Megavoltage CT on a tomotherapy system.

A megavoltage computed tomography (MVCT) system was developed on the University of Wisconsin tomotherapy benchtop. This system can operate either axially or helically, and collect transmission data without any bounds on delivered dose. Scan times as low as 12 s per slice are possible, and scans were run with linac output rates of 100 MU min(-1), although the system can be tuned to deliver arbitrarily low dose rates. Images were reconstructed with clinically reasonable doses ranging from 8 to 12 cGy. These images delineate contrasts below 2% and resolutions of 3.0 mm. Thus, the MVCT image quality of this system should be sufficient for verifying the patient's position and anatomy prior to radiotherapy. Additionally, synthetic data were used to test the potential for improved MVCT contrast using maximum-likelihood (ML) reconstruction. Specifically, the maximum-likelihood expectation-maximization (ML-EM) algorithm and a transmission ML algorithm were compared with filtered backprojection (FBP). It was found that for expected clinical MVCT doses enough imaging photons are used such that little benefit is conferred by the improved noise model of ML algorithms. For significantly lower doses, some quantitative improvement is achieved through ML reconstruction. Nonetheless, the image quality at those lower doses is not satisfactory for radiotherapy verification.

Algorithms↗

Registration using tomographic projection files.

An algorithm has been developed and experimentally verified for tomographic registration--a patient positioning method using internal anatomy and standard external fiducial marks. This algorithm improves patient set-up and verification to an accuracy sufficient for tomotherapy. By implementation of this technique, the time-consuming reconstruction process is avoided. Instead, offsets in the x, y and z directions are determined directly from sinogram data by an algorithm that utilizes cross-correlations and Fourier transforms. To verify the efficiency and stability of the algorithm, data were collected on the University of Wisconsin's dedicated tomotherapy research workbench. The experiment indicates offset statistical errors of less than +/-0.8 mm for offsets up to 30 mm. With standard clinical techniques, initial patient offsets are expected to be less than 5 mm, so the 30 mm limitation is of no consequence. The angular resolution for the direction of patient translation is within the +/-2 degrees needed for tomotherapy.

Algorithms↗

Delivery verification in sequential and helical tomotherapy.

Conformal and conformal avoidance radiation therapy are new therapeutic techniques that are generally characterized by high dose gradients. The success of this kind of treatment relies on quality assurance procedures in order to verify the delivery of the treatment. A delivery verification technique should consider quality assurance procedures for patient positioning and radiation delivery verification. A methodology for radiation delivery verification was developed and tested with our tomotherapy workbench. The procedure was investigated for two cases. The first treatment using a torus-shaped target was optimized for 72 beam directions and sequentially delivered as a single slice to a 33 cm diameter cylinder of homogeneous solid water. For the second treatment, a random pattern of energy fluence was helically delivered for two slices to a 9.0 cm diameter phantom containing inhomogeneities. The presented process provides the energy fluence (or a related quantity) delivered through the multileaf collimator (MLC) using the signal measured at the exit detector during the treatment delivery. As this information is created for every pulse of the accelerator, the energy fluence and state for each MLC leaf were verified on a pulse-by-pulse basis. The pulse-by-pulse results were averaged to obtain projection-by-projection information to allow for a comparison with the planned delivery. The errors between the planned and delivered energy fluences were concentrated between +/-2.0%, with none beyond +/-3.5%. In addition to accurately achieving radiation delivery verification, the process is fast, which could translate to radiation delivery verification in real time. This technique can also be extended to reconstruct the dose actually deposited in the patient or phantom (dose reconstruction).

Acrylates↗

Image/patient registration from (partial) projection data by the Fourier phase matching method.

A technique for 2D or 3D image/patient registration, PFPM (projection based Fourier phase matching method), is proposed. This technique provides image/patient registration directly from sequential tomographic projection data. The method can also deal with image files by generating 2D Radon transforms slice by slice. The registration in projection space is done by calculating a Fourier invariant (FI) descriptor for each one-dimensional projection datum, and then registering the FI descriptor by the Fourier phase matching (FPM) method. The algorithm has been tested on both synthetic and experimental data. When dealing with translated, rotated and uniformly scaled 2D image registration, the performance of the PFPM method is comparable to that of the IFPM (image based Fourier phase matching) method in robustness, efficiency, insensitivity to the offset between images, and registration time. The advantages of the former are that subpixel resolution is feasible, and it is more insensitive to image noise due to the averaging effect of the projection acquisition. Furthermore, the PFPM method offers the ability to generalize to 3D image/patient registration and to register partial projection data. By applying patient registration directly from tomographic projection data, image reconstruction is not needed in the therapy set-up verification, thus reducing computational time and artefacts. In addition, real time registration is feasible. Registration from partial projection data meets the geometry and dose requirements in many application cases and makes dynamic set-up verification possible in tomotherapy.

Algorithms↗

Development of a unique phantom to assess the geometric accuracy of magnetic resonance imaging for stereotactic localization.

OBJECTIVE: To test the spatial accuracy of coordinates generated from magnetic resonance imaging (MRI) scans, using the Brown-Roberts-Wells head frame and localizer system (Radionics, Inc., Burlington, MA). METHODS: An anthropomorphic head phantom, consisting of a two-dimensional lattice of acrylic spheres (4-mm diameter) spaced 10 mm apart and embedded in a brain tissue-mimicking gelatin-agar gel, was constructed. The intersphere distances for the target lattice positions in MRI and computed tomographic scan sets were compared. The data sets were fused, and differences in fiducial marker and intraphantom target positions were measured. RESULTS: Intersphere distances were identical for the MRI and computed tomographic scan sets (10 +/- 0.1 mm). Differences in fiducial marker positions [maximal lateral difference, 0.97 mm; mean absolute lateral difference, 0.69 +/- 0.22 mm; maximal anteroposterior (AP) difference, 1.99 mm; mean absolute AP difference, 1.29 +/- 0.67 mm] were correlated with differences in intraphantom target positions (maximal lateral difference, 0.83 mm; mean absolute lateral difference, 0.28 +/- 0.24 mm; maximal AP difference, -1.97 mm; mean absolute AP difference, 1.63 +/- 25 mm; maximal vertical difference, -0.73 mm; mean absolute vertical difference, 0.34 +/- 0.21 mm). This suggested that improper fiducial rod identification and the subsequent transformation to stereotactic coordinate space were the greatest sources of spatial uncertainty. CONCLUSION: With computed tomographic data as the standard, these differences resulted in maximal and minimal composite uncertainties of 2.06 and 1.17 mm, respectively. The measured uncertainties exceed recommended standards for radiosurgery but allow the possible use of MRI-based stereotactic treatment planning for certain intracranial lesions, if the errors are corrected using appropriate software. Clinicians must recognize that error magnitudes vary for different systems, and they should perform systematic, scheduled, institutional error analyses as part of their ongoing quality assurance processes. This phantom provides one tool for measuring such variances.

Brain Mapping↗

Characterization of the output for helical delivery of intensity modulated slit beams.

The UW tomotherapy workbench utilizes a convolution/superposition based dose calculation and optimization program. It specifies the energy fluence that must be delivered from each leaf for each phantom projection angle. This requires that the spectrum of the radiation emitted from the one-dimensional MLC (multileaf collimator) attached to the linear accelerator be determined. The steps involved in that process are described. The spectrum along the central axis of the slit beam was determined, as well as the softening with off-axis position. Moreover, the magnitude of the energy-fluence output had to be quantified on a per MU (monitor unit) basis. This was done for a single leaf along the central axis of the beam. Factors, which modify that energy-fluence output, were investigated. The output increases with off-axis position due to the horns of the beam. The output for a leaf of interest will also increase if additional leaves are open due to the absence of the tongue-and-groove effect and penumbra blurring. The energy-fluence increase per leaf increase by 4.9% if an adjacent leaf is open. No other factors related to the state of additional leaves were found to significantly increase the energy-fluence output for an individual leaf.

Algorithms↗

Multileaf collimator interleaf transmission.

Multileaf collimators (MLCs) have advanced past their original design purpose as a replacement for field shaping cerrobend blocks. Typically, MLCs incorporate an interlocking tongue-and-groove design between adjacent leaves to minimize leakage between leaves. They are beginning to be used to provide intensity modulation for conformal three-dimensional radiation therapy. It is possible that a critical target volume may receive an underdose due to the region of overlap if adjacent leaves are allowed to alternate between the open and closed positions, as they might if intensity modulation is employed. This work demonstrates the magnitude of that effect for a commercially available one-dimensional temporally modulated MLC. The magnitude of the transmission between leaves as a function of leaf separation was also studied, as well as the transmission as a function of leaf rotation away from the source. The results of this work were used for the design of a tomotherapy MLC. The radiation leakage considerations for a tomotherapy MLC are discussed.

Computer Simulation↗

Monte Carlo investigation of electron beam output factors versus size of square cutout.

A major task in commissioning an electron accelerator is to measure relative output factors versus cutout size (i.e., cutout factors) for various electron beam energies and applicator sizes. We use the BEAM Monte Carlo code [Med Phys. 22, 503-524 (1995)] to stimulate clinical electron beams and to calculate the relative output factors for square cutouts. Calculations are performed for a Siemens MD2 linear accelerator with beam energies, 6, 9, 11, and 13 MeV. The calculated cutout factors for square cutouts in 10 X 10 cm2, 15 X 15 cm2, and 20 X 20 cm2 applicators at SSDs of 100 and 115 cm agree with the measurements made using a silicon diode within about 1% except for the smallest cutouts at SSD= 115 cm where they agree within 0.015. The details of each component of the dose, such as the dose from particles scattered off the jaws and the applicator, the dose from contaminant photons, the dose from direct electrons, etc., are also analyzed. The calculations show that inphantom side-scatter equilibrium is a major factor for the contribution from the direct component which usually dominates the output of a beam. It takes about 6 h of CPU time on a Pentium Pro 200 MHz computer to simulate an accelerator and additional 2 h to calculate the relative output factor for each cutout with a statistical uncertainty of 1%.

Monte Carlo Method↗

A comparison of Monte Carlo and analytic first scatter dose spread arrays.

We compare first scattered point dose spread arrays generated by Monte Carlo and an analytic method. The analytic method models energy deposition using Klein-Nishina cross sections for Compton scatter and approximations for electron transport. Assumptions in the analytic method are shown to be valid within a region of the point dose spread kernel in which meaningful comparisons can be made. Differences between the models are less than 10% for the forward scatter directions for radii greater than the electron range associated with the first scattered Compton photon. Differences in the backscatter region are discussed and indicate that the analytic model is useful for identifying large errors that might be present in numerically generated first scatter point dose spread arrays. The analytic method is simple and useful for validating first scatter kernels.

Monte Carlo Method↗

A simple model for examining issues in radiotherapy optimization.

Convolution/superposition software has been used to produce a library of photon pencil beam dose matrices. This library of pencil beams is designed to serve as a tool for both education and investigation in the field of radiotherapy optimization. The elegance of this pencil beam model stems from its cylindrical symmetry. Because of the symmetry, the dose distribution for a pencil beam from any arbitrary angle can be determined through a simple rotation of a pre-computed dose matrix. Rapid dose calculations can thus be performed while maintaining the accuracy of a convolution/superposition based dose computation. The pencil beam data sets have been made publicly available. It is hoped that the data sets will facilitate a comparison of a variety of optimization and delivery approaches. This paper will present a number of studies designed to demonstrate the usefulness of the pencil beam data sets. These studies include an examination of the extent to which a treatment plan can be improved through either an increase in the number of beam angles and/or a decrease in the collimator size. A few insights into the significance of heterogeneity corrections for treatment planning for intensity modulated radiotherapy will also be presented.

Computer Simulation↗

A proposal for a standard electronic anthropomorphic phantom for radiotherapy.

To create a database of human male and female computed tomography (CT) slices, the National Library of Medicine organized the "Visible Human Project." Since the male and female data sets provided are approximately 269 MB and 915 MB, respectively, both the size and complexity have been reduced. While making the slices accessible to those with limited computing resources, the production of these reduced data sets also presents a unique opportunity to establish a standard human CT slice library for research in radiation therapy. A brief history of the original data sets is included, as well as details of the reduction process, applications to radiotherapy, and information on accessing these reduced image files.

Adult↗

Application of constrained optimization to radiotherapy planning.

Essential for the calculation of photon fluence distributions for intensity modulated radiotherapy (IMRT) is the use of a suitable objective function. The objective function should reflect the clinical aims of tumor control and low side effect probability. Individual radiobiological parameters for patient organs are not yet available with sufficient accuracy. Some of the major drawbacks of some current optimization methods include an inability to converge to a solution for arbitrary input parameters, and/or a need for intensive user input in order to guide the optimization. In this work, a constrained optimization method was implemented and tested. It is closely related to the demanded clinical aims, avoiding the drawbacks mentioned above. In a prototype treatment planning system for IMRT, tumor control was guaranteed by setting a lower boundary for target dose. The aim of low complication is fulfilled by minimizing the dose to organs at risk. If only one type of tissue is involved, there is no absolute need for radiobiological parameters. For different organs, threshold dose, relative seriality of the organs or an upper dose limit could be set. All parameters, however, were optional, and could be omitted. Dose-volume constraints were not used, avoiding the possibility of local minima in the objective function. The approach was benchmarked through the simulation of both a head and neck and a lung case. A cylinder phantom with precalculated dose distributions of individual pencil beams was used. The dose to regions at risk could be significantly reduced using at least seven ports of beam incidence. Increasing the number of ports beyond seven produced only minor further gain. The relative seriality of organs was modeled through the use of an added exponent to the dose. This approach however increased calculation time significantly. The alternative of setting an upper limit is much faster and allows direct control of the maximum dose. Constrained optimization guarantees high tumor control probability, it is computationally more efficient than adding penalty terms to the objective function, and the input parameters are dose limits known in clinical practice.

Algorithms↗

Radiobiological studies using synchrotron-produced ultrasoft X-rays.

Ultrasoft X-rays have been extensively used to explore radiobiological mechanisms surrounding cell killing. These studies for the most part have been linked to a small number of X-ray energies. Recently, this field of study has been broadened by the availability of synchrotron-produced ultrasoft X-rays which can be produced at any desired energy. We have taken advantage of the University of Wisconsin Synchrotron to reexamine two fundamental radiobiological questions: Dose RBE vary with different ultrasoft X-ray energies? Dose the fraction of the nuclear volume exposed to equal total X-ray energy modify cell cytotoxicity? The first study focuses on the survival of Chinese hamster V79 and mouse C3H10T1/2 cells irradiated with synchrotron-produced 273 eV and 860 eV ultrasoft X-rays. These two energies, which are available by multilayer monochromatization of the synchrotron output spectrum, exhibit equal attenuation within living cells. Such an isoattenuating energy pair allows the direct examination of how biological effectiveness varies with the energy of the ultrasoft X-rays. In comparing survival results, we find similar biological effectiveness of these two energies for both the C3H10T1/2 and the V79 cells. These results are no consistent with previous findings of increasing RBE with decreasing ultrasoft X-ray energies. In addition, after correcting for mean nuclear based on measurements of cell thickness obtained with confocal microscopy, we find no significant differences in survival between the two ultrasoft X-ray energies and 250 kVp X-rays. These results suggest that RBE does not increase with decreasing energy of ultrasoft X-ray between 860 eV and 273 eV. In a second study we introduced an method which allows partial-volume irradiation of live cells using synchrotron-produced ultrasoft X-rays and micro-fabricated irradiation masks. The masks were made by X-ray lithography at the University of Wisconsin Synchrotron Radiation Center, and they consist of 1.85-micron-wide stripes of gold 1.35 microns apart plated onto thin silicon nitrate membranes. When placed adjacent to mylar on which live cells are plated, these masks allow cells to be irradiated in a striped pattern with dimensions much smaller than the cell nuclei. Using 1340 eV synchrotron-produced X-rays, we compare the survival of cells subjected to uniform irradiation and cells subjected to partial-volume irradiation. Our results show that, at equal mean dose to the nucleus (i.e. equal total energies deposited), survival is not statistically different for the two treatments over a wide range of doses. Thus, imparting equal energies to smaller intranuclear volumes does not appear to modulate cell killing.

Animals↗

A solid water pelvic and prostate phantom for imaging, volume rendering, treatment planning, and dosimetry for an RTOG multi-institutional, 3-D dose escalation study. Radiation Therapy Oncology Group.

PURPOSE: With increased interest in 3-D conformal radiation therapy and dose escalation, it is necessary to provide advanced techniques to assure quality in treatment delivery. Multi-institutional trials for these newer treatment techniques require methods of verifying the consistency of treatments between the participating institutions. For this reason, a phantom was designed to address the quality and consistency of Radiation Therapy Oncology Group (RTOG) 3-D prostate treatment protocol. METHODS AND MATERIALS: A solid water pelvic and prostate phantom for imaging, volume rendering, treatment planning, and dosimetry applications for performing comprehensive quality assurance has been designed and fabricated. Its configuration was based upon CT slices obtained from a patient study. Individual slices were machined with corresponding contours of the prostate, bladder, rectum, and the left and right femurs. Most of the phantom is made of solid water (Gammex/RMI, Middleton, WI), while the femurs are made of bone-equivalent material. The CT numbers from patient images were used to adjust the solid water composition within the organ volumes, providing image contrast from the remainder of the phantom. Cylindrical insertion grooves are machined in the phantom to allow placement of ionization chambers and thermal luminal dosimeters (TLDs) for dosimetry applications. During imaging, the cavities are filled with rods fabricated from solid water material. RESULTS: The phantom is being used to evaluate the consistency of a range of processes in radiation therapy simulation, planning, and delivery of 3-D-based treatments for prostate cancer. CONCLUSION: The ultimate study objective is to use the phantom to evaluate the accuracy and consistency of treatments delivered by institutions participating in national collaborative clinical trials involving 3-D conformal dose escalation.

Humans↗

Computed tomographic evaluation of radiation pneumonitis in a canine model.

The objective of this study was to document the utility of computed tomography (CT) and a three-dimensional (3-D) radiotherapy treatment planning system for assessing the development of acute radiation pneumonitis in a canine model. Fourteen dogs were randomly assigned to a nonirradiated control group or one of three radiation dose groups receiving a single fraction of either 12, 15, or 18 Gy delivered to two-thirds of the right hemithorax. CT and survey radiographs were performed in all dogs prior to and at defined intervals for up to 13 weeks following irradiation. All images were subjectively evaluated for development of radiation pneumonitis and CT images were quantitatively analyzed. Radiation pneumonitis was detected earlier with CT images than with radiographs. Quantitatively, functional lung volume and radiation pneumonitis lesion volume on CT images changed over time in all irradiated dogs. However, there was no statistically significant difference between the three radiation dose groups, but a marked difference between irradiated dogs and nonirradiated controls. These data suggest that CT is superior to survey radiography for the evaluation and quantification of acute radiation pneumonitis in this canine model. Quantification of acute radiation pneumonitis suggests future promise for evaluating the efficacy of modifiers to lessen the effects of irradiating normal lung tissue in this canine model.

Acute Disease↗

Maximum likelihood as a common computational framework in tomotherapy.

Tomotherapy is a dose delivery technique using helical or axial intensity modulated beams. One of the strengths of the tomotherapy concept is that it can incorporate a number of processes into a single piece of equipment. These processes include treatment optimization planning, dose reconstruction and kilovoltage/megavoltage image reconstruction. A common computational technique that could be used for all of these processes would be very appealing. The maximum likelihood estimator, originally developed for emission tomography, can serve as a useful tool in imaging and radiotherapy. We believe that this approach can play an important role in the processes of optimization planning, dose reconstruction and kilovoltage and/or megavoltage image reconstruction. These processes involve computations that require comparable physical methods. They are also based on equivalent assumptions, and they have similar mathematical solutions. As a result, the maximum likelihood approach is able to provide a common framework for all three of these computational problems. We will demonstrate how maximum likelihood methods can be applied to optimization planning, dose reconstruction and megavoltage image reconstruction in tomotherapy. Results for planning optimization, dose reconstruction and megavoltage image reconstruction will be presented. Strengths and weaknesses of the methodology are analysed. Future directions for this work are also suggested.

Algorithms↗

Registration of synthetic tomographic projection data sets using cross-correlation.

Tomographic registration, a method that makes possible accurate patient registration directly from projection data, consists of three processing steps: (i) manual coarse positioning, (ii) tomographic projection set acquisition, and (iii) computer mediated refined positioning. In the coarse positioning stage, the degree of patient alignment is comparable with that achieved with the standard radiotherapy set-up. However, the accuracy requirements are somewhat more relaxed in that meticulous alignment of the patient using external laser indicators is not necessary. Instead, tomographic projection sets are compared with planning CTs in order to achieve improved patient set-up. The projection sets are cross-correlated to obtain the best-fit translation and rotation offsets. The algorithm has been tested on synthetic data with the incorporation of varying amounts of Gaussian pseudo-random noise. These tests demonstrate the algorithm's stability and also confirm that alignment can be achieved with an accuracy of less than one projection pixel.

Algorithms↗