Search PubMed⌕ Search

Biomedical subjects

T W Moore

Publications and source records attributed to T W Moore.

28 records · Page 2Linked to original sources

A compartmental model for oxygen-carbon dioxide coupled transport in the microcirculation.

We present a multicompartmental model for an oxygen-carbon dioxide transport system. The compartmental equations and their lumped parameters are derived through space averaging of the corresponding distributed model. The model can predict compartmental distributions of oxygen and carbon dioxide partial pressures, oxygen-hemoglobin saturation, and pH. Other unique features include the effects of the radial distribution of partial pressures and the difference in metabolic rates between vessel wall and tissue. A model for the cat brain, based on this formulation, is compared with results of experiments and with two types of earlier models: one without space averaging and one without carbon dioxide transport. The results suggest that space averaging the convective terms significantly affects the behavior of the model. This is consistent with conclusions from our earlier oxygen-only model. Our observations also demonstrate, however, significant differences between the results from the oxygen-carbon dioxide model and the oxygen-only model. For instance, at low blood flow rates or at low level of oxygen input, predicted oxygen partial pressures can differ by as much as 30% between the two models. Results obtained from the present model are supported by available experimental findings.

Animals↗

Incorporating vessel taper and compliance properties in Navier-Stokes based blood flow models.

A popular and useful technique used to model blood flow in cardiovascular simulations is to divide each blood vessel into a series of segments, each with its own lumped resistance, inertance, and compliance parameters. The values of these parameters are usually obtained through a simplification of the Navier-Stokes equations for fluid flow. However, the simplification often ignores the nonlinear and convective terms of the equations, resulting in errors in the parameter values, especially in the value found for resistance per unit length. We report a new method for the calculation of vessel resistance per unit length which takes into account the effects of vessel taper and wall compliance. It is shown that these effects can be addressed by the addition of two time-varying terms to the calculation of resistance per unit length. One term, due to vessel taper, is proportional to volumetric flow rate Q. The other term, due to vessel compliance, is proportional to delta p/delta t. These variables are readily available in computer simulations of blood flow in lumped parameter systems. Using data for the descending aorta, the new parameter values, when averaged over a cardiac cycle, compare favorably with results in the literature.

Animals↗

The effect of shock separation time on multiple-shock defibrillation.

Reports in the literature of studies of the efficacy of multiple, staggered shocks used for cardiac defibrillation have shown widely varying results. Twin half sinusoids, separated by an integral number of 60-Hz half-cycles, were used for transthoracic defibrillation of dogs. The separation of the pulses was varied from 0 to 13 half-cycles (0 to 108 msec). An online computer was used to determine the energy content of each shock and to obtain curves of the percentage of success vs energy, current, and voltage. The results show that 2 pulses, separated by 9 half-cycles (75 msec), require 57 percent of the peak current and 87 percent of the peak voltage required by a single pulse. The energy requirement, however, was 9.9 percent higher with the staggered shock. Other pulse separations required higher voltages and currents. Possible mechanisms for the effect are discussed.

Animals↗

Performance optimization of left ventricular assistance. A computer model study.

Performance of temporary parallel left ventricular assistance was investigated and the theoretic conditions leading to optimal behavior of the mechanical system were explored. Computer models of nonpulsatile and pulsatile left ventricular assist devices (LVADs) were incorporated into a previously reported closed-loop simulation of the canine cardiovascular system. Assuming the assisted heart was capable of recovery, LVAD performance was assessed based on both myocardial oxygen balance and cardiac output. With a synchronous LVAD, and operating in a counterpulsation mode, these variables were sensitive to the phasing of pump ejection. Maximum reduction in cardiac oxygen consumption, maximum increase in oxygen availability, and maximum increase in cardiac output with the atrio-aortic device were obtained when pump ejection immediately followed aortic valve closure. These variables were directly proportional to the magnitude of bypass volume. The pulsatile asynchronous and nonpulsatile LVAD models affected oxygen balance in a similar manner, but neither performed so well as the synchronous model when equal bypass volumes were used. Ventricular uptake of blood provided a further 27% decrease in oxygen consumption and further 78% increase in oxygen availability than atrial uptake. In summary, the model predicted that the pulsatile synchronous LVAD, filling from the ventricle during heart systole and ejecting into either the ascending or descending aorta just after ventricular systole, would be most beneficial to both myocardial oxygen balance and cardiac output.

Animals↗