Search PubMed⌕ Search

Biomedical subjects

T Takano

Publications and source records attributed to T Takano.

At least 109 records · Page 6Linked to original sources

Analysis of posterior mitral annular activation during entrainment and catheter ablation of mitral isthmus ventricular tachycardia using a coronary sinus catheter.

A detailed analysis of the ventricular activation along the posterior aspect of the mitral annulus was made using a multipolar catheter positioned in the coronary sinus in a patient with mitral isthmus ventricular tachycardia (VT) associated with a remote inferior myocardial infarction and prior cryosurgical ablation for the elimination of a different preexisting VT. A change in the timing and sequence of the ventricular activation along the isthmus could be observed during induction of the VT and entrainment pacing. A radiofrequency (RF) current application directed at the posterolateral region of the isthmus successfully eliminated this tachycardia. During the RF delivery, complete conduction block was confirmed by a sudden change in the activation sequence during sinus rhythm.

Aged↗

Complement-induced phospholipase A2 activation in experimental membranous nephropathy.

BACKGROUND: In the passive Heymann nephritis (PHN) model of membranous nephropathy, C5b-9 induces glomerular epithelial cell (GEC) injury and proteinuria, which is partially mediated by eicosanoids. By analogy, in cultured rat GEC, sublytic C5b-9 injures plasma membranes and releases arachidonic acid (AA) and eicosanoids, due to activation of phospholipase A2 (PLA2). This study addresses the mechanisms of PLA2 activation. METHODS: PLA2 expression was assessed with the polymerase chain reaction or immunoblotting, and activity was determined using an in vitro assay or by measurement of free AA. RESULTS: Under basal conditions, GEC in culture expressed a relatively low level of cytosolic PLA2 (cPLA2) protein, while mRNAs of groups IB, IIA and V secretory PLA2s (sPLA2) were not detectable. Incubation of GEC with sublytic C5b-9 induced 1.5- to 2.0-fold increases in free [3H]AA at 40 minutes, and three and 24 hours. C5b-9 did not increase cPLA2 protein, and did not induce group IB, IIA or V sPLA2 mRNAs. Stable overexpression of cPLA2 in GEC amplified the C5b-9-induced increases in free [3H]AA, while analogous overexpression of group IIA sPLA2 had no effect. PLA2 activity was increased in glomeruli of rats with PHN, and this enhanced activity was characterized as cPLA2. There were no differences in cPLA2 protein expression between PHN and control glomeruli. CONCLUSIONS: Release of AA by C5b-9 in GEC in culture and in vivo is mediated by cPLA2, and the mechanism is consistent with post-translational regulation of cPLA2 activity. C5b-9 does not induce expression or stimulate activity of sPLA2 isoforms in GEC.

Animals↗

Analysis of the arterial blood pressure waveform using Fast Fourier Transform technique during left ventricular nonpulsatile assistance: in vitro study.

The arterial blood pressure waveform is variable during left ventricular assistance. The aim of this study is to examine the correlation between the left ventricular assist device (LVAD) condition and the arterial blood pressure waveform in a fixed cardiac output condition using a mock circuit. This mock circulation loop was composed of an aortic compliance chamber, a left atrial compliance chamber, a pneumatic pulsatile pump as a native heart, and a rotary blood pump representing the LVAD with left atrial drainage. The Fast Fourier Transform technique was utilized to analyze the arterial blood pressure waveform and calculate the pulsatility index (PI) and the pulse power index (PPI). The PI and PPI decreased with the increase of the LVAD rotational speed, exponentially. There was a significant negative correlation between the PI, PPI, and the LVAD rotational speed, flow rate, and assist ratio. The best correlation was observed between the PPI and the assist ratio (r = 0.986). From this viewpoint, an ideal LVAD condition may be estimated from the pulsatility change of the arterial blood pressure waveform.

Blood Pressure↗

Estimation of pump flow rate and abnormal condition of implantable rotary blood pumps during long-term in vivo study.

The control system for an implantable rotary blood pump is not clearly defined. A detection system is considered to be necessary for pump flow monitoring and abnormal conditions such as back flow or a sucking phenomenon where the septum or left ventricle wall is sucked into the cannula, etc. The ultrasound flowmeter is durable and reliable but the control system should not be totally dependent on the flowmeter. If the flowmeter breaks, the rotary blood pumps have no control mechanism. Therefore, the authors suggest controlling the pumps by an intrinsic parameter. One left ventricular assist device (LVAD) calf model was studied where the flow rate and waveform of the pump flow proved to identify the sucking phenomenon. Thus, the pump flow rate was calculated from the required power, motor speed, and heart rate. The value of the coefficient of determination (R2) between the measured and estimated pump flow rate was 0.796. To estimate this abnormal phenomenon, 2 methods were evaluated. One method was the total pressure head in which the pump flow rate and motor speed were estimated. During normal conditions the total pressure head is 79.5 +/- 7.0 mm Hg whereas in the abnormal condition, it is 180.0 +/- 2.8 mm Hg. There was a statistical difference (p < 0.01). Another method is using a current waveform. There is an association between the current and pump flow waves. The current was differentiated and squared to calculate the power of the differentiated current. The normal range of this value was 0.025 +/- 0.029; the abnormal condition was 11.25 +/- 15.13. There was a statistical difference (p < 0.01). The predicted flow estimation method and a sucking detection method were available from intrinsic parameters of the pump and need no sensors. These 2 methods are simple, yet effective and reliable control methods for a rotary blood pump.

Animals↗

Right ventricular assist system feedback flow control parameter for a rotary blood pump.

At least 25-30% of patients with a permanent implantable left ventricular assist device (LVAD) experience right ventricular failure; therefore, an implantable biventricular assist system (BiVAS) with small centrifugal pumps is being developed. Many institutions are focusing and developing a control system for a left ventricular assist system (LVAS) with rotary blood pumps. These authors feel that the right ventricular assist system (RVAS) with rotary blood pumps should be developed simultaneously. A literature search indicated no recent reports on the effect of hemodynamics and exercise with this type of nonpulsatile implantable RVAS. In this study, a calf with an implantable right ventricular assist system (RVAS) was subjected to 30 min of exercise on a treadmill at 1.5 mph, resulting in excellent hemodynamics. The input voltage remained unchanged. Hemodynamic recordings were taken every 5 min throughout the testing period, and blood gas analysis was done every 10 min. Oxygen uptake (VO2), oxygen delivery (DO2), and oxygen extraction (O2ER) were calculated and analyzed. Two different pump flows were investigated: Group 1 low assist (<3.5 L/min) and Group 2 high assist (>3.5 L/min). In both groups, the RVAS flow rates were unchanged while the pulmonary artery (PA) flow increased during exercise; also, the heart rate and right atrial pressure (RAP) increased during exercise. There were no significant differences in the 2 groups. The PA flow correlates to the heart rate during exercise. In all of the tests, the VO2 and DO2 increased during exercise. Regarding VO2, no changes were observed during the different flow conditions; however, the DO2 of Group 2 was higher than that of Group 1. Because the implantable RVAS did not have pump flow changes during the test conditions, it was necessary to incorporate a flow control system for the implantable RVAS. During exercise with an implantable RVAS rotary blood pump, incorporating the heart rate and VO2 as feedback parameters is feasible for controlling the flow rate.

Animals↗

Development of the NEDO implantable ventricular assist device with Gyro centrifugal pump.

The Gyro centrifugal pump, PI (permanently implantable) series, is being developed as a totally implantable artificial heart. Our final goal is to establish a "functional TAH," a totally implantable biventricular assist system (BiVAS) with centrifugal pumps. A plastic prototype pump, Gyro PI 601, was evaluated through in vitro and in vivo studies as a single ventricular assist device (VAD). Based upon these results, the pump head material was converted to a titanium alloy, and the actuator was modified. These titanium Gyro pumps, PI 700 series, also were subjected to in vitro and in vivo studies. The Gyro PI 601 and PI 700 series have the same inner dimensions and characteristics, such as the eccentric inlet port, double pivot bearing system, secondary vane, and magnet coupling system; however, the material of the PI 700 is different from the PI 601. The Gyro PI series is driven by the Vienna DC brushless motor actuator. The inlet cannula of the right ventricular assist system (RVAS) specially made for this system consists of 2 parts: a hat-shaped silicone tip biolized with gelatin and an angled wire reinforced tube made of polyvinylchloride. The pump-actuator package was implanted into 8 calves in the preperitoneal space, bypassing from the left ventricle apex to the descending aorta for the left ventricular assist system (LVAS) and bypassing the right ventricle to the main pulmonary artery for the RVAS. According to the PI 601 feasibility protocol, 2 LVAS cases were terminated after 2 weeks, and 1 LVAS case and 1 RVAS were terminated after 1 month. The PI 700 series was implanted into 4 cases: 3 LVAS cases survived for a long term, 2 of them over 200 days (72-283 days), and 1 RVAS case survived for 1 month and was terminated according to the protocol for a short-term antithrombogenic screening and system feasibility study. Regarding power consumption, the plastic pump cases demonstrated from 6.2 to 12.1 W as LVAS and 7.3 W as RVAS, the titanium pump cases showed from 10.4 to 14.2 W as LVAS and 15.8 W as RVAS. All cases exhibited low hemolysis. The renal function and the liver function were maintained normally in all cases throughout these experimental periods. In the 2 RVAS cases, pulmonary function was normally maintained. No calves demonstrated thromboembolic signs or symptoms throughout the experiments except Case 1 with the plastic pump. However, in the plastic pump cases, bilateral renal infarction was suspected in 2 cases during necropsy whereas no abnormal findings were revealed in the titanium pump cases. There were also no blood clots inside the PI 700 series. As for the 601, the explanted pumps demonstrated slight thrombus formations at the top and bottom pivots except in 1 case. The Gyro PI series, especially the PI 700 series, demonstrated superior performance, biocompatibility, antithrombogenicity and low hemolysis. Also, the durability of the actuator was demonstrated. Based on these results, this titanium centrifugal pump is suitable as an implantable LVAS and RVAS. It is likely that the Gyro PI series is a feasible component of the BiVAS functional TAH.

Animals↗

Gyro pump wear and deformation analysis in vivo study: creep deformation.

The Gyro pump has a double pivot bearing system to support its impeller. In this study, the integrity of the bearing system was examined after ex vivo studies. The pumps were implanted into calves and evaluated for different periods as a paracorporeal left ventricular assist device (LVAD). One pump was subjected to a test of 30 days, 1 for 15 days, 4 for 14 days, 1 for 10 days, 1 for 7 days, 2 for 4 days, and 4 for 2 days. One additional pump was subjected to percutaneous cardiopulmonary support (PCPS) condition for 6 days (total pressure head 500 mm Hg with a pump flow rate of 3 L/min). The anticoagulation treatment consisted of a continuous administration of heparin to maintain an achieved clotting time (ACT) of 200-250 s during the LVAD study and 250-300 s during the PCPS study. After the experiment, the pumps were disassembled, and the wear and deformation of male and female bearings were analyzed. There were no dimensional changes on male bearings but there were on female bearings. Wear and deformation of the female bearings were calculated as follows: wear and deformation = (depth of female before pumping) - (depth after pumping). Thirteen assembled Gyro pumps were disassembled to measure the depth of the female bearings before pumping. There was no statistical relationship between the wear and deformation and the motor speed x driving period. From these results, the deformation was not due to wear but to the creep or elastic deformation. This study suggested that the double pivot bearing system of the Gyro pump is highly durable.

Animals↗

Antithrombogenicity evaluation of a centrifugal blood pump.

The Gyro C1E3 pump was developed not only for cardiopulmonary bypass but also as a short-term assist device. The main purpose of this study was to examine the correlation between the thrombus formation factor and the Gyro C1E3 pumps. Seven pumps were implanted into 3 calves and evaluated for different periods of duration as a paracorporeal left ventricular assist device (LVAD). One pump was subjected to percutaneous cardiopulmonary support condition (PCPS) (total pressure head 500 mm Hg with a pump flow rate of 3 L/min). The anticoagulation treatment consisted of a continuous administration of heparin to maintain an activated clotting time (ACT) of 200-250 during the LVAD study and 250-300 during the PCPS study. After the experiment, the pumps were disassembled and examined. In cases where there were any blood-derived deposits inside the pumps, the dry weight of these thrombi that adhered to the bearing area of the pump was measured. A multiple correlation was attempted to speculate possible thrombus formation. The estimated dry weight of thrombi was calculated from pump flow rate, pumping day, motor speed, and activated clotting time. This equation was estimated dry weight of thrombi = 1.140 x pump flow rate -0.001 motor speed + 1.652 pumping time -0.041 x ACT + 2.198 R2 = 0.944. This study suggested that there was a possibility to calculate the amount of adhered thrombus formation from pump flow rate, motor speed, pumping day, and ACT.

Animals↗

Particles released from the Gyro C1E3 during simulated extracorporeal circulation.

Evaluation of released particles from the blood pump during extracorporeal circulation is an important aspect because the particles may cause microembolism. The Gyro C1E3 is a centrifugal blood pump that has an impeller suspended by double pivot bearings inside the housing; therefore, it is important to evaluate the released particles. The C1E3 was driven for 14 days to simulate clinical left ventricular assist device (LVAD) and percutaneous cardiopulmonary support (PCPS). Also, a roller pump was driven for 2 days as a comparison. Released particles were weighed and examined by SEM. After 14 days of pumping, the particles from the C1E3 were 238.6 microg in an LVAD condition. The particles with the roller pump were 270.2 microg after only 2 days. Average particle sizes with the roller pump and C1E3 were 3.7 and 0.6 microm, respectively. These results suggest that the Gyro C1E3 substantially reduces the risk of microembolism from released particles.

Biocompatible Materials↗

Impeller design for a miniaturized centrifugal blood pump.

The impeller design for a miniature centrifugal blood pump is an important consideration since the small diameter impeller requires higher rotational speed, which may cause more blood trauma compared to the larger diameter impeller. Three different impeller vanes (straight vanes with a height of 4 mm and 8 mm, and 8 mm curved vanes) of which the diameter was 35 mm were subjected to hydraulic performance and hemolysis tests in the same pump housing. Both straight vane impellers attained left ventricular assist condition (5 L/min against 100 mm Hg) at 2,900 rpm while the curved vane required 3,280 rpm. There was no significant hemolysis difference between the tall and short vanes. The curved impeller vanes did not exhibit sufficient hydraulic performance when compared to the straight vanes. The straight vane impellers, even with different heights, were incorporated into the same pump housings, and the vane heights did not drastically change the hydraulic performance or hemolysis.

Equipment Design↗

Development of rotary blood pump technology: past, present, and future.

Even though clinical acceptance of a nonpulsatile blood flow was demonstrated almost 45 years ago, the development of a nonpulsatile blood pump was completely ignored until 20 years ago. In 1979, the first author's group demonstrated that completely pulseless animals did not exhibit any abnormal physiology if 20% higher blood flows were provided to them. However, during the next 10 years (1979-1988), minimum efforts were provided for the development of a nonpulsatile, permanently implantable cardiac prosthesis. In 1989, the first author and his team at Baylor College of Medicine initiated a developmental strategy of various types of nonpulsatile rotary blood pumps, including a 2-day rotary blood pump for cardiopulmonary bypass application, a 2 week pump for ECMO and short-term circulatory assistance, a 2 year pump as a bridge to transplantation, and a permanently implantable cardiac prosthesis. Following the design and developmental strategy established in 1989, successful development of a 2-day pump (the Nikkiso-Fairway cardiopulmonary bypass pump) in 4 years (1989-1993), a 2 week pump (Kyocera gyro G1E3 pump) in 6 years (1992-1998), and a bridge to transplant pump (DeBakey LVAD-an axial flow blood pump) in 10 years (1988-1998) was made. Currently, a permanently implantable centrifugal blood pump development program is successfully completing its initial Phase 1 program of 5 years (1995-2000). Implantation exceeded 9 months without any negative findings. An additional 5 year Phase II program (2000-2005) is expected to complete such a device that will be clinically available.

Cardiac Surgical Procedures↗

Analysis of the arterial blood pressure waveform during left ventricular nonpulsatile assistance in animal models.

When the rotary blood pump is used as a left ventricular assist device (LVAD), the arterial blood pressure waveform changes with the LVAD condition. Based on evidence from an in vitro study, the change of the arterial blood pressure waveform during left ventricular assistance was evaluated using animal models. After the left pleural cavity was opened through the fifth intercostal space under general anesthesia, a rotary blood pump was implanted as an LVAD into 6 healthy calves. The direct left carotid arterial blood pressure waveform was measured and recorded by an oscilloscope. The Fast Fourier Transform technique was utilized to analyze the arterial blood pressure waveform and calculate the pulsatility index (PI) and the pulse power index (PPI). Similar to the in vitro study, the PI and PPI decreased exponentially with the increase of the LVAD assist ratio. By using this analysis methodology, a physiologically effective ventricular assistance might be achieved.

Animals↗

Temporal and spatial dispersion of repolarization during premature impulse propagation in human intact ventricular muscle: comparison between single vs double premature stimulation.

AIMS: This study was performed to determine whether or not the kinetics of action potential duration restitution during double premature stimuli (S3) differ from that during single premature stimuli (S2) in the human intact right ventricle. METHODS AND RESULTS: A monophasic action potential (MAP) was simultaneously recorded from the right ventricular apex (RVA) and outflow tract (RVOT) during programmed ventricular pacing in 11 patients with symptomatic bradyarrhythmias (five males, six females, mean age 58 years). In the five most recent patients, the RV pressure and its dp/dt were also obtained during the protocol. A substantial difference in the restitution of the MAP duration (MAPD) between S2 and S3 was observed at short diastolic intervals (< l00 ms), that is, the restitution curve of S2 showed an early biphasic pattern (upward hump), while such a phenomenon was not seen during the restitution of S3. All the quantitative parameters of MAPD restitution representing its kinetics were significantly greater in S3 than S2. Maximum attainable dispersion of repolarization between the two MAPs was significantly greater during S3 than S2 (76 +/- 17 vs 59 +/- 17 ms, P<0.05) and was mainly caused by the difference in the MAPD difference, thus by the difference in the restitution kinetics of S2 and S3. The dp/dt of the RV pressure was significantly greater during S3 than S2 for all diastolic intervals tested. CONCLUSION: It was concluded that similar to previously reported canine experimental studies, the APD restitution of S3 is substantially different from that of S2 in the human intact ventricle (endocardium).

Action Potentials↗

A variant form of Churg-Strauss syndrome: initial temporal non-giant cell arteritis followed by asthma--is this a distinct clinicopathologic entity?

The clinical manifestations of the classical vasculitis syndromes are extraordinarily heterogenous with considerable overlap among them. Recently, several cases of unusual presentation of the vasculitis syndromes have been reported. We describe a patient who initially manifested with temporal arteritis and Raynaud's phenomenon and subsequently developed bronchial asthma, ie, a case of an atypical form of Churg-Strauss syndrome (allergic angiitis and granulomatosis) and discuss whether this case is a distinct clinicopathological entity.

Adult↗

Gene expression profiles in thyroid carcinomas.

The gene expression profiles of human thyroid carcinomas were analysed by serial analysis of gene expression (SAGE) which allows quantitative and simultaneous analysis of a large number of transcripts. More than 29,000 transcripts derived from a normal thyroid tissue and four thyroid tumours were analysed. While extensive similarity was noted between the expression profiles of the normal thyroid tissue and three differentiated thyroid tumours, many transcripts, such as osteonectin, a-tubulin, glyceraldehyde-3-phosphate dehydrogenase, glutathione peroxidase, and thyroglobulin, were expressed at extremely different levels in differentiated and undifferentiated carcinomas. These data provide new information that might be used to identify genes useful for the diagnosis and treatment of thyroid carcinomas.

Adenoma↗

Distinctive functions of Syk N-terminal and C-terminal SH2 domains in the signaling cascade elicited by oxidative stress in B cells.

Syk plays a crucial role in the transduction of oxidative stress signaling. In this paper, we investigated the roles of Src homology 2 (SH2) domains of Syk in oxidative stress signaling, using Syk-negative DT40 cells expressing the N- or C-terminal SH2 domain mutant [mSH2(N) or mSH2(C)] of Syk. Tyrosine phosphorylation of Syk in cells expressing mSH2(N) Syk after H(2)O(2) treatment was higher than that in cells expressing wild-type Syk or mSH2(C) Syk. The tyrosine phosphorylation of wild-type Syk and mSH2(C) Syk, but not that of mSH2(N), was sensitive to PP2, a specific inhibitor of Src-family protein-tyrosine kinase. In oxidative stress, the C-terminal SH2 domain of Syk was demonstrated to be required for induction of tyrosine phosphorylation of cellular proteins, phospholipase C (PLC)-gamma2 phosphorylation, inositol 1,4, 5-triphosphate (IP(3)) generation, Ca(2)(+) release from intracellular stores, and c-Jun N-terminal kinase activation. In contrast, in mSH2(N) Syk-expressing cells, tyrosine phosphorylation of intracellular proteins including PLC-gamma2 was markedly induced in oxidative stress. The enhanced phosphorylation of mSH2(N) Syk and PLC-gamma2, however, did not link to Ca(2)(+) mobilization from intracellular pools and IP(3) generation. Thus, the N- and C-terminal SH2 domains of Syk possess distinctive functions in oxidative stress signaling.

Animals↗

Myocardial dysfunction associated with proinflammatory cytokines after esophageal resection.

UNLABELLED: Proinflammatory cytokines have been implicated in mediating myocardial dysfunction associated with major surgery. We investigated the profile of proinflammatory cytokines and the association of cytokine levels with myocardial function after esophagectomy. We studied 12 patients who underwent subtotal esophagectomy. One patient died of multiple organ failure. This patient had the largest interleukin-6 (IL-6) level of all the subjects. IL-6 levels increased from 14.9 +/- 8.7 pg/mL to 498.4 +/- 294.3 pg/mL (P < 0.05) at 6 h postoperatively. Interleukin-8 (IL-8) levels also significantly increased postoperatively. Right ventricular ejection fraction (RVEF) decreased from 44% +/- 1% to 36% +/- 2% (P < 0.05) and 37% +/- 2% (P < 0.05) at 6 h and 12 h postoperatively. Stroke volume index (SVI) decreased significantly at the end of operation and at 6 h and 12 h postoperatively. The changes of RVEF and SVI showed an independent negative correlation with the IL-6 level (r = -0.70, P < 0.001 and r = -0.62, P < 0.001, respectively). In contrast, the change of RVEF and SVI was not correlated with the IL-8 level. Esophagectomy is associated with transient depression of myocardial function. IL-6 may contribute to this postoperative myocardial dysfunction. IMPLICATIONS: We examined the association between myocardial function and proinflammatory cytokines after esophagectomy. Interleukin-6 may be the cytokine that most sensitively reflects the postoperative myocardial dysfunction.

Carcinoma, Squamous Cell↗

Alpha-human atrial natriuretic peptide, carperitide, reduces infarct size but not arrhythmias after coronary occlusion/reperfusion in dogs.

Carperitide, a recombinant form of alpha-hANP, possesses potent diuretic, natriuretic, and vasodilatory activity, and inhibits the renin-aldosterone system and sympathetic nervous activity. However, its beneficial effects on ischemic myocardium have not been studied fully. We examined carperitide's effects on infarct size, hemodynamics, and arrhythmia frequency in anesthetized dogs (n = 20) subjected to a 90-min coronary artery occlusion/6-h reperfusion protocol. Intravenous infusion of carperitide (0.2 microg/kg/min) commenced 15 min after occlusion and continued during occlusion/reperfusion. Ventricular fibrillation developed in two of 10 control versus three of 10 treated dogs (p = NS). Hemodynamics, collateral blood flow to the ischemic wall measured 10 min after occlusion, and extent of area at risk were comparable for the two groups. Infarct size/area at risk was smaller in treated than in control dogs (4.5 +/- 2.1% vs. 27.8 +/- 7.8%, respectively; p < 0.05). During occlusion, carperitide tended to increase collateral blood flow (+39%) and significantly decreased left ventricular systolic pressure (-13%) and end-diastolic pressure (-40%) compared with baseline. In control dogs, collateral blood flow tended to decrease (-8.3%), whereas most hemodynamic parameters did not change significantly with respect to baseline. The number of arrhythmias recorded during occlusion/reperfusion was similar in the two groups. Intravenous administration of carperitide limited infarct size, but did not reduce incidence of ventricular arrhythmias after 90-min coronary occlusion/6-h reperfusion in anesthetized dogs. Although the beneficial effects of carperitide may be attributable to concomitant changes in hemodynamics and collateral blood flow, the precise mechanisms require further investigation.

Animals↗