Search PubMed⌕ Search

Biomedical subjects

T Okabe

Publications and source records attributed to T Okabe.

At least 37 records · Page 2Linked to original sources

Study of time-dependent CP violation in B0-->J/psipi0 decays.

We report a measurement of CP asymmetry parameters in the decay B0(B (0))-->J/psipi(0), which is governed by the b-->cc d transition. The analysis is based on a 140 fb(-1) data sample accumulated at the Upsilon(4S) resonance by the Belle detector at the KEKB asymmetric-energy e(+)e(-) collider. One neutral B meson in the J/psipi(0) final state is fully reconstructed for events used in this analysis. The accompanying B meson flavor is identified by its decay products. From the distribution of proper-time intervals between the two B decays, we obtain the following CP-violating parameters: S(J/psipi(0))=-0.72+/-0.42(stat)+/-0.09(syst) and A(J/psipi(0))=-0.01+/-0.29(stat)+/-0.03(syst).

Journal Article↗

Observation of B+-->LambdaLambdaK+.

We report the first observation of the charmless hyperonic B decay, B+-->LambdaLambdaK+, using a 140 fb(-1) data sample recorded at the Upsilon(4S) resonance with the Belle detector at the KEKB (e+)(e-) collider. The measured branching fraction is B(B+-->LambdaLambdaK+) = (2.91(+0.90)(-0.70) +/- 0.38) x 10(-6). We also perform a search for the related decay mode B+-->LambdaLambdapi+, but do not find a significant signal. We set a 90% confidence-level upper limit of B(B+-->LambdaLambdapi+) < 2.8 x 10(-6).

Journal Article↗

Evidence for B+-->omegal+nu.

We have searched for the decay B+-->omegal(+)nu (l=e or mu) in 78 fb(-1) of Upsilon(4S) data (85x10(6)BB events) accumulated with the Belle detector. The final state is fully reconstructed using the omega decay into pi(+)pi(-)pi(0), combined with detector hermeticity to estimate the neutrino momentum. A signal of 414+/-125 events is found in the data, corresponding to a branching fraction of (1.3+/-0.4+/-0.2+/-0.3)x10(-4), where the first two errors are statistical and systematic, respectively. The third error reflects the estimated form-factor uncertainty.

Journal Article↗

Evidence for B0-->rho0pi0.

We present the first evidence of the decay B0-->rho(0)pi(0), using 140 fb(-1) of data collected at the Upsilon(4S) resonance with the Belle detector at the KEKB asymmetric e(+)e(-) collider. We detect 15.1+/-4.8 signal events with a significance of 3.5 standard deviations and measure the branching fraction to be B(B0-->rho(0)pi(0))=(5.1+/-1.6(stat)+/-0.9(syst))x10(-6).

Journal Article↗

SEM/EDS evaluation of porcelain adherence to gold-coated cast titanium.

The adhesion between titanium and dental porcelain is related to the diffusion of oxygen to the reaction layer formed on cast-titanium surfaces during porcelain firing. The diffusion of oxygen could be suppressed by coating the titanium surface with a thin gold layer. This study characterized the effects of gold coating on titanium-ceramic adhesion. ASTM grade II CP titanium was cast into a MgO-based investment (Selevest CB, Selec). The specimen surfaces were air abraded with 110-microm Al(2)O(3) particles. Gold coating was applied on titanium surfaces by three methods: gold-paste (Deck Gold NF, Degussa-Ney) coating and firing at 800 degrees C for three times, single gold-paste coating and firing followed by sputter coating (40 mA, 500 s), and sputter coating (40 mA, 1000 s). Surfaces only air abraded with Al(2)O(3) particles were used as controls. An ultra-low-fusing dental porcelain (Vita Titankeramik, Vident) was fused on titanium surfaces. Specimen surfaces were characterized by SEM/EDS and XRD. The titanium-ceramic adhesion was evaluated by a biaxial flexure test (N = 8), and area fraction of adherent porcelain (AFAP) was determined by EDS. Numerical results were statistically analyzed by one-way ANOVA and the Student-Newman-Keuls test at alpha = 0.05. SEM fractography showed a substantial amount of porcelains remaining on the gold-sputter-coated titanium surfaces. A new Au(2)Ti phase was found on gold-coated titanium surface after the firing. Significantly higher (p <.05) AFAP values were determined for the gold-sputter-coated specimens compared to the others. No significant differences were found among the other groups and the control. Results suggested that gold coatings used in this study are not effective barriers to completely protect titanium from oxidation during the porcelain firing, and porcelain adherence to cast titanium can be improved by gold-sputter coating used in the present study.

Dental Porcelain↗

Initial mercury evaporation from experimental Ag-Sn-Cu amalgams containing Pd.

This study examined the Hg evaporation during setting from experimental Ag-Sn-Cu alloy powders with and without Pd. Four series of alloy powders were fabricated to examine the effect on the Hg evaporation of the alloy compositions (all percentages in this report are weight percents): Pd (0-1.5), Cu (9.0-14.0), Ag (57.0-63.7), and Sn (24.9-29.5). These variations in composition produced alloy powders with gamma-Ag3Sn to beta-AgSn ratios varying from 0.0 to 23.9. The total amounts of Hg released from 10 min after trituration were measured from cylindrical specimens (4 x 8mm; n = 4 ) at 37 degrees C using a Hg vapor analyzer. The results were compared to those from commercial alloys (one high-Cu and one low-Cu alloy). All amalgams made from alloys containing 1.5% Pd exhibited lower Hg vapor release than any other amalgams, with the exception of the low-Cu amalgam. The results clearly showed that the alloy formulation affected the mercury evaporation behavior during setting of the resultant amalgams. A small addition of Pd to the alloy can produce amalgams with 50-60% less Hg vapor release during setting than a leading commercial high-Cu amalgam, Tytin.

Copper↗

Effect of heat treatments on machinability of gold alloy with age-hardenability at intraoral temperature.

OBJECTIVE: This study investigated the effect of heat treatment on the machinability of heat-treated cast gold alloy with age-hardenability at intraoral temperature using a handpiece engine with SiC wheels and an air-turbine handpiece with carbide burs and diamond points. METHODS: Cast gold alloy specimens underwent various heat treatments [As-cast (AC); Solution treatment (ST); High-temperature aging (HA), Intraoral aging (IA)] before machinability testing. The machinability test was conducted at a constant machining force of 0.784N. The three circumferential speeds used for the handpiece engine were 500, 1,000 and 1,500 m/min. The machinability index (M-index) was determined as the amount of metal removed by machining (volume loss, mm(3)). The results were analyzed by ANOVA and Scheffé's test. RESULTS: When an air-turbine handpiece was used, there was no difference in the M-index of the gold alloy among the heat treatments. The air-turbine carbide burs showed significantly (p<0.05) higher M-indexes than the diamond points after any heat treatments. With the SiC wheels, increasing the circumferential speed increased the M-index values for each heat treatment. The specimens heat-treated with AC, HA and IA had similar M-indexes at the lower speeds (500 and 1,000 m/min). The ST specimens exhibited the lowest M-index at the lower speeds. However, at the highest speed (1,500 m/min), there were no significant differences in the M-indexes among the heat treatments except for HA, which showed the highest M-index. CONCLUSION: There was no effect of heat treatment on the machinability of the gold alloy using the air-turbine handpiece. The heat treatments had a small effect on the M-index of the gold alloy machined with a SiC wheel for a handpiece engine.

Body Temperature↗

Cytotoxicity of commercial and novel binary titanium alloys with and without a surface-reaction layer.

Titanium-based alloys form a surface reaction layer when cast. This study investigated the effect of the surface reaction layer on the cytotoxicity of novel Ti-based binary alloys. The cytotoxicities of the novel alloys were compared with commercially pure titanium, Ti-6Al-4V and Ti-6Al-7Nb. Cast discs with or without the reaction layer were first tested for cytotoxicity, then for elemental release into cell-culture medium. The elements released into the extracts were measured by means of an inductively coupled plasma atomic emission spectrometer. The commercial and novel binary Ti-based alloys showed no statistically significant cytotoxicity, although some trends were noted for several alloys. The presence of the reaction layer did not significantly alter the cytotoxicity. These favourable biocompatibility results show that these novel alloys have promise for use in dental restorations.

Alloys↗

Mechanical properties of cast Ti-6Al-4V-XCu alloys.

The mechanical properties of Ti-6Al-4V-XCu (1, 4 and 10 wt% Cu) alloys were examined. The castings for each alloy were made in a centrifugal titanium casting machine. Two shapes of specimens were used: a dumbbell (20 mm gauge length x 2.8 mm diameter) for mechanical property studies, and a flat slab (2 mm x 10 mm x 10 mm) for metallography, microhardness determination and X-ray diffractometry. Tensile strength, yield strength, modulus of elasticity, elongation and microhardness were evaluated. After tensile testing, the fracture surfaces were observed using scanning electron microscopy. The tensile strengths of the quaternary alloys decreased from 1016 MPa for the 1% Cu alloy to 387 MPa for the 10% Cu alloy. Elongation decreased with an increase in the copper content. The 1% Cu alloy exhibited elongation similar to Ti-6Al-4V without copper (3.0%). The results also indicated that the copper additions increased the bulk hardness of the quaternary alloy. In particular, the 10% Cu alloy had the highest hardness and underwent the most brittle fracture. The mechanical properties of cast Ti-6Al-4V alloy with 1 and 4% Cu were well within the values for existing dental casting non-precious alloys.

Alloys↗

Observation of B0-->pLambda(pi)(-).

We report the first observation of the charmless hyperonic B decay, B0-->pLambda(pi)(-), using a 78 fb(-1) data sample recorded on the Upsilon(4S) resonance with the Belle detector at KEKB. The measured branching fraction is B(B0-->pLambda(pi)(-))=(3.97(+1.00)(-0.80)+/-0.56)x10(-6). Searches for B0-->pLambda(K)- and pSigma(0)pi(-) yield no significant signals and we set 90% confidence-level upper limits of B(B0-->pLambda(K)-)<8.2x10(-7) and B(B0-->pSigma(0)pi(-))<3.8x10(-6).

Journal Article↗

Mercury release from dental amalgams into continuously replenished liquids.

OBJECTIVE: Studies have been performed using high- and low-copper amalgams to measure the amounts of mercury dissolution from dental amalgam in liquids such as artificial saliva; however, in most cases, mercury dissolution has been measured under static conditions and as such, may be self-limiting. This study measured the mercury release from low- and high-copper amalgams into flowing aqueous solutions to determine whether the total amounts of dissolution vary under these conditions when tested at neutral and acidic pH. METHODS: High- and low-copper amalgam specimens were prepared and kept for 3 days. They were then longitudinally suspended in dissolution cells with an outlet at the bottom. Deionized water or acidic solution (pH1) was pumped through the cell. Test solutions were collected at several time periods up to 6 days or 1 month and then analyzed with a cold vapor atomic absorption spectrophotometer. After dissolution testing, the specimens were examined using SEM/XEDA for any selective degradation of the phases in the amalgam. RESULTS: Except for the high-copper amalgam in the pH1 solution, the dissolution rates were found to decrease exponentially with time. The rate for the high-copper amalgam in pH1 solution slowly increased for 1 month. The total amounts (microgram/cm(2)) of mercury released over 6 days or 1 month from both types of amalgam in deionized water were not significantly different (p>/=0.05). The high-copper amalgam released significantly more mercury than the low-copper amalgam in the pH1 solution at both time periods. For both amalgams, the dissolution in pH1 was significantly higher than in deionized water. SIGNIFICANCE: Mercury dissolution from amalgam under dynamic conditions is enhanced in an acidic media, and most prominently for a high-copper formulation.

Acids↗

Casting behavior of titanium alloys in a centrifugal casting machine.

Since dental casting requires replication of complex shapes with great accuracy, this study examined how well some commercial titanium alloys and experimental titanium-copper alloys filled a mold cavity. The metals examined were three types of commercial dental titanium [commercially pure titanium (hereinafter noted as CP-Ti), Ti-6Al-4V (T64) and Ti-6Al-7Nb (T67)], and experimental titanium-copper alloys [3%, 5% and 10% Cu (mass %)]. The volume percentage filling the cavity was evaluated in castings prepared in a very thin perforated sheet pattern and cast in a centrifugal casting machine. The flow behavior of the molten metal was also examined using a so-called "tracer element technique." The amounts of CP-Ti and all the Ti-Cu alloys filling the cavity were similar; less T64 and T67 filled the cavity. However, the Ti-Cu alloys failed to reach the end of the cavities due to a lower fluidity compared to the other metals. A mold prepared with specially designed perforated sheets was effective at differentiating the flow behavior of the metals tested. The present technique also revealed that the more viscous Ti-Cu alloys with a wide freezing range failed to sequentially flow to the end of the cavity.

Alloys↗

Corrosion behavior of cast titanium with reduced surface reaction layer made by a face-coating method.

This study characterized the corrosion behavior of cast CP titanium made with a face-coating method. Wax patterns were coated with oxide slurry of Y(2)O(3) or ZrO(2) before investing with a MgO-based investment. Three surface preparations were tested: ground, sandblasted, and as-cast. Uncoated castings served as controls. Sixteen-hour open circuit potential (OCP) measurement, linear polarization and potentiodynamic cathodic polarization were performed in an aerated modified Tani-Zucchi synthetic saliva at 37 degrees C. Anodic polarization was conducted in the same deaerated medium. Polarization resistance (R(p)) and Tafel slopes were determined. Corrosion current density was calculated for each specimen. Results (n=4) were subjected to nonparametric statistical analysis (alpha=0.05). Cross sections of cast specimens were examined by optical microscopy. Energy dispersive spectroscopy (EDS) spot analysis was performed at various depths below the surface. The OCP stabilized within several hours for all the specimens. Apparent differences in anodic polarization behavior were observed among the different surfaces. A distinctive wide passive region followed by breakdown was seen on specimens with ground and sandblasted surfaces. There were no significant differences in the corrosion resistance among the control and the two face-coating groups for each group. The Mann-Whitney test showed significantly lower OCP and higher R(p) values for ground surfaces. The surface condition significantly affected the corrosion behavior more than the face coating methods. In most cases, specimens with as-cast surfaces exhibited the least corrosion resistance during the potentiodynamic anodic polarization.

Coated Materials, Biocompatible↗

Wear resistance of experimental Ti-Cu alloys.

After using cast titanium prostheses in clinical dental practice, severe wear of titanium teeth has been observed. This in vitro study evaluated the wear behavior of teeth made with several cast titanium alloys containing copper (CP Ti+3.0 wt% Cu; CP Ti+5.0 wt% Cu; Ti-6Al-4V +1.0 wt% Cu; Ti-6Al-4V+4.0 wt% Cu) and compared the results with those for commercially pure (CP) titanium, Ti-6Al-4V, and gold alloy. Wear testing was performed by repeatedly grinding upper and lower teeth under flowing water in an experimental testing apparatus. Wear resistance was assessed as volume loss (mm(3)) at 5kgf (grinding force) after 50,000 strokes. Greater wear was found for the six types of titanium than for the gold alloy. The wear resistance of the experimental CP Ti+Cu and Ti-6Al-4V+Cu alloys was better than that of CP titanium and Ti-6Al-4V, respectively. Although the gold alloy had the best wear property, the 4% Cu in Ti-6Al-4V alloy exhibited the best results among the titanium metals. Alloying with copper, which introduced the alpha Ti/Ti(2)Cu eutectoid, seemed to improve the wear resistance.

Alloys↗

Machinability of cast commercial titanium alloys.

This study investigated the machinability of cast orthopedic titanium (metastable beta) alloys for possible application to dentistry and compared the results with those of cast CP Ti, Ti-6Al-4V, and Ti-6Al-7Nb, which are currently used in dentistry. Machinability was determined as the amount of metal removed with the use of an electric handpiece and a SiC abrasive wheel turning at four different rotational wheel speeds. The ratios of the amount of metal removed and the wheel volume loss (machining ratio) were also evaluated. Based on these two criteria, the two alpha + beta alloys tested generally exhibited better results for most of the wheel speeds compared to all the other metals tested. The machinability of the three beta alloys employed was similar or worse, depending on the speed of the wheel, compared to CP Ti.

Alloys↗

Mold filling of titanium alloys in two different wedge-shaped molds.

Pure titanium and titanium alloys are potential materials for the fabrication of cast dental appliances. One important factor in producing sound castings is the capacity of the metal to fill the mold. This study used a wedge-shaped mold to compare the mold filling of titanium with that of conventional dental casting alloys. The metals used were CP Ti, Ti-6Al-7Nb, Ti-6Al-4V, Ti with 1 and 4wt% Cu and ADA Type III gold alloy and an Ni-Cr alloy. The castings were cut into four pieces parallel to the triangular surface. Mold filling was evaluated as the distance between the tip of the cast wedge and theoretical tip of the triangle. The mold filling of the gold alloy was superior compared to all the metals tested, while the mold filling of the Ni-Cr alloy was the worst. There were no statistical differences at the 30 degrees marginal angle for all the cast titanium metals. At the sharper 15 degrees angle, CP Ti and Ti-6Al-7Nb was superior to both the Ti-Cu alloys. Although the mold filling of titanium was inferior compared to the gold alloy, the data justify the use of titanium for the production of dental appliances.

Dental Alloys↗

Tributyltin or triphenyltin inhibits aromatase activity in the human granulosa-like tumor cell line KGN.

The superimposition of male sex organs (penis and vas deferens) in a female gastropod, called imposex, is widely attributed to the exposure to tributyltin (TBT) compounds, used world-wide in antifouling paints for ships. It has been hypothesized that the TBT-induced imposex is mediated by an increasing androgen level relative to the estrogen level, namely a decreased conversion of androgens to estrogens (i.e., aromatization). In the present study, we tested this hypothesis by examining the effects of TBT or triphenyltin (TPT) on the aromatase activity in a cultured human granulosa-like tumor cell line, KGN, which was recently established by our group. Treatment with more than 1000 ng/ml TBT compounds was very toxic to the cells and caused immediate cell death within 24 h, while 200 ng/ml was found to cause apoptosis of the cells. Treatment of the KGN cells for more than 48 h with 20 ng/ml TBT or TPT, which is a concentration level reported to cause imposex in marine species, did not affect cell proliferation but significantly suppressed the aromatase activity determined by a [(3)H]H(2)O release assay. Treatment with 20 ng/ml TBT compounds for 7 days also resulted in a reduction of the E2 production from Delta 4-androstenedione stimulated by db-cAMP. The changes in the aromatase activity by TBT compounds were associated with comparable changes in P450arom mRNA assessed by RT-PCR. The luciferase activity of the P450arom promoter II (1 kb) decreased after the addition of 20 ng/ml TBT compounds in transfected KGN cells either in a basic state or in states stimulated by db-cAMP. The Ad4BP-dependent increase in the luciferase activity of P450arom promoter II was also downregulated by such treatments. These results indicate that TBT compounds inhibited the aromatase activity and also decreased the P450arom mRNA level at the transcriptional level in KGN cells. The direct inhibitory effect of TBT compounds on the aromatase activity may therefore partly explain the induction of imposex by these compounds in female species.

Androstenedione↗

The subnuclear three-dimensional image analysis of androgen receptor fused to green fluorescence protein.

To establish the novel approach in order to distinguish the transcriptionally active androgen receptor (AR) from the transcriptionally inactive AR, we performed the three-dimensional construction of confocal microscopic images of intranuclear AR. This method clearly distinguished the subnuclear localization of transcriptionally active AR tagged with green fluorescent protein (AR-GFP) from the transcriptionally inactive AR-GFP. Transcriptionally active AR-GFP mainly produced 250-400 fluorescence foci in the boundary region between euchromatin and heterochromatin. Although the AR-GFP bound to such antiandrogens as hydroxyflutamide or bicalutamide translocated to the nucleus, they homogeneously spread throughout the nucleus without producing any fluorescence foci. Antiandrogenic environmental disrupting chemicals, such as 1,1-dichloro-2,2-bis(p-chlorophenyl)ethylene, vinclozolin, or nitrofen, also disrupted the intranuclear fluorescence foci. A point mutation (T877A) resulted in the loss of ligand specificity in AR-GFP. Even in this mutant receptor, agonists, such as dihydrotestosterone, hydroxyflutamide, or progesterone, produced the fluorescence foci in the nucleus, whereas the transcriptionally inactive mutant binding bicalutamide was observed to be spread homogeneously in the nucleus. Taken together, our findings suggest that, after nuclear translocation, AR is possibly located in the specific region in the nucleus while demonstrating clustering tightly depending on the agonist-induced transactivation competence.

Active Transport, Cell Nucleus↗