[Opioids in treatment of chronic noncancer pain].

Opioids have been accepted as appropriate analgesic treatment for pain associated with cancer. However, controversy exists about their use for chronic noncancer pain. Reasons for reluctance are concerned about efficacy and potential adverse effects such as respiratory depression, addiction, physical dependence or intolerance. Many physicians worry about liability and legal restrictions. Nevertheless, pain management of chronic severe pain with opioids can be the only help when alternative methods are too risky of fail to be effective. This article briefly reviews the published literature on this topic and discusses some practical guidelines for the use of opioids in the treatment of non-cancer pain.

Analgesics, Opioid

Characterization of rat lung ICAM-1.

OBJECTIVE AND DESIGN: We expressed soluble rat ICAM-1, generated a polyclonal anti-ICAM-1 antibody, and studied ICAM-1 upregulation in lung inflammatory conditions. Bacterial and baculovirus expression systems were employed. MATERIAL: 250 g adult, male Long Evans rats were used. For in vitro studies, rat pulmonary artery endothelial cells (RPAEC), rat alveolar macrophages and aortic rings were stimulated (as described below) and evaluated for ICAM-1 expression. TREATMENT: RPAEC and macrophages were stimulated with lipopolysaccharide (LPS) and recombinant murine tumour necrosis factor alpha (TNFalpha). In vivo immunoglobulin G (IgG) immune complex-induced lung injury was employed. METHODS: Enzyme-linked immunoassay (ELISA) Western and Northern blot analyses and immunohistochemical evaluations were performed. All experiments were done at least in duplicate. Data were analyzed by two-tailed Student's t-test. RESULTS: ICAM-1 expression of RPAEC was time- and dose-dependent, peaking at 6h after LPS-stimulation. LPS and TNFalpha each enhanced ICAM-1 expression on alveolar macrophages (reaching a maximum at 2 h). In IgG immune complex-induced lung injury, ICAM-1 mRNA isolated from whole lung peaked at 4 h, while lung ICAM- I protein peaked at 6 h. CONCLUSIONS: Quantitation of ICAM-1 expression in vitro and in vivo suggests that ICAM-1 plays a central role in two lung inflammatory models. Furthermore, lung ICAM-1 upregulation involves at least two cell types: vascular endothelial cells and alveolar macrophages.

Animals

Assessment of pulmonary mechanics in mechanical ventilation: effects of imprecise breath detection, phase shift and noise.

OBJECTIVE: In mechanical ventilation, the assessment of pulmonary mechanics, mainly of total compliance (Crs), total resistance (Rrs), and intrinsic positive end-expiratory pressure (PEEPint), is clinically important. By using airway pressure (Paw) and flow (V'aw), the least squares fit (LSF) method allows the continuous calculation of these parameters. The objective of this work was to study the influence of imprecise breath detection, phase shift between airway pressure and flow signals, and noise on the determination of Crs, Rrs, and PEEPint. METHODS: Paw and V'aw were mathematically simulated as well as recorded in mechanically ventilated patients. Crs, Rrs, and PEEPint were computed off-line using the LSF method. The boundaries of the breath data window and the phase relationship between Paw and V'aw signals were manipulated and noise was superimposed. RESULTS: Both simulated and patient data gave similar results. Crs and Rrs were not sensitive to imprecise breath detection. If the first portion of the breath was missed, the mean relative error on PEEPint was 20% or 53% when the exact beginning of inspiration was missed by 0.1 or 0.3 sec, respectively. Paw lag of 66 ms with respect to V'aw yielded a relative error of -15 +/- 4% (mean +/- SD) for Rrs, -5 +/- 2% for Crs, and +13 +/- 16% for PEEPint. Paw lead of 66 ms with respect to V'aw yielded a relative error of +5 +/- 4% for Rrs, +7 +/- 3% for Crs, and +14 +/- 18% for PEEPint. Noise had very little impact on the accuracy of Crs, Rrs, and PEEPint. CONCLUSIONS: We conclude that the LSF method allows the assessment of Crs, Rrs, and PEEPint even with high levels of noise in patients with normal lungs provided that Paw and V'aw signals are precisely synchronised and a reliable breath detection algorithm is used.

Adult

The effect of potato starch derived and corn starch derived hydroxyethyl starch on in vitro blood coagulation.

We have compared the effects of progressive in vitro haemodilution (30% and 60%) with potato starch derived hydroxyethyl starch and corn starch derived hydroxyethyl starch on blood coagulation in 80 patients using thrombelastography. Both solutions significantly compromised blood coagulation as evidenced by an increase in coagulation time and decrease in angle alpha, maximum amplitude and coagulation index (p < 0.05). Blood coagulation was more compromised during haemodilution with potato starch derived hydroxyethyl starch as compared with corn starch derived hydroxyethyl starch (p < 0.05). When taking the effect of haemodilution with 0.9% saline into account, haemodilution with both hydroxyethyl starch solutions also augmented clot lysis (p < 0.05), with potato starch derived hydroxyethyl starch having a greater effect than corn starch derived hydroxyethyl starch (p < 0.05). We conclude that potato starch derived hydroxyethyl starch compromises in vitro blood coagulation more than corn starch derived hydroxyethyl starch.

Adult

Substantial changes in arterial blood gases during thoracoscopic surgery can be missed by conventional intermittent laboratory blood gas analyses.

UNLABELLED: Substantial and clinically relevant changes in arterial blood gases are likely to occur during thoracoscopic surgery with one-lung ventilation (OLV). We hypothesized that they may be missed when using the conventional intermittent blood gas sampling practice. Therefore, during 30 thoracoscopic procedures with OLV, the sampling intervals between consecutive intermittent laboratory blood gas analyses (BGA) were evaluated with respect to changes of PaO2, PaCO2, and pHa ([H+]) using a continuous intraarterial blood gas monitoring system. Frequency and timing of BGA were based on the clinical judgment of 16 experienced anesthesiologists who were blinded to the continuously measured values. Extreme fluctuations of PaO2 (37-625 mm Hg), PaCO2 (27-56 mm Hg), and pHa (7.24-7.51) were observed by continuous blood gas monitoring. During 63% of all sampling intervals, PaO2 decreased >20% compared with the preceding BGA value, which remained undetected by intermittent analysis. In 10 patients with a continuously measured minimal PaO2 value < or = 60 mm Hg, the preceding BGA overestimated this minimal PaO2 by > 47%. Correspondingly, PaCO2 increases of > 10% were observed in 35% of all sampling intervals, and [H+] increases of > 10% were observed in 24% of all sampling intervals. Because these blood gas changes were not reliably detected by using noninvasive monitoring and their magnitude is not predictable during OLV, intermittent BGA with short sampling intervals is warranted. In critical cases, continuous blood gas monitoring may be helpful. IMPLICATIONS: The magnitude of blood gas changes during thoracoscopic surgery with one-lung ventilation is not predictable and not reliably detected by noninvasive monitoring. Using a continuous intraarterial blood gas monitoring device, we demonstrated that intermittent laboratory blood gas analysis with short sampling intervals is warranted to detect arterial hypoxemia.

Adolescent

Haemodilution tolerance in patients with mitral regurgitation.

Haemodynamic parameters and oxygen consumption were determined in 20 patients with mitral regurgitation before and after a 12 ml.kg-1 isovolaemic exchange of blood for 6% hydroxyethyl starch. During haemodilution, mean (SEM) haemoglobin concentration decreased from 13.0 (0.4) to 10.3 (0.4) g.dl-1 (p = 0.001). With cardiac filling pressures maintained at predilution levels, cardiac index increased from 1.84 (0.08) to 1.94 (0.08) l.min-1.m-2 (p = 0.025) while systemic vascular resistance decreased from 1556 (86) to 1425 (83) dyne.s.cm-5 (p = 0.002) and oxygen extraction increased from 31.7 (1.1) to 37.3 (1.4)% (p = 0.001) resulting in an unchanged oxygen consumption. The haemodynamic response to haemodilution was not affected by the patients' cardiac rhythm, i.e. whether it was sinus rhythm or atrial fibrillation. In conclusion, isovolaemic haemodilution to a haemoglobin of 10.3 g.dl-1 is well tolerated in patients with mitral regurgitation. Compensatory mechanisms include both an increase in cardiac index and an increase in oxygen extraction.

Aged

Effects of intravenous and oral clonidine on hemodynamic and plasma-catecholamine response due to endotracheal intubation.

STUDY OBJECTIVE: To investigate the effects of intravenous (IV) versus oral clonidine on alterations of heart rate (HR), mean arterial pressure (MAP), cardiac output (CO), and plasma-catecholamines due to endotracheal intubation. DESIGN: Randomized, double-blind, placebo-controlled study. SETTING: University hospital surgery operating room. PATIENTS: 33 ASA physical status I patients were randomly assigned to either receive clonidine 3 micrograms/kg IV immediately prior to anesthesia induction, clonidine 4 micrograms/kg orally 90 minutes prior to anesthesia induction, or placebo. INTERVENTIONS: Insertion of a 14 G cannula in a large cubital vein for the determination of plasma-catecholamines using local anesthesia. Insertion of a radial artery catheter for measuring blood pressure (BP) using local anesthesia. Transthoracic echocardiography determined CO. MEASUREMENTS AND MAIN RESULTS: Heart rate, MAP, CO, and plasma-catecholamine concentrations were measured. Measurements were performed prior to induction, during intubation, and 10 minutes after intubation. During endotracheal intubation, MAP was significantly lower in the IV clonidine group compared with the placebo and the oral clonidine groups. Cardiac output was significantly lower in the IV clonidine group only. In contrast to the placebo group, norepinephrine plasma concentrations did not increase in either clonidine group. Significant alterations of epinephrine plasma concentrations due to intubation were not observed in either group. Hemodynamics after intubation were not impaired by clonidine treatment. CONCLUSIONS: In conclusion, IV clonidine reduced stress response to endotracheal intubation compared with placebo. Oral clonidine at the dose used was less effective in blunting hemodynamic stress response than IV clonidine.

Administration, Oral

Hemocue, an accurate bedside method of hemoglobin measurement?

OBJECTIVE: Evaluate the accuracy of this bedside method to determine hemoglobin (Hb) concentration in general surgery over a wide range of Hb values and to determine potential sources of error. METHODS: Accuracy of Hb measurement using HemoCue (AB Leo Diagnostics, Helsinborg, Sweden) was assessed in 140 surgical blood samples using 7 HemoCue devices in comparison with a CO-Oximeter (IL 482, Instrumentation Laboratory, Lexington, MA). To analyze potential sources of error, packed red cells and fresh frozen plasma were reconstituted to randomized Hb levels of 2-18 g/dL. RESULTS: In the surgical blood samples, the Hb concentration determined by the CO-Oximeter (HbCOOX) ranged from 5.1 to 16.7 g/dL and the Hb concentration measured by HemoCue (HbHC) from 4.7 to 16.0 g/dL. Bias (HbCOOX - HbHC) between HbCOOX and HbHC was 0.6+/-0.6 g/dL (mean +/- SD) or 5.4+/-5.0% (p < 0.001). Also in the reconstituted blood, the bias between HbCOOX and HbHC was significant (0.2+/-0.3 g/dL or 2.1+/-3.2%; p < 0.001). The microcuvette explained 68% of the variability between HbCOOX and HbHC. HemoCue thus underestimates the Hb concentration by 2-5% and exhibits a 8-10 times higher variability with only 86.4% of HbHC being within +/- 10% of HbCOOX. CONCLUSION. Although the mean bias between HbCOOX and HbHC was relatively low, Hb measurement by HemoCue exhibited a significant variability. Loading multiple microcuvettes and averaging the results may increase the accuracy of Hb measurement by HemoCue.

Evaluation Studies as Topic

Haemodynamic effects of pneumoperitoneum in elderly patients with an increased cardiac risk.

We studied the haemodynamic changes induced by pneumoperitoneum (PP) in elderly patients with increased cardiac risk (ASA class III; n = 10; age 72.3 +/- 8.8 years, mean +/- SD, P < 0.05; group 2) and compared the results with patients at normal risk (ASA class I, II; n = 12; age 55.6 +/- 11.8 years; group 1). Thermodilution measurements were performed after induction of general anaesthesia (T1), after onset of PP (T2, intraabdominal pressure 14 mmHg) and after additional 15 degrees head-up tilt (T3). In both groups PP, as compared with T1, induced a significant increase in mean arterial pressure (MAP, mmHg, group 1: 77 +/- 14 to 96 +/- 18, P < 0.05/group 2: 75 +/- 10 to 102 +/- 18, P < 0.01), mean pulmonary artery pressure (MPAP, mmHg: 15 +/- 5 to 22 +/- 4, P < 0.01/18 +/- 3 to 25 +/- 5, P < 0.01), central venous pressure (CVP, mmHg: 7 +/- 2 to 15 +/- 3, P < 0.01/7 +/- 2 to 12 +/- 2, P < 0.01), pulmonary capillary wedge pressure (PCWP, mmHg: 9 +/- 4 to 16.3, P < 0.01/8 +/- 2 to 15 +/- 6, P < 0.01) and in systemic vascular resistance (SVR, dynes s cm-5: 1415 +/- 375 to 1873 +/- 412, P < 0.01/ 1502 +/- 360 to 2067 +/- 647, P < 0.01). Cardiac index (CI, L min-1 m-2: 2.3 +/- 0.3 to 1.9 +/- 0.3, P < 0.05/2.2 +/- 0.4 to 2.2 +/- 0.5 P = 0.76) and oxygen delivery index (DO2I, mL min-1 m-2: 388 +/- 54 to 324 +/- 61, P < 0.05/358 +/- 69 to 353 +/- 82, P = 0.77) decreased in group 1 but not in group 2. Heart rate, stroke Index, pulmonary vascular resistance, arteriovenous oxygen content difference and oxygen consumption index were unchanged. After head-up tilt MAP (mmHg, 92 +/- 15, P < 0.05/ 101 +/- 17, P < 0.01), MPAP (mmHg, 20 +/- 3, P < 0.01/22 +/- 4, P < 0.05), CVP (mmHg, 12 +/- 2, P < 0.01/10 +/- 2, P < 0.01) and PCWP (mmHg, 12 +/- 3, P < 0.05/12 +/- 5, P < 0.05) remained elevated compared with T1 in both groups, SVR (dynes s cm-5, 1575 +/- 372, P = 0.13/1793 +/- 528, P < 0.01) in group 2 only. No complications occurred. The results indicate that PP is associated with significant but relatively benign haemodynamic changes. Anaesthesia for laparoscopic cholecystectomy may be performed safely also in elderly ASA class III patients with increased cardiac risk. An adequate haemodynamic monitoring is recommended.

Aged

Effects of chronic beta-blockade on compensatory mechanisms during acute isovolaemic haemodilution in patients with coronary artery disease.

We have compared compensatory mechanisms during acute isovolaemic haemodilution of 12 ml/kg body weight of blood with hydroxyethyl starch (450,000/0.7) exchange, in non-beta-blocked and beta-blocked patients with coronary artery disease. During haemodilution, mean concentrations of haemoglobin decreased from 12.8 (SEM 0.2) to 10.1 (0.1) g dl-1 (P < 0.01). Only beta-blocked patients had an increase in cardiac index (P < 0.01); in non-beta-blocked patients, cardiac index remained constant. In both groups oxygen extraction increased (P < 0.01), but the increase tended to be greater in non-beta-blocked patients (P = 0.06). Oxygen consumption was maintained in both groups. There were no ECG signs of myocardial ischaemia. We conclude that beta-blocked and non-beta-blocked patients with coronary artery disease tolerated well moderate haemodilution to a haemoglobin value of approximately 10 g dl-1, however, compensatory haemodynamic mechanisms differed fundamentally between the two groups.

Adrenergic beta-Antagonists

Effect of progressive haemodilution with hydroxyethyl starch, gelatin and albumin on blood coagulation.

We have compared the effects of progressive (30% and 60%) in vitro haemodilution with hydroxyethyl starch (HES), gelatin (GEL) and albumin (ALB) with haemodilution using 0.9% saline in 96 patients by thrombelastography. Haemodilution with HES, GEL and ALB significantly (P < 0.05) compromised coagulation time (k), angle alpha and maximal amplitude (MA), with HES having the most negative effect at 30% and 60% haemodilution (P < 0.05). Haemodilution with saline significantly affected all variables of blood coagulation and clot lysis measured by thrombelastography, resulting in an increased coagulability at 30% haemodilution. To specifically assess the intrinsic effect of plasma expander molecules on blood coagulation and clot lysis, we analysed the difference between saline diluted blood (same degree of haemodilution) and plasma expander diluted blood. Prolongation of reaction time (r) was found for HES at 30% and 60% haemodilution and for ALB at 60% haemodilution and an increase in clot lysis by HES, GEL and ALB became evident. We conclude that HES, GEL and ALB compromised blood coagulation, while the maximum effect was found with HES.

Adolescent

Accuracy and clinical performance of a continuous intra-arterial blood-gas monitoring system during thoracoscopic surgery.

Accuracy and performance of the only currently available intra-arterial blood-gas monitoring system (Paratrend 7, PT7) were assessed in 23 patients during thoracoscopic surgery using one-lung ventilation. Over a wide range of values for arterial PO2 (6.1-61.1 kPa), PCO2 (4.1-9.5 kPa) and pH (7.19-7.50), 138 arterial blood-gas values obtained by PT7 were compared with corresponding in vitro laboratory blood-gas measurements. We found good clinical performance with the PT7 and good agreement between PT7 values and in vitro measurements for arterial PO2 (bias (1.96 SD) = 0.38 (9.52) kPa), PCO2 (0.31 (0.76) kPa) and pH (-0.017 (0.065)). Also, the bias for sequential changes between two, consecutive times was not significantly different from the ideal value of 0. We conclude that the PT7 is helpful in monitoring patients during thoracoscopy.

Adult

Video-assisted thoracoscopic volume reduction surgery in patients with diffuse pulmonary emphysema: gas exchange and anesthesiological management.

Arterial blood gases were studied prospectively using continuous intraarterial blood gas monitoring during thoracoscopic volume reduction surgery (VRS) in 24 patients with advanced diffuse pulmonary emphysema. Additionally, the early postoperative course (48 h) of arterial blood gases was studied retrospectively. Twenty-six operations were performed using a combination of thoracic epidural and general anesthesia with left-sided double-lumen intubation for one-lung ventilation (OLV). Arterial blood gases were determined awake, during two-lung ventilation prior to surgery, during OLV (extreme values), and after tracheal extubation. Additionally, the extremes during the whole procedure were determined: avoiding excessive peak inspiratory pressures (26.4 +/- 7.0 cm H2O), minimum PaO2 was 77 +/- 39 mm Hg (mean +/- SD), maximum PaCO2 65 +/- 14 mm Hg (P < 0.0001 versus preoperative values), and minimum pHa 7.22 +/- 0.08 (P < 0.0001). One tension pneumothorax occurred during OLV. Immediate postoperative extubation was performed in 25 of 26 cases, reintubation was necessary in two cases. One patient with coronary artery disease died 36 h after surgery. Hypercapnia (maximum PaCO2 49 +/- 8 mm Hg, minimum pHa 7.37 +/- 0.04, P < 0.01) was still observed 48 h after surgery. These results demonstrate that adequate oxygenation can be preserved during OLV for VRS, but CO2 elimination is impaired. However, intraoperative hypercapnia and immediate postoperative tracheal extubation are well tolerated.