Electrospray device for coupling microscale separations and other miniaturized devices with electrospray mass spectrometry.

A miniaturized ion sprayer device is described which is suitable for coupling with chip-based analytical separation devices, multiwell plates, or surfaces containing residues of prepared samples. Two versions of a similar device are described. A "microsprayer" device suitable for coupling to the terminal edge of a capillary electrophoresis (CE) chip is constructed from modified 1/16-in. HPLC fittings. This microsprayer employs a free-standing liquid junction formed via continuous delivery of a flow (2-6 microL/min) of suitable solvent which carries the CE effluent through a pneumatically assisted electrospray (ion spray) needle positioned in front of an atmospheric pressure ionization (API) mass spectrometer. A related but larger "minisprayer" device is also described which employs the same features as the microsprayer, but with an extended sampling capillary tube which can reach into the depths of 96-, 384-, and 1536-multiwell plates containing either sample solutions or dried sample residues. The minisprayer may be positioned in front of an API ion sampling orifice and the multiwell plate positioned stepwise from sample to sample for analysis of trace samples contained in the wells. The resulting infusion-ion spray mass spectrometric analyses can provide sequential analysis of previously prepared biological samples containing small drug compounds, proteins, and related compounds. This same device is also shown to be useful for sampling from a surface containing trace level compounds of biological interest. Results are shown that demonstrate microscale separations and selected ion monitoring (SIM) capillary electrophoresis/mass spectrometry (CE/MS) detection of berberine and palmatine using the microsprayer. SIM ion spray determination of a 2 ng/microL solution of berberine contained as a dry residue in the bottom of a 384-well plate as well as full-scan electrospray mass spectra for low-picomole levels of cytochrome c contained in a 1536-well microtiter plate are shown. The respective micro- and minisprayer devices provide a simple yet effective means of transferring trace-level samples either from a microscale or chip-based separation device as well as samples contained in multiwell plates which are increasingly employed in high-throughput applications in the pharmaceutical industry.

Journal Article↗

High-throughput bioanalytical LC/MS/MS determination of benzodiazepines in human urine: 1000 samples per 12 hours.

The analytical capabilities of liquid chromatography tandem mass spectrometry for sensitive and highly selective determination of target compounds in complex biological samples makes it well suited for high-throughput analysis. We report the fast separation of six benzodiazepines isolated from human urine via selected reaction monitoring liquid chromatography/mass spectrometry using short dwell times to accommodate fast-eluting chromatographic peaks. The analytes were extracted from human urine samples along with their deuterium-labeled internal standards by a simple liquid-liquid extraction in 96-well plates. Using four autosamplers coupled to one chromatographic column and one tandem mass spectrometer operated in the turbo ion spray mode with positive ion detection, 1152 samples (12 96-well plates) were analyzed in less than 12 h. Through an electronic switching box designed and constructed in-house, the autosamplers were synchronized with the mass spectrometer so that injections were made as soon as the mass spectrometer was ready to collect data. Each run required 30 s to complete with another 7-8 s for the data system to load the next data file to be collected. Chromatographic integrity and ion current response remained relatively constant for the duration of the analyses. The results show acceptable precision and accuracy and demonstrate the feasibility of using fast separations with tandem mass spectrometry for high-throughout analysis of biological samples containing multiple analytes.

Benzodiazepines↗

Quantitative ionspray liquid chromatographic/tandem mass spectrometric determination of reserpine in equine plasma.

A method based on ionspray liquid chromatography/tandem mass spectrometry (LC/MS/MS) was developed for the determination of reserpine in equine plasma. A comparison was made of the isolation of reserpine from plasma by liquid-liquid extraction and by solid-phase extraction. A structural analog, rescinnamine, was used as the internal standard. The reconstituted extracts were analyzed by ionspray LC/MS/MS in the selected reaction monitoring (SRM) mode. The calibration graph for reserpine extracted from equine plasma obtained using liquid-liquid extraction was linear from 10 to 5000 pg ml-1 and that using solid-phase extraction from 100 to 5000 pg ml-1. The lower level of quantitation (LLQ) using liquid-liquid and solid-phase extraction was 50 and 200 pg ml-1, respectively. The lower level of detection for reserpine by LC/MS/MS was 10 pg ml-1. The intra-assay accuracy did not exceed 13% for liquid-liquid and 12% for solid-phase extraction. The recoveries for the LLQ were 68% for liquid-liquid and 58% for solid-phase extraction.

Animals↗

Design and applications of a self-aligning liquid junction-electrospray interface for capillary electrophoresis-mass spectrometry.

A simple self-aligning liquid junction-electrospray interface for coupling a capillary electrophoresis (CE) system to an atmospheric pressure ionization (API) mass spectrometer (CE-MS) was developed. In contrast to previous liquid junction interfaces, the self-aligning liquid junction interface simplifies the precise alignment of the CE capillary and the sprayer needle and uses a positive make-up flow. Several capillary CE-MS applications were run using both the self-aligning liquid junction interface and the widely used sheath flow interface for comparison purposes. The electrospray stability of the self-aligning liquid junction interface is consistently better even when non-volatile electrolyte solutions are used. At first, some band broadening was obtained with the self-aligning liquid junction interface. Experiments with different CE buffer systems suggested that this band broadening was caused by the materials used in constructing the interface. By using a more inert material for the sprayer needle, the self-aligning liquid junction exhibits excellent electrophoretic resolution, comparable sensitivity, and higher signal-to-noise ratios when run under the same conditions as the sheath flow interface.

Adrenergic beta-Agonists↗

Kinetic monitoring of enzymatic reactions in real time by quantitative high-performance liquid chromatography-mass spectrometry.

The study of enzyme kinetics under steady-state conditions represents a common and very useful method for investigating the mechanisms of enzymatic reactions. We report the use of mass spectrometry (MS) coupled with HPLC for the kinetic analysis of enzymatic reactions in real time. The hydrolysis of dinucleotides with bovine pancreatic ribonuclease A (RNase A) and the substrate-specific hydrolysis of lactose with beta-galactosidase can be monitored using ion-spray (pneumatically assisted electrospray) mass spectrometry as a sensitive and specific detector for the native substrates. The resulting data can be used to calculate both KM and Vmax for each system. Kinetic parameters obtained for RNase A and beta-galactosidase paralleled those obtained by conventional techniques. These findings suggest the possibility of developing alternative techniques, based on mass spectrometric detection, for performing kinetic analyses of enzymatic processes where no simple spectrophotometric assay is feasible. In addition to enabling the determination of kinetic parameters for authentic substrates, and not chromogenic analogs, such assays would also be useful in situations where very high sensitivity and specificity are desired.

Animals↗

Recent developments in electrospray mass spectrometry including implementation on an ion trap.

Mass spectrometry (MS) may be the ultimate detection technique when combined with modern condensed phase separation sciences. The technique combines sensitivity with excellent specificity, so the pharmaceutical analyst can obtain definitive information regarding components separated in a mixture. Thus, mass spectrometric detection not only provides evidence of a chromatographic peak, but it also provides important information including molecular weight and structural information enabling identification of the components. The coupling of an atmospheric pressure ionization (API) mass spectrometer to most of the separation science techniques offers a simpler alternative from earlier non-routine, less sensitive systems where the vacuum systems struggled to handle the liquid effluent from these systems. Contemporary sensitive and analytically rugged API systems can be operated unattended for extended periods of time thus reducing the cost per sample to a reasonable value especially given the wealth of information provided. Although the mass spectrometer is more complicated than conventional spectroscopic detectors, present day API systems effectively decouple the liquid-phase separation inlet from the high-vacuum system where mass analysis occurs. The ability to form gas-phase ions at atmospheric pressure and sample primarily the analyte ions into the mass spectrometer promises a bright future for combining on-line condensed phase separation science techniques with mass spectrometry. The increasing ease of performing these experiments offers new analytical opportunities for pharmaceutical laboratories.

Carbohydrate Sequence↗

Urokinase administration in pediatric patients with occluded central venous catheters.

The effectiveness of urokinase in declotting central venous catheters was retrospectively assessed in a pediatric population of 63 patients ranging in age from 4 days to 22 years (mean, 6.4 years). Results of treatment from 103 episodes of catheter occlusion were evaluated. Urokinase was instilled into occluded single-lumen catheters and into each lumen of double-lumen catheters, as well as into occluded implanted ports. Patency was restored to 101 of 103 occluded catheters, with no side effects observed subsequent to clearance of the catheters with the urokinase infusion. Significant cost savings were seen using urokinase to restore patency as compared to the cost of replacing the catheter. These data clearly support the use of urokinase in a pediatric population as a safe and cost-effective alternative to catheter replacement in cases of thrombotic occlusion.

Adolescent↗