Search PubMed⌕ Search

Biomedical subjects

T Shiota

Publications and source records attributed to T Shiota.

At least 37 records · Page 2Linked to original sources

Cosgrove-Edwards Annuloplasty System: midterm results.

BACKGROUND: The Cosgrove-Edwards Annuloplasty System includes a universally flexible band that corrects mitral annular dilatation via measured plication of the posterior annulus. The purpose of this study was to evaluate midterm clinical and functional results in the first 197 patients receiving this flexible annuloplasty band at mitral valve repair. METHODS: From February 1993 to July 1994, 197 consecutive patients with mitral regurgitation had mitral valve repair using this system. Valve disease was degenerative in 73%, rheumatic in 15%, ischemic in 5%, infectious in 2.5%, and other in 4%. RESULTS: Immediately after repair, echocardiographic mitral regurgitation was none or trivial in 92%, 1+ in 5%, and 2+ in 3%. There were no hospital deaths. Late follow-up was available in 195 patients (99%), with 661 patient-years of follow-up available for analysis. Four-year actuarial survival was 93%, freedom from thromboembolism 94%, from endocarditis 98%, and from reoperation 95%. At a mean interval of 18 months, echocardiography in 157 patients demonstrated no or trace mitral regurgitation in 56%, 1+ in 24%, 2+ in 9%, 3+ in 6%, and 4+ in 3%. At a mean of 61 +/- 5 months, reconstruction of the mitral annulus from real-time three-dimensional echocardiographic images in 10 patients confirmed preserved nonplanar shape and sphincter mechanism of the mitral annulus. Annular orifice area decreased 28% +/- 11% during the cardiac cycle from a mean of 10.1 +/- 3.9 cm2 in diastole to 7.2 +/- 2.8 cm2 in systole. CONCLUSIONS: This annuloplasty system is effective for repair of mitral regurgitation secondary to all causes and preserves mitral annular flexibility and function at 5-year follow-up.

Female↗

Validation of real-time three-dimensional echocardiography for quantifying left ventricular volumes in the presence of a left ventricular aneurysm: in vitro and in vivo studies.

OBJECTIVES: To validate the accuracy of real-time three-dimensional echocardiography (RT3DE) for quantifying aneurysmal left ventricular (LV) volumes. BACKGROUND: Conventional two-dimensional echocardiography (2DE) has limitations when applied for quantification of LV volumes in patients with LV aneurysms. METHODS: Seven aneurysmal balloons, 15 sheep (5 with chronic LV aneurysms and 10 without LV aneurysms) during 60 different hemodynamic conditions and 29 patients (13 with chronic LV aneurysms and 16 with normal LV) underwent RT3DE and 2DE. Electromagnetic flow meters and magnetic resonance imaging (MRI) served as reference standards in the animals and in the patients, respectively. Rotated apical six-plane method with multiplanar Simpson's rule and apical biplane Simpson's rule were used to determine LV volumes by RT3DE and 2DE, respectively. RESULTS: Both RT3DE and 2DE correlated well with actual volumes for aneurysmal balloons. However, a significantly smaller mean difference (MD) was found between RT3DE and actual volumes (-7 ml for RT3DE vs. 22 ml for 2DE, p = 0.0002). Excellent correlation and agreement between RT3DE and electromagnetic flow meters for LV stroke volumes for animals with aneurysms were observed, while 2DE showed lesser correlation and agreement (r = 0.97, MD = -1.0 ml vs. r = 0.76, MD = 4.4 ml). In patients with LV aneurysms, better correlation and agreement between RT3DE and MRI for LV volumes were obtained (r = 0.99, MD = -28 ml) than between 2DE and MRI (r = 0.91, MD = -49 ml). CONCLUSIONS: For geometrically asymmetric LVs associated with ventricular aneurysms, RT3DE can accurately quantify LV volumes.

Animals↗

New digital measurement methods for left ventricular volume using real-time three-dimensional echocardiography: comparison with electromagnetic flow method and magnetic resonance imaging.

AIM: The aim of this study was to investigate the feasibility and accuracy of using symmetrically rotated apical long axis planes for the determination of left ventricular (LV) volumes with real-time three-dimensional echocardiography (3DE). METHODS AND RESULTS: Real-time 3DE was performed in six sheep during 24 haemodynamic conditions with electromagnetic flow measurements (EM), and in 29 patients with magnetic resonance imaging measurements (MRI). LV volumes were calculated by Simpson's rule with five 3DE methods (i.e. apical biplane, four-plane, six-plane, nine-plane (in which the angle between each long axis plane was 90 degrees, 45 degrees, 30 degrees or 20 degrees, respectively) and standard short axis views (SAX)). Real-time 3DE correlated well with EM for LV stroke volumes in animals (r=0.68-0.95) and with MRI for absolute volumes in patients (r-values=0.93-0.98). However, agreement between MRI and apical nine-plane, six-plane, and SAX methods in patients was better than those with apical four-plane and bi-plane methods (mean difference = -15, -18, -13, vs. -31 and -48 ml for end-diastolic volume, respectively, P<0.05). CONCLUSION: Apically rotated measurement methods of real-time 3DE correlated well with reference standards for calculating LV volumes. Balancing accuracy and required time for these LV volume measurements, the apical six-plane method is recommended for clinical use.

Adult↗

Determination of left ventricular volume, ejection fraction, and myocardial mass by real-time three-dimensional echocardiography.

Reconstructed three-dimensional (3-D) echocardiography is an accurate and reproducible method of assessing left ventricular (LV) functions. However, it has limitations for clinical study due to the requirement of complex computer and echocardiographic analysis systems, electrocardiographic/respiratory gating, and prolonged imaging times. Real-time 3-D echocardiography has a major advantage of conveniently visualizing the entire cardiac anatomy in three dimensions and of potentially accurately quantifying LV volumes, ejection fractions, and myocardial mass in patients even in the presence of an LV aneurysm. Although the image quality of the current real-time 3-D echocardiographic methods is not optimal, its widespread clinical application is possible because of the convenient and fast image acquisition. We review real-time 3-D echocardiographic image acquisition and quantitative analysis for the evaluation of LV function and LV mass.

Cardiac Volume↗

Real-time 3D echocardiographic data analysis for left ventricular volume estimation.

A new computerized semi-automatic method for left ventricular chamber segmentation is presented. The left ventricle is imaged by real-time three-dimensional echocardiography. This real-time data acquisition method allows accurate evaluation of chamber size and shape, even in case there are cavities with irregular geometry. The surface detection model is based on a partial differential equation that propagates interfaces with curvature dependent speeds. The equation is solved by applying numerical methods for conservation laws. The method consists of one step only. Initial conditions are manually established on a small subset of slices of the entire volume. The solution obtained is a surface corresponding to the surface between LV cavity and LV endocardium. This mathematical model is applied to sequences of frames of human hearts (volume range: 34-109 ml) imaged by real-time 3D echocardiography. Volume estimates show an excellent correlation with those obtained by manual tracing (r=0.99).

Cardiac Volume↗

Compression of real time volumetric echocardiographic data using modified SPIHT based on the three-dimensional wavelet packet transform.

Real-time three-dimensional echocardiography has been introduced to provide improved quantification and description of cardiac function. Data compression is desired to allow efficient storage and improve data transmission. Previous work has suggested improved results utilizing wavelet transforms in the compression of medical data including 2D echocardiogram. Set partitioning in hierarchical trees (SPIHT) was extended to compress volumetric echocardiographic data by modifying the algorithm based on the three-dimensional wavelet packet transform. A compression ratio of at least 40:1 resulted in preserved image quality.

Aerospace Medicine↗

Impact of temporal resolution on flow quantification by real-time 3D color Doppler echocardiography: numerical modeling and animal validation study.

Real-time, 3D color Doppler echocardiography (RT3D) is capable of quantifying flow at the LV outflow tract (LVOT). However, previous works have found significant underestimation for flow rate estimation due to finite scanning time (ST) of the color Doppler. The authors have, therefore, developed a mathematical model to correct the impact of ST on flow quantification and validated it by an animal study. Scanning time to cover the entire cross-sectional image of the LVOT was calculated as 60 ms, and the underestimation due to temporal averaging effect was predicted as 18 +/- 7%. In the animal experiment, peak flow rates were obtained by spatially integrating the velocity data front the cross-sectional color images of the LVOT. By applying a correction factor, there was an excellent agreement between reference flow rate by an electromagnetic flow meter and RT3D (angstroms=-5.6 ml/s, r=0.93), which was significantly better than without correction (p<0.001). Real-time, color 3D echocardiography was capable of quantifying flow accurately by applying the mathematical correction.

Animals↗

Initial clinical experience of real-time three-dimensional echocardiography in patients with ischemic and idiopathic dilated cardiomyopathy.

The geometry of the left ventricle in patients with cardiomyopathy is often sub-optimal for 2-dimensional ultrasound when assessing left ventricular (LV) function and localized abnormalities such as a ventricular aneurysm. The aim of this study was to report the initial experience of real-time 3-D echocardiography for evaluating patients with cardiomyopathy. A total of 34 patients were evaluated with the real-time 3D method in the operating room (n = 15) and in the echocardiographic laboratory (n = 19). Thirteen of 28 patients with cardiomyopathy and 6 other subjects with normal LV function were evaluated by both real-time 3-D echocardiography and magnetic resonance imaging (MRI) for obtaining LV volumes and ejection fractions for comparison. There were close relations and agreements for LV volumes (r = 0.98, p <0.0001, mean difference = -15 +/- 81 ml) and ejection fractions (r = 0.97, p <0.0001, mean difference = 0.001 +/- 0.04) between the real-time 3D method and MRI when 3 cardiomyopathy cases with marked LV dilatation (LV end-diastolic volume >450 ml by MRI) were excluded. In these 3 patients, 3D echocardiography significantly underestimated the LV volumes due to difficulties with imaging the entire LV in a 60 degrees x 60 degrees pyramidal volume. The new real-time 3D echocardiography is feasible in patients with cardiomyopathy and may provide a faster and lower cost alternative to MRI for evaluating cardiac function in patients.

Cardiac Volume↗

New echocardiographic windows for quantitative determination of aortic regurgitation volume using color Doppler flow convergence and vena contracta.

Color Doppler images of aortic regurgitation (AR) flow acceleration, flow convergence (FC), and the vena contracta (VC) have been reported to be useful for evaluating severity of AR. However, clinical application of these methods has been limited because of the difficulty in clearly imaging the FC and VC. This study aimed to explore new windows for imaging the FC and VC to evaluate AR volumes in patients and to validate this in animals with chronic AR. Forty patients with AR and 17 hemodynamic states in 4 sheep with strictly quantified AR volumes were evaluated. A Toshiba SSH 380A with a 3.75-MHz transducer was used to image the FC and VC. After routine echo Doppler imaging, patients were repositioned in the right lateral decubitus position, and the FC and VC were imaged from high right parasternal windows. In only 15 of the 40 patients was it possible to image clearly and measure accurately the FC and VC from conventional (left decubitus) apical or parasternal views. In contrast, 31 of 40 patients had clearly imaged FC regions and VCs using the new windows. In patients, AR volumes derived from the FC and VC methods combined with continuous velocity agreed well with each other (r = 0.97, mean difference = -7.9 ml +/- 9.9 ml/beat). In chronic animal model studies, AR volumes derived from both the VC and the FC agreed well with the electromagnetically derived AR volumes (r = 0.92, mean difference = -1.3 +/- 4.0 ml/beat). By imaging from high right parasternal windows in the right decubitus position, complementary use of the FC and VC methods can provide clinically valuable information about AR volumes.

Adolescent↗

Three-dimensional reconstruction of the color Doppler-imaged vena contracta for quantifying aortic regurgitation: studies in a chronic animal model.

BACKGROUND: The purpose of this study was to investigate the use of 3-dimensional (3D) reconstruction of color Doppler flow maps to image and extract the vena contracta cross-sectional area to determine the severity of aortic regurgitation (AR) in an animal model. Evaluation of the vena contracta with 2-dimensional imaging systems may not be sufficiently robust to fully characterize this region, which may be asymmetrically shaped. METHODS AND RESULTS: In 6 sheep with surgically induced chronic AR, 18 hemodynamically different states were studied. Instantaneous regurgitant flow rates were obtained by aortic and pulmonary electromagnetic flowmeters (EMFs) as reference standards, and aortic regurgitant effective orifice areas (EOAs) were determined from EMF regurgitant flow rates divided by continuous-wave (CW) Doppler velocities. Composite video data for color Doppler imaging of the aortic regurgitant flows were transferred into a TomTec computer after computer-controlled 180 degrees rotational acquisition. After the 3D data transverse to the flow jet were sectioned, the smallest proximal jet cross section was identified for direct measurement of the vena contracta area. Peak regurgitant flow rates and regurgitant stroke volumes were calculated as the product of these areas and the CW Doppler peak velocities and velocity-time integrals, respectively. There was an excellent correlation between the 3D-derived vena contracta areas and reference EOAs (r=0.99, SEE=0.01 cm2) and between 3D and reference peak regurgitant flow rates and regurgitant stroke volumes (r=0.99, difference=0.11 L/min; r=0.99, difference=1.5 mL/beat, respectively). CONCLUSIONS: 3D-based determination of the vena contracta cross-sectional area can provide accurate quantification of the severity of AR.

Animals↗

Validation of the accuracy of both right and left ventricular outflow volume determinations and semiautomated calculation of shunt volumes through atrial septal defects by digital color Doppler flow mapping in a chronic animal model.

OBJECTIVES: The aim of the present study was to quantitate shunt flow volumes through atrial septal defects (ASDs) in a chronic animal model with surgically created ASDs using a new semiautomated color Doppler flow calculation method (ACM). BACKGROUND: Because pulsed Doppler is cumbersome and often inappropriate for color flow computation, new methods such as ACM are of interest. METHODS: In this study, 13 to 25 weeks after ASDs were surgically created in eight sheep, a total of 24 hemodynamic states were studied at a separate open chest experimental session. Electromagnetic (EM) flow probes and meters were used to provide reference flow volumes as the pulmonary and aortic flow volumes (Qp and Qs) and shunt flow volumes (Qp minus Qs). Epicardial echocardiographic studies were performed to image the left and right ventricular outflow tract (LVOT and RVOT) forward flow signals. The ACM method digitally integrated spatial and temporal color flow velocity data to provide stroke volumes. RESULTS Left ventricular outflow tract and RVOT flow volumes obtained by the ACM method agreed well with those obtained by the EM method (r = 0.96, mean difference = 0.78 +/- 1.7 ml for LVOT and r = 0.97, mean difference = -0.35 +/- 3.6 ml for RVOT). As a result, shunt flow volumes and Qp/Qs by the ACM method agreed well with those obtained by the EM method (r = 0.96, mean difference = -1.1 +/- 3.6 ml/beat for shunt volumes and r = 0.95, mean difference = -0.11 +/- 0.22 for Qp/Qs). CONCLUSIONS: This animal study, using strictly quantified shunt flow volumes, demonstrated that the ACM method can provide Qp/Qs and shunt measurements semiautomatically and noninvasively.

Animals↗

Evaluation of descending aortic flow volumes and effective orifice area through aortic coarctation by spatiotemporal integration of color Doppler data: An in vitro study.

Flow volumes in an in vitro model of the aorta with 3 different degrees of stiffness (stiff, moderately stiff, and compliant) proximal to a coarctation were calculated by using a digital color Doppler echocardiography flow calculation method that semiautomatically integrates spatial and temporal color flow velocity data. These flow volumes were compared with those obtained by the conventional pulsed Doppler method with reference to ultrasonic flowmeter. Flow volumes determined by the automated method agreed well with those obtained by ultrasonic flowmeter, even in this compliant aorta model with vessel size changing with pulsation, whereas the pulsed Doppler method overestimated the reference data, especially for more compliant descending aortic segments. The combination of flow data with continuous wave Doppler allows definition of effective orifice area for coarctation.

Aorta↗

Flow convergence flow rates from 3-dimensional reconstruction of color Doppler flow maps for computing transvalvular regurgitant flows without geometric assumptions: An in vitro quantitative flow study.

OBJECTIVE: This study was designed to develop and test a 3-dimensional method for direct measurement of flow convergence (FC) region surface area and for quantitating regurgitant flows with an in vitro flow system. BACKGROUND: Quantitative methods for characterizing regurgitant flow events such as flow convergence with 2-dimensional color flow Doppler imaging systems have yielded variable results and may not be accurate enough to characterize those more complex spatial events. METHOD: Four differently shaped regurgitant orifices were studied: 3 flat orifices (circular, rectangular, triangular) and a nonflat one mimicking mitral valve prolapse (all 4 orifice areas = 0.24 cm(2)) in a pulsatile flow model at 8 to 9 different regurgitant flow rates (10 to 50 mL/beat). An ultrasonic flow probe and meter were connected to the flow model to provide reference flow data. Video composite data from the color Doppler flow images of the FC were reconstructed after computer-controlled 180 degrees rotational acquisition was performed. FC surface area (S cm(2)) was calculated directly without any geometric assumptions by measuring parallel sliced flow convergence arc lengths through the FC volume and multiplying each by the slice thickness (2.5 to 3.2 mm) over 5 to 8 slices and then adding them together. Peak regurgitant flow rate (milliliters per second) was calculated as the product of 3-dimensional determined S (cm(2)) multiplied by the aliasing velocity (centimeters per second) used for color Doppler imaging. RESULTS: For all of the 4 shaped orifices, there was an excellent relationship between actual peak flow rates and 3-dimensional FC-calculated flow rates with the direct measurement of the surface area of FC (r = 0.99, mean difference = -7.2 to -0.81 mL/s, % difference = -5% to 0%), whereas a hemielliptic method implemented with 3 axial measurements of the flow convergence zone from 2-dimensional planes underestimated actual flow rate by mean difference = -39.8 to -18.2 mL/s, % difference = -32% to -17% for any given orifice. CONCLUSIONS: Three-dimensional reconstruction of flow based on 2-dimensional color Doppler may add quantitative spatial information, especially for complex flow events. Direct measurement of 3-dimensional flow convergence surface areas may improve accuracy for estimation of the severity of valvular regurgitation.

Blood Flow Velocity↗

Quantitative assessment of chronic aortic regurgitation with 3-dimensional echocardiographic reconstruction: comparison with electromagnetic flowmeter measurements.

Two-dimensional echocardiography and color Doppler are useful in the qualitative assessment of aortic regurgitation. However, color Doppler planar methods are not accurate in quantifying regurgitant flow, in part because of the complex geometry of aortic regurgitant flow events. Three-dimensional echocardiographic reconstruction is a new technique that provides dynamic 3-dimensional images of intracardiac color flow jets. We sought to determine whether the measurement of aortic regurgitant jet volume by 3-dimensional echocardiography correlated with the true regurgitant volume, measured by electromagnetic flowmeter in vivo, to accurately reflect the severity of aortic regurgitation. We performed volume-rendered 3-dimensional echocardiography in 6 sheep with surgically induced chronic eccentric aortic regurgitation. We obtained a total of 22 aortic regurgitation states by altering loading conditions. Instantaneous regurgitant flow rates were obtained by aortic and pulmonary electromagnetic flowmeters. The maximum aortic regurgitant jet volume by 3-dimensional echocardiography and the maximum jet area by 2-dimensional echocardiography were measured and compared with electromagnetic flowmeter data. By electromagnetic flowmeter, aortic regurgitant flow rate varied from 0.14 to 3.1 L/min (mean 1. 25 +/- 0.78); aortic regurgitant stroke volume varied from 1 to 34 mL/beat (mean 12 +/- 8), and regurgitant fraction varied from 3% to 42% (mean 25% +/- 12%). The maximum jet volume by 3-dimensional echocardiography correlated very well with the aortic regurgitant stroke volume (r = 0.92; P <.0001), with the mean regurgitant flow rate (r = 0.87; P <.0001), and with the regurgitant fraction (r = 0. 87; P <.0001) derived from electromagnetic flowmeter. Both intraobserver and interobserver variability on the measurement of the jet volume by 3-dimensional echocardiography were excellent (r = 0.98; P <.0001 and r = 0.90; P <.001, respectively). The maximum jet area by 2-dimensional echocardiography did not correlate with the aortic regurgitant stroke volume (r = 0.41; P = not significant) and related poorly with the regurgitant fraction (r = 0.52; P <.05) by electromagnetic flowmeter. Dynamic 3-dimensional echocardiography can allow better determination of the geometry of the aortic regurgitant jet and may assist of quantifying the severity of aortic regurgitation.

Animals↗

Acoustically stimulated transient power scattering explains enhanced detection of the very low velocities in myocardial capillaries by power Doppler imaging: an in vitro study.

BACKGROUND: Although enhanced detection of myocardial perfusion signals by power Doppler imaging during contrast echocardiography has been noted, flow velocities in the coronary microvasculature should generally be below the threshold for Doppler motion detection. It has been suggested that in this situation nonlinear scattering related to acoustically stimulated microsphere oscillation or destruction may be responsible for the detected Doppler shift. METHODS AND RESULTS: This study examined the behavior of MRX 115 (ImaRx Pharmaceuticals) microbubbles during harmonic and nonharmonic power Doppler imaging at varying power outputs (mechanical indexes 0. 3, 0.5, 0.7, and 0.9) in a perfusion tube model under zero-flow conditions. Boluses of MRX 115 0.5-mL suspension were introduced into the model, and flow was halted during each imaging period. Once power Doppler imaging was implemented, a signal was detected as unique sparkling color pixels corresponding to individual bubble destruction events, even in the absence of contrast movement. This phenomenon continued until all contrast bubbles disappeared from the region subjected to power Doppler imaging, usually within 35 to 40 seconds. Off-line videointensity measurements showed that initial power Doppler signal intensity and maximum signal decay rates increased parallel to increasing power output and were substantially greater for nonharmonic than for harmonic imaging modes. CONCLUSION: This relationship between signal intensity and decay rate and acoustic power output suggests that transient scattering related to bubble destruction is responsible for generation of the power Doppler signal in the absence of flow. This would explain the enhanced detection of the very low velocity flows in the myocardial capillaries by power Doppler contrast imaging.

Blood Flow Velocity↗

[Imported trichinellosis with severe myositis--report of a case].

A 38-year-old Japanese male who had traveled in China from September 13 to October 5, 1997, developed fever and severe conjunctivitis from October 20. After he was hospitalized in Kyoto City Hospital for persistent high fever on October 29, he developed muscular weakness and dysphagia which continued for two weeks. An electromyogram showed a myogenic pattern, and laboratory findings showed significant elevation of serum enzyme levels of muscle origin: CPK, 3,095 IU/l; aldorase, 195 IU/l; myoglobin, 7,570 ng/ml, and myoglobinuria, 94,700 ng/ml. The WBC was 10,800/microliter with 45% eosinophils. Muscular biopsy showed degeneration of muscle fibers with infiltration of macrophages and lymphocytes. On further inquiry, it was revealed that the patient had eaten smoked bear meat in China on September 30, three weeks prior to the onset of symptoms. A dot-ELISA serologic test for parasites was positive for Trichinella. Further, a coiled 1.2 mm long Trichinella larve was recovered from approximately 100 mg of frozen biopsied muscle by an enzyme digestion method. Mebendazole was given to the patient at a dosage of 200 mg/day for seven days. CPK levels were normalized within 3 days of the beginning of the treatment, and he was discharged without any symptoms. Physicians must be aware of trichinellosis and should include it in their differential diagnosis when examining patients with myositis and eosinophilia of unknown origin.

Adult↗