Search PubMed⌕ Search

Biomedical subjects

T Parrish

Publications and source records attributed to T Parrish.

13 recordsLinked to original sources

A duplication in chromosome 4q35 is associated with hereditary benign intraepithelial dyskeratosis.

Hereditary benign intraepithelial dyskeratosis (HBID) is an autosomal dominant disorder characterized by elevated epithelial plaques on the ocular and oral mucous membranes. It has been reported primarily, but not exclusively, in individuals of American Indian heritage in North Carolina. We have examined and obtained DNA on two large families affected by HBID. Using genetic linkage analysis we have localized the HBID gene to chromosome 4 (4q35) with a peak LOD score of 8.97. Molecular analysis of these data reveals that all individuals affected with HBID in both families demonstrate the presence of three alleles for two tightly linked markers, D4S1652 and D4S2390, which map to the telomeric region of 4q35. This suggests the presence of a duplication segregating with the disease phenotype that is most likely involved in its causation.

Alleles↗

Context dependency in the globus pallidus internal segment during targeted arm movements.

Extracellular discharges from single neurons in the internal segment of the globus pallidus (GPi) were recorded and analyzed for rate changes associated with visually guided forearm rotations to four different targets. We sought to examine how GPi neurons contribute to movement preparation and execution. Unit discharge from 108 GPi neurons recorded in 35 electrode penetrations was aligned to the time of various behavioral events, including the onset of cued and return movements. In total, 39 of 108 GPi neurons (36%) were task-modulated, demonstrating statistically significant changes in discharge rate at various times between the presentation of visual cues and movement generation. Most often, strong modulation in discharge rate occurred selectively during either the cued (n = 32) or return (n = 2) phases of the task, although a few neurons (n = 5) were well-modulated during both movement phases. Of the 34 neurons that were modulated exclusively during cued or return movements, 50% (n = 17) were modulated similarly in association with movements to any target. The remaining 17 neurons exhibited considerable diversity in their discharge properties associated with movements to each target. Cued phases of behavior were always rewarded if executed correctly, whereas return phases were never rewarded. Overall, these data reveal that many GPi neurons discharged in a context-dependent manner, being modulated during cued, rewarded movements, but not during similar self-paced, unrewarded movements. When considered in the light of other observations, the context-dependence we have observed seems likely to be influenced by the animal's expectation of reward.

Acoustic Stimulation↗

Functional MR imaging.

Functional MR (fMR) imaging offers unprecedented spatial and temporal resolution of brain cognition. The impact of this technology on neuroscience research is just now being explored. This article discusses blood oxygenation level-dependent-based fMR imaging. Topics include the origin of the MR-based signal, data acquisition and sequence dependence, and paradigm design issues--issues that need to be fully understood to properly design and interpret the fMR imaging experiment.

Brain Mapping↗

Functional impact of an increase in ventricular mass after myocardial damage and its attenuation by converting enzyme inhibition.

BACKGROUND: A increase in left ventricular mass after ventricular damage has been identified as an initial response to injury. However, the functional significance of this response has not been clearly established and is the focus of this study. METHODS AND RESULTS: Twelve mongrel dogs underwent transmyocardial direct current shock to produce transmural left ventricular damage. Six were assigned to converting enzyme inhibitor therapy initiated 24 hours after damage and continued for 4 weeks. The remaining six dogs served as a control group. Left ventricular structure (mass and end diastolic volume) and systolic function (regional and global ejection fraction at rest and during afterload stress) were assessed by magnetic resonance imaging before damage and at the end of the 4-week period. After myocardial damage, left ventricular mass increased from 93.6 +/- 4.0 to 107.5 +/- 3.4 gm in the control group (P < .01) with no change in ventricular volume. Ramipril-treated dogs displayed a reduction in mass (83.2 +/- 2.2 to 74.6 +/- 2.9 gm, P < .05). In the control group, there was greater reduction in global ejection fraction in response to afterload stress at 4 weeks compared with baseline (-16 +/- 4 vs -4 +/- 3%, P = .03). Ejection fraction response to afterload stress was maintained at 4 weeks in the converting enzyme inhibitor-treated group (-5 +/- 3 vs - 1 +/- 4%) and was different at 4 weeks from the control group (-1 +/- 4 vs -16 +/- 4%, P = .004). CONCLUSION: The increase in left ventricular mass noted after direct current shock was associated with the impairment of systolic function during afterload stress. Inhibition of this mass increase results in preservation of function, thus further supporting the concept that attenuation of ventricular remodeling should be a therapeutic goal.

Angiotensin-Converting Enzyme Inhibitors↗

Bradykinin antagonism inhibits the antigrowth effect of converting enzyme inhibition in the dog myocardium after discrete transmural myocardial necrosis.

BACKGROUND: Converting enzyme inhibitor (CEI) therapy, but not angiotensin II subtype I receptor blockade, has been shown to attenuate left ventricular remodeling in the dog after transmyocardial direct current (DC) shock. The purpose of this study was to address the importance of preservation of bradykinin to the antiremodeling effect of CEI treatment in this model. METHODS AND RESULTS: Twenty-four hours after DC shock, adult mongrel dogs were assigned to one of three groups: a control group; a group treated with ramipril 10 mg BID; and a group treated with ramipril 10 mg BID along with a continuous subcutaneous infusion of HOE 140, a bradykinin antagonist. To assess change in left and right ventricular structure, a magnetic resonance imaging (MRI) study was performed 4 weeks after DC shock and compared with a baseline MRI study performed before DC shock. The increase in left ventricular mass (mean +/- SEM) in the control group was similar to that observed in the CEI-HOE 140 group (+0.73 +/- 0.19 versus +0.75 +/- 0.18 g/kg, P = NS), but both were greater than the change in mass in the ramipril group (-0.48 +/- 0.13 g/kg, P = .004 and P = .0005, respectively). No significant change occurred in left ventricular volume or right ventricular structure in any group. Mean arterial pressure was reduced by ramipril compared with the control group (-8 +/- 2 versus +7 +/- 2 mm Hg, P = .03), and this effect was not blunted by the addition of HOE 140 (-7 +/- 3 mm Hg). CONCLUSIONS: Prevention by ramipril of the early increase in left ventricular mass in the DC shock model appears to be related to the preservation of bradykinin.

Angiotensin-Converting Enzyme Inhibitors↗

Continuous update with random encoding (CURE): a new strategy for dynamic imaging.

Although dynamic imaging is presently used for various applications, it is still limited by the temporal resolution. In this paper, we present a new technique that uses a random phase-encoding strategy to facilitate faster and smoother update of images and to improve the temporal resolution in dynamic studies. The technique was implemented on a conventional clinical scanner and demonstrated with various in vivo studies. Technical details, simulations, and experimental results are described. Images from experimental studies indicate that the new technique is robust in generating dynamic images and can be potentially utilized for clinical applications.

Abdomen↗

Retrospective estimation and correction of physiological fluctuation in functional MRI.

Image-to-image fluctuation due to physiological motion is a major limitation to the accurate detection of neuronal activity with functional MRI. In this paper, a new and general technique for the estimation and compensation of the physiological effects is presented. By simultaneously monitoring the respiration and heart beat during the acquisition of imaging data, and retrospectively synchronizing the imaging data with physiological activity, physiological effects are estimated and removed. This technique does not rely on the periodicity of the respiration or the heart beat, does not affect the signal changes arising from neuronal activation, and is beneficial to images acquired with any speed. Experimental studies performed with FLASH and EPI sequences have demonstrated that the new technique is effective in reducing physiological fluctuation and improving the sensitivity of functional MRI and is generally applicable.

Algorithms↗

Reduction of field of view for dynamic imaging.

This paper describes a simple technique that improves the temporal resolution for certain dynamic imaging applications. The technique is based on the assumption that the image to image intensity changes sought in dynamic imaging studies are sometimes localized, and a smaller field of view can be used to reduce imaging time. Technical details and experimental results are presented. Experimental results show that this technique works reasonably well for in vivo applications.

Algorithms↗

A new T2 preparation technique for ultrafast gradient-echo sequence.

The T2 contrast in images obtained with driven equilibrium (90degreesx-180degreesx-90degreesx) prepared ultrafast gradient-echo sequence is compromised by the longitudinal magnetization build-up after the second 90degreesx pulse, which does not carry T2 information. This paper describes a new T2 contrast preparation technique for ultrafast gradient-echo sequence that suppresses the signal arising from the build-up. By dephasing in the preparation and rephasing in the acquisition of the gradient echoes, the new technique eliminates signals that are not dictated by the T2 contrast in a driven-equilibrium approach. Consequently, it generates an image that is essentially T2-weighted. Phantom and in vivo experiments were conducted to validate the technique and to demonstrate its clinical utility. These studies indicate that the technique works properly and can be used for in vivo studies.

Animals↗

Concepts of myocardial perfusion imaging in magnetic resonance imaging.

Based on the major innovations in ultrafast magnetic resonance (MR) imaging in recent years, myocardial perfusion imaging with MR has become the focus of many investigators. Two major approaches to myocardial perfusion imaging involve either exogenous or endogenous contrast agents. For the first category of perfusion experiments, we review the characteristics of the common contrast agents and MR techniques for experimental and clinical first-pass studies and in particular address the question of extracting quantitative estimates for myocardial blood flow (milliliters per minute per gram) and volume (milliliters per gram). We demonstrated quantitative perfusion analysis using intravascular relaxation agents and heavily T1-weighted ultrafast gradient echo sequences. Signal time curves need to be transformed to content time curves and the resulting residue functions were analyzed with a multiple-pathway, axially distributed perfusion model. These preliminary results suggest that quantitative assessment of myocardial perfusion is feasible, but additional studies should provide further confidence for this novel MR approach. The exact sensitivity and specificity of MR first-pass imaging in conjunction with extracellular contrast agents in patient studies and its diagnostic accuracy as judged against coronary angiography and scintigraphic perfusion imaging remain yet undefined. The second category of perfusion experiments does not require exogenous contrast agents and has not yet been tested in patient studies. Progress is reported on several MR perfusion-sensitive methods that use the tissue water as an endogenous contrast agent in combination with magnetization transfer techniques as well as paramagnetic deoxyhemoglobin for measuring tissue oxygenation using heavily T2*-weighted sequences for blood oxygen-level-dependent contrast. Possible future directions and developments toward further improvements for MR myocardial perfusion measurements and contraction-perfusion matching are also addressed.

Blood Volume↗

Rapid, accurate and simultaneous noninvasive assessment of right and left ventricular mass with nuclear magnetic resonance imaging using the snapshot gradient method.

Left ventricular, and possibly also right ventricular, mass is an important determinant of prognosis in cardiovascular disease. Consequently, noninvasive estimation of ventricular mass may be an important clinical investigation. The ideal technique for this purpose would be widely available and accurate, employ short study times and avoid exposure to contrast agents and radiation. Conventional nuclear magnetic resonance (NMR) imaging fulfills most of these criteria, but it is time-consuming and expensive. Moreover, its accuracy in estimating right ventricular mass has yet to be assessed. Accordingly, high speed NMR imaging using the snapshot gradient echo technique was used to assess right and left ventricular mass in 10 dogs and the results were compared with values obtained at autopsy, which ranged from 26.1 to 52.9 and 61 to 119.8 g, respectively. The mean absolute difference between the NMR imaging estimates and autopsy findings was 2 +/- 1.2 g (range 0.4 to 4.2) for right ventricular mass and 4.4 +/- 1.7 g (range 1.8 to 6.6) for left ventricular mass. Total NMR imaging time was less than or equal to 5 min. These data demonstrate that high speed NMR imaging can be used to accurately estimate right as well as left ventricular mass.

Animals↗

3-D FLASH imaging using a single surface coil and a new adiabatic pulse, BIR-4.

A new adiabatic pulse, which can induce uniform and arbitrary flip angles despite the presence of transmitter coil magnetic field (B1) inhomogeneities, is employed for 3-D fast imaging using a single surface coil for pulse transmission and signal detection. Computer calculations and phantom, rat, and human surface coil imaging experiments demonstrate the utility of this adiabatic pulse for T1-weighted imaging with a transmitter coil which generates a highly inhomogeneous B1 field profile.

Animals↗