Digital speech processing for cochlear implants.

A rather general basic working hypothesis for cochlear implant research might be formulated as follows. Signal processing for cochlear implants should carefully select a subset of the total information contained in the sound signal and transform these elements into those physical stimulation parameters which can generate distinctive perceptions for the listener. Several new digital processing strategies have thus been implemented on a laboratory cochlear implant speech processor for the Nucleus 22-electrode system. One of the approaches (PES, pitch excited sampler) is based on the maximum peak channel vocoder concept whereby the spectral energy of a number of frequency bands is transformed into appropriate electrical stimulation parameters for up to 22 electrodes using a voice pitch synchronous pulse rate at any electrode. Another approach (CIS, continuous interleaved sampler) uses a maximally high pitch-independent stimulation pulse rate on a selected number of electrodes. As only one electrode can be stimulated at any instance of time, the rate of stimulation is limited by the required stimulus pulse widths (as determined individually for each subject) and some additional constraints and parameters which have to be optimized and fine tuned by psychophysical measurements. Evaluation experiments with 5 cochlear implant users resulted in significantly improved performance in consonant identification tests with the new processing strategies as compared with the subjects own wearable speech processors whereas improvements in vowel identification tasks were rarely observed. The pitch-synchronous coding (PES) resulted in worse performance compared to the coding without explicit pitch extraction (CIS).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult

Comparison of hearing aids and cochlear implants in profoundly and totally deaf persons.

Cochlear implants are increasingly used in the rehabilitation of the profoundly and totally deaf. Usually, insufficient gain of speech discrimination with a powerful conventional hearing aid is considered as a prerequisite for a cochlear prosthesis. With recent improvements of electronic systems, the criterion for this decision may change. To keep pace with the technical progress, a battery of speech sound tests suited for minimal auditory capabilities (MAC-battery) was developed and applied to groups of patients fitted with conventional instruments and with two different types of cochlear implants. Based on the comparison of the MAC-battery results of hearing aid groups, with the average performance of an implanted group, most conventionally fitted regular users of hearing aids should not be considered as candidates for cochlear implantation. The MAC-battery, although not a strictly standardized procedure, is a useful instrument for patient counselling and for the selection of implant candidates.

Adolescent

[The prognostic value in tympanoplasty surgery of eustachian tube function tests (author's transl)].

A study was undertaken to test the validity of preoperative Eustachian tube ventilation measurements in 107 patients with conductive deafness and chronic middle ear disease. By standard static aspiration and deflation tests and with the Valsalva probe correlations were found in some patients between tubal function and the extent of middle ear damage as shown by the air-bone gap on audiometry and the findings at operation. However no prognostic information was evident with these measures since no relationship existed between tubal function and operative success as judged by closure of the air-bone gap or by healing of the tympanic membrane defect.

Ear Diseases

[Electrical stimulation of hearing in humans: a survey of the actual state of development of an implantable prosthesis for sensorineural deafness (author's transl)].

Recent clinical results show that electrical excitation of hearing sensations with implanted electrodes in the inner ear can be successful in suitable deaf persons. A critical literature review shows that some results have been described too vaguely and that there still exist numerous methodical and technical deficiencies. Even with multichannel stimulation, true tonotopical hearing could not be achieved. Periodicity hearing alone is not sufficient for the discrimination of one-syllable words. However, most deaf persons fitted with surgically implanted electrodes judged the new hearing sensations as being agreeable and quite useful. There seem to be no long term harmful effects of these implants upon the state of the acoustic nerve. However there are still a series of basic questions in auditory physiology pending which can only be solved through intensive collaboration of the clinical disciplines involved.

Animals