Benign fibrous histiocytoma of the pterygopalatine fossa with intracranial extension.

A very rare case of fibrous histiocytoma arising in the pterygopalatine fossa with intracranial extension is described. Despite the histologic absence of nuclear pleomorphism, the tumor rapidly recurred after complete surgical resection. The patient, a 45 year old male, died shortly thereafter. The aggressive nature of our patient's tumor confirms previous observations that an aggressive radiographic appearance has prognostic value when dealing with skeletal and soft tissue tumors. The benefit of multimodal therapy has not been established in these rare head and neck lesions. In the subset of fibrous histiocytomas that invade bone, however adjunctive treatment with radiation and or chemotherapy may be appropriate.

Brain↗

Porcine small intestine submucosa as a flexor tendon graft.

An attractive strategy for tendon tissue engineering is the use of natural extracellular matrices as scaffold materials. One matrix that has been shown to promote healing and regeneration of neotissue in various applications is porcine-derived small intestinal submucosa. It was the objective of this study to investigate small intestinal submucosa for intrasynovial flexor tendon grafting in a canine model. We hypothesized that at 6 weeks small intestinal submucosa grafts would undergo host cell infiltration, neovascularization, and replacement by host neotendon. We also hypothesized that small intestinal submucosa grafts would be incorporated by the host without extensive adhesions to surrounding tissues and therefore maintain normal digit function. An intrasynovial tendon autograft was used as a gold standard. At 6 weeks the intrasynovial tendon autografts remained viable, contained normal numbers of cells along their length, and had minimal peritendinous adhesions. Four of six autografts had normal function as determined by rotation of the distal interphalangeal joint. Also at 6 weeks, the small intestinal submucosa grafts had host cell infiltration, neovascularization, and wavy, oriented tissue. However, ubiquitous adhesions together with impaired function in all cases suggest that small intestinal submucosa grafts in the configuration used are not suitable as full-length intrasynovial grafts in this tendon and animal model.

Animals↗

Simultaneous detection of Staphylococcus aureus and coagulase-negative staphylococci in positive blood cultures by real-time PCR with two fluorescence resonance energy transfer probe sets.

A real-time PCR assay that uses two fluorescence resonance energy transfer probe sets and targets the tuf gene of staphylococci is described here. One probe set detects the Staphylococcus genus, whereas the other probe set is specific for Staphylococcus aureus. One hundred thirty-eight cultured isolates, which contained 41 isolates of staphylococci representing at least nine species, and 100 positive blood cultures that contained gram-positive cocci in clusters were tested. This assay was 100% sensitive and 100% specific for the detection of the Staphylococcus genus and of S. aureus.

Blood↗

Bone graft incorporation in radiographically successful human intervertebral body fusion cages.

STUDY DESIGN: Biopsies were obtained from within radiographically successful human intervertebral body fusion cages to document the histology of remodeling bone graft. OBJECTIVES: The purpose of this study is to describe the tissue within successful human interbody cages with special reference to the viability of bone and the presence or absence of debris particles. SUMMARY OF BACKGROUND DATA: The use of interbody fusion cages is gaining rapid acceptance, but there is little histologic documentation of the nature of tissue within successful human interbody fusion cages. METHODS: Needle biopsies were obtained of tissue within radiographically successful intervertebral body fusion cages at the time of pedicle screw removal for back pain or fusion of adjacent spinal level in nine spinal levels of eight patients. Preoperative diagnoses of these eight adult patients included disease conditions in the sagittal plane: spondylosis (5), degenerative disc disease (6), failed laminectomy and discectomy (2), radiculopathy (1), and spondylolisthesis (1). In all cases the cages had been packed with autograft (iliac crest 7, local 1) at the time of insertion. Cage implantation was performed with anterior (anterior lumbar interbody fusion 4, corpectomy and plate fixation 1), and posterior (posterior lumbar interbody fusion 4), segmental instrumentation (plate 1, or pedicle screws 8). All cases except one cervical case had posterolateral fusion or bilateral facet fusion. The cages were composed of carbon fiber-reinforced polymer (Brantigan cage; DePuy AcroMed, Raynham, MA, n = 5) or titanium mesh (Harms Cage; DePuy AcroMed, Raynham, MA, n = 4). Cages had been in situ from 8 to 72 months (mean 28 months). All nine biopsies from eight patients were obtained from within the center of the cages. Specimens were decalcified, routinely embedded in paraffin, stained with hematoxylin and eosin, and viewed qualitatively with transmitted and polarized light. RESULTS: All needle biopsies were obtained from within the center of the cages, and no patient developed spinal instability after the biopsy. All nine biopsies showed small fragments of necrotic bone associated with viable bone and restoration of hematopoietic bone marrow. Numerous cement lines demarcated the edges of previous cycles of remodeling. The ratio of necrotic to viable bone varied greatly among cases. Small particles of debris were associated with four of the five carbon-fiber cages and one of the four specimens from titanium cages, but there was no visible bone resorption or inflammation. CONCLUSIONS: Autogenous bone graft was incorporated in these radiographically successful human intervertebral body fusion cages. A few debris particles were observed, but there was no histologic evidence of particle-induced bone resorption or inflammation.

Adult↗

Preliminary report of photodynamic therapy for intraperitoneal sarcomatosis.

INTRODUCTION: Sarcomatosis is the disseminated intraperitoneal spread of sarcoma. It is a condition for which there is no effective treatment. Photodynamic therapy (PDT) is a cancer treatment modality that uses a photosensitizing agent and laser light to kill cells. We report our preliminary Phase II clinical trial experience using PDT for the treatment of intraperitoneal sarcomatosis. METHODS: From May 1997 to December 1998 eleven patients received twelve PDT treatments for intraperitoneal sarcomatosis. Photofrin (PF) 2.5 mg/kg was administered intravenously 48 hours before surgical debulking to a maximum residual tumor size of less than 5 mm. Light therapy was administered at a fluence of 2.5 J/cm2 of 532 nm green light to the mesentery and serosa of the small bowel and colon; 5 J/cm2 of 630 nm red light to the stomach and duodenum; 7.5 J/cm2 of red light to the surface of the liver, spleen, and diaphragms; and 10 J/cm2 of red light to the retroperitoneal gutters and pelvis. Light fluence was measured with an on-line light dosimetry system. Response to treatment was evaluated by abdominal CT scan at 3 and 6 months, diagnostic laparoscopy at 3 to 6 months, and clinical examination every 3 months. RESULTS: Adequate tumor debulking required an omentectomy in eight patients (73%), small bowel resection in seven patients (64%), colon resection in four patients (36%), splenectomy in one patient (9%), and a left spermatic cord resection in one patient. Five patients (45%) have no evidence of disease at follow-up (range, 1.7-17.3 months), including patients at 13.8 and 17.3 months examined by CT. Two patients (18%) died from disease progression. Four patients (36%) are alive with disease progression. Toxicities related to PDT included substantial postoperative fluid shifts with volume overload, transient thrombocytopenia, and elevated liver function tests. One patient suffered a postoperative pulmonary embolism complicated by adult respiratory distress syndrome (ARDS). CONCLUSIONS: Debulking surgery with intraperitoneal PDT for sarcomatosis is feasible. Preliminary response data suggest prolonged relapse-free survival in some patients. Additional follow-up with more patients will be necessary for full evaluation of the added benefit of PDT and aggressive surgical debulking in these patients.

Adult↗

Paratibial cyst associated with wear debris after total knee arthroplasty.

We present a case in which a synovial cyst arose from the proximal tibia and expanded in the calf of a patient after total knee arthroplasty. A cystogram showed a direct communication between the joint cavity and the cyst, apparently associated with a screw that penetrated the tibial cortex. Histologic examination of the cyst showed an inflammatory reaction, including macrophages, foreign body giant cells, and metal and polyethylene particles. To our knowledge, this is the first case report illustrating a paraosseous cyst that developed after total knee arthroplasty. Wear debris from the total knee prosthesis may have been responsible for this unusual cyst.

Arthroplasty, Replacement, Knee↗

Debris from failed ceramic-on-ceramic and ceramic-on-polyethylene hip prostheses.

To compare the properties of wear debris between ceramic-on-ceramic and ceramic-on-polyethylene total hip prostheses, particles were isolated and characterized from tissue biopsies obtained at revision arthroplasty or autopsy from two similar uncemented modular hip systems. Group A hips (11 patients; mean, 31 months in vivo) had titanium shells with alumina inserts, alumina femoral heads, and titanium alloy stems. Group B hips (seven patients; mean, 42 months) were the same as Group A but with polyethylene acetabular inserts. Particles were characterized using an electrical resistance particle analyzer, scanning electron microscope, and energy dispersive xray spectroscope. Most of the particles in Group A were ceramic, whereas most of the particles in Group B were polyethylene. Metal particles from the femoral stem and the acetabular shell also were present. If one Group A hip with impingement is excluded, the rate of particle production is significantly lower in the ceramic-on-ceramic group than in the ceramic-on-polyethylene group. With the number of samples available, no significant difference in average size could be detected among the different types of particles or among the groups.

Ceramics↗

Influence of stability and mechanical properties of a spinal fixation device on production of wear debris particles in vivo.

A prospective and quantitative animal study was performed to evaluate the production of wear particles from a spinal fixation device, and to test the hypothesis that the concentration of wear debris particles adjacent to spinal fixation hardware is correlated with the stiffness of the spinal fusion construct and local bone formation at the fusion site. An established canine segmental spinal fusion model with three interfacet fusions was used in this study. Several bone substitute materials were grafted to the area of the interfacet fusion. Internal fixation was performed on both sides of the spinous processes at each site using a stainless steel plate system in 19 dogs. After 12 weeks, spinal segments were excised, then 3-dimensional computerized tomography was used to measure bone volume and bone area of the individual fusion sites. The stiffness of each segment was tested using a servohydraulic materials testing machine. Biopsies were obtained from the soft tissues immediately around the plate system, and wear particles were collected and characterized using an electrical resistance particle analyzer, light and scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDX). Biopsies from para-spinal tissue from adjacent, unoperated spinal levels served as negative controls. Histologically, 24 of 57 specimens (42.1%) showed only fibrous tissue with no recognizable macrophages, inflammation, or debris. Fourteen of 57 specimens (24.6%), however, contained many particles that were composed of Fe, Cr, and Ni, corresponding to elements found in the fixation hardware. Another 19 specimens showed only occasional particles. The mean concentration of particles from the tissue around the plate system was 2.8 x 10(9) per gram dry tissue weight, compared to 0.5 x 10(9) particles per gram for controls (p < 0.05). Statistical analyses showed significant inverse correlation between the log particle number and stiffness (r = -0.41, p < 0.01), bone volume (r = -0.28, p < 0.05), and bone area (r = -0.34, p < 0. 05) of the corresponding segments. The concentration of particles in the tissue showed a significant inverse correlation with stiffness, bone volume, and bone area of the fusion constructs.

Animals↗

The spatial location of impingement in total hip arthroplasty.

Impingement between acetabular and femoral components produces wear debris and results in abnormal loads on the edge of the implant. To characterize further the spatial location of impingement and the design and alignment factors associated with impingement, we reviewed 111 retrieved acetabular components from a single manufacturer. The location of impingement in the pelvis was determined by combining the location of impingement in the retrieved implants and the spatial orientation of the acetabular components measured from available radiographs. Evidence of impingement was identified in 39% of the retrieved implants and involved the posterior portion of the acetabulum in all cases. Posterior impingement was probably the result of femoral extension and external rotation, a motion that occurs during the toe-off phase of the gait cycle. Cups with impingement were more anteverted than those without impingement (P = .016). There was a significant inverse association between impingement and the size of the femoral head, and the mean head-to-neck diameter ratio for implants with impingement was smaller than that for implants without impingement (P < .0001). Factors that appear to be associated with impingement include i) excessive cup anteversion combined with posterior positioning of the extended rim and ii) femoral components with relatively small head-to-neck diameter ratio.

Adult↗

Wear debris from two different alumina-on-alumina total hip arthroplasties.

We compared wear particles from two different designs of total hip arthroplasty with polycrystalline alumina-ceramic bearings of different production periods (group 1, before ISO 6474: group 2, according to ISO 6474). The neocapsules and interfacial connective tissue membranes were retrieved after mean implantation times of 131 months and 38 months, respectively. Specimen blocks were freed from embedding media, either methylmethacrylate or paraffin and digested in concentrated nitric acid. Particles were then counted and their sizes and composition determined by SEM and energy-dispersive x-ray analysis (EDXA). The mean numbers and sizes of most alumina wear particles did not differ for both production periods, but the larger sizes of particle in group 1 point to more severe surface destruction. The increased metal wear in group 2 was apparently due to alumina-induced abrasion of the stems. In this study the concentrations of particles in the periprosthetic tissues were 2 to 22 times lower than those observed previously with polyethylene and alumina/polyethylene wear couples.

Adult↗

Bone graft materials. An overview of the basic science.

Autograft, allograft, and synthetic bone graft substitute materials play an important role in reconstructive orthopaedic surgery, and understanding the biologic effects of these materials is necessary for optimum use. Although vascularized and cancellous autograft show optimum skeletal incorporation, host morbidity limits autograft availability. Experimental studies have confirmed an immune response to allograft bone, but the clinical significance of this response in humans still is unclear. Small amounts of cancellous allograft in humans usually are remodeled completely; large allografts become incorporated by limited, surface intramembranous bone formation suggesting that these graft are primarily osteoconductive. Several synthetic skeletal substitute materials also are osteoconductive, and may show remodeling characteristics similar to allograft. Demineralized bone matrix and some isolated or synthetic proteins can induce endochondral bone formation, and therefore are osteoinductive. The extent and distribution of remodeling of bone graft materials are influenced by many factors, including the quality of the host site and the local mechanical environment (strain). Graft materials are likely to become more specialized for use in specific clinical applications, and composite preparations may soon provide bone graft materials with efficacy that equals or exceeds that of autogenous grafts.

Animals↗

Polyethylene wear vector in vivo: a three-dimensional analysis using retrieved acetabular components and radiographs.

Polyethylene wear of the acetabular component can be described as one or more vectors. To help clarify the mechanisms of wear advancement in vivo, we used a combination of retrieved implants and radiographs to describe the three-dimensional wear vectors in total hip arthroplasty. The wear vectors in 41 retrieved implants from a single manufacturer were measured with use of the shadowgraph technique, and the spatial orientation of each implant was calculated from serial anteroposterior pelvic radiographs. On the basis of the combination of the wear vector in the implant and implant orientation in the pelvis, the wear vectors in vivo were determined. The mean wear vector was directed 8.1 degree lateral in the coronal plane and 4.1 degree posterior in the sagittal plane. The wear vectors in vivo showed a relatively wide range of directions, not necessarily coinciding with the commonly presumed resultant force in the hip. The wear vectors were not associated with the spatial orientation of the acetabular components, but cups with impingement demonstrated more anterior wear than did those without impingement. Our results suggest that the process of polyethylene wear is not as simple as previously described and that several factors influence advancement of wear in vivo.

Acetabulum↗

The pathology of total joint arthroplasty. I. Mechanisms of implant fixation.

The clinical results of total joint arthroplasty are usually excellent, but surgeons, radiologists, and pathologists are often called upon to evaluate, in one way or another, the stability of the implants. These evaluations are aided by an understanding of the basic pathophysiology of total joint arthroplasty. The first part of this two-part review, will summarize the mechanisms whereby total joint implants achieve fixation. The second part will describe and illustrate the most important mechanisms of implant loosening. The "gold standard" for hip and knee arthroplasty is to use polymethylmethacrylate bone cement to anchor the implant to bone, but the optimal surface texture of cemented implants is controversial. Some surgeons advocate a rough implant texture to facilitate bonding between implant and cement; other surgeons prefer a smooth, polished implant to minimize abrasion of cement. Implant loosening can be initiated by particles of cement generated at either the implant/cement, or cement/bone interface. Uncemented implants with porous metal surfaces achieve a variable amount of bone ingrowth, but some designs have excellent clinical results. Maximal bone ingrowth usually occurs along surfaces that are relatively close to cortical bone. Implants with bioactive coatings, such as hydroxyapatite achieve rapid bone apposition. The amount of bone that persists on uncemented implants long-term is determined by many variables, inlcuding the quality of the coating, the overall implant design, and factors that influence local bone remodeling.

Animals↗

The pathology of total joint arthroplasty.II. Mechanisms of implant failure.

Although the clinical results of total joint arthroplasty are usually excellent, some implants develop loosening and require revision. Implants usually fail by a combination of mechanisms, but different basic designs tend to show different dominant mechanisms of failure. Infection causes failure of about 1-5% of cases of primary arthroplasty. Clues to the presence of infection include clinical signs, a periosteal reaction, a positive culture of aspirated joint fluid, and acute inflammation identified in tissue around the implant. There are several different mechanisms and modes of implant wear, and perhaps the most important cause of aseptic loosening is an inflammatory reaction to particles of wear debris. Abrasive, adhesive, and fatigue wear of polyethylene, metal and bone cement produces debris particles that induce bone resorption and implant loosening. Particles can cause linear, geographic, or erosive patterns of bone resorption (osteolysis), the distributions of which are influenced by the implant design. Micromotion of implants that did not achieve adequate initial fixation is another important mechanism of loosening. Fatigue failure at the bone/cement and bone/implant interface may cause aseptic loosening, and may be especially important for implants with relatively smooth surfaces. Stress shielding can influence local bone density, but is rarely an isolated cause of implant loosening. Elevated hydrodynamic pressure has been associated with bone resorption in the absence of implants, and may also play a role in implant loosening.

Arthroplasty, Replacement↗

Multidirectional deformation in fully congruent acetabular components.

Most clinical studies have used femoral head migration as an index of acetabular wear, but a previous study showed multiple wear vectors in 30% of retrieved acetabular components with noncongruent liners. The origin of multiple wear vectors is unclear, and it has been suggested that polyethylene creep in a noncongruent shell might influence deformation on the articular surface. We used shadowgraph and volumetric methods to evaluate the extent and direction of surface deformation of 37 retrieved polyethylene liners that were fully congruent to a single design of metal backing. The results show that multiple deformation vectors are relatively common in retrieved acetabular cups (27% in this study) and are independent of congruency between liner and metal backing, rim impingement, and backside creep. Polyethylene liners with multiple wear vectors were significantly thinner than those of cups with a single vector. The origin of multiple vectors is still unclear, but clinical and laboratory studies measuring linear wear alone without recognizing multiple vectors underestimate total in vivo volumetric wear.

Acetabulum↗