Risk stratification for restenosis after coronary angioplasty by means of exercise echocardiography.

To assess the prognostic contribution of exercise two-dimensional echocardiography in patients undergoing elective coronary angioplasty, 60 patients (44 males, 16 females, mean age 61 years) were enrolled in this study. The series included 31 patients with single-vessel disease, 23 with two vessel, and 5 with three vessel disease. After successful PTCA, they underwent stress echocardiographic testing either by treadmill (n = 23) or bicycle ergometry (n = 37), performed with digital continuous loop technique. A wall motion index (WMI) was calculated at rest and at peak stress. According to WMI values, the study population was divided into three groups: patients with normal WMI both at rest and stress (Group 1); patients with abnormal baseline WMI without change at stress (Group 2) and abnormal WMI diagnostic of stress-induced ischemia (Group 3). During the follow-up period, minimum of 1 year, 21 patients complaining of recurrent angina or chest discomfort, had repeat angiography: in 13 of these, typical restenosis of a previously dilated artery was found; 2 patients had progression of atherosclerotic plaque and in 6 the angiogram showed a good result of PTCA. Thirteen patients with restenosis or progressive disease underwent repeat PTCA. In this group, only 2 belonged to Group 1, 4 to Group 2, and 7 to Group 3. Thus, a linear correlation between the WMI value post-angioplasty and the clinical course could be documented (p = 0.001). Stress echocardiography was superior to stress ECG in both negative predictive value (88 and 77% respectively) and positive predictive value (73 versus 50%).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Spinal cord perfusion pressure in dogs after control of proximal aortic hypertension during thoracic aortic cross-clamping with esmolol or sodium nitroprusside.

BACKGROUND: Spinal cord perfusion pressure may be reduced when sodium nitroprusside is used to control proximal aortic hypertension during thoracic aortic clamping. The effect of esmolol infusion on spinal cord perfusion pressure during thoracic aortic clamping is unknown. This study compares spinal cord perfusion pressure following control of proximal hypertension with either sodium nitroprusside or esmolol during thoracic aortic clamping. METHODS: The thoracic aorta was cross-clamped for 30 min in 18 dogs anesthetized with halothane. A control group (n = 6) received no treatment of proximal hypertension during cross-clamping. In two other groups, proximal arterial pressure was controlled (100 mmHg) by infusion of either sodium nitroprusside (n = 6) or esmolol (n = 6). Brachial and femoral arterial pressures, spinal cord perfusion pressure, pulmonary artery occlusion, central venous pressures, and cardiac output were monitored. Neurologic assessment was performed 24 h following surgery. RESULTS: Femoral arterial pressure was lower with nitroprusside (14 +/- 3 mmHg) compared to esmolol (24 +/- 4 mmHg) after 15 min of aortic cross-clamping. Cerebrospinal fluid pressure increased during aortic cross-clamping in the sodium nitroprusside group (from 7 +/- 5 to 16 +/- 6 mmHg) but not in esmolol or control groups. Spinal cord perfusion pressure was lower with nitroprusside at 15 min of aortic cross-clamping (2 +/- 4 mmHg) compared to control (15 +/- 7 mmHg) and esmolol groups (17 +/- 11 mmHg). Esmolol infusion reduced cardiac output and increased ventricular filling pressures compared to control and nitroprusside groups. CONCLUSIONS: Esmolol was associated with greater spinal cord perfusion pressure, but adverse hemodynamic effects, when compared with nitroprusside during thoracic aortic cross-clamping. When only surviving dogs (4 control, 5 esmolol, 6 nitroprusside) are considered, the incidence of neurologic deficit was greater in nitroprusside-treated dogs than in either control or esmolol-treated dogs. No difference in outcome was present when all dogs are considered.

Adrenergic beta-Antagonists↗

Fibrin cuff lysis in chronic venous ulcers treated with a hydrocolloid dressing.

BACKGROUND: Pericapillary fibrin cuffs (PFC) are a recognized part of the pathology of venous stasis ulcers. A hydrocolloid dressing capable of lysing wound surface fibrin was tested in venous ulcers for its capacity to lyse pericapillary fibrin below the wound surface. METHODS: Tissue biopsies from the rims of 19 venous ulcers were evaluated for thickness of shallow and deep dermal PFCs before and after treatment with DuoDERM covered by Unna's boot and a compression bandage (DD+UB; n = 9) versus the same treatment without the hydrocolloid dressing (UB; n = 10). Frozen sections of all biopsies were stained with an immunofluorescent antibody to fibrin for rating of PFC thickness. Separate sections were stained with hematoxylin and eosin to assess capillary frequency, histopathology, and inflammation. All ratings and pathology assessments were performed blinded to treatment conditions. RESULTS: Both deep and shallow PFCs were reduced in 89% of ulcers treated with DD+UB versus 40% of ulcers treated with UB (alpha < 0.04). No other significant differences in inflammation, histopathology, or capillary frequency were observed. CONCLUSIONS: Treatment with DD+UB reduced PCFs in twice the number of ulcers than UB alone in 1 week. This is the first scientific documentation that a topical wound dressing could reduce the pathophysiology associated with venous ulcers, beyond the known beneficial effect of graduated compression. Not all hydrocolloid dressing are fibrinolytic, so this effect may not generalize to other dressings.

Bandages↗

Symptoms, adverse effects, and complications associated with dobutamine stress echocardiography. Experience in 1118 patients.

BACKGROUND: The use of dobutamine stress echocardiography for the evaluation of coronary artery disease is rapidly expanding. New applications of the technique are being investigated in a wide variety of patients including those with advanced coronary artery disease. Despite its widespread use, the safety of dobutamine stress echocardiography has not been sufficiently documented. METHODS AND RESULTS: A consecutive series of 1118 patients undergoing dobutamine stress echocardiography for evaluation of known or suspected coronary artery disease form the basis of this report. Dobutamine stress testing was performed for evaluation of chest pain, risk assessment before noncardiac surgery, after recent myocardial infarction, or as a part of ongoing research protocols. Over the study period, the maximal dose of dobutamine used was increased from 30 to 50 micrograms/kg per minute, and atropine was used in 420 (37%) patients. There were no occurrences of death, myocardial infarction, or episodes of sustained ventricular tachycardia as a result of dobutamine stress testing. The major reasons for test termination were achievement of target heart rate in 583 patients (52.1%), maximum dose in 255 (22.8%), and angina pectoris in 142 (13%). The test was terminated in 36 (3%) patients because of noncardiac side effects including nausea, anxiety, headache, tremor, and urgency. Angina pectoris occurred in 216 (19.3%) patients. Sublingual nitroglycerin, a short-acting beta-blocker, or both types of medication were administered in 80 of these patients for relief of angina pectoris. None required intravenous nitroglycerin. A total of 736 (65%) patients had stable sinus rhythm throughout the test. The most common arrhythmias were frequent premature ventricular complexes (six or more per minute) in 172 patients (15%), and frequent premature atrial complexes in 86 (8%). There were 40 patients with nonsustained ventricular tachycardia. None had symptoms associated with the tachycardia, and only one received specific pharmacological treatment to prevent recurrence of the arrhythmia after the test was terminated. The patients who were evaluated after recent myocardial infarction and those who received atropine did not have a higher frequency of ventricular tachycardia compared with those without recent infarction and those not receiving atropine. CONCLUSIONS: Dobutamine stress echocardiography was safely performed using supplemental atropine and an aggressive dosing protocol. Noncardiac side effects were usually minor. Arrhythmias were well tolerated and rarely required treatment. In this study, serious complications from myocardial ischemia did not occur. Symptomatic ischemia was effectively treated with test termination, sublingual nitroglycerin, or short-acting beta-blockers.

Angina Pectoris↗

Low-dose dobutamine echocardiography detects reversible dysfunction after thrombolytic therapy of acute myocardial infarction.

BACKGROUND: Dysfunction after thrombolytic therapy of acute myocardial infarction (MI) may be reversible. Early after myocardial infarction, both reversible and irreversible injury may be manifested by regional wall motion abnormalities. Improved wall thickening during dobutamine infusion (dobutamine-responsive wall motion) may accurately identify reversibly injured segments. METHODS AND RESULTS: To determine whether dobutamine-responsive wall motion accurately detects reversible postischemic dysfunction irrespective of infarct location, multistage (baseline, 4 and 12 micrograms.kg-1.min-1, and peak) dobutamine echocardiography (DE) was performed within 7 days of thrombolytic therapy. Resting echocardiography was repeated > or = 4 weeks after MI, and reversible dysfunction was defined as improved wall motion. The accuracy of dobutamine-responsive wall motion was compared with that of signs of early reperfusion, non-Q-wave MI, and peak creatine kinase (CK). Sixty-three patients underwent DE without complications. Follow-up echocardiograms were done in 51 (81%) of these patients, and wall motion improved in 22 (41%). Dobutamine-responsive wall motion during all stages of DE was very specific for reversible dysfunction (90% to 93%) but sensitive (86%) only when hemodynamics were not altered (low dose, 4 micrograms.kg-1.min-1). Non-Q-wave MI and a low peak CK (< 1000 IU/mL) were also specific (89% to 93%) but less sensitive (64% [P = .16] and 55% [P < .05], respectively). Signs of early reperfusion did not identify postischemic dysfunction. Low-dose dobutamine-responsive wall motion and non-Q-wave MI independently identified reversible dysfunction, but only dobutamine-responsive wall motion was sensitive in all infarct locations. Non-Q-wave MI was sensitive only in anterior infarction. CONCLUSIONS: Multistage dobutamine echocardiography can be performed safely early after thrombolytic therapy. Low-dose dobutamine-responsive wall motion accurately detected reversible dysfunction in all infarct locations. Dobutamine-responsive wall motion and non-Q-wave infarction may be very useful for accurately identifying reversible dysfunction early after thrombolytic therapy for acute MI.

Adult↗

Maternal grief after sudden infant death syndrome.

Six months after the death of their infants of Sudden Infant Death Syndrome (SIDS), the subjective impression of mothers anonymously rating their initial and present grief was that there had been a reduction in all symptoms (p < .001). However, an increase in the relative ranking of some cognitive symptoms over somatic ones, the association of certain lifestyles and situational variables with higher levels of grief, and the implication for future symptoms of family decisions made during bereavement underscore the importance of continuing active support for these families. In relative ranking, guilt rose from 10th to 5th most prominent symptom, particularly among the 34% of mothers whose infants manifested clinical symptoms (p < .05). Single mothers had higher grief scores both initially (p < .05) and at 6 months (p < .002), were almost three times more likely to become pregnant within 6 months of the death but only one-third as likely to attend a support group, and were also more likely to move after the death (44% vs 25%). Mothers whose infants had been discovered by another caregiver reached out more to a crisis intervention service of a support program available to SIDS families (p < .05). Mothers without surviving children had grief levels comparable with those with children but were less likely to rate their pediatrician's support as satisfactory, increasing the probability that they would change physicians with subsequent children, thereby losing continuity of care and support.

Adult↗

The effects of Medicare and Medicaid reimbursement on the financial viability of clinics and physician practices in medically under-served areas of Wisconsin.

A survey of 21 physicians and clinic managers located in Health Professional Shortage Areas (HPSAs) and other under-served areas in Wisconsin found that to combat increasing costs, Medicare and Medicaid discounts, charity care demands and physician recruitment difficulty, several practices rely on outside sources of funding to remain financially viable. Also, the financial viability of physician practices in under-served areas of Wisconsin is threatened more by the reimbursement rates of Medicaid and Medicare than by the provision of charity care. Though few are limiting the number of Medicare and uninsured patients they will treat, many practices have begun implementing cost-containment measures, including more strict collection policies. There are also indications of restricted access for Medicaid patients at some sites.

Ambulatory Care Facilities↗

An overview of a study on the financial viability of clinics and physician practices in medically under-served areas of Wisconsin.

A survey of 21 physicians and clinic managers located in Health Professional Shortage Areas (HPSAs) and other under-served areas in Wisconsin found that to combat increasing costs, Medicare and Medicaid discounts, charity care demands and physician recruitment difficulty, several practices rely on outside sources of funding to remain financially viable. Also, the financial viability of physician practices in under-served areas of Wisconsin is threatened more by the reimbursement rates of Medicaid and Medicare than by the provision of charity care. Though few are limiting the number of Medicare and uninsured patients they will treat, many have begun implementing cost-containment measures, including more strict collection policies. There are also indications of restricted access for Medicaid patients at some sites.

Ambulatory Care Facilities↗

Exercise echocardiography.

Exercise echocardiography is a versatile, noninvasive diagnostic test that involves the recording and interpretation of 2-dimensional echocardiograms prior to, during, and after exercise. By analyzing and comparing wall motion at each stage, a prediction about the presence or absence of coronary artery disease can be made. The development of a wall motion abnormality is both sensitive and specific for the presence of a significant coronary stenosis. Changes in regional systolic function during exercise enable the clinician to distinguish between infarction and ischemia. Thus, the test yields information on the presence, extent, severity, and location of coronary artery disease. Echocardiography can be adapted to almost any form of stress, although treadmill or bicycle exercise are most commonly employed. An advantage of bicycle stress echocardiography is the opportunity to image during exercise, rather than relying on postexercise recording. This contributes to enhanced sensitivity, although false-positive results may increase due to the difficulties of analyzing wall motion during strenuous exercise. Exercise echocardiography increases the diagnostic accuracy of stress testing in a manner similar to radionuclide perfusion imaging. It is particularly useful in the setting of an ambiguous stress electrocardiography (ECG) or when a false-negative or false-positive result is suspected. It has been successfully applied to patients following revascularization and yields useful prognostic data in a variety of clinical situations. Exercise echocardiography is being increasingly utilized as a safe and accurate test in patients with known or suspected coronary artery disease.

Coronary Disease↗

Dobutamine stress echocardiography: correlation with coronary lesion severity as determined by quantitative angiography.

This study was performed 1) to determine the ability of dobutamine stress echocardiography to detect stenoses in individual coronary arteries by utilizing a new model of coronary artery distribution; 2) to evaluate its ability to detect coronary artery stenosis with a minimal lumen diameter less than 1 mm; and 3) to correlate the heart rate at which a positive test result occurs with the severity of coronary artery disease. Eighty-five patients were identified who underwent both dobutamine stress echocardiography and quantitative coronary angiography. During incremental infusion of dobutamine, two-dimensional echocardiograms were obtained at rest, during low and peak stress and after stress. Echocardiograms were interpreted with use of a modified 16-segment model with an anteroinferior overlap scheme. The overall sensitivity of the technique for the detection of significant coronary artery disease (diameter stenosis greater than or equal to 50%) was 95%; specificity was 82% and accuracy 92%. The sensitivity for detection of individual coronary artery lesions did not differ significantly (p greater than 0.05) in the three major coronary artery distributions (79% left anterior descending, 70% left circumflex, 77% right coronary artery). Among 35 stenoses with a minimal lumen diameter less than 1 mm, the test result was positive in 30 (86%). Test results were correctly positive for 88%, 82% and 86% of stenoses in the left anterior descending, left circumflex and right coronary artery distributions, respectively. Multivessel disease was present in 11 of 16 patients with normal wall motion at rest who developed a wall motion abnormality at a heart rate less than 125 beats/min. The incidence of multivessel disease was statistically higher in patients with positive findings on a dobutamine stress echocardiogram at a heart rate less than or equal to 125/min. In conclusion, dobutamine stress echocardiography has high sensitivity and specificity for the detection and localization of coronary artery disease. Detection of stenosis in individual coronary arteries is improved in those lesions with a minimal lumen diameter less than 1 mm. Patients with a positive test result at a heart rate less than or equal to 125 beats/min have a high likelihood of multivessel coronary artery disease.

Adult↗

Distinguishing ischemic cardiomyopathy from nonischemic dilated cardiomyopathy with coronary echocardiography.

Transthoracic echocardiographic examination of the proximal left coronary system was performed in 59 patients who had dilated cardiomyopathy to determine if this technique could distinguish between ischemic and nonischemic dilated cardiomyopathy. With use of annular array transducers (3.5 or 5 MHz) and digital image processing, echocardiographic visualization of the coronary arteries was successful in 55 (93%) of 59 patients. As assessed by coronary angiography, 32 subjects had ischemic cardiomyopathy and 27 had nonischemic cardiomyopathy. Twenty-seven (84%) of the 32 patients who had coronary artery disease and 24 (89%) of the 27 patients with nonischemic cardiomyopathy were correctly identified. The accuracy of coronary echocardiography was 86% in the entire study group and 93% when patients with inadequate studies were excluded. All subjects who had ischemic cardiomyopathy had evidence of disease by coronary echocardiography or segmental wall motion abnormalities. Multivariate analysis permitted correct classification of 93% of all subjects based on the results of the coronary echocardiogram, evaluation of segmental wall motion and a history of prior myocardial infarction. The correct diagnosis was made in 86% when the results of coronary echocardiography were excluded from analysis using all other echocardiographic and clinical variables. Transthoracic coronary echocardiography can be performed with a high degree of success in patients with dilated ventricles and the technique can reliably distinguish between ischemic and nonischemic dilated cardiomyopathy.

Cardiomyopathy, Dilated↗

Dobutamine stress echocardiography as a predictor of cardiac events associated with aortic surgery.

Two-dimensional echocardiography can detect regional wall motion abnormalities resulting from myocardial ischemia produced by dobutamine infusion. In 60 patients undergoing elective aortic surgery (27 with aneurysms, 33 with occlusive disease), we evaluated the ability of dobutamine stress echocardiography to predict perioperative cardiac events. Echo images were obtained at rest and during incremental dobutamine infusion to a peak dose of 50 micrograms/kg/min, unless another test end point was reached (angina, heart rate greater than or equal to 85% of age-predicted maximum, significant ST segment depression, or new stress-induced wall motion abnormalities). Dobutamine stress echocardiography results were stratified as follows: group I, no wall motion abnormalities; group II, resting wall motion abnormalities unchanged with stress; group III, stress-induced worsening of resting wall motion abnormalities; group IV, new-onset wall motion abnormalities with stress. Twelve cardiac events occurred within the first 30 postoperative days: three cardiac deaths (5%), six nonfatal myocardial infarctions (10%), two patients with unstable angina (3.3%), and one patient with asymptomatic elevation of creatine phosphokinase MB isoenzymes without electrocardiographic changes (1.7%). Eleven events occurred in the 38 patients with an abnormal dobutamine stress echocardiograph (groups II to IV); in contrast, only one of 22 patients with a normal dobutamine stress echocardiograph (group I) had a cardiac event. These event rates (29% vs 4.6%) differed significantly (p less than 0.025). Dobutamine stress echocardiography is a new, safe, rapid, relatively low cost, noninvasive, nonexercise cardiac stress test for risk stratification before major vascular surgery.

Aged↗

Transoesophageal pulsed wave Doppler measurement of cardiac output during major vascular surgery: comparison with the thermodilution technique.

We measured cardiac output in 12 patients undergoing elective abdominal vascular surgery at specific times during the procedure with simultaneous thermodilution and transoesophageal pulsed Doppler echocardiographic techniques. No patient had clinical evidence of valvular heart disease before surgery. Five patients had echocardiographic evidence of mitral regurgitation on colour-coded Doppler. Using Bland and Altman analysis to compare the cardiac output measurement by the two techniques, the Doppler method overestimated the cardiac output (bias = 0.86 litre min-1) compared with the thermodilution technique and there were wide limits of agreement between the two techniques (+2.4 to -4.1 litre min-1). However, in the seven patients with no evidence of mitral regurgitation, closer agreement (bias 0.14 litre min-1) and narrower limits (+1.6 to -1.3 litre min-1) were observed. We conclude that, in patients with competent mitral valves, transoesophageal echocardiograph may provide accurate determination of cardiac output.

Aorta↗

Bicycle stress echocardiography.

Bicycle stress echocardiography involves the recording and interpretation of two-dimensional echocardiographic information before, during, and after bicycle exercise. The exercise test can be performed in the supine or upright posture. While there are important physiological differences between these two positions, they appear to provide similar diagnostic information on the presence or absence of coronary artery disease. A major advantage of bicycle stress echocardiography compared to treadmill exercise is the ability to image at peak exercise, rather than relying solely on pre- and postexercise imaging. This contributes to the greater sensitivity of the test for the detection of ischemia. The recent application of digital processing techniques may also improve sensitivity by permitting side-by-side comparison of rest and stress images. In summary, bicycle stress echocardiography is a useful tool in the management of patients with known or suspected coronary artery disease. It is a versatile and accurate technique, which competes favorably with other imaging modalities and provides information on regional and global left ventricular function.

Coronary Disease↗

Catecholamine stress echocardiography.

Two-dimensional echocardiographic monitoring during catecholamine infusion has shown promise as a safe and accurate method for detection of coronary artery disease. The clinical application of catecholamine stress echocardiography has been facilitated by the development of digital image processing techniques. The sensitivity of this method of stress testing has been improved by drug infusion protocols that are designed to maximize myocardial stress. Recent investigations have demonstrated the value of dobutamine stress echocardiography for detection of multivessel disease following myocardial infarction and for assessment of cardiac risk before noncardiac surgery. Evaluation of changes in wall motion and thickening that occur during low dose dobutamine infusion may enable detection of viable myocardium after thrombolytic treatment of acute myocardial infarction. Compared to alternative noninvasive diagnostic methods, catecholamine stress echocardiography permits continuous acquisition of high-quality information on regional and global systolic function. This and other advantages have prompted the search for broader applications of this technique.

Animals↗

Agitation and postdexamethasone cortisol levels in Alzheimer's disease.

The clinical correlates of hypothalamic-pituitary-adrenal (HPA) functioning were examined in 29 patients with probable Alzheimer's disease. The 8:00 a.m. postdexamethasone cortisol levels of these patients were highly correlated with higher agitation scores but not with the degree of depressed mood or memory impairment. The possible neural basis for the association between hypercortisolism and behavioral disturbance in Alzheimer's disease warrants further exploration and replication.