Search PubMed⌕ Search

Biomedical subjects

T S Johnson

Publications and source records attributed to T S Johnson.

75 records · Page 5Linked to original sources

Reliability of three length measurement techniques in term infants.

PURPOSE: To describe and compare the intra- and interexaminer reliability of three length measurement techniques and to determine if the three measurement techniques yield significantly different measurements. METHOD: Two experienced, mother-baby nurses each obtained length measurements using the supine, paper barrier, and Auto-length measurement techniques twice each from 48 healthy term infants. The nurses were blind to their own and to each other's measurements. The order of the nurses and the order of the measurement techniques were randomized. RESULTS: For intraexaminer reliability, RN-1 had smaller mean absolute differences for the Auto-length measurements. RN-2 had similar mean absolute differences for all three measurement techniques. The percentage of differences < or = 1 cm were smallest for the supine measurements for RN-1 and not remarkably different between the measurement techniques for RN-2. For interexaminer reliability, the mean absolute differences between the pairs of measurements were smallest for the Auto-length measurements for Set-1 and for the paper-barrier measurements for Set-2. The percentage of differences < or = 1 cm between the pairs of measurements for Set-1 were not remarkably different and were lowest for the supine measurements for Set-2. The mean measurements obtained by the supine, paper-barrier, and the Auto-length measurements were respectively: 50.88, 50.33, and 49.67 cm. The differences between the means were statistically significant (X2 = 56.56, p = .0000). CONCLUSIONS: The differences between length measurements by individual examiners and pairs of examiners are relatively large. Clinicians should be aware of the magnitude of error in length measurements and should interpret length measurements with caution. These findings also demonstrate that all clinicians in any setting should use the same technique to obtain length measurements.

Anthropometry↗

Reliability of head circumference measurements in preterm infants.

PURPOSE: To describe and compare the intra- and interexaminer reliability of head circumference measurements obtained with paper and cloth tape measures. METHOD: Two experienced neonatal nurses each obtained head circumference measurements using both paper and cloth tape measures twice each, from 49 clinically stable, preterm infants. The nurses were blind to their own and to each other's measurements. The order in which the measurements were obtained was randomized. The differences within and between examiners for cloth and paper tape measurements were described using mean absolute differences, standard deviation of net differences, technical error of measurement, minimal and maximal differences, percentage of differences 0.25 and 0.5 cm, and percentage of error. RESULTS: Wilcoxon matched-pairs, signed-ranks tests demonstrated significantly greater intraexaminer reliability for measurements obtained with the paper tape for both of the nurses. Wilcoxon matched-pairs, signed-ranks tests also demonstrated significantly greater interexaminer reliability for measurements obtained with the paper tape for both the first and second measurement sets. CONCLUSIONS: Intra- and interexaminer differences were consistently smaller when the examiners used paper tape measures.

Cephalometry↗