, when an implant detached from the bone or the bone itself broke, was measured. At 10 wk after implantation, the failure loads in beta-calcium pyrophosphate, beta-tricalcium phosphate, hydroxyapatite and tetracalcium phosphate were 31.65 +/- 9.90 N, 72.81 +/- 19.01 N, 49.49 +/- 17.25 N and 43.22 +/- 14.99 N respectively. At 25 wk after implantation, the values were 47.04 +/- 14.90 N, 71.34 +/- 19.50 N, 69.09 +/- 16.17 N and 62.03 +/- 18.62 N respectively. Histologically, bone bonding behaviour of calcium phosphate ceramics did not vary with the calcium:phosphorus ratio, as observed by contact microradiogram, Giemsa surface staining and scanning electron micrograph-electron probe micro analysis. There was no intervening soft tissue at the interface of bone and ceramics. Hydroxyapatite or tricalcium phosphate are used as bone substitutes. However, their mechanical strength is insufficient for weight-bearing and they are used as bone filler. This study showed that the apparent insignificance of strict calcium:phosphorus ratio with respect to the biological results greatly simplifies processing of calcium phosphate ceramics for clinical application. In clinical application, calcium phosphate ceramics with different Ca:P can be used as bone fillers for bone defects or bone cavities under non-weight-bearing conditions.

Animals↗

The application of titanium alloy wires for the reattachment of the greater trochanter in total hip arthroplasty.

We developed a new fixing method using titanium alloy wires in order to facilitate the attachment of the greater trochanter in total hip arthroplasty. This wire is composed of Ti-3Al-2.5V by weight. According to the fatigue test in vitro, the titanium alloy wire had better fatigue properties than Ortron 90 wire of the same diameter. In experiments in vivo, both titanium alloy wires and SUS-316L wires were used for the reattachment of the greater trochanter of dogs, and the titanium alloy wires showed better biocompatibility than the latter. Thus, titanium alloy wires seem applicable for the reattachment of the greater trochanter in human total hip arthroplasty.