Search PubMed⌕ Search

Biomedical subjects

T W Secomb

Publications and source records attributed to T W Secomb.

At least 37 records · Page 2Linked to original sources

The endothelial surface layer.

The endothelial lining of blood vessels presents a large surface area for exchange of materials between blood and tissues, and is critically involved in many other processes such as regulation of blood flow, inflammatory responses and blood coagulation. It has long been known that the luminal surface of the endothelium is lined with a glycocalyx, a layer of membrane-bound macromolecules which has been determined by electron microscopy to be several tens of nanometers thick. However, investigations in vivo have indicated the presence of a much thicker endothelial surface layer (ESL), with an estimated thickness ranging from 0.5 microm to over 1 microm, that restricts the flow of plasma and can exclude red blood cells and some macromolecular solutes. The evidence for the existence of the ESL, hypotheses about its composition and biophysical properties, its relevance to physiological processes, and its possible clinical implications are considered in this review.

Animals↗

Microcirculatory network structures and models.

Terminal vascular beds exhibit a high degree of heterogeneity. Pertinent parameters are nonlinearly related, and their distributions are not independent. The classical "typical vessel" approach using averaged values for different vessel classes may not lead to a correct understanding of physiology and pathophysiology of terminal vascular beds. Such problems can be avoided by studying microcirculatory functions at the network level using a combination of experiments and theoretical models. In this approach, distributions and relationships of pertinent parameters are measured in vivo, leading to the development of comprehensive databases. Such databases can be analyzed and complemented by suitable mathematical models, permitting estimation of parameters that are difficult to measure, and critical assessment of quantitative theories and hypotheses for microvascular function. This collaborative process between experimentally and theoretically oriented investigators may be facilitated in the future by the development of web-based repositories of experimental data and theoretical models.

Adaptation, Physiological↗

Theoretical simulation of oxygen transport to brain by networks of microvessels: effects of oxygen supply and demand on tissue hypoxia.

OBJECTIVE: Simulations of oxygen delivery by a three-dimensional network of microvessels in rat cerebral cortex were used to examine how the distribution of partial pressure of oxygen (PO2) in tissue depends on blood flow and oxygen consumption rates. METHODS: Network geometry was deduced from previously published scanning electron micrographs of corrosion casts. A nonlinear least-squares method, using images obtained at three different angles, was used to estimate vessel locations. The network consisted of 50 segments in a region 140 microm x 150 microm x 160 microm. A Green's function method was used to predict the PO2 distribution. Effects of varying perfusion and consumption were examined, relative to a control state with consumption 10 cm3O2/100 g per min and perfusion 160 cm3/100 g per min. RESULTS: In the control state, minimum tissue PO2, was 7 mm Hg. A Krogh-type model with the same density of vessels, but with uniform spacing, predicted a minimum tissue PO2 of 23 mm Hg. For perfusion below 60% of control, tissue hypoxia (PO2 <1 mm Hg) was predicted. When perfusion was reduced by 75%, the resulting hypoxia could be eliminated by a 31% reduction in oxygen consumption rate. CONCLUSIONS: The simulations suggest that tissue hypoxia resulting from a severe decrease in brain perfusion, as can occur in stroke, may be avoided by a moderate decrease in oxygen consumption rate.

Animals↗

The effects of hyperoxic and hypercarbic gases on tumour blood flow.

Carbogen (95% O2 and 5% CO2) has been used in preference to 100% oxygen (O2) as a radiosensitizer, because it is believed that CO2 blocks O2-induced vasoconstriction. However, recent work suggests that both normal and tumour arterioles of dorsal flap window chambers exhibit the opposite: no vasoconstriction vs constriction for O2 vs carbogen breathing respectively. We hypothesized that CO2 content might cause vasoconstriction and investigated the effects of three O2-CO2 breathing mixtures on tumour arteriolar diameter (TAD) and blood flow (TBF). Fischer 344 rats with R3230Ac tumours transplanted into window chambers breathed either 1%, 5%, or 10% CO2 + O2. Intravital microscopy and laser Doppler flowmetry were used to measure TAD and TBF respectively. Animals breathing 1% CO2 had increased mean arterial pressure (MAP), no change in heart rate (HR), transient reduction in TAD and no change in TBF. Rats breathing 5% CO2 (carbogen) had transiently increased MAP, decreased HR, reduced TAD and a sustained 25% TBF decrease. Animals exposed to 10% CO2 experienced a transient decrease in MAP, no HR change, reduced TAD and a 30-40% transient TBF decrease. The effects on MAP, HR, TAD and TBF were not CO2 dose-dependent, suggesting that complex physiologic mechanisms are involved. Nevertheless, when > or = 5% CO2 was breathed, there was clear vasoconstriction and TBF reduction in this model. This suggests that the effects of hypercarbic gases on TBF are site-dependent and that use of carbogen as a radiosensitizer may be counterproductive in certain situations.

Adenocarcinoma↗

Causes and effects of heterogeneous perfusion in tumors.

A characteristic of solid tumors is their heterogeneous distribution of blood flow, with significant hypoxia and acidity in low-flow regions. We review effects of heterogeneous tumor perfusion are reviewed and propose a conceptual model for its cause. Hypoxic-acidic regions are resistant to chemo- and radiotherapy and may stimulate progression to a more metastatic phenotype. In normal tissues, hypoxia and acidity induce angiogenesis, which is expected to improve perfusion. However, aggressive tumors can have high local microvessel density simultaneously with significant regions of hypoxia and acidosis. A possible explanation for this apparent contradiction is that the mechanisms regulating growth and adaptation of vascular networks are impaired. According to a recent theory for structural adaptation of vascular networks, four interrelated adaptive responses can work as a self-regulating system to produce a mature and efficient blood distribution system in normal tissues. It is proposed that heterogeneous perfusion in tumors may result from perturbation of this system. Angiogenesis may increase perfusion heterogeneity in tumors by increasing the disparity between parallel low- and high-resistance flow pathways. This conceptual model provides a basis for future rational therapies. For example, it indicates that selective destruction of tumor vasculature may increase perfusion efficiency and improve therapeutic efficacy.

Acidosis↗

Structural autoregulation of terminal vascular beds: vascular adaptation and development of hypertension.

-It is widely accepted that the early phase of primary hypertension is characterized by elevated cardiac output, whereas in later stages the increased blood pressure is due to increased peripheral resistance. To study long-term effects of increased blood flow on peripheral resistance, structural adaptation of microvascular networks in response to changes in blood flow was simulated using a previously developed theoretical model. The diameter of each vessel segment was assumed to change in response to local levels of shear stress, transmural pressure, a metabolic stimulus dependent on blood flow rate, and a conducted stimulus. Network morphologies and topologies were derived from intravital microscopy of the rat mesentery. Adaptive responses to the 4 stimuli were quantitatively balanced to yield stable and realistic distributions of vascular diameters and blood flow rates when the total flow rate was set to observed levels. To simulate effects of increased cardiac output, network flow resistance after structural adaptation was determined for a range of flow rates. Resistance increased with increasing flow, and increases in pressure were up to 3-fold greater than proportional to the increases in flow. According to the model, flow-dependent changes of network resistance result mainly from the vascular response to transmural pressure, which also causes arteriovenous asymmetry of diameters and pressure drops. Therefore, in vascular beds that exhibit arteriovenous asymmetry, increased flow may trigger increased flow resistance by a mechanism involving the tendency of vascular segments to reduce their luminal diameters in response to increased transmural pressure.

Adaptation, Physiological↗

Blood flow resistance during hemodilution: effect of plasma composition.

OBJECTIVES: To investigate the causes of wide variations in reported effects of hemodilution on flow resistance of vascular beds. METHODS: (a) In a meta-analysis of 28 prior studies, resistance values at hematocrits of zero (R0) and 0.45 (R0.45) were derived. Study design characteristics (presence of vasodilatory reserve or leukocytes, species, tissue, hemodiluent) were tested by ANOVA for their relation to the ratio R0/R0.45. (b) Experiments were performed to determine flow resistance during hemodilution in the rat mesentery with (n = 8) and without (n = 11) pretreatment with heparinase, which modifies the endothelial glycocalyx. (c) A mathematical flow simulation for mesenteric microvascular networks was used to predict resistance effects of hemodilution and of a hypothetical layer on the endothelial surface. RESULTS: (a) In prior studies using native plasma for hemodilution R0 averaged 50 +/- 8% of R0.45, while in studies using artificial solutions R0 averaged 32 +/- 12% of R0.45. The larger reduction of flow resistance upon dilution with artificial media is independent of viscosity and oncotic pressure. Other design characteristics did not show strong significant effects. (b) Present experiments showed large reductions of flow resistance with saline hemodilution which were nearly halved after heparinase pretreatment. (c) Resistance effects of hemodilution with plasma or after heparinase treatment agree with model predictions based on tube flow rheology of blood. The larger resistance effects of dilution with artificial media can be explained by the removal of an endothelial surface layer of approximately 1.5 microns thickness. CONCLUSIONS: The results imply that changes of plasma composition, due to use of artificial infusion media, influence peripheral resistance and tissue perfusion. They are consistent with the hypothesis that interactions between endothelial glycocalyx structures and plasma components lead to formation of a thick layer at the endothelial surface which increases flow resistance.

Animals↗

A model for red blood cell motion in glycocalyx-lined capillaries.

The interior surfaces of capillaries are lined with a layer (glycocalyx) of macromolecules bound or absorbed to the endothelium. Here, a theoretical model is used to analyze the effects of the glycocalyx on hematocrit and resistance to blood flow in capillaries. The glycocalyx is represented as a porous layer that resists penetration by red blood cells. Axisymmetric red blood cell shapes are assumed, and effects of cell membrane shear elasticity are included. Lubrication theory is used to compute the flow of plasma around the cell and within the glycocalyx. The effects of the glycocalyx on tube hematocrit (Fahraeus effect) and on flow resistance are predicted as functions of the width and hydraulic resistivity of the layer. A layer of width 1 micron and resistivity 10(8) dyn.s/cm4 leads to a relative apparent viscosity of approximately 10 in a 6-micron capillary at discharge hematocrit 45% and flow velocity of approximately 1 mm/s. This is consistent with experimental observations of increased flow resistance in microvessels in vivo, relative to glass tubes with the same diameters.

Capillaries↗

Structural adaptation and stability of microvascular networks: theory and simulations.

A theoretical model was developed to simulate long-term changes of vessel diameters during structural adaptation of microvascular networks in response to tissue needs. The diameter of each vascular segment was assumed to change with time in response to four local stimuli: endothelial wall shear stress (tauw), intravascular pressure (P), a flow-dependent metabolic stimulus (M), and a stimulus conducted from distal to proximal segments along vascular walls (C). Increases in tauw, M, or C or decreases in P were assumed to stimulate diameter increases. Hemodynamic quantities were estimated using a mathematical model of network flow. Simulations were continued until equilibrium states were reached in which the stimuli were in balance. Predictions were compared with data from intravital microscopy of the rat mesentery, including topological position, diameter, length, and flow velocity for each segment of complete networks. Stable equilibrium states, with realistic distributions of velocities and diameters, were achieved only when all four stimuli were included. According to the model, responses to tauw and P ensure that diameters are smaller in peripheral than in proximal segments and are larger in venules than in corresponding arterioles, whereas M prevents collapse of networks to single pathways and C suppresses generation of large proximal shunts.

Adaptation, Physiological↗

Microvascular blood flow resistance: role of endothelial surface layer.

Observations of blood flow in microvascular networks have shown that the resistance to blood flow is about twice that expected from studies using narrow glass tubes. The goal of the present study was to test the hypothesis that a macromolecular layer (glycocalyx) lining the endothelial surface contributes to blood flow resistance. Changes in flow resistance in microvascular networks of the rat mesentery were observed with microinfusion of enzymes targeted at oligosaccharide side chains in the glycocalyx. Infusion of heparinase resulted in a sustained decrease in estimated flow resistance of 14-21%, hydrodynamically equivalent to a uniform increase of vessel diameter by approximately 1 micron. Infusion of neuraminidase led to accumulation of platelets on the endothelium and doubled flow resistance. Additional experiments in untreated vascular networks in which microvascular blood flow was reduced by partial microocclusion of the feeding arteriole showed a substantial increase of flow resistance at low flow rates (average capillary flow velocities < 100 diameters/s). These observations indicate that the glycocalyx has significant hemodynamic relevance that may increase at low flow rates, possibly because of a shear-dependent variation in glycocalyx thickness.

Animals↗

Theoretical models for drug delivery to solid tumors.

The effectiveness of anti-cancer drug therapies is often limited by the difficulty of achieving drug delivery throughout solid tumors. Mathematical models permit an analysis of the factors leading to inadequate drug delivery to tumors and can suggest strategies for improving delivery. An overview is given of key factors that influence drug delivery and the extent to which they have been incorporated into existing theoretical models. These factors include spatial gradients of drug concentration and other variables within tumors and other parts of the body, and the relative magnitudes of the time scales involved in drug transport, tumor cell kinetics, and host toxicity. Models for both systemic and regional delivery methods are considered, including intravenous, intraarterial, intraperitoneal, intrathecal, and intratumoral delivery. Strategies for improving delivery are discussed, including use of two-step therapies, hyperthermia, liposome encapsulation, and magnetic targeting. Until now, modeling has mainly developed in separate subfields of tumor growth and cell kill kinetics, compartmental modeling of the body, spatially distributed models for single tissues, radiation dose calculations, tumor oxygenation, tumor blood flow, and cellular pharmacokinetics. In the future, models that integrate these subfields should be developed.

Animals↗

Resistance to blood flow in nonuniform capillaries.

OBJECTIVE: Microvessels in living tissues an not uniform cylinders, and red blood cells (RBCs) are continually deformed when traversing them. This may contribute to higher resistance to blood flow observed in microvessels compared with that in corresponding uniform glass tubes. Here, a theoretical model was used to estimate flow resistance in nonuniform capillaries and its dependence on hematocrit, flow rate, and mechanical properties of RBCs. METHODS: Single-file motion of RBCs through capillaries with sinusoidally varying cross-sections was simulated, assuming axisymmetrical geometry. Effects of cell membrane shear viscosity and elasticity were included. Lubrication theory was used to describe the plasma flow. RESULTS: Predicted resistance to blood flow in capillaries with variable cross-sections was substantially higher than in uniform vessels with the same mean diameters. Resistance depended on vessel geometry, flow rate, and hematocrit. At tube hematocrit 30%, the increase in resistance was 40%-58% when diameter varied between 4.5 and 6 microns with wavelength 20 microns and 58%-77% for variations between 4 and 5 microns with wavelength 10 microns. Larger relative increases in resistance were predicted for RBCs with increased membrane shear viscosity. CONCLUSIONS: Effects of transient RBC deformations in irregular capillaries contribute significantly to blood flow resistance in capillaries. However, this effect is not sufficient to account for the flow resistance observed in living tissues.

Animals↗

Fluctuations in red cell flux in tumor microvessels can lead to transient hypoxia and reoxygenation in tumor parenchyma.

Hypoxia occurs in two forms in tumors. Chronic or diffusion-limited hypoxia is relatively well characterized. In contrast, intermittent or perfusion-limited hypoxia is not well characterized, and it is not known how common it is in tumors. The purpose of this study was to determine whether spontaneous fluctuations in tumor microvessel flow rate can modify vessel oxygen tension (pO2) sufficiently to cause intermittent hypoxia (IH; tissue pO2 < 3 mmHg) in the tumor parenchyma supplied by such vessels. Microvessel red cell flux (RCF) and perivascular pO2 were measured simultaneously and continuously in dorsal flap window chambers of Fischer-344 rats with implanted R3230Ac tumors. In all vessels, RCF was unstable, with apex/nadir ratios ranging from 1.5 to 10. RCF and pO2 were temporally coordinated, and there were linear relationships between the two parameters. Vascular pO2 was less sensitive to changes in RCF in well-vascularized tumor regions compared with poorly vascularized regions. Simulations of oxygen transport in a well-vascularized region of a tumor demonstrated that two-fold variations in RCF can produce IH in 30% of the tissue in that region. In poorly vascularized regions, such fluctuations would lead to an even greater percentage of tissue involved in transient hypoxia. These results suggest that IH is a relatively common phenomenon. It could affect binding of hypoxic cytotoxins to tumor cells, in addition to being an important source of treatment resistance. Intermittent hypoxia also could contribute to tumor progression by providing repeated exposure of tumor cells to hypoxia-reoxygenation injury.

Adenocarcinoma↗

Analysis of red blood cell motion through cylindrical micropores: effects of cell properties.

Filtration through micropores is frequently used to assess red blood cell deformability, but the dependence of pore transit time on cell properties is not well understood. A theoretical model is used to simulate red cell motion through cylindrical micropores with diameters of 3.6, 5, and 6.3 microns, and 11-microns length, at driving pressures of 100-1000 dyn/cm2. Cells are assumed to have axial symmetry and to conserve surface area during deformation. Effects of membrane shear viscosity and elasticity are included, but bending resistance is neglected. A time-dependent lubrication equation describing the motion of the suspending fluid is solved, together with the equations for membrane equilibrium, using a finite difference method. Predicted transit times are consistent with previous experimental observations. Time taken for cells to enter pores represents more than one-half of the transit time. Predicted transit time increases with increasing membrane viscosity and with increasing cell volume. It is relatively insensitive to changes in internal viscosity and to changes in membrane elasticity except in the narrowest pores at low driving pressures. Elevating suspending medium viscosity does not increase sensitivity of transit time to membrane properties. Thus filterability of red cells is sensitively dependent on their resistance to transient deformations, which may be a key determinant of resistance to blood flow in the microcirculation.

Elasticity↗

Motion of red blood cells in capillaries with variable cross-sections.

Red blood cells undergo continual deformation when traversing microvessels in living tissues. This may contribute to higher resistance to blood flow observed in living microvessels, compared with that in corresponding uniform glass tubes. We use a theoretical model to simulate single-file motion of red cells though capillaries with variable cross-sections, assuming axisymmetric geometry. Effects of cell membrane shear viscosity and elasticity are included, but bending resistance is neglected. Lubrication theory is used to describe the flow of surrounding plasma. When a red cell encounters a region of capillary narrowing, additional energy is dissipated, due to membrane viscosity, and due to narrowing of the lubrication layer, increasing the flow resistance. Predicted resistance to cell motion in a vessel with periodic constrictions (diameter varying between 5 microns and 4 microns) is roughly twice that in a uniform vessel with diameter 4.5 microns. Effects of transient red cell deformations may contribute significantly to blood flow resistance in living microvessels.

Capillaries↗

Relationship between structural and hemodynamic heterogeneity in microvascular networks.

The relationship between structural and hemodynamic heterogeneity of microvascular networks is examined by analyzing the effects of topological and geometric irregularities on network hemodynamics. Microscopic observations of a network in the rat mesentery provided data on length, diameter, and interconnection of all 913 segments. Two idealized network structures were derived from the observed network. In one, the topological structure was made symmetric; in another a further idealization was made by assigning equal lengths and diameters to all segments with topologically equivalent positions in the network. Blood flow through these three networks was simulated with a mathematical model based on experimental information on blood rheology. Overall network conductance and pressure distribution within the network were found to depend strongly on topological heterogeneity and less on geometric heterogeneity. In contrast, mean capillary hematocrit was sensitive to geometric heterogeneity but not to topological heterogeneity. Geometric and topological heterogeneity contributed equally to the dispersion of arteriovenous transit time. Hemodynamic characteristics of heterogeneous microvascular networks can only be adequately described if both topological and geometric variability in network structure are taken into account.

Animals↗

Arteriolar oxygenation in tumour and subcutaneous arterioles: effects of inspired air oxygen content.

Carbogen is thought to be more effective than normobaric oxygen in reducing tumour hypoxia because it may reduce hyperoxic vasoconstriction. In this study, tumour and normal arteriolar diameters were measured simultaneously with perivascular pO2 during air breathing followed by either carbogen or 100% oxygen to determine whether the action of carbogen is the result of alterations in feeding vessel diameter. Fischer-344 rats bearing dorsal flap window chambers, with or without implanted R3230AC tumours, were the experimental subjects. Arteriolar diameters were measured using optical techniques and perivascular pO2 was measured using recessed-tip electrodes (3-6 microns tip diameter). Baseline arteriolar pO2 averaged 30-50% of blood gas pO2 (mean = 97 mmHg). Both hyperoxic gases increased blood gas pO2 by 4-to 5-fold, but relative improvements in arteriolar pO2 were < or = 2.5 for all arterioles studied. This means that these normobaric high O2 gases are not very efficient in increasing O2 delivery to tumours. In addition, improvements in tumour arteriolar pO2 were transient for both hyperoxic gases. Oxygen and carbogen caused no change and mild vasodilatory responses in tumour arterioles, respectively. Normal arterioles on the other hand, tended toward vasoconstriction by carbogen breathing. Peri-arteriolar pO2 in tumours increased within the first 5 min of breathing either hyperoxic gas, followed by a decline back toward values seen with air-breathing. These results suggest that temporal changes in tumour oxygenation after exposure to carbogen or O2 may not be due to changes in perfusion. Other factors, such as changes in O2 consumption rate may be involved.

Animals↗