Search PubMed⌕ Search

Biomedical subjects

T S Ing

Publications and source records attributed to T S Ing.

At least 55 records · Page 3Linked to original sources

Acute renal failure after streptokinase therapy in a patient with acute myocardial infarction.

Cholesterol embolization syndrome (CES) usually occurs after the performance of invasive vascular procedures. With the frequent use of thrombolytic agents, an increasing number of reported cases of renal CES attributed to the use of such agents has appeared. In most of these reports, the diagnosis was made on the basis of either clinical presentations or skin biopsy. We report a patient who developed acute renal failure as a result of histologically proven renal CES occurring after the use of streptokinase for the treatment of an acute myocardial infarction. The acute renal failure later became chronic; consequently, the patient was placed on continuous ambulatory peritoneal dialysis. Although the prognosis of renal CES has been described to be poor, our patient regained enough of his renal function 8 months after the onset of renal failure to make it possible to discontinue the dialytic therapy.

Acute Kidney Injury↗

Collection of a representative fraction of total spent hemodialysate.

We describe a method of obtaining a small representative fraction of spent dialysate by placing a side tube in the dialysate drainage tube. The side tube, capped with a small-gauge needle, is used to collect the specimen. Fractions obtained in this fashion are found to have a composition similar to that of the remaining spent dialysate.

Hemodialysis Solutions↗

Effect of dialysate temperature on central hemodynamics and urea kinetics.

Use of cool dialysate is associated with increased intradialytic blood pressure, but the hemodynamic mechanism is unknown. Whether changes in dialysate temperature affect muscle blood flow, which may the alter the degree of urea compartmentalization, also is unknown. We measured hemodynamics and blood and dialysate-side urea kinetic indices in nine hemodialysis patients during two cool (35.0 degrees C) versus two warm (37.5 degrees C) dialysate treatments. The % change in mean arterial pressure was different when using the cool (+6.5 +/- 9.7 mm Hg) versus the warm (-13.4 +/- 3.6) dialysate (P < 0.01), despite comparable amounts of fluid removal. Percent changes in cardiac output were similar with the two dialysates, and thus the blood pressure effect was due primarily to changes in total peripheral resistance (% delta TPR, cool +26 +/- 13.6, warm +8.6 +/- 14.5; P < 0.02). During cool dialysate use tympanic membrane temperature changed by -0.51 +/- 0.23 degree C, whereas body temperature increased by 0.52 +/- 0.14 degree C during use of warm dialysate. Measured urea recovery normalized to the predialysis urea nitrogen concentration was similar with the two treatments: cool 31.3 +/- 0.039 liter-1; warm 29.7 +/- 0.021; P = NS. In a second study, post-dialysis urea rebound values from 15 seconds to 30 minutes, expressed as the percent of the post-dialysis SUN, were similar after the two treatments: cool 11.79 +/- 1.4; warm 12.21 +/- 2.27, P = NS.(ABSTRACT TRUNCATED AT 250 WORDS)

Blood Pressure↗

Metastatic soft tissue calcification in chronic renal failure detected by radionuclide imaging.

Metastatic calcification has been reported in several disease entities, including chronic renal failure. Various imaging modalities have been shown to be useful in the detection of metastatic soft tissue calcification. Radionuclide imaging may detect metastatic soft tissue calcification more readily than routine diagnostic modalities and be a valuable noninvasive method to establish an early diagnosis in high-risk patients. The authors report a patient with extensive soft tissue metastatic calcification who had a myriad of clinical symptoms. The extensive calcification was detected with a radionuclide imaging.

Calcinosis↗

Neutrophil intracellular pH after exposure of neutrophils to a euhydric, lactate-based peritoneal dialysis solution and its euhydric, bicarbonate-based counterpart.

The effects of euhydric, lactate-based peritoneal dialysis solutions and those of their euhydric, bicarbonate-based counterparts, on neutrophil intracellular pH are comparable. This similarity in effects on intracellular acidity may have bearings on the influences of these solutions on cellular functions in general.

Adolescent↗

Hypomagnesemia in continuous ambulatory peritoneal dialysis patients dialyzed with a low-magnesium peritoneal dialysis solution.

OBJECTIVE: Previous studies have shown a decrease in serum magnesium (Mg) concentration when continuous ambulatory peritoneal dialysis (CAPD) patients previously maintained on a 1.0-1.2 mEq/L Mg peritoneal dialysis solution (PDS) were dialyzed with a 0.5 mEq/L Mg PDS. However, the prevalence of hypomagnesemia in CAPD patients dialyzed with low-Mg PDS is unknown. DESIGN: A retrospective study to determine the prevalence of hypomagnesemia and the factors associated with its occurrence in CAPD patients dialyzed using a 0.5 mEq/L Mg PDS. SETTING: A CAPD unit in a large Veterans Affairs Hospital. PATIENTS: All our CAPD patients (33) enrolled over a 52-month period. RESULTS: All patients had serum magnesium levels higher than 1.25 mEq/L prior to use of low-Mg PDS. Hypomagnesemia (serum Mg < 1.25 mEq/L) developed in 21/33 patients (64%) when a 0.5 mEq/L Mg PDS was employed. Hypomagnesemia developed a mean of 8.2 months after beginning treatments. The duration of dialysis and the number of episodes of peritonitis did not differ between patients with and those without hypomagnesemia. Serum albumin levels were significantly lower in patients with hypomagnesemia (2.5 +/- 0.12 g/dL vs 3.2 +/- 0.12, p < 0.01). Magnesium supplements were given to 13 patients; following this therapy, serum magnesium values became normal. CONCLUSIONS: CAPD patients dialyzed with a 0.5 mEq/L Mg PDS may develop a considerable fall in serum magnesium level and may require magnesium supplements in order to restore normal serum values.

Dialysis Solutions↗

Employing L-lactic acid powder in the preparation of a dry "acid concentrate" for use in a bicarbonate-based dialysis solution-generating system: experience in hemodialysis patients.

By replacing the liquid acetic acid present in the "acid concentrate" of a bicarbonate-based dialysis solution-generating system with an equimolar amount of solid L-lactic acid and by using the dry forms of the remaining constituents, we were able to create a dry "acid concentrate" just prior to use, and successfully employed this "acid concentrate" to produce a bicarbonate-based solution to hemodialyze patients.

Bicarbonates↗

Adverse effects of dialyzers manifesting during the dialysis session.

The intradialytic symptoms that can be linked to components of the extracorporeal circuit of greatest clinical importance are the Type A (anaphylactoid) reactions. Most of these are IgE-mediated reactions due to ethylene oxide and are preventable by adequate degassing of the dialyzer by the manufacturer and by adequate rinsing of the dialyzer just prior to use. AN69-associated reactions are a second group, and are probably mediated by membrane-induced bradykinin generation coupled with ACE-inhibitor induced prolongation of bradykinin half-life. Type A reactions occur in a reuse setting, alos, and these may be related to some as yet poorly understood interaction between bleach, reuse sterilants, and certain dialyzer membranes, again, with ACE inhibitors playing an amplifier role. There is no compelling evidence linking membrane-induced complement activation to type A dialyzer reactions. However, there is a large body of evidence in animal models that exposure to complement fragment-releasing membranes can increase the pulmonary artery pressure and increase thromboxane formation. Thus, at least in principle, a case can be made for using unsubstituted cellulose membranes with caution in patients with a history of atopy or eosinophilia, particularly if acetate dialysate is to be used. Such a caution, however, must be viewed as conjectural in the absence of definitive evidence. Type B dialyzer reactions (mild back and chest pain 20-60 min into the dialysis session) is a phenomenon that is in the process of vanishing. The reason why is unclear. These reactions may have been due to some sort of dialyzer contaminant, or they may have been due to complement fragment release and required the use of acetate dialysate as a cofactor. In any event, recent well designed studies fail to find any differences in symptoms between unsubstituted cellulose and synthetic membranes. Membrane-induced complement fragment release also may play a minor role in dialysis hypoxemia, but evidence is conflicting in this area. Again, the use of acetate dialysate appears to be an important cofactor. Post-dialysis events which may be conceivably linked to the delayed effects of complement fragment releasing membranes need to be evaluated in controlled studies. Studies suggesting increased post-dialysis catabolism with use of unsubstituted cellulose membranes need to be confirmed in dialysis patients, and symptomatic correlates should be sought and evaluated.

Anaphylaxis↗