Experimental MR imaging-guided interstitial cryotherapy of the brain.

BACKGROUND AND PURPOSE: Hyperthermal ablation techniques such as laser or RF ablation require dedicated heat-sensitive MR imaging sequences for monitoring MR imaging--guided interventions. Because cryotherapy does not have these limitations, the purpose of this study was to evaluate the feasibility of MR imaging--guided percutaneous cryotherapy of the brain. METHODS: An experimental cryoprobe with an outer diameter of 2.7 mm was inserted into the right frontal lobe of 11 healthy pigs under MR imaging control. Freezing procedures were monitored by using an interventional 1.5-T magnet and a gradient-echo sequence with radial k-space trajectories, a fast T2-weighted single-shot spin-echo sequence, and a T1-weighted single-shot gradient-echo sequence. In three animals, the procedure was also monitored by using dynamic CT. A freeze-thaw cycle with a duration of 3 minutes was repeated three times per animal. Follow-up MR images were obtained 3, 7, and 14 days after cryotherapy by using conventional MR sequences. Six animals were killed 7 days after intervention, and five animals were killed 14 days after intervention. The brains were sectioned, and the histologic findings of the lesions were compared with the MR imaging appearance. RESULTS: No artifacts due to the probe were observed on the MR images or CT scans. The ice formation (mean diameter, 12.5 mm) was very well delineated as a signal-free sphere. MR monitoring of the freezing procedure yielded a significantly higher ice:tissue contrast than did CT. The size of the ice ball as imaged by MR imaging and CT during the intervention correlated well with the MR imaging appearance of the lesions at the 14-day follow-up examination and with the histologic findings. Histologically, coagulation necrosis and gliosis were found, surrounded by a transition zone of edema and a disrupted blood-brain barrier, corresponding to a contrast-enhancing rim around the lesions on follow-up MR images. CONCLUSION: MR imaging-guided cryotherapy of the brain is possible and allows a precise prediction of the resulting necrosis. MR imaging of the freezing process does not require heat-sensitive sequences and is superior to CT for monitoring of cryoablation.

Animals↗

[Radial k-scanning for real-time MR imaging of central and peripheral pulmonary vasculature].

PURPOSE: To depict the central and peripheral pulmonary vessel anatomy with real-time radial MR scanning without respiratory control. METHODS: Three healthy volunteers and one patient with pulmonary embolism proven by spiral CT angiography were studied with a 1.5 T MR imaging system. First, a breath-hold, contrast-enhanced MR angiography was performed for comparison of accuracy. Gradient echo images (TR 16 ms, TE 4 ms, flip angle 18 degrees) were obtained applying a combination of radial scanning and the sliding window reconstruction technique. A dedicated back-projector allowed data reconstruction in real-time with a frame rate of 20 images per second. Scanning was performed during free breathing. RESULTS: The described technique depicted the central and peripheral portions of the normal pulmonary anatomy with comparable image quality as the 3D contrast-enhanced angiography. Visualization of the pulmonary emboli as demonstrated by spiral CT was possible. CONCLUSION: Real-time radial scanning allows promising image acquisition of the pulmonary vasculature without respiratory control. Further technical improvements and clinical trials are required to evaluate its role in the diagnosis of vascular pathologies.

Adult↗

Motion compensated projection reconstruction.

Over recent years, MRI has shown the capability for real-time applications. Although the acquisition times of fast MRI methods have been reduced significantly, patient motion during a magnetic resonance imaging (MRI) examination still causes artifacts in the image. In this paper, the effects of motion in MRI using a radial acquisition scheme are examined. It is shown that motion can be estimated without the use of additional measurement, based on the acquired projections only. A new reconstruction technique is introduced that integrates a motion compensation algorithm into the MR-reconstruction process, resulting in a significant reduction of blurring artifacts in the reconstructed images. The proposed method is applied to different kinds of motion such as kinetic joint studies.

Algorithms↗

[MR defecography at 1.5 Tesla with radial real-time imaging and reduced image field].

PURPOSE: To evaluate a new technique for MR defecography with real-time imaging using radial k-space profiles. MATERIALS AND METHODS: A catheter-mounted condom was inserted into the rectum of 16 patients and filled in situ by a mixture of Nestargel and Gadolinium. After multiplanar imaging of the pelvis by high resolution T2-weighted turbo-spin echo sequences, defecation was imaged by a gradient echo sequence with radial k-space filling using a reduced field of view (rFOV) in real-time. The documentation was performed on an S-VHS recorder. RESULTS: At a constant background signal, radial k-space filling yields a real-time impression. An interactive software allowed the operator to modify the slice thickness, slice plane, flip angle and slice angulation during scanning, resulting in an optimum imaging quality of the defecation. CONCLUSIONS: This new imaging technique allows real-time MR defecography in a high-field scanner and provides all anatomical und functional information of the defecation.

Adult↗

Fast 1H spectroscopic imaging using a multi-element head-coil array.

Fast proton magnetic resonance spectroscopic imaging (MRSI) using a multi-element head-coil array is examined with respect to three aspects: the coil design, the use of an appropriate signal combination method, and the design of the MRSI pulse sequence itself. An eight-element head-coil array has been developed to increase the signal-to-noise ratio (SNR) of MRSI in the human brain. The flexible wraparound design optimally fits different head sizes and thus provides high sensitivity. The signal combination of the individual coil elements is based on the approach proposed by Roemer et al. (Magn. Reson. Med. 16, 192 (1990)). An additional short prescan is performed to provide a good estimate of the complex coil sensitivity profiles, which are used in the signal combination procedure to correct the spectroscopic imaging data for the spatially varying intensity. The use of coil arrays in MRSI has some effect on the requirements for both water and lipid suppression. These techniques and a MRSI pulse sequence that provides a high spectroscopic resolution are described and discussed. Experimental results at 1.5 T show that metabolite maps of N-acetylaspartate (NAA), choline (Cho), phosphocreatine (PCr)/creatine (Cr) can be obtained within a 5-min acquisition time.

Aspartic Acid↗

Motion-adapted gating based on k-space weighting for reduction of respiratory motion artifacts.

A new modified type of gating is presented that shows the ability to reduce the total scan time with almost conserved image quality compared with conventional gating. This new motion-adapted gating approach is based on a k-space-dependent gating threshold function. MR data acquired are only accepted if the motion-induced displacements measured from a reference position are below the chosen gating threshold function. During the MR measurement the scanner analyses respiratory motion decides in real-time which data in k-space could be measured according to the gating threshold function and performs data acquisition. In the present paper the approach will be described and discussed. Simulations based on in vivo data and initial in vivo experiments are presented to compare different variants of the new approach mutually and to the conventional technique. The analysis given is focused on spin warp type sequences, which are the best candidates for this approach.

Abdomen↗

Curved slice imaging.

Curved slice imaging based on multidimensional RF pulses is introduced and discussed. This new approach makes it possible to image curved anatomical structures by using MRI. The 2D RF or 3D RF pulses used can be tailored to excite or refocus transverse magnetization of a previously defined arbitrarily curved slice profile in a 3D space. These RF pulses can be integrated into all standard MRI sequences to perform slice selection. The final curved slice image is obtained as a projection of the curved slice magnetization onto a selected imaging plane. The problem of ambiguities arising due to this projection process is addressed. Phantom and in vivo experiments were performed to illustrate the advantages and limitations of this approach.

Brain↗