Search PubMed⌕ Search

Biomedical subjects

T Thundat

Publications and source records attributed to T Thundat.

At least 37 records · Page 2Linked to original sources

Measuring magnetic susceptibilities of nanogram quantities of materials using microcantilevers.

We describe a novel technique for measuring magnetic susceptibilities of nanogram quantities of magnetic materials that utilizes the extreme force sensitivity of microcantilevers. The magnetic force acting on samples attached to the free end of a cantilever can be measured as changes in the resonance response of the cantilever. The shift in resonance frequency of the cantilever is proportional to the field gradient, whereas the deflection of a cantilever is proportional to the magnetic force. The magnetic susceptibility measurement is based on comparison of the forces acting on the sample and a reference material in the same magnetic field and field gradient. We have determined the magnetic susceptibilities of nanogram quantities of many paramagnetic materials. The measured magnetic susceptibilities show excellent agreement with values found in the literature.

Journal Article↗

Bioassay of prostate-specific antigen (PSA) using microcantilevers.

Diagnosis and monitoring of complex diseases such as cancer require quantitative detection of multiple proteins. Recent work has shown that when specific biomolecular binding occurs on one surface of a microcantilever beam, intermolecular nanomechanics bend the cantilever, which can be optically detected. Although this label-free technique readily lends itself to formation of microcantilever arrays, what has remained unclear is the technologically critical issue of whether it is sufficiently specific and sensitive to detect disease-related proteins at clinically relevant conditions and concentrations. As an example, we report here that microcantilevers of different geometries have been used to detect two forms of prostate-specific antigen (PSA) over a wide range of concentrations from 0.2 ng/ml to 60 microg/ml in a background of human serum albumin (HSA) and human plasminogen (HP) at 1 mg/ml, making this a clinically relevant diagnostic technique for prostate cancer. Because cantilever motion originates from the free-energy change induced by specific biomolecular binding, this technique may offer a common platform for high-throughput label-free analysis of protein-protein binding, DNA hybridization, and DNA-protein interactions, as well as drug discovery.

Biosensing Techniques↗

Mapping individual cosmid DNAs by direct AFM imaging.

Individual cosmid clones have been restriction mapped by directly imaging, with the atomic force microscope (AFM), a mutant EcoRI endonuclease site-specifically bound to DNA. Images and data are presented that locate six restriction sites, predicted from gel electrophoresis, on a 35-kb cosmid isolated from mouse chromosome 7. Measured distances between endonuclease molecules bound to lambda DNA, when compared to known values, demonstrate the accuracy of AFM mapping to better than 1%. These results may be extended to identify other important site-specific protein-DNA interactions, such as transcription factor and mismatch repair enzyme binding, difficult to resolve by current techniques.

Animals↗

Direct atomic force microscope imaging of EcoRI endonuclease site specifically bound to plasmid DNA molecules.

Direct imaging with the atomic force microscope has been used to identify specific nucleotide sequences in plasmid DNA molecules. This was accomplished using EcoRI (Gln-111), a mutant of the restriction enzyme that has a 1000-fold greater binding affinity than the wild-type enzyme but with cleavage rate constants reduced by a factor of 10(4). ScaI-linearized plasmids with single (pBS+) and double (pGEM-luc and pSV-beta-galactosidase) EcoRI recognition sites were imaged, and the bound enzyme was localized to a 50- to 100-nt resolution. The high affinity for the EcoRI binding site exhibited by this mutant endonuclease, coupled with an observed low level of nonspecific binding, should prove valuable for physically mapping large DNA clones by direct atomic force microscope imaging.

Binding Sites↗

Stretched DNA structures observed with atomic force microscopy.

Double-stranded DNA molecules are occasionally found that appear to be straightened and stretched in atomic force microscope (AFM) images. Usually pBS+ plasmid and lambda DNA show relaxed structures with bends and kinks along the strands and have measured contour lengths consistent to about 5-7%; they also appear not to cross over each other, except in very high concentrations. The anomalous molecules observed here, compared with the majority of molecules in the preparation, show contour lengths increased by as much as 80% and have measured heights of about half that of normal relaxed DNA. Some molecules also appear to be in transition between stretched and relaxed forms. These observations are consistent with an uncoiling of the DNA helix without breakage of the covalent bonds in the deoxyribose-phosphate backbone.

Bacteriophage lambda↗

Immobilization of DNA for scanning probe microscopy.

Reproducible scanning tunneling microscope and atomic force microscope images of entire molecules of uncoated plasmid DNA chemically bound to surfaces are presented. The chemically mediated immobilization of DNA to surfaces and subsequent scanning tunneling microscope imaging of DNA molecules demonstrate that the problem of molecular instability to forces exerted by the probe tip, inherent with scanning probe microscopes, can be prevented.

DNA, Bacterial↗

Electrostatic spraying of DNA molecules for investigation by scanning tunneling microscopy.

We have investigated electrostatic spraying of DNA onto gold surfaces as an alternative sample-preparation technique for STM studies. Preliminary results show that a higher distribution of isolated strands as well as well ordered aggregates can be obtained with this technique when compared with electrodeposition or drop evaporation. In many places, the well ordered aggregates were found to cleave in a direction perpendicular to their length after repeated scanning in the same direction.

DNA↗

Scanning tunneling microscopy of DNA: a novel technique using radiolabeled DNA to evaluate chemically mediated attachment of DNA to surfaces.

pBS+ plasmid deoxyribonucleic acid (DNA) was imaged by scanning tunneling microscopy (STM) after mounting microdroplets by aerosol deposition onto heated epitaxial gold surfaces. However, the instability of the adsorbate to forces exerted by the tunneling tip points out the need for more aggressive bonding of molecules to surfaces. We describe a sensitive assay for the qualitative and quantitative evaluation of chemical agents to influence binding of DNA to surfaces using 32P-labeled pBS+ plasmid DNA. We propose that such an assay can make an important contribution to immobilization techniques prior to STM imaging.

DNA↗

Imaging isolated strands of DNA molecules by atomic force microscopy.

We have employed an atomic force microscope (AFM) to image in air isolated strands of pBS+ plasmid DNA adsorbed onto freshly cleaved mica. At a DNA concentration below 0.3 micrograms/ml isolated strands of the plasmid DNA are usually seen, while for concentrations higher than 3 micrograms/ml a uniform coverage of interconnected DNA strands was observed. We found that the contrast and the width of DNA were dependent upon humidity. When the relative humidity exceeds 60%, negative contrast images with strand widths 20 times the width of DNA are found, while positive contrast images with 7 to 10 times the width of DNA are found when the humidity is below 30%. By placing the AFM in an environment where the humidity could be controlled, we were able to switch between positive and negative contrasts.

Adsorption↗

Atomic force microscopy of DNA on mica and chemically modified mica.

Atomic force microscopy (AFM) was used to image circular DNA adsorbed on freshly cleaved mica and mica chemically modified with Mg(II), Co(II), La(III), and Zr(IV). Images obtained on unmodified mica show coiling of DNA due to forces involved during the drying process. The coiling or super twisting appeared to be right handed and the extent of super twisting could be controlled by the drying conditions. Images of DNA observed on chemically modified surfaces show isolated open circular DNA that is free from super twisting, presumably due to strong binding of DNA on chemically modified surfaces.

Adsorption↗

Electrochemical deposition of molecular adsorbates for in situ scanning probe microscopy.

We have studied gold and graphite electrodes in an electrochemistry cell under various solutions using the scanning tunneling microscope (STM). The gold (111) surface yields quite reproducible images and cyclic voltammograms. In situ voltammograms show that, under certain conditions, nanomolar quantities of DNA fragments can suppress the adsorption of a buffer salt of millimolar concentration. When the DNA concentration is reduced below that required for a monolayer coverage, the salt adsorption is restored. We show images of bare gold, gold covered with an adsorbate produced by the buffer salt, and gold prepared with a concentration of DNA fragments close to that required for monolayer coverage added to the buffer. Under these conditions, the surface is found to be uniformly covered with a characteristic structure.

Adsorption↗

Images of the DNA double helix in water.

The scanning tunneling microscope can image uncoated DNA submerged in water. The grooves of the double helix were clearly resolved in images of the 146-base pair fragment extracted from calf thymus nucleosome. In contrast to images obtained with dry DNA, the helix pitch varied only a small amount (36 +/- 5 angstroms). The path of the helix shows considerable variation. It is quite straight when the molecules are densely packed, but it curves and bends in isolated molecules.

Animals↗

STM and AFM images of nucleosome DNA under water.

We have imaged DNA from the calf thymus nucleosome using a scanning tunneling microscope (STM) operated in water. The fragments are deposited onto the interface between a buffer solution and an epitaxially grown gold surface using an electrochemical tecnique. Most of the fragments are fairly straight, and when individual polymers can be identified, their length is consistent with the expected 146 basepairs (approximately 500 A). The resolution is often adequate to show signs of the 36 A helical pitch. Some images show a structure which appears to have abrupt kinks of the sort predicted by Crick and Klug (Nature 255, 530-533, 1975). In order to check that this shape is not a consequence of binding to underlying structure on the gold substrate, we have also made images of kinked structures using an atomic force microscope (AFM) with the DNA bound to glass.

Animals↗

Sequence, packing and nanometer scale structure in STM images of nucleic acids under water.

Scanning tunneling microscope (STM) images of random-sequence nucleic acid polymers under water show internal structure which depends strongly on the packing density of the polymer. Images of dense aggregates have a semicrystalline order with the individual polymers adopting simple periodic structures. Loose aggregates (or isolated molecules) show structural variability with considerable local bending and curving on a nanometer scale. It is not clear to what extent this structure is induced by the operation of the microscope. In order to investigate the possibility that the structure is sequence directed, we have imaged various DNA and RNA polymers at low packing densities. We present results here for random sequence DNA, poly(dAT).poly(dAT), poly(dA).poly(dT), poly(dCG).poly(dCG) and for random sequence RNA and poly(U). In contrast to loose aggregates of the random sequence material, the homopolymers show few sharp bends. Furthermore, the homopolymers appear to yield characteristic backbone patterns, usually at resolutions in excess of that obtained with random sequence polymers. The random sequence polymers show much more evidence of image distortion due to tip-molecule interactions, suggesting that they are, on average, mechanically less stable in the STM tunnel-gap than the homopolymers. Thus, while some of the structure observed in STM images is a consequence of tip-molecule interactions, it is related to sequence-directed properties of the polymer.

DNA↗