Search PubMed⌕ Search

Biomedical subjects

T R McCauley

Publications and source records attributed to T R McCauley.

At least 37 records · Page 2Linked to original sources

Changes in magnetic resonance transverse relaxation times of two muscles following standardized exercise.

Magnetic resonance (MR) imaging studies of exercising leg muscles were performed to compare the changes in MR transverse relaxation times (T2) that result from exercise of the anterior tibialis (AT) and extensor digitorum/hallicus longus (E) in the anterior compartment of the lower leg with those T2 changes in the medial and lateral gastrocnemius (G) in the posterior compartment. Spin-echo MR images were obtained at 1.5 Tesla before and during the first 14 min of recovery from dynamic exercise. In order to normalize the exercise, workloads for each subject were set at 25% of the measured maximum voluntary contraction (MVC) of the anterior and posterior compartments. In separate exercise sessions, a nonmagnetic, pneumatic exercise apparatus was employed for either dorsiflexion or plantarflexion against a fixed constant resistance for two different exercise durations (1 min 45 s or 5 min). Transaxial MR images (TR = 1000 ms, TE = 30, 60, 90, 120 ms, 128 x 256 matrix, 1.5 cm slice) were used to calculate T2 values. Although subjects performed approximately 7-fold more work (P < or = 0.001, dorsiflexion vs plantarflexion) during plantarflexion than during dorsiflexion at both exercise duration's, the exercise induced T2, while being greater than those at rest (P < or = 0.001), were not significantly different in the different compartments. We conclude that, when exercised at the same workload (25% of MVC), these two muscles produce T2 changes that are not significantly different from each other.

Adult↗

Peripheral vascular occlusive disease: accuracy and reliability of time-of-flight MR angiography.

PURPOSE: To determine the accuracy and reliability of magnetic resonance (MR) angiography for identification of stenosis and patent distal vessels in patients with peripheral vascular disease. MATERIALS AND METHODS: Two-dimensional time-of-flight MR angiography and conventional arteriography were performed in 22 patients. Four blinded radiologists independently graded multiple anatomic segments. RESULTS: MR angiography allowed detection of more patent vessel segments than did conventional arteriography. For detection of significant stenosis (> 75%), MR angiography had 43%-67% sensitivity and 74%-89% specificity. Discrepancies in detection of significant stenosis occurred in 39 segments for the most accurate reviewer; 27 of these discrepancies were avoidable. CONCLUSION: For detection of significant stenosis, MR angiography has low to moderate sensitivity and specificity; however, observer variability appears to be a major contributing factor to the discrepancies. Greater reviewer experience or techniques for improving reliability may improve the accuracy of MR angiography in peripheral vascular disease.

Adult↗

MR diagnosis of tears of anterior cruciate ligament of the knee: importance of ancillary findings.

OBJECTIVE: Detection of tears of the anterior cruciate ligament with MR is usually based on the appearance of the ligament. However, other MR findings may be useful to establish the diagnosis. We assessed the utility of these ancillary MR findings for detecting tears and for differentiating partial from complete tears of the anterior cruciate ligament. MATERIALS AND METHODS: MR images of 68 patients who had arthroscopic correlation were retrospectively reviewed by two radiologists who did not know the arthroscopic findings. The reviewers noted the presence and location of bone bruises (nonlinear low signal in the bone marrow on T1-weighted images), assessed posterior displacement of the posterior horn of the lateral meniscus, and measured the posterior cruciate ligament angle. At arthroscopy, 39 patients had tears of the anterior cruciate ligament (24 complete, 15 partial) and 29 had intact anterior cruciate ligaments. RESULTS: The presence of bone bruising in the posterolateral tibial plateau had sensitivities of 50% and 46%, with corresponding specificities of 97% and 97% for the two reviewers. Posterior displacement of the posterior horn of the lateral meniscus had a sensitivity of 56% for both reviewers, with 100% and 97% specificities. An angle of the posterior cruciate ligament less than 105 degrees had sensitivities of 72% and 74%, with corresponding specificities of 79% and 86%. The prevalence of these findings was similar in patients with partial tears and those with complete tears. CONCLUSION: Ancillary MR imaging findings may be helpful for diagnosing tears of the anterior cruciate ligament when diagnosis based on the MR appearance of the ligament is equivocal. Ancillary findings cannot be used to differentiate patients with partial tears from those with complete tears. The presence of bone bruising in the posterior aspect of the tibial plateau and posterior displacement of the posterior horn of the lateral meniscus are highly specific for a torn anterior cruciate ligament; therefore, the presence of either of these findings should be considered strong evidence of a tear of the anterior cruciate ligament.

Adult↗

SLAP lesions of the glenoid labrum diagnosed with MR imaging.

Tears of the superior portion of the glenoid labrum in patients without shoulder instability have recently been described. These tears, which include the "anchor" of the biceps tendon to the labrum, have been labeled "SLAP lesions" (superior labrum anterior to posterior). This study was performed to determine the magnetic resonance (MR) findings in patients with SLAP lesions. Retrospective review of the shoulder arthroscopy reports on patients who underwent MR imaging using a 1.5-T unit and subsequent arthroscopy by a single surgeon identified six patients with SLAP lesions (average age 36 years, range 17-65 years). MR images demonstrated atypical morphology indicative of tear in the superior portion of the labrum in four of the six patients, but only one tear had been identified preoperatively. Radiologists interpreting MR images of the shoulder should be aware of the MR findings of SLAP lesions as these tears can be a significant cause of patient disability and are difficult to diagnose clinically.

Adolescent↗

Zonal anatomy of the cervix: correlation of MR imaging and histologic examination of hysterectomy specimens.

High-resolution magnetic resonance (MR) images of nine hysterectomy specimens were correlated with light microscopy, computer-aided image analysis, and immunohistochemical examination to investigate the histologic counterparts of the zonal anatomy of the cervix. A central stripe of high signal intensity, a surrounding middle layer of low signal intensity, and an outer layer of intermediate signal intensity were found in all specimens. Histologic correlation indicated that the central stripe most likely represents the secretions in the canal, the cervical mucosa, and the plicae palmatae; the other two layers represent fibromuscular stroma. The percentage of nuclear area in the inner zone of the fibromuscular stroma is 2.5 times greater than in the outer zone, which may account for the lower signal intensity of the inner zone. No difference in distribution of collagen, laminin, and fibronectin (common components of the extracellular matrix) was found between the two zones of the cervical fibromuscular stroma.

Adult↗

Pelvic phased array coil: image quality assessment for spin-echo MR imaging.

The NMR phased array coil (PA) provides improved signal-to-noise ratio (SNR) over that available with the body coil. We evaluated image quality obtained with a pelvic PA compared to that obtained with the body coil for spin-echo imaging. Thirty-three women undergoing clinical pelvic MRI were imaged with the body coil followed by imaging with the PA with the same field-of-view (FOV) in 11 patients, and with a small FOV in 23 patients. Image quality was assessed independently by two radiologists. In individual cases there was significant improvement in image quality with the PA, however the expected marked improvement in image quality was not consistently found. Two factors which may limit image quality are increased motion artifact and nonuniformity of signal with distance from the coils. Significant improvements in image quality may occur with improved techniques to decrease motion artifact.

Adult↗

Effect of prone versus supine patient positioning on pelvic magnetic resonance image quality.

RATIONALE AND OBJECTIVES: Magnetic resonance imaging (MRI) of the pelvis in the prone position has been proposed as a means of reducing motion-related image blurring. The authors performed a randomized controlled trial to determine if patient positioning affects image quality. METHODS: All women undergoing pelvic MRI during a 7-month period, who could lie both prone and supine, were randomized to the supine or prone position. The quality of axial T2-weighted spin-echo images was rated by two radiologists using a 1-to-4 scale (1 = marked blurring to 4 = sharp definition of pelvic structures). RESULTS: Of 78 eligible women, 61 were randomized. Two patients could not complete the examination. The mean image quality rating of 2.8 for the 32 patients imaged prone was not significantly different from the mean rating of 2.9 for the 27 patients imaged supine (P = .5, Mann-Whitney U test). CONCLUSION: Patient positioning did not significantly affect pelvic MRI quality. The choice of patient position should be based on other considerations, such as patient comfort or ease of patient positioning.

Adult↗

Magnetic resonance imaging in the evaluation of the portal venous system.

Magnetic resonance (MR) imaging is used in assessing the portal venous system through qualitative and quantitative methods. Magnetic resonance angiography can be performed using time-of-flight or phase-contrast techniques. Time-of-flight techniques (which use gradient echo images to display bright blood or spin echo images to display black blood) are relatively standardized and commercially available. These techniques are used to display liver morphology, portal vein patency, portal venous collaterals, and surgically created portosystemic shunts. Magnetic resonance is equivalent to angiography in the detection of varices, according to a preliminary study. Time-of-flight flow imaging using gradient echo techniques (in which a thrombus appears as absence of bright signal in the portal vein) and spin-echo techniques (where thrombus appears as a bright signal) can become combined to increase specificity for diagnosis of portal vein thrombosis. Phase-contrast techniques provide flow information based on phase shifts induced by flow through magnetic gradients. Phase-contrast angiography is less widely available than time-of-flight angiography. However, phase-contrast methods allow imaging of very slow flow that is not possible using time-of-flight methods. Quantitation of flow is possible, both with time-of-flight techniques using bolus tracking and with phase-contrast techniques using quantitative measurement of phase shifts. Calculations of flow velocity correlate well with Doppler ultrasound estimations, MR flow quantitation does not, at present, rival ultrasound in terms of cost or availability. However, MR is not limited by obesity or overlying bowel gas which can prevent adequate ultrasound evaluation.(ABSTRACT TRUNCATED AT 250 WORDS)

Humans↗

Normal and abnormal glenoid labrum: assessment with multiplanar gradient-echo MR imaging.

A retrospective study of magnetic resonance (MR) imaging of the glenoid labrum performed with multiplanar gradient-echo (MPGR) sequences was done to ascertain the different appearances of the normal labrum and the findings in patients with tears. MPGR images were obtained with a 1.5-T magnet in 37 shoulders of 16 healthy subjects and 19 patients with subsequent surgical evaluation. Increased intralabral signal intensity was seen in 12 of 26 normal shoulders (46%), and atypical morphology was seen in six shoulders (23%). Atypical morphology was present in eight of nine patients with labral tears. Deformity (n = 2 [22%]) and clefts (n = 2 [22%]) were seen in patients with tears. Deformity (n = 3 [12%]) and clefts (n = 1 [4%]) were occasionally seen in healthy subjects. Absence of the labrum and separation of the labrum from the glenoid cavity was present only in patients with tears; therefore, the labrum should be presumed torn in the presence of these findings. Increased intralabral signal intensity on MPGR images did not help predict labral integrity; morphologic findings were more predictive of labral tear.

Adolescent↗

Fast spin-echo MR imaging of the female pelvis. Part I. Use of a whole-volume coil.

In this prospective study, axial and sagittal magnetic resonance (MR) images were obtained with T2-weighted conventional spin-echo (CSE) and fast spin-echo (FSE) sequences in 34 consecutive female patients who underwent clinical pelvic MR examination at 1.5 T. The MR images from each patient were compared side by side, blindly and independently, by two radiologists experienced in MR imaging who used a standardized score sheet for anatomic and pathologic findings. The FSE sequences were rated superior significantly more often than the CSE sequences in most categories of findings (P less than .05), including overall image quality and reduction of motion artifact. The examination time for the FSE sequences was 1 minute 46 seconds versus an examination time of 9 minutes 14 seconds for the CSE sequences. (Both CSE and FSE sequences provided 18 sections.) It is concluded that the FSE sequence provides T2-weighted anatomic and pathologic information superior to that provided by the CSE sequence and requires substantially less imaging time.

Adolescent↗

Multicoil high-resolution fast spin-echo MR imaging of the female pelvis.

A fast spin-echo pulse sequence was combined with multiple surface coils used simultaneously in the form of a "multicoil" in magnetic resonance imaging studies of the female pelvis. This combination allowed maximal resolution with maintenance of the signal-to-noise ratio (S/N) at an acceptable level, and the S/N with the multicoil system was substantially better than that achieved with a body coil. Excellent image quality and demonstration of anatomic detail were afforded by use of this technique.

Adolescent↗

Chondromalacia patellae: diagnosis with MR imaging.

Most previous studies of MR imaging for detection of chondromalacia have used T1-weighted images. We correlated findings on axial MR images of the knee with arthroscopic findings to determine MR findings of chondromalacia patellae on T2-weighted and proton density-weighted images. The study population included 52 patients who had MR examination of the knee with a 1.5-T unit and subsequent arthroscopy, which documented chondromalacia patellae in 29 patients and normal cartilage in 23. The patellar cartilage was assessed retrospectively for MR signal and contour characteristics. MR diagnosis based on the criteria of focal signal or focal contour abnormality on either the T2-weighted or proton density-weighted images yielded the highest correlation with the arthroscopic diagnosis of chondromalacia. When these criteria were used, patients with chondromalacia were detected with 86% sensitivity, 74% specificity, and 81% accuracy. MR diagnosis based on T2-weighted images alone was more sensitive and accurate than was diagnosis based on proton density-weighted images alone. In conclusion, most patients with chondromalacia patellae have focal signal or focal contour defects in the patellar cartilage on T2-weighted MR images. These findings are absent in most patients with arthroscopically normal cartilage.

Adolescent↗

Submucosal uterine leiomyomas: diagnosis of prolapse into the cervix and vagina based on MR imaging.

OBJECTIVE: We describe the MR appearance, signs and symptoms, and pathologic findings in five patients with submucosal leiomyomas that prolapsed into the cervical or vaginal canal. SUBJECTS AND METHODS: During the past 3 years, five women aged 33-53 years (mean, 43 years) were identified prospectively at MR imaging as having prolapsing uterine leiomyomas. The diagnosis was confirmed by surgical pathology. MR imaging was performed on a 1.5-T unit, using both T1- and T2-weighted spin-echo or fast spin-echo sequences. The images were analyzed for signal intensity, presence of a stalk, and caudal extent of the prolapsed leiomyoma. RESULTS: These leiomyomas, the presence of prolapse, and the caudal extent of prolapse were detected prospectively on MR images in all five cases. Prospective localization of the stalk in two cases aided subsequent hysteroscopic resection. MR imaging correctly indicated the presence of hemorrhage in one, degeneration in a second, and the absence of these complications in two others. In the fifth case, a hemorrhagic focus in the distal tip of the leiomyoma was not detected on MR images obtained 3 days before surgery. CONCLUSION: MR imaging is useful for the diagnosis and characterization of uterine leiomyomas that have prolapsed into the cervical or vaginal canal.

Adult↗

Junctional zone of the uterus: correlation of MR imaging and histologic examination of hysterectomy specimens.

High-resolution magnetic resonance (MR) images of 12 hysterectomy specimens were correlated with results of light microscopy, image analysis, and immunohistochemical studies to investigate the histologic counterpart of the low-signal-intensity band, or junctional zone (JZ), that surrounds the bright central uterine stripe. All specimens were imaged with a 1.5-T superconducting magnet within 21/2 hours (on average) after hysterectomy. Comparison of histologic findings with measurements obtained at MR imaging indicates that the JZ represents the innermost layer of the myometrium. A threefold increase in percentage of nuclear area was found in the JZ in comparison with the outer myometrium, reflecting an increase in both size and number of nuclei. No difference in distribution of common components of the extracellular space (collagen, laminin, and fibronectin) was found between the two layers.

Adult↗

Validation of volume flow measurements with cine phase-contrast MR imaging for peripheral arterial waveforms.

A flow phantom was used to study MR volume flow measurements for monophasic and triphasic waveforms over the flow range expected in peripheral arteries at rest and with exercise (2-24 mL/sec, n = 50). The improvement in accuracy with phase-correction image processing to eliminate errors caused by eddy currents was measured. Volume flow estimates with Doppler sonography were also measured. MR volume flow measurements correlated with volume collection with r = .996 and mean error = 4.6%. Phase-correction processing decreased mean error from 12.6% to 4.6% (P < .001, paired t-test). Doppler sonography had a higher mean error of 10.3% (P < .001, unpaired t-test). Cine phase-contrast MR imaging provides accurate estimates of volume blood flow for waveforms and flow ranges expected in peripheral arteries.

Adult↗

The reliability of radiologists' quality assessment of MR pelvic scans.

The purpose of this study was to test the reliability of radiologists' subjective assessment of the quality of MR scans of the pelvis. A four-grade ordinal subjective scale, based on the degree of artifact and contrast between pelvic organs, was developed in a pilot study by two MR radiologists. Forty pelvic scans were graded "blindly" in random order by the same two "practiced" MR radiologists, and an objective measurement of scan artifact was obtained for each scan. Twenty-eight pelvic scans were also graded by two "unpracticed" radiologists not involved in the development of the scale. For the practiced radiologists, the interobserver percentage agreement was 80% (weighted kappa of 0.78) and the intraobserver percentage agreement was 75% (weighted kappa of 0.73). For the unpracticed radiologists the percentage agreement was 61% and the weighted kappa was 0.55. The correlation between the subjective and objective measurement was only 0.27. In conclusion, the objective measurement of scan artifact showed poor correlation with the radiologists' subjective assessment of scan quality. The subjective assessment demonstrated satisfactory reliability and, therefore, could be considered as an additional outcome measurement for scan quality in clinical trials or as a relevant measure of quality assurance.

Artifacts↗

Chondroblastoma: MR characteristics with pathologic correlation.

PURPOSE: The purpose of this study was to describe the MR findings of chondroblastoma with pathologic correlation. METHOD: In 22 patients with pathologically proven chondroblastoma, MR signal characteristics were correlated with pathological findings. RESULTS: On T2-weighted images, 12 (55%) lesions were hyperintense with hypointense areas in 9 lesions, whereas 10 (45%) were hypointense. Therefore, 19 of 22 (86%) lesions with pathologic correlation had hypointense areas entirely (n = 10) or partly (n = 9) on T2-weighted images. On gadolinium-enhanced images, 13 (59%) lesions showed lobular enhancement and 9 (41%) showed marginal and septal enhancement. Low signal intensity on T2-weighted MR images was most strongly associated with an abundance of immature chondroid matrix, hypercellularity of the chondroblasts, calcifications, and hemosiderin on histology. CONCLUSION: Chondroblastoma was found to show hypointense portions on T2-weighted images. Signal intensity on T1- and T2-weighted MR images in chondroblastoma was dependent on the amounts of histopathological components.

Adolescent↗

Mechanisms of signal loss in magnetic resonance imaging of stenoses.

Some of the factors affecting the signal losses that occur in magnetic resonance images at a stenosis or other region of complex flow have been evaluated. The important determinants of dephasing within a volume element are the net gradient moments, which can be kept small even at long echo times. For compact gradient wave forms, the echo time by itself is unimportant and does not affect signal losses. Reducing the fraction of echo sampled is an alternate method to velocity compensation for reducing gradient moment dephasing that keeps higher moments small. The effects of reducing the fraction of echo sampled on the signal losses in flow distal to a stenosis have been measured experimentally. Another source of signal loss at a stenosis is the variation of the mean phase within a volume element that occurs for flow that varies from one phase encoded view to another. Changes in flow behavior between acquisitions lead to signal displacement in the image. These view to view changes have also been quantified.

Biophysical Phenomena↗