Characterization of unfractionated heparin: comparison of materials from the last 50 years.

Physicochemical and anticoagulant characteristics of 27 samples from recent batches of commercially produced unfractionated heparin have been determined as part of the process of establishment of the 5th International Standard Unfractionated Heparin. They have been compared with current heparin standards (European Pharmacopoeia, United States Pharmacopoeia, Chinese), with the 4th International Standard Unfractionated Heparin. and with the three predecessor International Standards. The results indicate that the 4th International Standard Unfractionated Heparin, established in 1982, has significantly lower molecular weight and specific activity than recently produced heparin; this is also true of all preceding International Standard Heparins and of the United States Pharmacopoeial standard. The composition of commercial unfractionated heparin may therefore have changed over time; reasons for this are discussed.

Blood Coagulation Tests↗

An international collaborative study on the INR calibration of freeze-dried reference plasmas.

A study was carried out to calibrate potential European Reference Plasmas for prothrombin time (PT) standardization. The International Normalized Ratio (INR) values of three freeze-dried candidate plasmas (one pooled normal and two pools from anticoagulated patients) were determined in 20 laboratories using six thromboplastin reagents comprising three International Reference Thromboplastins (human, rabbit and bovine), two recombinant human reagents and one placental human reagent. Interlaboratory variability of INR estimation was low with geometric coefficients of variation (gcv) <10% except in one case. Significant differences in mean INR were found between the different thromboplastins with lowest INR values found with the bovine reagent. INR values from the International rabbit and human reagents differed by <6% and were combined to give proposed assigned INR values. Significant differences in INR estimates from four thromboplastins of human origin may indicate that single assigned INR values are not applicable for use with all thromboplastin reagents. Field trials to assess the validity of single assigned INR values in clinical practice are required.

Animals↗

Phospholipid binding of factor VIII in different therapeutic concentrates.

Binding to anionic phospholipid (PL) is essential for the biological function of factor VIII (FVIII). We have developed a method to study the level of PL binding of FVIII in a variety of therapeutic concentrates, using the BIACORETM system which utilizes the Surface Plasmon Resonance (SPR) phenomenon. A HPA sensor chip was employed on to which synthetic phospholipid unilamellar vesicles were adsorbed to form a 3:1 phosphatidylcholine: phosphatidylserine lipid monolayer. Using this surface the interaction of unlabelled FVIII in concentrates was observed from which direct kinetic data (kon, koff and KD values) were obtained in real-time. Marked differences in the binding to PL, as measured by KD values, between different products were observed. These fell into three categories: two recombinant FVIII products showed high affinities for PL with KD values around 0. 05-0.14 nM; four high-purity plasma derived products, two prepared by monoclonal antibody and two prepared by ion-exchange chromatography, had 6-8-fold lower affinities, and two intermediate-purity products had 34-60-fold lower affinities with KD values in the nM region. Measurements of kon and koff values for each product showed that the differences in the KD values expressed were primarily due to the differences in their respective kon values, although the recombinant products showed changes in the koff values. The study showed that the assessment of binding to PL by FVIII in concentrates was possible without prior purification and gave KD values in the range reported previously for other methods. The difference between the products requires further investigation but may be partly due to other proteins present, in particular the content and quality of von Willebrand factor which is known to affect PL binding of FVIII.

Dose-Response Relationship, Drug↗

Structural determination of lipid-bound human blood coagulation factor IX.

Human coagulation factor IX (FIX) is a serine protease which binds to a negatively charged phospholipid surface in the presence of Ca ions (Ca2+). FIX two-dimensional (2-D) crystals were obtained by the lipid layer crystallisation technique under near physiological conditions. The 2-D projection map of the protein was calculated to a resolution of 3 nm using electron crystallographic analysis. The structural organisation of membrane-bound FIX is discussed and compared with the known X-ray crystallographic data.

Binding Sites↗

Discrepancies in potency assessment of recombinant FVIII concentrates.

Results of assays of recombinant FVIII concentrates have been reviewed over a 10-year period. Initially there was wide variability between laboratories but this was minimised by the development of standardised assay methodology, in particular the use of haemophilic plasma for pre-dilution and 1% albumin in assay buffers. Using this standardised methodology and concentrate standards, there were no major differences in potency between one-stage, two-stage and chromogenic assays on the two full-length recombinant FVIII concentrates. However, using a plasma standard, the chromogenic method gave much higher potencies than the one-stage method on the same concentrates, and this explains a similar discrepancy found in patients' post-infusion samples after injection of recombinant concentrates. It is suggested that concentrate standards be used for such post-infusion samples in order to minimise this discrepancy.

Biological Assay↗

Minimum lyophilized plasma requirement for ISI calibration. European Concerted Action on Anticoagulation.

The minimum requirement of lyophilized plasma samples for a reliable International Sensitivity Index (ISI) was assessed by calibrations based on reducing numbers from a maximum of 60 depleted and 20 plasma samples from patients receiving coumarin using a manual technique and low ISI thromboplastin. The probability of achieving an international normalized ratio (INR) result within a clinically important range of 20% deviation has been assessed at European Concerted Action on Anticoagulation (ECAA) national laboratories in calibrations of ECAA reference thromboplastin against the certified prothrombin time (PT) with a reference thromboplastin. With conventional orthogonal regression using a certified PT and linear regression using certified INR, deviations and the coefficient of variation of the calibration slope increased with reduced numbers. The INR deviations became marked when the number of abnormal plasma samples was reduced to fewer than 20. Calibrations of 3 abnormal plasma samples and 1 lyophilized normal plasma sample gave a high incidence of deviations greater than 10% with an INR of 3.0. The study demonstrates that with both methods of analysis, an optimum minimum number of lyophilized plasma samples is needed for a reliable local ISI.

Calibration↗

The European Concerted Action on Anticoagulation (ECAA) evaluation of a set of lyophilized normal plasmas to establish the normal prothrombin time for coagulometer systems.

Establishing the mean normal prothrombin time (MNPT) from fresh samples for prothrombin ratios and INR often presents difficulty in selection and collection of donors. A set of seven lyophilized normal plasmas has therefore been prepared at the ECAA Central Facility and studied at 143 laboratories in sixteen European states using coagulometers in serial field exercises. All centres tested either the high ISI ECAA rabbit or low ISI ECAA human reference thromboplastin. The MNPT of fresh plasmas and means of the lyophilized samples were closely comparable with most routine rabbit thromboplastins. Using human thromboplastins means with the lyophilized normals were marginally but significantly longer and with the bovine Thrombotest significantly shorter than the MNPT of fresh plasmas causing alterations in INR. There was no appreciable effect on INR of 2.5 and 3.5 when lyophilized normals were substituted for fresh normals with the rabbit reagents.

Animals↗

College of American Pathologists Conference XXXI on laboratory monitoring of anticoagulant therapy: the clinical use and laboratory monitoring of low-molecular-weight heparin, danaparoid, hirudin and related compounds, and argatroban.

OBJECTIVE: To review the role of the laboratory in monitoring therapy with low-molecular-weight heparin, danaparoid, hirudin, and argatroban, as reflected in the medical literature and the consensus opinion of recognized experts in the field. DATA SOURCES: Review of the medical literature and current clinical practice by a panel of 6 international experts in the field of anticoagulant therapy. DATA EXTRACTION AND SYNTHESIS: The experts made an extensive review of the published literature and prepared a draft manuscript, which included preliminary recommendations. The draft manuscript was circulated to participants in the College of American Pathologists Conference XXXI on Laboratory Monitoring of Anticoagulant Therapy prior to the conference. The manuscript and recommendations were then presented at the Conference for discussion. Recommendations were accepted if a consensus of the 26 experts attending the Conference was reached. The results of the discussion were used to revise the manuscript into its final form. CONCLUSIONS: This report reviews the mechanism of action and potential uses of these newer anticoagulant agents. General guidelines for monitoring these agents and 9 specific recommendations for laboratory monitoring of low-molecular-weight heparin and danaparoid are provided, along with citation of the appropriate supporting literature. Issues for which a consensus was not reached at the Conference are also discussed.

Anticoagulants↗

Modification of factor VIII in therapeutic concentrates after virus inactivation by solvent-detergent and pasteurisation.

The addition of a pasteurisation step to a solvent/detergent (SD) treated FVIII concentrate has recently resulted in enhanced inhibitor incidence in patients in Germany and Belgium. We have investigated the effect of virus inactivation procedures on FVIII function by preparing experimental concentrates from the same starting cryoprecipitate with the following procedures: none (N); dry heat (DH); pasteurisation (P); solvent/detergent (SD); solvent detergent + dry heat (SDDH); solvent detergent + pasteurisation (SDP). In addition, several clinical SD concentrates with and without pasteurisation were studied. There were no significant differences in fibrinogen and vWF content and in the ratio of one-stage/chromogenic FVIII activity among any of the samples studied. In thrombin proteolysis and FXa generation experiments, there were no differences in results on samples N, DH, P, and SDDH from those on sample SD. However sample SDP gave markedly different results from sample SD in the following respects: slower thrombin proteolysis (t(1/2) = 12.0 min vs 1.9 min); more rapid FXa generation (rate 2.5 times that of SD); enhanced phospholipid binding (K(D) = 3.89 x 10(-11) M vs 5.53 x 10(-10) M). Similar differences between SDP and SD were seen in the clinical samples. The observed changes in the FVIII activity occurred in combination with SD and pasteurisation, but not with either treatment alone. These results suggest that SDP treatment may enhance exposure of the phospholipid binding site in the C2 domain of FVIII, and since inhibitors to the SDP product are predominantly against C2, these findings could be relevant to the enhanced immunogenicity of the SDP product.

Detergents↗

International Normalized Ratio determination using calibrated reference plasmas.

We have compared the conventional method of International Normalized Ratio (INR) determination with an alternative method involving extrapolation from a calibration curve using freeze-dried 'reference' plasmas. The latter approach does not require the determination of a mean normal prothrombin time (MNPT) or local system International Sensitivity Index (ISI). Calibration curves were constructed by plotting local prothrombin time (PT) against assigned INR values for a normal plasma and either two plasma pools from patients on oral anticoagulants or two artificially depleted plasmas. Six laboratories determined the INR of a freeze-dried test plasma and frozen patient plasma samples using the conventional method and by extrapolation. Similarities in the results with the freeze-dried test plasma and the frozen plasmas were encouraging for the projected use with fresh plasma samples. INR values by the conventional method for the test plasma gave an overall mean of 2.73 and inter-laboratory variability (gcv%) of 8.92%, whereas estimates by extrapolation against the normal and patient plasmas or the normal and artificially depleted plasmas gave identical overall mean INR values of 2.70 with inter-laboratory variability (gcv%) of 3.44% and 4.92% respectively. The results indicate that INR determination by extrapolation is associated with reduced interlaboratory variability.

Blood Coagulation Tests↗

A simplified statistical method for local INR using linear regression. European Concerted Action on Anticoagulation.

A simplified method of International Normalized Ratio (INR) derivation using linear regression of certified INR plotted against local prothrombin time (PT) results has been compared with INR from conventional orthogonal regression. Linear regression assumes error only with the local PT results whereas orthogonal regression assumes error with both reference and local results. The reliability of local INR derivation using lyophilized plasmas has been assessed in a collaborative study. INR from conventional fresh plasma International Sensitivity Index (ISI) calibrations have been compared with INR from calibrations with two types of lyophilized plasma, artificially depleted and coumarin. Although calibration slopes differed with the two types of analysis and the different lyophilized plasmas, both gave reasonable approximations to fresh plasma ISI calibrations. With orthogonal regression the overall percentage INR deviation was 5.25% with the artificially depleted plasmas and 6.85% for the results with lyophilized coumarins. With the linear regression, deviation was 8.40% for the artificially depleted plasmas and 5.05% for coumarin-treated patients' lyophilised-plasma. The simpler regression method appears to be worthy of further study as the present report has demonstrated that if the calibrant plasmas are accurately certified with the thromboplastin International Reference Plasma (IRP) results approximate to the conventionally determined INR using the manual PT technique. Coagulometers require further assessment.

Blood Coagulation Tests↗

Molecular weight measurements of low molecular weight heparins by gel permeation chromatography.

The molecular weight profiles of low molecular weight heparin samples have been measured by high-performance gel permeation chromatography using as calibrant the heparinase-degraded material (90/686) now established as the 1st International Reference Preparation (IRP) Low Molecular Weight Heparin for Molecular Weight Calibration Use of the calibrant as a broad molecular weight standard is described and a calibration table provided based on data collected over several years in one laboratory. In order to confirm the assignment of degree of polymerisation to resolved oligosaccharide peaks in the calibrant, molecular weights of oligosaccharides fractionated from the 1st IRP were independently determined by fast atom bombardment mass spectrometry (FAB MS). The molecular weight distributions of commercial low molecular weight heparins have been characterized. Measurements of molecular weight parameters of heparin molecular weight standards from several sources provide comparisons between the molecular weight scales of this and other studies.

Calibration↗

Inhibition of thrombin generation by heparin and LMW heparins: a comparison of chromogenic and clotting methods.

Inhibition of thrombin generation by heparin and low-molecular-weight (LMW) heparins is an important parameter which relates to their anticoagulant actions in vivo. Previous studies in our laboratory used a clotting assay for assessment of thrombin generation but other published studies have used a chromogenic method. We have therefore measured the inhibition of thrombin generation by unfractionated heparin (UFH) and LMW heparins by a modified chromogenic method using microtitre plates and compared the results with the clotting method. The degree of inhibition of thrombin generation when calculated from both peak thrombin concentrations and areas under the curve in the chromogenic assay was the same. When the activities of each heparin were expressed as EC80, i.e. concentrations required for 80% inhibition of thrombin generation, the EC80 were higher in the chromogenic assay than in the clotting system. However when the potencies of the LMW heparins were expressed as percentages of that of the UFH standard by parallel line analysis, the differences between clotting and chromogenic assay results were small and not statistically significant (P > 0.05). This study demonstrates the feasibility of measuring inhibition of thrombin generation by a modified chromogenic method using microtitre plates, and shows that the results with this method are similar to those obtained with the clotting method.

Anticoagulants↗

In vivo studies of activated porcine factor VIII.

The haemostatic effectiveness of activated FVIII was compared to that of non-activated FVIII in a cross-over study in a canine model of haemophilia. Activation of FVIII in porcine concentrate was achieved by the addition of 3 x 10(-5) IU thrombin per ml of concentrate, which gave consistent increases in 1-stage FVIII activity of 13- to 14-fold and slow decay. The haemostatic effect was monitored by measurements of the cuticle bleeding time 10 and 45 min after infusion and there were no consistent differences between the activated and non-activated concentrates. One-stage factor VIII assays on plasmas 5 min after infusion showed identical mean values for activated and non-activated concentrates, indicating that most of the higher activity observed in vitro had disappeared rapidly from the circulation. These results suggest that controlled activation of FVIII by thrombin, which increases its activity in 1-stage assays, is unlikely to be of therapeutic benefit. For therapeutic concentrates which may contain small amounts of activated FVIII, the 1-stage assay may be an unreliable guide to their therapeutic effect.

Animals↗

European Concerted Action on Anticoagulation (ECAA)-the multicentre calibration of rabbit and human ECAA reference thromboplastins. Steering Committee.

Two candidate ECAA reference preparations have been calibrated in a multicentre exercise at 14 representative national laboratories to provide reference thromboplastin for a large field study in 16 European countries. Two preparations were required because of the established differences in ISI arising from the two main routes of calibration via rabbit and human IRP. To be comparable with working reagents in everyday use a human plain recombinant reagent of low ISI and a rabbit plain preparation of moderately high ISI were selected. A precise calibration of the two candidate preparations has been achieved with the manual PT technique and an ISI of 0.95 (SE 0.0078) for the human reagent and 1.67 (SE 0.0322) for the rabbit reagent.

Animals↗

Collaborative study on assays of activated FIX (FIXa). On behalf of the factor VIII and factor IX subcommittee of the ISTH. International Society on Thrombosis and Haemostasis.

A collaborative study has been organised by NIBSC to examine the performance of FIXa assays between laboratories, and to investigate the need for a standard. Ampoules of 3 materials, one monocomponent concentrate (coded C) and 2 different preparations of purified human FIXa (one proposed reference preparation, coded A and a test material coded B), have been assayed in 11 laboratories for FIXa using either the NIBSC method or a local method, with local standards (if available, coded D) to determine their potencies. The data showed high between assay variability; with the exception of one laboratory, most of the between assay variation expressed as %geometric coefficients of variation (gcv) were over 15%. The interlaboratory gcv when preparation B was assayed against the local standard was over 1700%, suggesting that most of the local standards are poorly calibrated. The %gcv was improved to 80% when reference A was used as the standard. These data clearly show that an international reference standard for FIXa would help to standardise FIXa preparations and would also improve in house assays for FIXa. However, an accelerated degradation study has shown that reference A is not suitable as a long term standard and another material with suitable stabilizers has to be established as an international standard for FIXa.

Factor IX↗

Low anticoagulant heparin retains anti-HIV type 1 activity in vitro.

Heparin is a potent inhibitor of HIV-1 replication, in addition to being a well-established inhibitor of blood coagulation. The major anticoagulant activity of heparin results from binding to the plasma protein antithrombin (AT). The high-affinity binding site for AT is a specific pentasaccharide sequence that is of low abundance and completely absent from the majority of heparin chains. We have examined the anti-HIV-1 activity of both conventional and low molecular weight heparins fractionated according to affinity for AT. The high- and low-affinity fractions, despite differing markedly in anticoagulant activity, are identical in their ability to bind to the envelope glycoprotein of HIV-1, and in their inhibitory effect on HIV-1 replication in vitro (EC50 1 and 8 micrograms/ml for conventional and low molecular weight fractions, respectively). Our study shows that the anti-HIV activity of heparin is independent of its antithrombin-mediated inhibition of coagulation proteases. Therefore, heparin preparations retaining full anti-HIV-1 activity in vitro but with greatly reduced anticoagulant activity may be readily produced for further clinical investigation in the prophylaxis and therapy of HIV infection.